1COMMISSIONINGREFERTOFOLLOWINGTABLEFORIPINFORMATIONNEEDEDTOMAKECONNECTIONBETWEENPCANDRNCPRECONFIGUREDIPSETTINGSIPADDRESSESMASKDEFAULTGATEWAYOMU19216811255255255240NEMUOMS192168151921681625525525524019216811ESA241921681925525525524019216811DHCPSERVERPOOLFORELEMENTMANAGER192168110255255255240DEVICESANDTOOLSFORCOMMISSIONINGWRISTBAND,DIGITALMULTIMETER,M25ALLENKEY內(nèi)六角扳手,RS232CABLERJ45TO9POLFEMALE2PCS,RS232INTERFACE9POLMALECOMPUTERWITHTERMINALAPPLICATIONANDNED2INSPECTINGHARDWARE21INSPECTTHECABLINGTHEREARETHREEFOLLOWINGTYPESOFCABLEINTRASUBRACKCABLESINTRACABINETCABLESINTERCABINETCABLESINTRASUBRACKCABLESANDINTRACABINETCABLESAREINSTALLEDATTHEFACTORYHOWEVER,INTERCABINETCABLESHAVETOBEINSTALLEDATSITEACCORDINGTOTHECABLELISTINSITEDOCUMENTATION22INSPECTTHELOCATIONOFPLUGINUNITSREFERTOEQUIPMENTLISTSINSITEDOCUMENTATIONPOSITIONTHESLOTSAREDENOTEDWITHNUMBERSF01F19INORDERFROMLEFTTORIGHT,PLUSNUMBERF38FORTHEHALFHEIGHTSLOTBELOWSLOTF19,ONTHEFARRIGHTIDCNUMBERNAMEABBREVIATEDNAMEOFTHEPLUGINUNITFUFUNCTIONALUNITNAMEANDINDEXNUMBERFORTHEPLUGINUNIT23INSPECTTHEINTERCHANGEABILITYVERSIONSOFSUBRACKSANDPLUGINUNITSREFERTORNCHWREVISIONLISTINSITEDOCUMENTATIONTHEINTERCHANGEABILITYVERSIONOFAPLUGINUNITSISWRITTENINTHESTICKERRIGHTAFTERTHECNUMBER24INSPECTJUMPERSETTINGSOVERVIEWMOSTOFTHEPLUGINUNITSDONOTREQUIREANYALTERATIONOFTHEIRFACTORYJUMPERSETTINGSTHEPLUGINUNITSINTHEFOLLOWINGTABLEREQUIRESPECIFICJUMPERSETTINGSWHICHMAYHAVETOBEMODIFIEDBYTHECUSTOMERPLUGINUNITJUMPERBLOCKNOTECCPC2AJ16IFUNITISUSEDASOMU,DEFAULTSETTINGSHAVETOBEMODIFIEDHDSCN2FACTORYSETTINGSMAYHAVETOBEMODIFIEDHDS9CN2FACTORYSETTINGSMAYHAVETOBEMODIFIEDHDSACN2FACTORYSETTINGSMAYHAVETOBEMODIFIEDHDSBCN2FACTORYSETTINGSMAYHAVETOBEMODIFIEDMDSA,MDSBJUMPERSANDDIPSWITCHESFACTORYSETTINGSMAYHAVETOBEMODIFIEDTBUFW1FACTORYSETTINGSMAYHAVETOBEMODIFIEDPRESENTATIONOFTHESETTINGSTHESTANDARDANDALTERNATIVEJUMPERSOFTHEPLUGINUNITSAREPRESENTEDINTABLESEXCEPTIFTHEPLUGINUNITHASFACTORYSETTINGSTHESTANDARDSETTINGSAREILLUSTRATEDINTHEJUMPERGROUPLOCATIONMAPSFORTHESTANDARDJUMPERS,THETABLEINDICATESTHEJUMPERGROUPNUMBER,THECONNECTIONREQUIREDANDANOTEABOUTTHECONNECTIONFORTHEALTERNATIVESETTINGS,THEMEANINGOFTHECONNECTIONLIKETHEPLUGINUNITLOCATION,THEREQUIREDCONNECTIONANDANOTEABOUTTHECONNECTIONARELISTEDEACHALTERNATIVEJUMPERGROUPISPRECEDEDBYATITLEDESCRIBINGITINTHECOLUMNJUMPERPOSITION,AHYPHENISUSEDBETWEENTHEPINSOFTHEJUMPERPAIRTHATARETOBECONNECTEDONTHEPLUGINUNITTHEPINSARESYMBOLIZEDBYCONSECUTIVENUMBERSIFTHEREISONLYAHYPHENANDNONUMBERSINTHECOLUMN,NOCONNECTIONISMADETHENUMBERSOFTHEJUMPERGROUP/SAREALSOGIVENFORTHEALTERNATIVESETTINGSTHECOLUMNDESCRIPTIONINDICATESTHEALTERNATIVESELECTEDWITHTHEJUMPERCONCERNEDTHEALTERNATIVESARELISTEDINTHEPLUGINUNITDESCRIPTIONSIFTHEPLUGINUNITHASAJUMPERGROUPFORSETTINGINTERCHANGEABILITY,THESETTINGALTERNATIVESAREPRESENTEDINAFORMTHATDIFFERSFROMTHEPRESENTATIONOFTHEOTHERTABLESINTHEINTERCHANGEABILITYTABLE,XTHECONNECTIONISMADE,BLANKTHECONNECTIONISNOTMADESELECTIONOFSETTINGSSETTINGSAREOFTENREFERREDTOASJUMPERSETTINGS,ORWHENTHEYCANBECLEARLYDEFINEDTHEYAREDIVIDEDINTOTWOGROUPSSTANDARDORDEFAULTSETTINGSALTERNATIVESETTINGSTHEDEFAULTSETTINGSDONOTDEPENDONEXTERNALFACTORSSOTHEYAREALWAYSSETINTHESAMEWAYREGARDLESSOFTHEEQUIPMENTPOSITIONTHEALTERNATIVESETTINGSDEPENDONEXTERNALFACTORS,SUCHASTHETRACKPOSITION,THEPARAMETERTOBESELECTED,ANDTHEOPERATINGENVIRONMENT25INSPECTTHEPOWERSUPPLYMAKESUREYOUHAVEMEASUREDTHEINPUTVOLTAGESTOTHECABINETPOWERDISTRIBUTORSCPDXXANDCHECKEDTHEPOLARITIESOFTHESUPPLYLINESMEASURETHEINPUTVOLTAGESTOTHECABINETPOWERDISTRIBUTIONUNITSTHEVOLTAGESMUSTBEWITHINTHERANGEOF4057VDCCHECKTHATTHEPOLARITIESOFTHESUPPLYLINESARECORRECTTURNONTHEPOWERSWITCHESINTHECABINETPOWERDISTRIBUTIONUNITS3MONITORINGTHEUNITSTARTUP31CONNECTASERVICETERMINALTOOMUANDSWITCHTHEPOWERONENTERCORRECTUSERNAMEANDPASSWORD32ACTIVATETHERCJUUSSERVICETERMINALEXTENSIONZLPJ,RCJ33MONITORTHESTATESOFTHEUNITSZJIALL4LOGGINGINTOTHEMMISYSTEMFORTHEFIRSTTIME41LOGINTOTHEMMISYSTEMFORTHEFIRSTTIME42SETUSERPROFILETHEDEFAULTPROFILEPROFILEDOESNOTHAVERIGHTSFORFTP43CREATENEWADMINISTARATORIDIAHZIAH44LOGOUTZ45ESTABLISHANEWMMLSESSIONWITHTHEADMINISTRATIVEUSERID5CREATINGTELNETORHTTPCONNECTIONTOPRINTALARMSTHELOGICALFILEALARMSISPREDEFINEDTOVPP99WHENOPENINGACONNECTIONWITHAWEBBROWSERTOPORT11111FORTHEFIRSTTIME,THECONNECTIONISOPENEDTOVPP99THESECONDCONNECTIONWILLBETOVPP98THETHIRSISVPP97ACONNECTIONMADETOPORT11111CONNECTSTOTHEFREEVPPDEVICEWITHTHEHIGHESTINDEXWITHINRANGE95TO9951ESTABLSIHATELNETORHTTPCONNECTIONTOOMUIPADDRESS,PORT1111152CHECKTHESTATEOFVPP99ZIHIVPP6INSPECTINGTHEHARDWAREMANAGEMENTSYSTEMTHEPURPOSEOFTHISTESTISTOENSURETHATALLHARDWAREMANAGEMENTSYSTEMHMSNODESRESPONDANDHAVETHESAMELEVELOFFIRMWAREVERSION61HMSOVERVIEWTHEHARDWAREMANAGEMENTSYSTEMHMS/HMSAPROVIDESADUPLICATEDSERIALBUSBETWEENTHEMASTERNODELOCATEDINOMUANDEVERYPLUGINUNITINTHESYSTEMSEEFIGUREPHYSICALCONNECTIONSOFHMS/HMSATHEHMS/HMSAISUSEDINSUPPORTINGAUTOCONFIGURATION,COLLECTINGFAULTDATAFROMPLUGINUNITSANDAUXILIARYEQUIPMENT,CARRYINGMESSAGESINBOOTPHASETOPIUS,ANDSETTINGHARDWARECONTROLSIGNALSLIKERESTARTANDSTATECONTROLINPLUGINUNITSTHEHARDWAREMANAGEMENTSYSTEMISROBUST,FORINSTANCE,ITISINDEPENDENTOFSYSTEMTIMING,ANDITISABLETOREADHARDWAREALARMSEVENFROMAPLUGINUNITWITHOUTPOWERFEEDINORDERTOALLOWPOWERALARMSANDREMOTEPOWERON/OFFSWITCHINGFUNCTIONITFORMSAHIERARCHICALNETWORKANDHASTHREEHIERARCHICALLAYERSFIGURELOGINCALSTRUCTUREOFOFTHEHARDWAREMANAGEMENTSYSTEMHARDWAREMANAGEMENTSYSTEMMASTERNODESHMSMSHARDWAREMANAGEMENTSYSTEMBRIDGENODESHMSBSHARDWAREMANAGEMENTSYSTEMSLAVENODESHMSSSTHEHARDWAREMANAGEMENTSYSTEMMASTERNODESHMSMS,ONEINEACHOMU,CONTROLTHEWHOLESUBSYSTEMTHETSS3SANDTBUFSINTHESUBRACKSHAVESEPARATEHARDWAREMANAGEMENTSYSTEMBRIDGENODESHMSBSTHATSERVEASBRIDGES,WHICHCONNECTHMSMSTOTHELOWESTLEVELBLOCKSINTHEHIERARCHYHARDWAREMANAGEMENTSYSTEMSLAVENODESAREIMPLEMENTEDASDEDICATEDHARDWAREBLOCKSINALLPLUGINUNITS,THESEAREINDEPENDENTFROMTHEOTHERBLOCKSOFTHEPLUGINUNITEGINTERMSOFTHEPOWERSUPPLYTHEHMSNODESCONSISTOF8BITHMSOR16BITHMSAMICROCONTROLLERSANDCOMMUNICATEUSINGTHECANPROTOCOLHMSADDRESSESPLUGINUNITSACCORDINGTOTHEIRLOCATIONINTHESYSTEMTHELOCATIONISDEFINEDINTERMSOFTHREELOCATIONCOMPONENTS1ACCORDINGTORACKLOCATIONINTHESYSTEMEGRACKNUMBER2ACCORDINGTOSUBRACKLOCATIONINAPARTICULARRACKEGSUBRACKNUMBER3ACCORDINGTOPIULOCATIONINTHESUBRACKEGPPASUBRACKNUMBERANDRACKNUMBERAREDEFINEDDURINGEQUIPPINGPHASEOFIPA2800PLATFORMANDTHEYAREPROGRAMMEDTOBACKPLANESERIALEEPROMHMSITSELFWILLSTARTIFFOLLOWINGCONDITIONSAREMETASSUMINGHARDWAREISWORKING1CORRECTSWVERSIONINALLNODESSAMEVERSIONINALLNODES2MASTERNETCONNECTINGHMSMANDHMSBSCORRECTLYCABLEDANDTERMINATED3SUBNETCONNECTIONBETWEENHMSBANDHMSSLAVENODESOKIMPLEMENTEDASBACKPLANETRACESSHOULDALWAYSBEOK4HMSSANDHMSMPIUEEPROMSPROGRAMMED5BACKPLANEEEPROMSPROGRAMMEDWITHCORRECTCONFIGURATIONDATAEEPROMUSEDBYHMSBTOGETRACK2LISTTHESYSTEMCONFIGURATION0000HMEDPTHEOUTCOMEISALISTOFHMSNODESINTHEFOLLOWINGFORMATINTHEEXAMPLEABOVEONLYTHEFIRSTSUBRACKISSHOWNHMSMASTERNODESHAVETHEADDRESSES000000AND000001ADDRESSES3DOR3EAREFORBRIDGENODESTHERESTOFTHEADDRESSESAREFORHMSSLAVENODESNOTETHELISTOFHMSNODESONLYDISPLAYSTHEHMSBRIDGENODESONTHEACTIVEHMSTRANSMISSIONLINETHEPPAOFTHEHMSBRIDGENODESDEPENDSONTHETRANSMISSIONLINETHEPPAOFTHEHMSBRIDGENODESONTHETRANSMISSIONLINE00IS3DTHEPPAOFTHEHMSBRIDGENODESONTHETRANSMISSIONLINE01IS3E3COMPARETHELISTOFHMSNODESTOPLUGINUNITSINTHENETWORKELEMENTEACHPLUGINUNITINCLUDINGOMU,TSS3ANDTBUFHASONESLAVENODEEACHPLUGINUNITINTHERNCMUSTHAVEAHMSSLAVENODELISTEDINTHELISTOFHMSNODESTHEONLYEXCEPTIONISCOMPACTOMS,WHICHDOESNOTHAVEANHMSNODEATALL4ENSURETHECOMPATIBILITYOFHMSNODESABLOCKTHEFOLLOWINGALARMS1183,1186,1291,2689,3287,AND3290ZAFBTOTBENSURETHATALLHMSSLAVENODESHAVETHESAMELEVELOFFIRMWAREVERSIONZ2CO,THEHMNSWVERSIONSHOWSTHEFIRMWAREVERSIONTHEFOLLOWINGEXAMPLESHOWSTHEINFORMATIONOFTHEPLUGINUNITLOCATEDINTHERACK1,SUBRACK1ANDPLUGINUNITADDRESS10ALLHMSSLAVENODESSHOULDHAVETHESAMELEVELOFFIRMWAREVERSIONREPEATTHECOMMANDUNTILYOUHAVETESTEDEVERYHMSNODEOFTHECONFIGURATIONCDISABLEHMSINDEPENDENTSWITCHOVERZ2FBNOTEDISABLINGHMSINDEPENDENTSWITCHOVERTAKESABOUT20SECONDSDCHECKEDTHEACTIVEHMSTRANSMISSIONLINEZ2CMNOTEIFTSS30FPERFORMASWITCHOVEROFTHEHMSTRANSMISSIONLINEINTHISCASE,PERFORMASWITCHOVERTOTHETRANSMISSIONLINE01ACTIVATETHERCBUGGSERVICETERMINALEXTENSIONZLPU,RCBCHANGETHETBU1TOWORKINGSTATEZUCPTBU,1,WOEXGCHECKTHATTHETRANSMISSIONLINESWITCHOVERISSUCCESSFULZ2CMWHENTHEACTIVETRANSMISSIONLINEIS01,THEEXPECTEDOUTCOMEISACTIVEHMSTRANSMISSIONLINE01HINTERROGATETHEFIRMWAREVERSIONNUMBERSOFTHEHMSBRIDGENODESINTHISCASE,THEACTIVETRANSMISSIONLINEIS01THEPPAOFTHEHMSBRIDGENODESIS3EZ2CO,3EIENABLEHMSINDEPENDENTSWITCHOVERZ2FCJCHECKTHATTHESTATUSOFHMSINDEPENDENTSWITCHOVERISENABLEDZ2FFKINTERROGATETHEFIRMWAREVERSIONNUMBERSOFTHEHMSMASTERNODESCO0,0,LUNBLOCKTHEFOLLOWINGALARMS1183,1186,1291,2689,3287,AND3290ZAFU7SETTINGTHECALENDARTIMEANDDATEFORRNC71PURPOSETHEEXTERNALTIMESOURCEWHICHGIVESACONSISTENTTIMEFORALLTHENETWORKELEMENTSINTHENETWORK,CANBEDEFINEDONLYAFTERTHETCP/IPCONNECTIONSARECREATEDWHENYOUHAVEDEFINEDTHEEXTERNALTIMESOURCE,IN15MINUTESALLTHECLOCKSINTHERNCWILLHAVETHESAMETIMEASTHEEXTERNALTIMESOURCEHASTHEEXTERNALTIMESOURCEISLOCATEDINTHENSNNETACTTIMESERVERIPA2800BASEDNETWORKELEMENTSCHECKTHETIMEANDDATEEVERY15MINUTES,PREFERABLYAGAINSTTHEOMSTIMESERVER,USINGNTPMESSAGES72STEPS1DISPLAYDATE,TIMEANDTIMEZONEOFTHENETWORKELEMENTDCDZDCD2SETTHECORRECTDATEANDTIMEFORTHENETWORKELEMENTDCSZDCS,STASARESULT,THEINTERNALCLOCKLOCATEDINTHENETWORKELEMENTGIVESATIMESTAMP,WHICHISINACORRECTTIME,FORALLTHEFUNCTIONSTHATTHECOMPUTERUNITDOES3INTERROGATENTPSERVERIPADDRESSDCIZDCI4SETIPADDRESSFORNTPSERVERIFNEEDEDDCM8INTERROGATINGEQUIPMENTDATABASE81PURPOSEITISRECOMMENDEDTOINTERROGATEINFORMATIONONCABINETS,SUBRACKS,FUNCTIONALUNITS,PLUGINUNITS,ANDCONNECTIONSBETWEENPLUGINUNITSPORTSTHECORRECTHARDWARECONFIGURATIONDESCRIPTIONDATAISDISPLAYEDINTHESITESPECIFICDOCUMENTS82STEPS1CHECKTHESTATEANDINTEGRITYOFTHEEQUIPMENTDATABASEANDCOPYDATABASEFILESTODISKTHEEQUIPMENTDATABASEMUSTBEINTHENORMALSTATETOENSURETHEINQUIREDINFORMATIONISCORRECTACHECKEQDATASTATEDBSZDBSEQDATA,0BSAVEEQDATADATABASELOGTODISKDBOZDBOEQDATA,0CEMPTYEQDATADATABASEDISKUPDATINGLOGDBXZDBXEQDATA,0DPREVENTEQDATAUPDATESTODISKDBPZDBPEQDATA,0DISKEPREVENTEQDATAUPDATESTOMEMORYDBPZDBPEQDATA,0MEMFCHECKTHEINTEGRITYOFEQDATAONDISKDBVZDBVEQDATA,0DISKGRESUMEEQDATAUPDATESTODISKDBRZDBREQDATA,0DISKHRESUMEEQDATAUPDATESTOMEMORYDBRZDBREQDATA,0MEMIDUMPEQDATADATABASEFILESTODISKDBCZDBCEQDATA,0JCHECKEQDATASTATEZDBSEQDATA,02INTERROGATECABINETINFORMATIONWFIZWFIJ,3INTERROGATESUBRACKINFORMATIONWFIZWFIC,4INTERROGATEPLUGINUNITINFORMATIONWFIZWFIP,5INTERROGATECONNECTIONINFORMATIONONPLUGINUNITPORTSWFIZWFIS,6INTERROGATEFUNCTIONALUNITINFORMATIONWFIAINTERROGATEFUNCTIONALUNITSDESCRIPTIONDATAZWFIU,BINTERROGATEWHICHPLUGINUNITSTHEFUNCTIONALUNITISATTACHEDTOZWFIP,83EXAMPLES9INTERROGATINGHARDWAREDATA91PURPOSEINTERROGATETHEHWDATATHATISSTOREDINTHEEEPROMSOFHARDWARECOMPONENTS92STEPS1SELECTONEOFTHEFOLLOWINGTHREEALTERNATIVESINTERROGATEALLHARDWAREDATAWFLZWFLPNOTETHISALTERNATIVEISNOTRECOMMENDED,ASITTAKESVERYLONGTIMEINTERROGATEDATAFROMALLPLUGINUNITSINACABINETWFLZWFLPINTERROGATEDATAFROMONESUBRACKINADEFINEDLOCATIONWFLZWFLS,93EXAMPLES10INTERROGATINGSOFTWAREBUILDINFORMATION101STEPS1VERIFYTHATTHECORRECTSOFTWAREBUILDISONTHEHARDDISKANDALSOLOADEDFOREVERYUNITNEEDEDWQOZWQOCRZWQORUNZWQO2CHECKTHEVERSIONSOFTHESOFTWAREBUILDWQBZWQBNAMEFORMFAILEDTHECOMMANDCOMPARESTHEVERSIONSOFTHESOFTWAREBUILDAGAINSTTHEVERSIONSINTHEMASTERFILETHESYSTEMOUTPUTSTHEERRONEOUSVERSIONSTHECOMMANDALSOCALCULATESACHECKSUMFOREACHSOFTWAREMODULEANDCOMPARESITTOTHECHECKSUMINTHEMODULEHEADERERRONEOUSMODULESAREOUTPUTTHECOMMANDDOESNOTCALCULATETHECHECKSUMFORXMLEXTENSIBLEMARKUPLANGUAGE,TXTTEXTANDDTDDOCUMENTTYPEDEFINITIONFILESTHEREISNOTOTALVERSIONCONTROL,FOREXAMPLE,FORGIFGRAPHICSINTERCHANGEFORMATFILESTHECOMMANDDOESNOTCHECKTHEVERSIONSOFFILESNORCALCULATETHECHECKSUMSITONLYCHECKSTHATTHEFILESEXIST3CHECKTHEVERSIONOFTHEFLASHMEMORYBOOTPACKAGEOFTHEUNITAGAINSTTHESWPACKAGEWDIZWDIUTIFTHEFLASHMEMORYBOOTPACKAGESARENOTCOMPATIBLE,YOUMUSTUPDATETHEBOOTPACKAGEZWDRUT,UITAKENEWBOOTPACKAGEINTOUSEZUSU,11INSPECTINGI/OSYSTEM111STEPS1DISPLAYTHEPHYSICALI/ODEVICESANDCHECKTHEIROPERATINGSTATESIHIZIHI|DEF,|DEF,|DEFINNORMALCONDITION,THEDISKDRIVESAREINTHEWOEXWORKINGSTATEDISPLAYUNITSCHANGETHEIRSTATETOWOEXAFTERACONNECTIONHASBEENESTABLISHEDTOTHEMFORVPPDEVICESCONNECTEDTOLPDLINEPRINTERDAEMONSERVICEPROVIDEDBYTHEUNIXOPERATINGSYSTEM,EMPLOYEDINTCP/IPNETWORKSASAMECHANISMFORUSINGREMOTEPRINTERSDEVICESVPPDEVICESWITHINDEXUNDER50,THESTATECHANGESACCORDINGTOTHESTATEOFTHELPDDEVICETHELPDDEVICEISINTHEWOEXSTATEAFTERTHEUNITSTARTUPLPDDEVICESCHANGETHEIRSTATETOWOEXWHENFUNCTIONALSTATEOFTHEDEVICECHANGESTONORMALORFLUSHTHEOPERATINGSTATEMAYCHANGEONLYWHENYOUEXECUTETHEINSCOMMANDTOCHANGETHEFUNCTIONALSTATEVPPDEVICESWITHINDEXBETWEEN95AND99CHANGETHEIRSTATETOWOEXAFTERACONNECTIONHASBEENESTABLISHEDTOTHEM2CHANGETHEOPERATINGSTATEOFAHARDDISKTOTEEXIHEZIHEWDU,TEONLYONEHARDDISKCANBEINTHETEEXSTATEATATIME3DIAGNOSETHEHARDDISKUDDZUDD,4WHENDIAGNOSISISFINISHED,CHANGETHEHARDDISKOPERATINGSTATETOWOEXZIHEWDU,WO5REPEATSTEPS2,3,AND4ONTHEOTHERHARDDISK6CHANGETHEOPERATINGSTATEOFANOPTICALDISKORAUSBMEMORYSTICKTOTEEXIHEANDDIAGNOSETHEOPTICALDISKORUSBMEMORYSTICKUDDOPTIONALZUDD,I/ODEVICETYPEISFDU00FORUSBOROPTICALDISK7DISPLAYALISTOFRUNNINGANDQUEUEINGTESTS,IFNEEDEDUDQZUDQ8DISPLAYTHEHISTORYOFTHEDIAGNOSTICREPORTS,IFNEEDEDUDHZUDH12INSPECTINGMESSAGINGSYSTEM121PURPOSETHISTESTISCARRIEDOUTTOENSURETHATTHECOMPUTERUNITSCANRECEIVEANDSENDMESSAGESANDAREINWORKINGORDER,ANDTHATTHECABLINGISCORRECTTHETESTALSOCHECKSTHATTHEREARENOFAILURESINSWITCHOVER122STEPS1PRINTTHEWORKINGSTATESOFUNITSUSIZUSIFULLCHECKTHATALLTHEUNITSOFTHEEXCHANGEAREONTHEPRINTLIST2OPENASERVICETERMINALCONNECTIONRS232ORREMOTEDEBUGGERSESSIONZDDSTOTHEACTIVEOMUZDDSOMU,TOOPENAREMOTEDEBUGGERSESSION3LOADAPOSTOFFICESERVICETERMINALEXTENSIONINTHEACTIVEOMUZLP1,POH4LISTALLCOMPUTINGUNITSINTHEMESSAGINGSYSTEMINTHESERVICETERMINALSESSION,LISTALLCOMPUTINGUNITSINTHEMESSAGINGSYSTEMCHECKTHATALLCOMPUTERUNITSWHICHHADPHYSICALANDLOGICALADDRESSESINSTEP1AREALSOLISTEDHEREZ1F15STARTTHEMESSAGINGSYSTEMTEST1YYZ1YY6MONITORTHETESTPROGRESSFORAMINIMUMOF5MINUTES7PRINTTHEWORKINGSTATESFUUNITANDALLMXUUNITSUSIZUSISFUWOEXZUSIMXUWOALL8CHANGETHESTATEOFWORKINGSTATESFUUNITWOEXTOSPEXUSCZUSCSFU,SP9MONITORTHETESTPROGRESSFORAMINIMUMOF5MINUTES10CHANGETHESTATESOFALLWORKINGSTATEMXUUNITSWOEXTOSPEXUSCZUSCMXU,SP11PRINTTHEWORKINGSTATESOFALLMXUUNITSUSITOMAKESURETHATSTATESOFALLMXUUNITSHAVEBEENCHANGED12MONITORTHETESTPROGRESSFORAMINIMUMOF5MINUTES13CHANGETHESTATEOFWORKINGSTATESFUUNITWOEXTOSPEXUSC14MONITORTHETESTFORAMINIMUMOF5MINUTES15STOPTHETESTSTOPTHETESTINTHESERVICETERMINALSESSIONWITHCTRLC13INSPECTINGUNITDIAGNOSTICSANDWORKINGSTATES131PURPOSETHESETESTSARECARRIEDOUTTOENSURETHATTHEHARDWAREISINWORKINGORDERANDTHECABLINGCORRECTUNITSWHICHARECONNECTEDTOSFUANDMXUUNITSMUSTBETESTEDTWICE,FIRSTWHENTHESTATEOFSFUX/MXUXISWOEX,THENWHENTHESTATEOFSFUX1/MXUX1ISWOEXSFUX/MXUXISTHESFU/MXUCONNECTEDTOTHEUNITTOBETESTED132STEPS1PRINTTHEWORKINGSTATESOFUNITSUSI2CHANGETHEUNITSTOTESTSTATETEEX,USC3STARTDIAGNOSISUDUZUDUUSESZUDQTOCHECKONGOINGTEST4INTERROGATERESULTSOFTHEDIAGNOSISUDHZUDH5FORUNITSWITH2NORN1REDUNDANCY,PERFORMSWITCHOVERANDTESTTHEREMAININGUNITSAFORUNITSWITH2NREDUNDANCY,CHANGETHESTATESOFTHEUNITSTHATWERETESTEDFIRSTTOSPEXANDTHENTOWOEXBCHANGETHESTATESOFUNITSNOWINSPEXSTATETOTESTSTATECREPEATSTEPS3AND4ORAFORUNITSWITHN1REDUNDANCY,CHANGETHESTATESOFTHEUNITSTHATWERETESTEDFIRSTTOWOEXBCHANGETHESTATESOFTHEUNITSTHATWERENOTTESTEDYETTOTESTSTATECREPEATSTEPS3AND4IFTHEUNITFAILSTHEDIAGNOSTICTEST,CHECKTHESTRAPPINGSOFTHEUNITORTHECORRESPONDEINGCABLESORREPLACETHEUNITIFITISSUSPECTEDTOBEBROKENREMEMBERTORUNTESTAGAINSTANYNEWUNITWHICHISUSEDTOREPLACETHEOLDONE14VERIFYINGSYSTEMSTARTUP141STEPS1CHECKINGTHATUNITSAREINTHEWOEXANDSPEXUSISTATES2DISCONNECTPOWERFROMTHESYSTEMBECAUTIOUSNOTTOTAKEANYACTIONTHATWILLRESULTINANYPROBLEMS,SUCHASHARDWAREDAMAGEORDATALOSS3CONNECTPOWERTOTHESYSTEMDURINGTHESTARTUPOFTHEOMU,THERECOVERYSYSTEMANALYSESTHECONDITIONOFTHENETWORKELEMENTANDSTARTSTHECONTROLOFTHESYSTEMSTARTUP,ATTHISMOMENT,“0689SYSTEMRESTARTED”WILLBEPRINTEDTOTHEALARMPRINTER4WAITUNTILACTIVEOMUSTARTSINSTATEWOEXTHENAPPEARS“0691WORKINGSTATEACTIVATEDBYSYSTEM”FOLLOWEDBYNOTICE“MMISYSTEMREADY”5OUTPUTWORKINGSTATESOFUNITSFROMTHEMMLTERMINALANDMONITORTHATEVERYUNITSTARTSINTHESTATEITHADBEFORETHEPOWERCUTUSITHEOMUORTBUISNOTNECESSARILYINTHESTATEITHADBEFORETHEPOWERCUT,BECAUSETHEHARDWAREDEFINESTHEACTIVITYOFOMUANDTBU6MONITORTHEALARMPRINTOUTALLTHESTARTINGUNITSSHOULDCREATEANOTICE0691WORKINGSTATEACTIVATEDBYSYSTEM7CHECKTHATNOUNNECESSARYALARMSAREONAAP15INSPECTINGSYNCHRONIZATIONSYSTEM151SYNCHRONIZATIONSYSTEMOVERVIEWNETWORKELEMENTTIMINGANDSYNCHRONIZATIONINTHEIPA2800ISDESIGNEDTOWORKINMASTER/SLAVETYPEHIERARCHICALSYNCHRONIZATIONNETWORKTOPOLOGYNETWORKELEMENTHASDUPLICATEDSYNCHRONIZATIONUNITINTSS3PLUGINUNITTHISUNITRECEIVESREFERENCETIMINGSIGNALFROMUPPERNETWORKLEVEL,ADJUSTSITSLOCALOSCILLATORTOMEANVALUEOFTHEREFERENCESIGNALFILTERSJITTERANDWANDERFROMTHETIMINGSIGNALUSINGDIGITALPHASELOCKEDLOOPANDDELIVERSTHISSYNCHRONIZEDTIMINGSIGNALASSYSTEMTIMINGTOALLPLUGINUNITSINEVERYNETWORKINTERFACEPORT,THETIMINGFREQUENCYISDERIVEDFROMINCOMINGSIGNALINNETWORKINTERFACEPLUGINUNITONEPORTISSELECTEDTOGIVETIMINGTHETSS3HASTHREETIMINGINPUTSFIGURE5THATARECONNECTEDBYCABLINGTOSELECTEDNETWORKINTERFACEPLUGINUNITSPDHINPUTSYNCHRONIZATIONISEXTRACTEDFROMAPDHTIMESLOTSDHINPUTASYNCHRONIZATIONINPUTCANBEEXTRACTEDFROMTHESDHTIMINGSIGNALINADDITIONTOTHEINPUTSFROMTHELINEINTERFACEUNITS,THETSS3HASTWOEXTERNALSYNCHRONIZATIONINPUTSBOTHTSS3SGETTHESAMETHREESIGNALSFROMTHELINEINTERFACEUNITSANDTHESAMETWOEXTERNALSYNCHRONIZATIONSIGNALSFROMTHECPSALCABLINGPANELNETWORKTIMINGREFERENCESCANBEFROMSTM1,E1,T1,ANDJT1TRANSMISSIONLINESEACHTRANSMISSIONINPUTHASADIFFERENTFREQUENCY,ASSHOWNBOTHTHEQUALITYCONTROLOFTHERECEIVEDTIMINGFROMSDHTRANSMISSIONSYSTEMANDTHEFUNCTIONALMODE/STATECONTROLOFTHESYNCHRONIZATIONANDTIMINGFUNCTIONARESETBYTHETIMINGANDSYNCHRONIZATIONFUNCTIONMANAGEMENTINNETWORKELEMENTMANAGEMENTTWOSEPARATETIMINGANDSYNCHRONIZATIONDISTRIBUTIONBUSESINSURE2NREDUNDANCYFORTHEINTERNALTIMINGSIGNALDISTRIBUTIONEACHBUSHASITSOWNSYSTEMCLOCKATSS3PLUGINUNIT,DISTRIBUTIONCABLINGANDTIMINGBUFFERSTBUFPLUGINUNITSTHETWOTSS3UNITSBACKINGEACHOTHERUPAREPLACEDINDIFFERENTSUBRACKSSUBRACKS1AND2,EACHOFWHICHISPOWEREDBYAPOWERSUPPLYPLUGINUNITO
溫馨提示
- 1. 本站所有資源如無特殊說明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請下載最新的WinRAR軟件解壓。
- 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請聯(lián)系上傳者。文件的所有權(quán)益歸上傳用戶所有。
- 3. 本站RAR壓縮包中若帶圖紙,網(wǎng)頁內(nèi)容里面會有圖紙預(yù)覽,若沒有圖紙預(yù)覽就沒有圖紙。
- 4. 未經(jīng)權(quán)益所有人同意不得將文件中的內(nèi)容挪作商業(yè)或盈利用途。
- 5. 人人文庫網(wǎng)僅提供信息存儲空間,僅對用戶上傳內(nèi)容的表現(xiàn)方式做保護(hù)處理,對用戶上傳分享的文檔內(nèi)容本身不做任何修改或編輯,并不能對任何下載內(nèi)容負(fù)責(zé)。
- 6. 下載文件中如有侵權(quán)或不適當(dāng)內(nèi)容,請與我們聯(lián)系,我們立即糾正。
- 7. 本站不保證下載資源的準(zhǔn)確性、安全性和完整性, 同時也不承擔(dān)用戶因使用這些下載資源對自己和他人造成任何形式的傷害或損失。
最新文檔
- 2026春招:伊利集團(tuán)題庫及答案
- 2026年橋梁質(zhì)量監(jiān)督與管理體系
- 2026春招:信息安全顧問題庫及答案
- 2026春招:消防員面試題及答案
- 2026春招:無人機(jī)組裝測試題庫及答案
- 貨運安全生產(chǎn)標(biāo)準(zhǔn)化
- 護(hù)理信息化在護(hù)理質(zhì)量管理與持續(xù)改進(jìn)中的應(yīng)用
- 醫(yī)療行業(yè)信息化與大數(shù)據(jù)
- 醫(yī)學(xué)影像科技術(shù)創(chuàng)新與應(yīng)用總結(jié)
- 2026年德陽科貿(mào)職業(yè)學(xué)院單招職業(yè)技能考試備考題庫帶答案解析
- 有本領(lǐng)的勞動者課件
- 2026年歷史學(xué)業(yè)水平合格考考前模擬卷(江蘇專用)(考試版及全解全析)
- 資產(chǎn)管理全周期標(biāo)準(zhǔn)化操作流程
- 招投標(biāo)業(yè)務(wù)流程及合同管理指南
- 校園小導(dǎo)游測試卷(單元測試)2025-2026學(xué)年二年級數(shù)學(xué)上冊(人教版)
- 2025年西藏公開遴選公務(wù)員筆試試題及答案解析(綜合類)
- 揚州市梅嶺中學(xué)2026屆八年級數(shù)學(xué)第一學(xué)期期末綜合測試試題含解析
- 末梢血標(biāo)本采集指南
- GB/T 46156-2025連續(xù)搬運設(shè)備安全規(guī)范通用規(guī)則
- AI賦能的虛擬仿真教學(xué)人才培養(yǎng)模式創(chuàng)新報告
- 數(shù)據(jù)管理能力成熟度評估模型(DCMM)評估師資格培訓(xùn)試題及答案
評論
0/150
提交評論