數(shù)據(jù)中心基礎(chǔ)設(shè)施運行維護標準_第1頁
數(shù)據(jù)中心基礎(chǔ)設(shè)施運行維護標準_第2頁
數(shù)據(jù)中心基礎(chǔ)設(shè)施運行維護標準_第3頁
數(shù)據(jù)中心基礎(chǔ)設(shè)施運行維護標準_第4頁
數(shù)據(jù)中心基礎(chǔ)設(shè)施運行維護標準_第5頁
已閱讀5頁,還剩42頁未讀, 繼續(xù)免費閱讀

下載本文檔

版權(quán)說明:本文檔由用戶提供并上傳,收益歸屬內(nèi)容提供方,若內(nèi)容存在侵權(quán),請進行舉報或認領(lǐng)

文檔簡介

數(shù)據(jù)中心基礎(chǔ)設(shè)施運行維護標準目次1總則...........................................................................................................................22術(shù)語...........................................................................................................................33基本規(guī)定...................................................................................................................43.1運行維護范圍.....................................................................................................43.2運行維護基本要求.............................................................................................44運行...........................................................................................................................54.1一般規(guī)定.............................................................................................................54.2電氣系統(tǒng).............................................................................................................54.3通風空調(diào)系統(tǒng)...................................................................................................104.4消防系統(tǒng)...........................................................................................................114.5智能化系統(tǒng).......................................................................................................124.6環(huán)境參數(shù)...........................................................................................................135維護.........................................................................................................................145.1一般規(guī)定...........................................................................................................145.2電氣系統(tǒng)...........................................................................................................145.3通風空調(diào)系統(tǒng)...................................................................................................175.4消防系統(tǒng)...........................................................................................................205.5智能化系統(tǒng).......................................................................................................216制度.........................................................................................................................236.1一般規(guī)定...........................................................................................................236.2制度體系...........................................................................................................23本標準用詞說明.........................................................................................................24引用標準名錄.............................................................................................................2511總則1.0.1為實現(xiàn)數(shù)據(jù)中心基礎(chǔ)設(shè)施系統(tǒng)與設(shè)備運行維護的規(guī)范性、安全性和及時性,確保電子信息設(shè)備運行環(huán)境的穩(wěn)定可靠,制訂本標準。1.0.2本標準適用于已投入運行的數(shù)據(jù)中心。1.0.3數(shù)據(jù)中心基礎(chǔ)設(shè)施的運行維護除應(yīng)符合本標準外,尚應(yīng)符合國家現(xiàn)行有關(guān)標準的規(guī)定。22術(shù)語2.0.1數(shù)據(jù)中心datacenter為集中放置的電子信息設(shè)備提供運行環(huán)境的建筑場所,可以是一棟或幾棟建筑物,也可以是一棟建筑物的一部分,包括主機房、輔助區(qū)、支持區(qū)和行政管理區(qū)等。2.0.2基礎(chǔ)設(shè)施infrastructure數(shù)據(jù)中心內(nèi),為電子信息設(shè)備提供運行保障的設(shè)施。2.0.3運行operation對數(shù)據(jù)中心基礎(chǔ)設(shè)施系統(tǒng)和設(shè)備進行日常巡檢、啟停控制、參數(shù)設(shè)置、狀態(tài)監(jiān)控和優(yōu)化調(diào)節(jié)。2.0.4維護maintenance為保證數(shù)據(jù)中心基礎(chǔ)設(shè)施系統(tǒng)和設(shè)備具備良好的運行工況,達到提高可靠性、排除隱患、延長壽命期目的所進行的工作,主要包括預(yù)防性維護、預(yù)測性維護和維修等。2.0.5預(yù)防性維護preventivemaintenance為降低數(shù)據(jù)中心基礎(chǔ)設(shè)施系統(tǒng)和設(shè)備發(fā)生失效或功能退化的概率,按預(yù)定的時間間隔或按既定的準則實施的維護。2.0.6預(yù)測性維護predictivemaintenance通過各種技術(shù)手段進行數(shù)據(jù)和信號的采集、分析,同時結(jié)合設(shè)備運行的壽命期統(tǒng)計規(guī)律或歷史數(shù)據(jù),預(yù)測可能后果,提前采取的有針對性的維護活動。2.0.7事件incident是指意外發(fā)生的導致或可能導致服務(wù)中斷或服務(wù)質(zhì)量下降的事態(tài)。2.0.8變更change是指在運行和維護過程中對數(shù)據(jù)中心基礎(chǔ)設(shè)施系統(tǒng)和設(shè)備所做的各種改變,包括狀態(tài)改變、增補、移除和其他變動。33基本規(guī)定3.1運行維護范圍數(shù)據(jù)中心基礎(chǔ)設(shè)施運行維護范圍應(yīng)包括下列系統(tǒng):電氣系統(tǒng)、通風空調(diào)系統(tǒng)、消防系統(tǒng)、智能化系統(tǒng)。電氣系統(tǒng)的運行維護范圍應(yīng)包括:供配電系統(tǒng)、不間斷電源和后備電源系統(tǒng)、照明系統(tǒng)、配電線路布線系統(tǒng)、防雷與接地系統(tǒng)。通風空調(diào)系統(tǒng)的運行維護范圍應(yīng)包括:冷源和水系統(tǒng)、機房空調(diào)和風系統(tǒng)。消防系統(tǒng)的運行維護范圍應(yīng)包括:火災(zāi)自動報警系統(tǒng)、消防聯(lián)動系統(tǒng)、自動滅火系統(tǒng)。智能化系統(tǒng)的運行維護范圍應(yīng)包括:環(huán)境和設(shè)備監(jiān)控系統(tǒng)、安全防范系統(tǒng)。3.2運行維護基本要求運行維護團隊宜參與基礎(chǔ)設(shè)施系統(tǒng)和設(shè)備安裝、調(diào)試和驗證的過程。數(shù)據(jù)中心正式投入使用前應(yīng)進行綜合系統(tǒng)測試。數(shù)據(jù)中心基礎(chǔ)設(shè)施系統(tǒng)與設(shè)備的運行維護管理應(yīng)實現(xiàn)如下基本目標:1通過有效地計劃、組織、協(xié)調(diào)與控制,確保電子信息設(shè)備運行環(huán)境穩(wěn)定可靠。2通過科學管理,實現(xiàn)數(shù)據(jù)中心基礎(chǔ)設(shè)施運行維護服務(wù)與經(jīng)濟性的最優(yōu)化。數(shù)據(jù)中心基礎(chǔ)設(shè)施的運行維護宜按不同設(shè)計或建設(shè)等級進行。數(shù)據(jù)中心場地周邊的地質(zhì)災(zāi)害、水災(zāi)、火災(zāi)等隱患應(yīng)定期進行檢查。電力、制冷和消防等各系統(tǒng)應(yīng)定期進行聯(lián)動測試。運行維護人員發(fā)現(xiàn)基礎(chǔ)設(shè)施系統(tǒng)和設(shè)備隱患、異常、故障、報警等問題,應(yīng)按照事件管理程序或既定處理措施處理?;A(chǔ)設(shè)施系統(tǒng)與設(shè)備故障和維護期間,應(yīng)有相應(yīng)的保障措施和應(yīng)急預(yù)案。數(shù)據(jù)中心運行維護操作人員應(yīng)具備行業(yè)規(guī)定的職業(yè)資格。44運行4.1一般規(guī)定基礎(chǔ)設(shè)施系統(tǒng)與設(shè)備運行應(yīng)包括值班、監(jiān)控、日常巡檢、運行操作、報警和事件處理等內(nèi)容。A級數(shù)據(jù)中心應(yīng)24小時值班,B級和C級數(shù)據(jù)中心宜按照電子信息設(shè)備負載的重要性確定值班時間。消防系統(tǒng)和安全防范系統(tǒng)應(yīng)24小時保持正常工作狀態(tài),不得隨意中斷。運行人員應(yīng)按照巡檢計劃、周期、規(guī)定路線對基礎(chǔ)設(shè)施系統(tǒng)和設(shè)備及運行環(huán)境進行巡檢,巡檢記錄應(yīng)及時、完整、真實、清晰。A級數(shù)據(jù)中心每日現(xiàn)場巡檢次數(shù)不應(yīng)少于2次,B級和C級數(shù)據(jù)中心每日現(xiàn)場巡檢次數(shù)不應(yīng)少于1次。有能耗計量系統(tǒng)的數(shù)據(jù)中心,應(yīng)保證能耗計量裝置正常工作,數(shù)據(jù)完整有效。數(shù)據(jù)中心能耗數(shù)據(jù)應(yīng)定期進行綜合分析,合理優(yōu)化電氣與通風空調(diào)系統(tǒng)的運行控制策略,提高整體電能使用效率。設(shè)備有備用或冗余的,應(yīng)輪換使用。4.2電氣系統(tǒng)I供配電系統(tǒng)高壓供配電設(shè)備應(yīng)設(shè)置運行參數(shù)監(jiān)控和報警系統(tǒng),監(jiān)控不應(yīng)少于表4.2.1-1所列內(nèi)容,報警不應(yīng)少于表4.2.12所列內(nèi)容。表11234表212534高壓配電室或值班室內(nèi)應(yīng)設(shè)置數(shù)據(jù)中心供配電系統(tǒng)圖。主機房和非主機房使用的供配電設(shè)備應(yīng)有明確的標識并宜進行顏色區(qū)分。高壓供配電設(shè)備日常巡檢不應(yīng)少于表4.2.4所列內(nèi)容。表1性23456變壓器應(yīng)設(shè)置運行參數(shù)監(jiān)控和報警系統(tǒng),監(jiān)控不應(yīng)少于表4.2.51所列內(nèi)容,報警不應(yīng)少于表4.2.52所列內(nèi)容。表1123表212變壓器日常巡檢不應(yīng)少于表4.2.6所列內(nèi)容。表1234低壓配電設(shè)備和列頭柜應(yīng)設(shè)置運行參數(shù)監(jiān)控和報警系統(tǒng),監(jiān)控不應(yīng)少于表4.2.71和4.2.72所列內(nèi)容,報警不應(yīng)少于表4.2.73和4.2.74所列內(nèi)容。表16123456表212表312345表412低壓配電設(shè)備和列頭柜日常巡檢不應(yīng)少于表4.2.81和4.2.82所列內(nèi)容。表112345表2123II不間斷電源和后備電源系統(tǒng)UPS(不間斷電源系統(tǒng))室和直流電源室溫度宜保持在20~30℃,相對濕7度應(yīng)保持在20%~80%,不得結(jié)露。UPS應(yīng)設(shè)置運行參數(shù)監(jiān)控和報警系統(tǒng),報警內(nèi)容應(yīng)包括當前報警和歷史報警,監(jiān)控不應(yīng)少于表4.2.10所列內(nèi)容。表1234UPS日常巡檢不應(yīng)少于表4.2.11所列內(nèi)容。表1234直流電源系統(tǒng)應(yīng)設(shè)置運行參數(shù)監(jiān)控和報警系統(tǒng),監(jiān)控不應(yīng)少于表4.2.12-1所列內(nèi)容,報警不應(yīng)少于表4.2.122所列內(nèi)容。表1123表2123直流電源日常巡檢不應(yīng)少于表4.2.13所列內(nèi)容。表12345蓄電池室溫度應(yīng)保持在20~30℃。蓄電池應(yīng)設(shè)置運行參數(shù)監(jiān)控系統(tǒng),監(jiān)控不宜少于表4.2.15所列內(nèi)容。表812蓄電池日常巡檢不應(yīng)少于表4.2.16所列內(nèi)容。表1234柴油發(fā)電機組運行對象應(yīng)包括發(fā)動機、發(fā)電機、控制系統(tǒng)、電氣系統(tǒng)、冷卻系統(tǒng)、燃油系統(tǒng)、潤滑系統(tǒng)、進排風系統(tǒng)和排煙系統(tǒng)。柴油發(fā)電機組日常巡檢不應(yīng)少于表4.2.18所列內(nèi)容。表12345678○○○○○注:日常巡檢內(nèi)容包括柴油發(fā)電機組待機和運轉(zhuǎn)兩種狀態(tài)下的日常巡檢內(nèi)”代表不同狀態(tài)下需要檢查內(nèi)容的選項標記。○III照明系統(tǒng)照明運行對象應(yīng)包括正常照明、備用照明和消防應(yīng)急照明。照明設(shè)備日常巡檢不應(yīng)少于表4.2.20所列內(nèi)容。表192344.3通風空調(diào)系統(tǒng)I冷源和水系統(tǒng)制冷機組、冷凍水泵、冷卻水泵、冷卻塔、電控水閥應(yīng)采取群控方式,根據(jù)系統(tǒng)負荷變化和機組特性制定運行策略。在滿足除濕和供冷需求的條件下,制冷機組供水溫度宜適當提高。具備冷卻塔供冷措施的空調(diào)系統(tǒng)在過渡季和冬季運行時,應(yīng)根據(jù)室外氣象條件進行自然供冷與冷機供冷模式的切換。采用變頻控制的水泵和冷卻塔風機,當電機無獨立散熱措施時,頻率不宜低于30Hz。當室外溫度低于冰點時,冷卻水系統(tǒng)應(yīng)采取防凍措施。冷源和水系統(tǒng)運行監(jiān)控不應(yīng)少于表4.3.6所列內(nèi)容。表1234泵率制冷機組應(yīng)進行日常巡檢,巡檢不應(yīng)少于表4.3.7所列內(nèi)容。表12冷卻塔應(yīng)進行日常巡檢,巡檢內(nèi)容應(yīng)包括風機有無異常聲響、飄水、漏水和冬季結(jié)冰情況檢查。水泵應(yīng)進行日常巡檢,巡檢不應(yīng)少于表4.3.9所列內(nèi)容。表12103空調(diào)水系統(tǒng)的定壓設(shè)施、補水箱、軟化水箱、管道、閥門附件應(yīng)進行日常巡檢,巡檢不應(yīng)少于表4.3.10所列內(nèi)容。表123II機房空調(diào)和風系統(tǒng)室內(nèi)氣流組織應(yīng)確保合理,防止局部過熱。運行策略應(yīng)根據(jù)氣象條件和運行環(huán)境變化適時調(diào)整,降低局部結(jié)露風險。設(shè)置了自然冷卻措施的機房空調(diào)和風系統(tǒng)在過渡季和冬季運行時,應(yīng)根據(jù)室外氣象條件進行自然供冷與壓縮機供冷模式的切換。采用變頻控制的風機,應(yīng)符合本標準第4.3.4條規(guī)定。機房空調(diào)和風系統(tǒng)監(jiān)控不應(yīng)少于表4.3.15所列內(nèi)容:表/12/停34機房空調(diào)和風系統(tǒng)應(yīng)進行日常巡檢,巡檢不應(yīng)少于表4.3.16所列內(nèi)容。表12空調(diào)風系統(tǒng)管道應(yīng)進行日常巡檢,檢查保溫層有無破損、結(jié)露。4.4消防系統(tǒng)消防控制室值班人員,應(yīng)按要求記錄消防控制室內(nèi)消防設(shè)備的運行情況,發(fā)現(xiàn)火警或設(shè)備故障時應(yīng)立即進行確認,并進行相關(guān)處理,必要時應(yīng)立即啟動相關(guān)應(yīng)急操作程序。11消防日常巡檢不應(yīng)少于表4.4.2所列內(nèi)容。表123456789數(shù)據(jù)中心區(qū)域內(nèi)的動火作業(yè)應(yīng)經(jīng)過批準,并采取防護措施。動火區(qū)域巡檢不應(yīng)少于表4.4.3所列內(nèi)容。表效1234.5智能化系統(tǒng)I環(huán)境和設(shè)備監(jiān)控系統(tǒng)環(huán)境和設(shè)備監(jiān)控系統(tǒng)應(yīng)設(shè)置合理的控制參數(shù)設(shè)定值和聯(lián)動控制邏輯,并在實際運行過程中進行優(yōu)化。對大型數(shù)據(jù)中心,可分區(qū)域進行電能使用效率分析,并結(jié)合環(huán)境監(jiān)控數(shù)據(jù)和氣流組織情況進行優(yōu)化。II安全防范系統(tǒng)數(shù)據(jù)中心區(qū)域應(yīng)根據(jù)重要等級和功能區(qū)劃分相應(yīng)的控制區(qū)域,出入權(quán)限應(yīng)實行分區(qū)、分級管理,對重要區(qū)域可設(shè)置多重認證措施。12各控制區(qū)域出入口宜制定視頻聯(lián)動控制方案,并根據(jù)需要適時調(diào)整。入侵報警系統(tǒng)宜制定視頻、照明聯(lián)動控制方案,并根據(jù)需要適時調(diào)整。入侵報警系統(tǒng)應(yīng)根據(jù)防護需要及時調(diào)整入侵探測器參數(shù)和狀態(tài)。視頻監(jiān)控系統(tǒng)應(yīng)制定使用方案,優(yōu)先顯示重點監(jiān)控對象。視頻監(jiān)控系統(tǒng)應(yīng)建立視頻輪巡機制,確保每路視頻信號在一定時間內(nèi)都能夠顯示在監(jiān)控屏幕上,及時發(fā)現(xiàn)視頻監(jiān)控故障。4.6環(huán)境參數(shù)主機房應(yīng)對冷通道或機柜進風區(qū)域的溫度和相對濕度進行在線監(jiān)測,溫度宜保持在18~27℃,相對濕度宜保持在35%~65%。主機房運行應(yīng)始終維持正壓,主機房與相鄰區(qū)域的壓差不宜小于1Pa。主機房壁面、設(shè)備表面結(jié)露情況應(yīng)進行日常巡檢,若出現(xiàn)結(jié)露現(xiàn)象,應(yīng)及時采取應(yīng)對措施。主機房運行期間宜定期檢測表4.6.4所列的環(huán)境參數(shù)。表升在和~)2主機房和輔助區(qū)的照度應(yīng)滿足運維監(jiān)控需求。有人值守的長期固定工作位置測量的噪聲值應(yīng)小于60dB(A)。有人值守的長期固定工作位置測量的室內(nèi)空氣中CO濃度不應(yīng)大于0.1%。2人員活動區(qū)的游離甲醛、苯、氨、氡和TVOC等空氣污染物濃度符合現(xiàn)行國家標準的相關(guān)規(guī)定。135維護5.1一般規(guī)定維護工作應(yīng)包括預(yù)防性維護、預(yù)測性維護和維修等內(nèi)容。基礎(chǔ)設(shè)施系統(tǒng)和設(shè)備應(yīng)進行標識,標識應(yīng)設(shè)置于顯著位置。保修期滿的設(shè)備應(yīng)采取措施確保維護保養(yǎng)服務(wù)的連續(xù)性?;A(chǔ)設(shè)施設(shè)備周圍應(yīng)保持整潔,無雜物堆放,確保維護維修通道通暢。數(shù)據(jù)中心維護管理人員應(yīng)定期對基礎(chǔ)設(shè)施系統(tǒng)和設(shè)備的運行狀態(tài)進行風險分析與評估,根據(jù)評估結(jié)果進行預(yù)測性維護。設(shè)有內(nèi)置時鐘的設(shè)備應(yīng)定期檢查并進行校準,與標準時間同步。環(huán)境和設(shè)備監(jiān)控系統(tǒng)、安全防范系統(tǒng)宜定期對數(shù)據(jù)進行備份,并對備份數(shù)據(jù)進行驗證。5.2電氣系統(tǒng)I供配電系統(tǒng)供配電設(shè)備維護操作應(yīng)遵守一人操作、一人監(jiān)護的原則。高壓供配電設(shè)備應(yīng)按照當?shù)毓╇姴块T要求定期進行檢測并出具報告。高壓供配電設(shè)備宜每年進行1次預(yù)防性維護,維護不應(yīng)少于表5.2.3所列內(nèi)容。表12345A級數(shù)據(jù)中心高壓供配電系統(tǒng)宜每半年進行1次供電中斷應(yīng)急演練,、C級數(shù)據(jù)中心依據(jù)自身需求確定。電力變壓器宜每年進行1次預(yù)防性維護,維護不應(yīng)少于表5.2.5所列內(nèi)容。表12314456低壓配電設(shè)備宜每年進行1次預(yù)防性維護,維護不應(yīng)少于表5.2.6所列內(nèi)容。表12345能678關(guān)9低壓配電柜體內(nèi)電纜、母排、接線端子、斷路器應(yīng)每半年進行1次溫度測量,并對比前次測量結(jié)果。II不間斷電源和后備電源系統(tǒng)UPS宜每年進行1次預(yù)防性維護,維護不應(yīng)少于表5.2.8所列內(nèi)容。表123456直流電源系統(tǒng)宜每年進行1次預(yù)防性維護,維護不應(yīng)少于表5.2.9所列內(nèi)容。表123415蓄電池宜每季度進行1次預(yù)防性維護,維護不應(yīng)少于表5.2.10所列內(nèi)容。表123456柴油發(fā)電機組應(yīng)每月進行1次預(yù)防性維護,維護不應(yīng)少于表5.2.11所列內(nèi)容。表12345柴油發(fā)電機組應(yīng)每年進行1次帶載測試,檢查機油壓力、冷卻液溫度、轉(zhuǎn)速、電氣工作狀態(tài)、負載均衡、ATS切換功能。柴油發(fā)電機組每2年或累計運行250h應(yīng)進行三濾、機油、冷凍液更換。III其他系統(tǒng)機房照度應(yīng)每年進行檢查。備用照明設(shè)備宜半年進行1次功能性檢查。配電線路布線系統(tǒng)宜每年進行1次預(yù)防性維護,維護不宜少于表5.2.16所列內(nèi)容。表123456母線槽連接處、電纜頭和電纜外皮應(yīng)每年進行不小于1次溫度檢查。16浪涌保護器宜定期進行功能檢查,對浪涌保護器的輸入開關(guān)進行通斷試驗。防雷與接地裝置的電氣連通性應(yīng)每年進行1次檢測。接閃器應(yīng)每年進行1次防銹、除銹維護。5.3通風空調(diào)系統(tǒng)I冷源和水系統(tǒng)制冷機組應(yīng)定期進行預(yù)防性維護,維護不應(yīng)少于表5.3.1所列內(nèi)容。表123季季月4年56季月78周季年年9水冷冷凝器、蒸發(fā)器應(yīng)根據(jù)端差進行預(yù)測性維護,板式換熱器應(yīng)根據(jù)運行溫差或壓差進行預(yù)測性維護,維護內(nèi)容應(yīng)符合表5.3.2規(guī)定。表123冷卻塔應(yīng)定期進行預(yù)防性維護,維護不應(yīng)少于表5.3.3所列內(nèi)容。表年1周23月季456年季年17水泵應(yīng)定期進行預(yù)防性維護,維護不應(yīng)少于表5.3.4所列內(nèi)容。表序號12月水泵電動機應(yīng)每半年進行1次預(yù)防性維護,維護不應(yīng)少于表5.3.5所列內(nèi)容。表1234水箱宜每月進行1次表面清潔,宜每月檢查1次供水浮球閥及進出閥門能否正常啟動、關(guān)閉,如有銹蝕、失靈應(yīng)及時更換。定壓補水裝置宜每月進行1次表面清潔和手自動切換檢查,應(yīng)每年檢查1次電磁閥、安全閥。水處理系統(tǒng)宜每季度進行1次預(yù)防性維護,維護不應(yīng)少于表5.3.8所列內(nèi)容。表1234空調(diào)水系統(tǒng)閥門、管道宜每半年進行1次預(yù)防性維護,維護不應(yīng)少于表5.3.9所列內(nèi)容。表12II機房空調(diào)和風系統(tǒng)新風機組、組合式空調(diào)機組、風機盤管應(yīng)定期進行預(yù)防性維護,維護不18應(yīng)少于表5.3.10所列內(nèi)容。表122345年季新風機組、組合式空調(diào)機組空氣過濾器應(yīng)根據(jù)壓差進行預(yù)測性維護,表冷器應(yīng)根據(jù)運行溫差或壓差進行預(yù)測性維護,維護內(nèi)容應(yīng)符合表5.3.11規(guī)定。表12新風機組和組合式空調(diào)機組風機電機應(yīng)每季度檢查1次電機傳動皮帶,根據(jù)情況及時調(diào)整或更換,其他維護內(nèi)容應(yīng)符合本標準表5.3.5的規(guī)定。空調(diào)風系統(tǒng)閥門、管道、風口宜每年進行1次預(yù)防性維護,維護不應(yīng)少于表5.3.13所列內(nèi)容。表123事故排風系統(tǒng)應(yīng)每半年進行1次功能性測試。直接膨脹式和冷凍水型機房空調(diào)應(yīng)定期進行預(yù)防性維護,維護不應(yīng)少于表5.3.15所列內(nèi)容。表季12345季年季年678季季年19機房漏水報警裝置應(yīng)每半年進行1次有效性檢查,同時確保排水系統(tǒng)暢通。5.4消防系統(tǒng)數(shù)據(jù)中心消防系統(tǒng)應(yīng)按照《建筑消防設(shè)施的維護管理》GB25201要求進行年度檢測。消防系統(tǒng)有效性宜定期委托有資質(zhì)的專業(yè)機構(gòu)進行評估?;馂?zāi)自動報警系統(tǒng)應(yīng)定期進行預(yù)防性維護,維護內(nèi)容和周期應(yīng)符合現(xiàn)行消防國家標準的相關(guān)規(guī)定。消防水源、消防水泵、閥門、倒流防止器、消火栓、水泵接合器、過濾器等消防給水設(shè)施應(yīng)定期進行預(yù)防性維護,維護內(nèi)容和周期應(yīng)符合現(xiàn)行國家標準《消防給水及消火栓系統(tǒng)技術(shù)規(guī)范》GB50974的相關(guān)規(guī)定。自動噴水滅火系統(tǒng)的管線、閥門和控制功能等應(yīng)定期進行預(yù)防性維護,維護的周期和內(nèi)容用應(yīng)符合《自動噴水滅火系統(tǒng)施工及驗收規(guī)范》GB50261、《細水霧滅火系統(tǒng)技術(shù)規(guī)范》GB50898的相關(guān)規(guī)定。氣體滅火系統(tǒng)及氣體探火管滅火系統(tǒng)應(yīng)定期進行預(yù)防性維護。防排煙系統(tǒng)應(yīng)定期進行預(yù)防性維護。防火卷簾、防火門、防火窗等防火分隔設(shè)施應(yīng)定期進行預(yù)防性維護,維護的周期和內(nèi)容應(yīng)符合《防火卷簾、防火門、防火窗施工及驗收規(guī)范》50877的相關(guān)規(guī)定。GB防火封堵系統(tǒng)應(yīng)結(jié)合防火封堵產(chǎn)品的要求進行預(yù)防性維護。消防應(yīng)急照明與疏散指示系統(tǒng)應(yīng)定期進行預(yù)防性維護。消防應(yīng)急廣播系統(tǒng)應(yīng)定期進行預(yù)防性維護,維護的內(nèi)容和周期應(yīng)符合《火災(zāi)自動報警系統(tǒng)施工及驗收規(guī)范》GB50166的相關(guān)規(guī)定。建筑滅火器應(yīng)定期進行預(yù)防性維護,維護內(nèi)容和周期應(yīng)符合現(xiàn)行消防國家標準《建筑滅火器配置驗收及檢查規(guī)范》GB50444的相關(guān)規(guī)定。空氣(氧氣)呼吸器應(yīng)每年進行1次預(yù)防性維護,檢查配置數(shù)量和有效期。205.5智能化系統(tǒng)I環(huán)境和設(shè)備監(jiān)控系統(tǒng)環(huán)境和設(shè)備監(jiān)控系統(tǒng)應(yīng)每半年進行1次預(yù)防性維護,維護不應(yīng)少于表5.5.1內(nèi)容:表1233456環(huán)境和設(shè)備監(jiān)控系統(tǒng)維護過程中,應(yīng)采取必要的保護措施,確保被監(jiān)控系統(tǒng)與設(shè)備正常工作。II安全防范系統(tǒng)出入口控制系統(tǒng)應(yīng)每半年進行1次預(yù)防性維護,維護不應(yīng)少于表5.5.3所列內(nèi)容。表12345678入侵報警系統(tǒng)應(yīng)每半年進行1次預(yù)防性維護,維護不應(yīng)少于表5.5.4內(nèi)容:表1234562178視頻監(jiān)控系統(tǒng)應(yīng)每半年進行一次預(yù)防性維護,維護不應(yīng)少于表5.5.5所列內(nèi)容:表123456789226制度6.1一般規(guī)定運行維護團隊應(yīng)制定運行維護愿景和管理目標,并建立完整的運行維護管理制度和程序。運行維護管理應(yīng)明確物理范圍及邊界,并建立與周邊設(shè)施的協(xié)調(diào)機制及責權(quán)界限。運行維護團隊應(yīng)明確管理組織架構(gòu)和職責。運行維護團隊應(yīng)根據(jù)職責、工作范圍和工作任務(wù)配備相應(yīng)的人力、財務(wù)、物資和辦公資源。6.2制度體系運行維護制度體系應(yīng)包括安全管理、運行維護管理、質(zhì)量管理、應(yīng)急管理、能效管理、人力資源管理、財務(wù)管理、文件管理、績效管理、合規(guī)管理。安全管理內(nèi)容應(yīng)包括人員安全、職業(yè)健康、環(huán)境安全、信息安全。運行維護管理內(nèi)容應(yīng)包括監(jiān)控管理、值班管理、巡檢管理、作業(yè)管理、供應(yīng)商管理、資產(chǎn)管理、變更管理、容量管理、事件管理和問題管理。質(zhì)量管理內(nèi)容應(yīng)包括質(zhì)量保證、質(zhì)量控制和持續(xù)改進。應(yīng)急管理內(nèi)容應(yīng)包括風險識別、風險評估、預(yù)案制定、應(yīng)急演練。能效管理內(nèi)容應(yīng)包括能效數(shù)據(jù)的獲取、分析和運行方案的優(yōu)化。人力資源管理內(nèi)容應(yīng)包括人員的選擇、培養(yǎng)、使用和發(fā)展規(guī)劃。財務(wù)管理內(nèi)容應(yīng)包括預(yù)算編制、預(yù)算執(zhí)行、核算和成本分析。文件管理內(nèi)容應(yīng)包括文件編制、審核、批準、發(fā)布、使用、歸檔、變更、廢止和銷毀??冃Ч芾韮?nèi)容應(yīng)包括績效目標制定和分解、績效監(jiān)控和評價、績效結(jié)果的應(yīng)用。合規(guī)管理內(nèi)容應(yīng)包括合規(guī)要求的識別、合規(guī)評估和處置。23本標準用詞說明1為便于在執(zhí)行本標準條文時區(qū)別對待,對要求嚴格程度不同的用詞說明如下:1)表示很嚴格,非這樣做不可的:2)表示嚴格,在正常情況下均應(yīng)這樣做的:3)表示允許稍有選擇,在條件許可時首先應(yīng)這樣做的:4)2……的規(guī)定”或“應(yīng)按……24引用標準名錄1234567《建筑消防設(shè)施的維護管理》GB25201《消防給水及消火栓系統(tǒng)技術(shù)規(guī)范》GB50974《自動噴水滅火系統(tǒng)施工及驗收規(guī)范》GB50261《細水霧滅火系統(tǒng)技術(shù)規(guī)范》GB50898《防火卷簾、防火門、防火窗施工及驗收規(guī)范》GB50877《火災(zāi)自動報警系統(tǒng)施工及驗收規(guī)范》GB50166《建筑滅火器配置驗收及檢查規(guī)范》GB5044425《數(shù)據(jù)中心設(shè)施運行維護標準》條文說明中華人民共和國國家標準條文說明26《數(shù)據(jù)中心設(shè)施運行維護標準》條文說明目次1總則.........................................................................................................................272術(shù)語.........................................................................................................................293基本規(guī)定.................................................................................................................303.1運行維護范圍...................................................................................................293.2運行維護基本要求...........................................................................................304運行.........................................................................................................................324.1一般規(guī)定...........................................................................................................324.2電氣系統(tǒng)...........................................................................................................324.3通風空調(diào)系統(tǒng)...................................................................................................334.4消防系統(tǒng)...........................................................................................................344.5智能化系統(tǒng).......................................................................................................354.6環(huán)境參數(shù)...........................................................................................................355維護.........................................................................................................................395.1一般規(guī)定...........................................................................................................395.2電氣系統(tǒng)...........................................................................................................395.3通風空調(diào)系統(tǒng)...................................................................................................395.4消防系統(tǒng)...........................................................................................................415.5智能化系統(tǒng).......................................................................................................446制度..........................................................................................................................466.1一般規(guī)定...........................................................................................................466.2制度體系...........................................................................................................4627《數(shù)據(jù)中心設(shè)施運行維護標準》條文說明1總則1.0.1隨著大數(shù)據(jù)時代的到來,數(shù)據(jù)中心的發(fā)展出現(xiàn)了全新的局面。數(shù)據(jù)中心的數(shù)量和規(guī)模不斷擴大,所面臨的管理與維護問題也越來越多,一旦出現(xiàn)管理不到位,或者運行維護不及時的情況,就可能對業(yè)務(wù)帶來不可估量的損失。因此,精細化的運行維護管理已成為數(shù)據(jù)中心運行中不可或缺的重要一環(huán)。1.0.2運行維護工作主要存在于已進入正常使用階段的數(shù)據(jù)中心中,數(shù)據(jù)中心交付運行維護團隊前,應(yīng)為運行維護團隊順利接手進行必要的準備工作。28《數(shù)據(jù)中心設(shè)施運行維護標準》條文說明2術(shù)語2.0.1本術(shù)語定義與《數(shù)據(jù)中心設(shè)計規(guī)范》GB50174保持一致。2.0.2本術(shù)語定義與《數(shù)據(jù)中心設(shè)計規(guī)范》GB50174保持一致。2.0.3運行系指對數(shù)據(jù)中心基礎(chǔ)設(shè)施系統(tǒng)和設(shè)備進行的日常操作與狀態(tài)監(jiān)測,本標準將日常巡檢界定為運行范疇,而將其他的周期性巡檢界定為維護范疇。運行的目的是確保電子信息設(shè)備運行環(huán)境的穩(wěn)定可靠,在此基礎(chǔ)上,數(shù)據(jù)中心基礎(chǔ)設(shè)施系統(tǒng)與設(shè)備自身的安全高效運行也必須得到保障。2.0.4在本標準中,將維護的內(nèi)容界定為預(yù)防性維護、預(yù)測性維護和維修,維修在國際上也有“糾正性維護”的叫法。2.0.5預(yù)防性維護是以預(yù)防故障和功能退化為目的,對設(shè)備進行檢查、檢測、保養(yǎng),以確保數(shù)據(jù)中心基礎(chǔ)設(shè)施系統(tǒng)和設(shè)備保持規(guī)定功能狀態(tài)所進行的各種周期性維護活動。2.0.6預(yù)測性維護是以運行狀態(tài)為依據(jù)的維修與維護。在設(shè)備或系統(tǒng)運行時,對它的主要部位進行定期或連續(xù)的狀態(tài)監(jiān)測和故障診斷,判定設(shè)備或系統(tǒng)所處的狀態(tài),預(yù)測其未來發(fā)展趨勢,針對可能發(fā)生的故障進行維護活動。預(yù)測性維護是構(gòu)成維護工作的內(nèi)容之一,但作為針對特定情況的維護活動,除制度一章有所要求外,在本標準中不對其具體工作內(nèi)容進行規(guī)定。2.0.7事件是發(fā)生在數(shù)據(jù)中心基礎(chǔ)設(shè)施運行維護過程中的任何計劃外的、不尋常的或者意外的事態(tài)。事件一般包括:1直接和立即影響數(shù)據(jù)中心基礎(chǔ)設(shè)施功能性的事態(tài);2危及數(shù)據(jù)中心基礎(chǔ)設(shè)施正常運行的設(shè)備或者服務(wù)的故障。29《數(shù)據(jù)中心設(shè)施運行維護標準》條文說明3基本規(guī)定3.1運行維護范圍3.1.1本標準確定的運行維護范圍是直接服務(wù)于電子信息設(shè)備的基礎(chǔ)設(shè)施系統(tǒng)與設(shè)備,不包含一般性的建筑維護內(nèi)容。給水排水系統(tǒng)有關(guān)內(nèi)容分散于通風空調(diào)系統(tǒng)與消防系統(tǒng)中。3.1.2本條所述供配電系統(tǒng)包括高壓供配電系統(tǒng)、低壓配電系統(tǒng)和變壓器,不間斷電源和后備電源系統(tǒng)系統(tǒng)包括UPS、直流電源系統(tǒng)、柴油發(fā)電機系統(tǒng),配電線路布線系統(tǒng)主要內(nèi)容為電纜和母線槽。3.1.3通風空調(diào)系統(tǒng)子系統(tǒng)的劃分,設(shè)計人員和一線運行維護人員的習慣不同,為兼顧二者并具有一定的條理性,本標準對通風空調(diào)子系統(tǒng)進行了較為宏觀的分類,分為了冷源和水系統(tǒng)、機房空調(diào)和風系統(tǒng)兩大類。本標準主要涉及了常用的冷凍水型和直接膨脹式空調(diào)系統(tǒng),其他類型系統(tǒng)可參考相關(guān)運行維護內(nèi)容。3.1.5按照《數(shù)據(jù)中心設(shè)計規(guī)范》GB501742017的規(guī)定,智能化系統(tǒng)包括總控中心、環(huán)境和設(shè)備監(jiān)控系統(tǒng)、安全防范系統(tǒng)、火災(zāi)自動報警系統(tǒng)、數(shù)據(jù)中心基礎(chǔ)設(shè)施管理系統(tǒng)等智能化系統(tǒng)。根據(jù)運行維護工作的特點,本標準智能化系統(tǒng)部分重點關(guān)注環(huán)境和設(shè)備監(jiān)控系統(tǒng)和安全防范系統(tǒng),火災(zāi)自動報警系統(tǒng)相關(guān)內(nèi)容在消防系統(tǒng)部分進行規(guī)定。3.2運行維護基本要求3.2.1運行維護團隊參與基礎(chǔ)設(shè)施系統(tǒng)和設(shè)備安裝、調(diào)試和驗證的過程,有利于對系統(tǒng)和設(shè)備情況的了解與掌握,在條件允許的情況下宜及早介入。3.2.2數(shù)據(jù)中心正式投入使用前,應(yīng)模擬運行或故障場景以驗證系統(tǒng)功能和性能是否達到設(shè)計要求。3.2.4《數(shù)據(jù)中心設(shè)計規(guī)范》GB50174將數(shù)據(jù)中心分為、、C三級,本標準的數(shù)據(jù)中心分級采用相應(yīng)的分級標準。3.2.6數(shù)據(jù)中心投入使用后,再進行綜合系統(tǒng)測試有一定風險隱患,但應(yīng)定期對關(guān)鍵系統(tǒng)進行測試,根據(jù)實施條件各系統(tǒng)可單獨測試也可進行聯(lián)動測試,一般宜結(jié)合應(yīng)急演練進行。30《數(shù)據(jù)中心設(shè)施運行維護標準》條文說明3.2.7運行維護過程中,通過日常巡檢、維護檢查、系統(tǒng)監(jiān)測等各種方式發(fā)現(xiàn)的隱患、異常、故障、報警等問題,應(yīng)及時采取應(yīng)對措施。3.2.8基礎(chǔ)設(shè)施系統(tǒng)與設(shè)備維護保養(yǎng)、發(fā)生故障及維修期間,不能正常發(fā)揮作用,在此期間的突發(fā)狀況系統(tǒng)無法應(yīng)對,因此應(yīng)制定相應(yīng)的保障措施和應(yīng)急預(yù)案。3.2.9運行維護人員技能素質(zhì)對數(shù)據(jù)中心安全、穩(wěn)定、可靠運行有至關(guān)重要的作用,對不同的崗位應(yīng)有各自的從業(yè)資格要求,例如:低壓巡檢人員應(yīng)具有低壓電工證,高壓巡檢人員應(yīng)具有高壓進網(wǎng)許可證,消防運行維護人員可參照129號)的相關(guān)要求。31《數(shù)據(jù)中心設(shè)施運行維護標準》條文說明4運行4.1一般規(guī)定4.1.2本條規(guī)定了運行維護值班的時間要求,消防控制室的值班應(yīng)按國家有關(guān)法規(guī)要求執(zhí)行。4.1.4本條規(guī)定是為了使運行人員能夠及時發(fā)現(xiàn)問題和隱患,最大限度地降低事故發(fā)生率。巡檢記錄包括報警、問題及處理情況。4.1.5本條對現(xiàn)場巡檢次數(shù)進行了規(guī)定,主要針對遠程監(jiān)控無法識別的異常聲響、氣味、振動、痕跡等情況,同時對遠程監(jiān)控系統(tǒng)進行校驗,可以由人工,也可以由機器人等技術(shù)手段完成。4.1.7電能使用效率是數(shù)據(jù)中心最為關(guān)注的能效參數(shù),應(yīng)持續(xù)監(jiān)測數(shù)據(jù)中心各部分能耗,統(tǒng)計分析數(shù)據(jù)中心電能使用效率。通過優(yōu)化運行可有效降低電氣系統(tǒng)和通風空調(diào)系統(tǒng)能耗,從而提高整體電能使用效率。電氣系統(tǒng)應(yīng)根據(jù)負載情況調(diào)整運行策略;通風空調(diào)系統(tǒng)應(yīng)根據(jù)氣候條件、動態(tài)負荷及能源供應(yīng)等條件,經(jīng)技術(shù)經(jīng)濟比較,按安全可靠、節(jié)能環(huán)保的原則,制定合理的全年運行策略。4.1.8輪換使用可有效延長設(shè)備壽命,同時保持備用設(shè)備的正常狀態(tài)。4.2電氣系統(tǒng)I供配電系統(tǒng)4.2.1關(guān)于高壓有不同的規(guī)定,本標準中高壓系指交流400V以上的電壓等級。4.2.2配電室或值班室內(nèi)設(shè)置數(shù)據(jù)中心供配電系統(tǒng)圖,對幫助值班人員快速掌握數(shù)據(jù)中心供電關(guān)系、方便討論運行過程中遇到的問題、輔助判斷故障原因等都有積極作用。系統(tǒng)圖可以固定在高壓配電室或值班室明顯位置。對于設(shè)有高壓開閉站的大中型數(shù)據(jù)中心宜設(shè)置模擬屏。4.2.3本條文規(guī)定為了幫助判斷設(shè)備重要性等級、提高運行維護效率。4.2.4本條規(guī)定了高壓配電設(shè)備巡視檢查的內(nèi)容,這些巡檢內(nèi)容能反映出設(shè)備是否正常運行。通過巡檢及早發(fā)現(xiàn)運行中的異常,及時處理,避免引發(fā)重大事故。32《數(shù)據(jù)中心設(shè)施運行維護標準》條文說明II不間斷和后備電源系統(tǒng)4.2.9本條溫濕度參考了《數(shù)據(jù)中心設(shè)計規(guī)范》GB501742017和產(chǎn)品手冊要求的參數(shù)范圍,直流電源系統(tǒng)指電壓等級為直流48V、240V、336V的系統(tǒng)。溫度條件在設(shè)備允許的情況下可適當放寬,有利于空調(diào)系統(tǒng)節(jié)能運行,故用4.2.14本條蓄電池指UPS蓄電池、直流電源蓄電池,不包括其它蓄電池。蓄電池室溫度采用了《數(shù)據(jù)中心設(shè)計規(guī)范》GB501742017要求的參數(shù)。4.2.15A級數(shù)據(jù)中心應(yīng)對每一節(jié)蓄電池進行監(jiān)控,B級、C級數(shù)據(jù)中心一般對每一組蓄電池進行監(jiān)控。4.2.17本條運行對象為固定式柴油發(fā)電機組。III照明系統(tǒng)4.2.19一般情況下,應(yīng)急照明包括備用照明,但對數(shù)據(jù)中心而言,主機房和輔助區(qū)備用照明較為重要,在《數(shù)據(jù)中心設(shè)計規(guī)范》GB501742017中對備用照明設(shè)置有明確規(guī)定,本條將其單獨列出。同時為便于區(qū)分,將“消防應(yīng)急照明”列為運行對象,特指為人員疏散和消防作業(yè)提供的照明。4.2.20照度要求在有人工作時光線充足,無人工作時滿足視頻監(jiān)控要求。4.3通風空調(diào)系統(tǒng)I空調(diào)水系統(tǒng)4.3.1冷機、冷凍水泵、冷卻水泵、冷卻塔、電控水閥需協(xié)調(diào)工作,其啟停順序、臺數(shù)控制、變頻調(diào)節(jié)、水閥開關(guān)和開度直接關(guān)系到系統(tǒng)安全與能效。機房群控是以機房總能耗最小為控制目標的節(jié)能運行方式,采用自動控制系統(tǒng)對各設(shè)備進行聯(lián)合控制,實現(xiàn)協(xié)同運行。4.3.2制冷機組出水溫度的設(shè)定值是為了滿足除濕和供冷需求,制冷系統(tǒng)在全年動態(tài)運行過程中,絕大部分時間處于非設(shè)計工況,在滿足需求的前提下,提高制冷機組的出水溫度可以大大提高機組效率。4.3.3數(shù)據(jù)中心冷負荷穩(wěn)定,需全年供冷。在過渡季和冬季,室外氣象條件適合時,可減少制冷機組運行,采用冷卻塔供冷方式,有利于降低空調(diào)系統(tǒng)能耗,33《數(shù)據(jù)中心設(shè)施運行維護標準》條文說明達到節(jié)能的目的。4.3.4水泵和冷卻塔風機變頻可在保證需求的前提下降低電機功耗,頻率越低節(jié)能效果越好,但對于電機沒有獨立散熱措施的情況,頻率過低會影響設(shè)備安全性,根據(jù)實際工程經(jīng)驗運行頻率一般不宜低于30Hz。4.3.5在嚴寒和寒冷地區(qū)冬季運行的冷卻水系統(tǒng)需要采取可靠的防凍措施,外露的閥門管道需要做好保溫,必要時在管道加裝電伴熱帶,開式冷卻塔集水盤設(shè)置電加熱器。4.3.7此處的制冷機組包含了水冷冷水機組、風冷冷水機組、吸收式冷水機組。II機房空調(diào)和風系統(tǒng)4.3.11氣流組織是經(jīng)過凈化和熱濕處理的空氣從進入房間到離開房間過程中在空間上的分布狀態(tài),如果氣流組織不合理,不能保證足夠的風量送達發(fā)熱點,則會造成局部過熱現(xiàn)象,可通過調(diào)節(jié)送回風量、送風方向等措施解決。4.3.12室外氣象條件的急劇變化、室內(nèi)冷負荷的變化,都有可能引起局部結(jié)露。結(jié)露往往出現(xiàn)在冷橋部位、送風口等部位。除做好針對性的保溫措施外,還應(yīng)從系統(tǒng)運行策略角度控制結(jié)露風險,如:控制新風處理參數(shù)、控制送風參數(shù)、適時開啟除濕機等。4.3.13對于設(shè)有全新風運行措施的風系統(tǒng)、氟泵系統(tǒng)、帶乙二醇干式冷卻器/乙二醇(或水)自然循環(huán)節(jié)能冷卻器的機房空調(diào),均應(yīng)在室外氣象條件適合時,進行自然供冷和壓縮機供冷模式的切換。4.3.15一般情況下,設(shè)備廠商能夠提供常用的監(jiān)控信息,對于采用第三方專業(yè)監(jiān)控系統(tǒng)的,可根據(jù)項目實際需求增加運行監(jiān)控內(nèi)容。上表中的報警包含了各種主要的保護報警:高低壓報警、氣流故障報警、溫濕度過高/過低報警、電加熱高溫報警、加濕器報警、濾網(wǎng)淤塞報警、系統(tǒng)斷水、漏水報警、電源故障報警等。4.4消防系統(tǒng)4.4.1消防控制室內(nèi)設(shè)置的消防設(shè)備應(yīng)包括:火災(zāi)報警控制器、消防聯(lián)動控制器、消防控制室圖形顯示裝置、消防電話總機、消防應(yīng)急廣播控制裝置、消防應(yīng)急照明和疏散指示系統(tǒng)控制裝置、消防電源監(jiān)控器等設(shè)備,或具有相應(yīng)功能34《數(shù)據(jù)中心設(shè)施運行維護標準》條文說明的組合設(shè)備。消防控制室的管理、值班記錄及應(yīng)急操作程序,應(yīng)符合《建筑消防設(shè)施的維護管理GB252012010)與《消防控制室通用技術(shù)要求》(GB255062010)的規(guī)定。對于火災(zāi)隱患的極早期探測,宜配置便攜式極早期火災(zāi)定位器,以便簡單、快速發(fā)現(xiàn)火災(zāi)隱患點,并及時采取消除措施,最大限度地減少損失。采用氣體滅火系統(tǒng)的數(shù)據(jù)中心,宜配置消防鋼瓶爆裂預(yù)警探測系統(tǒng),以實時在線監(jiān)測消防鋼瓶自身的安全狀態(tài)。4.4.2本條提出的消防巡檢周期和內(nèi)容是基本要求,各單位可結(jié)合工作、生產(chǎn)、經(jīng)營等實際情況適當增加巡檢周期和內(nèi)容。本條所列巡檢內(nèi)容主要參考以下標準:1)《建筑消防設(shè)施的維護管理》GB2520120102)《消防控制室通用技術(shù)要求》GB2550620103)《火災(zāi)自動報警系統(tǒng)施工及驗收規(guī)范》GB5016620074)《火災(zāi)探測報警產(chǎn)品的維修保養(yǎng)與報廢》GB2983720135)《消防給水及消火栓系統(tǒng)技術(shù)規(guī)范》GB509746)《自動噴水滅火系統(tǒng)施工及驗收規(guī)范》GB5026120057)《氣體滅火系統(tǒng)施工及驗收規(guī)范》GB20078)《細水霧滅火系統(tǒng)技術(shù)規(guī)范》GB5089820139)《防火卷簾、防火門、防火窗施工及驗收規(guī)范》GB5087710)11)《建筑滅火器配置驗收及檢查規(guī)范》GB504444.4.3動火作業(yè)的火災(zāi)危險性較大,應(yīng)該是巡查的重點。動火作業(yè)應(yīng)有嚴格的審批制度;動火作業(yè)過程中,應(yīng)保證配套消防設(shè)施和措施到位,現(xiàn)場監(jiān)管人員嚴格落實相應(yīng)管理制度;動火作業(yè)完成應(yīng)恢復(fù)作業(yè)區(qū)域。對經(jīng)過批準的動火作業(yè),在動火期間應(yīng)加強對動火區(qū)域的巡檢。巡檢發(fā)現(xiàn)的問題應(yīng)立刻上報外,并責令動火人即刻糾正,未糾正前應(yīng)責令停止動火作業(yè)。4.5智能化系統(tǒng)I環(huán)境和設(shè)備監(jiān)控系統(tǒng)35《數(shù)據(jù)中心設(shè)施運行維護標準》條文說明4.5.1環(huán)境和設(shè)備監(jiān)控系統(tǒng)運行參數(shù)和控制邏輯是機房環(huán)境穩(wěn)定可靠和通風空調(diào)系統(tǒng)、電氣系統(tǒng)安全高效運行的保證,應(yīng)根據(jù)相關(guān)標準由專業(yè)人員設(shè)置,并在運行過程中根據(jù)實際情況和使用管理要求進行優(yōu)化。運行參數(shù)設(shè)定值和聯(lián)動邏輯的修改應(yīng)遵循變更管理程序,并設(shè)置相應(yīng)權(quán)限,禁止擅自修改。4.5.21)數(shù)據(jù)中心因為IT設(shè)備類型和IT業(yè)務(wù)量的不同,不同區(qū)域的電能使用效率可能會有較大差異。2)使用效率可和服務(wù)器負載、網(wǎng)絡(luò)流量等IT業(yè)務(wù)量綜合分析,建立多層次的評價體系。II安全防范系統(tǒng)4.5.3系統(tǒng)授權(quán)的審批、設(shè)置和執(zhí)行應(yīng)由互相獨立的崗位完成。應(yīng)對門禁系統(tǒng)的授權(quán)進行核查,建立機制,確保使用人不再需要時,能夠及時撤消門禁授權(quán)。4.5.4出入口的視頻監(jiān)控宜與門禁系統(tǒng)聯(lián)動控制,當有刷卡事件發(fā)生時,確保相應(yīng)的視頻圖像切換至監(jiān)控屏幕。4.5.5入侵報警系統(tǒng)宜與視頻監(jiān)控系統(tǒng)和燈光控制系統(tǒng)聯(lián)動控制,當有入侵事件發(fā)生時,確保開啟相應(yīng)區(qū)域照明,并將對應(yīng)視頻圖像切換至監(jiān)控屏幕。4.5.6調(diào)整探測器的靈敏度、探測范圍、探測角度,確保設(shè)備處在最好狀態(tài)或保持應(yīng)有效果。4.5.7視頻監(jiān)控系統(tǒng)重點監(jiān)控對象可根據(jù)需要適時調(diào)整,相關(guān)調(diào)整應(yīng)按照標準規(guī)范、技術(shù)手冊和使用管理要求,不得影響監(jiān)控效果。視頻監(jiān)控系統(tǒng)應(yīng)建立視頻輪巡機制,確保每路視頻信號在一定時間內(nèi)都能夠顯示在監(jiān)控屏幕上,及時發(fā)現(xiàn)視頻監(jiān)控故障。4.6環(huán)境參數(shù)4.6.1溫度和濕度是保證電子信息設(shè)備正常工作的重要環(huán)境指標,需要控制在一定范圍內(nèi)。雖然電子信息設(shè)備芯片對溫度的耐受范圍較大,但其工作溫濕度會對其壽命產(chǎn)生影響,長時間工作在不合理的溫濕度水平下會不同程度的降低其壽命及可靠性。本標準的溫度數(shù)值參考國家標準《數(shù)據(jù)中心設(shè)計規(guī)范》GB501742017,18~27℃的溫度范圍是綜合考慮暖通系統(tǒng)運行能耗、電子信息設(shè)備維修費用等各種因素而提出的。在空氣濕度方面,相對濕度過高會影響數(shù)據(jù)中心設(shè)備的安全運行與設(shè)備使36《數(shù)據(jù)中心設(shè)施運行維護標準》條文說明用壽命;而相對濕度過低時,可能導致靜電充電,進而損壞設(shè)備或影響其正常運行。國家標準《數(shù)據(jù)中心設(shè)計規(guī)范》GB501742017規(guī)定了露點溫度與相對GB/T28872011中對B級機房的相對濕度規(guī)定為35%~65%??紤]到數(shù)據(jù)中心空氣濕度的在線監(jiān)測多為相對濕度、而非露點溫度,故本條提出了建議相對濕度范圍。結(jié)合調(diào)研,考慮到全國范圍適用性,本標準推薦相對濕度采用35%-65%的范圍。4.6.2主機房維持正壓的目的是為了防止外部空氣進入主機房,以減少主機房外部空氣溫濕度及顆粒物對主機房室內(nèi)環(huán)境的影響。從實際運行角度,只要主機房保持對相鄰區(qū)域的正壓即可滿足上述要求。4.6.3數(shù)據(jù)中心需要嚴格避免發(fā)生結(jié)露現(xiàn)象。結(jié)露產(chǎn)生的水就可能毀壞電子元件,帶來嚴重后果。4.6.5機房中會經(jīng)常有工作人員進行調(diào)試、檢測、維護等技術(shù)操作,在進行技術(shù)操作期間,機房內(nèi)需滿足此類技術(shù)操作所要求的照度水平,在其他無人員操作時間,機房內(nèi)需滿足系統(tǒng)監(jiān)控所要求的照度水平。4.6.6為了保護工作人員的聽力與健康,對于有人值守的主機房和輔助區(qū)且在長期固定工作位置的噪聲值進行限制。限值參考國家標準《數(shù)據(jù)中心設(shè)計規(guī)范》GB501742017的規(guī)定。4.6.7本條滿足現(xiàn)行國家標準《室內(nèi)空氣質(zhì)量標準》GB18883中關(guān)于室內(nèi)空氣中二氧化碳日平均濃度的規(guī)定。數(shù)據(jù)中心雖然是以信息設(shè)備為主要服務(wù)對象的,但像控制室、值班室等有人長時間值守的區(qū)域應(yīng)該滿足符合人員健康要求的最基本衛(wèi)生標準。4.6.8數(shù)據(jù)中心雖然是以電子信息設(shè)備為主要服務(wù)對象的,但也有少量操作人員、測試人員、值班人員等,因此也應(yīng)該滿足室內(nèi)污染物濃度的要求。氡、甲醛、苯、氨、總揮發(fā)性有機物等五類物質(zhì)污染物的濃度限量應(yīng)符合現(xiàn)行國家標準《室內(nèi)空氣質(zhì)量標準》GB/T18883的要求,詳見下表。表1333111苯CH6637《數(shù)據(jù)中心設(shè)施運行維護標準》條文說明338氡38《數(shù)據(jù)中心設(shè)施運行維護標準》條文說明5維護5.1一般規(guī)定5.1.3在實際操作過程中,很多運行維護單位對保修期滿的設(shè)備,沒有及時采取應(yīng)對措施,導致兩個維保周期間出現(xiàn)空白期,需要延續(xù)維護保養(yǎng)服務(wù)的,應(yīng)及時購買。5.1.6各設(shè)備內(nèi)置時鐘隨著時間推移會產(chǎn)生誤差,為了保證設(shè)備報警時間與事件處理的一致性,需要定期校準時間。5.2電氣系統(tǒng)I高低壓供配電系統(tǒng)5.2.1由于供配電設(shè)備操作的風險性,對重要的操作和維護有特殊的規(guī)定和要求,因此應(yīng)遵守國家、行業(yè)和地區(qū)相關(guān)安全法規(guī)和標準的規(guī)定。5.2.2各地供電部門對于高壓供配電設(shè)備的檢測時間和內(nèi)容有不同的要求,應(yīng)按當?shù)毓╇姴块T要求執(zhí)行。一般檢測內(nèi)容宜符合表2規(guī)定。表21234567895.2.3本條規(guī)定了高壓配電設(shè)備的預(yù)防性維護時間和內(nèi)容,一般宜按本標準第5.2.2條的規(guī)定并結(jié)合供電部門檢測進行。維護內(nèi)容中,絕緣管材包括穿墻套管材料、絕緣板、電纜頭封包材料、互感器絕緣材料等。39《數(shù)據(jù)中心設(shè)施運行維護標準》條文說明5.2.5本條規(guī)定了電力變壓器的預(yù)防性維護周期和內(nèi)容。維護內(nèi)容中,接地檢查指檢查中性點和保護接地有無銹蝕、氧化、接地是否良好、端子有無松動。II不間斷電源和備用電源系統(tǒng)5.2.12本條規(guī)定了柴油發(fā)電機的帶載測試周期和內(nèi)容,驗證柴油發(fā)電機組的帶載能力、切換邏輯和負載均衡。帶載測試時,應(yīng)采取必要的防護措施,避免高溫觸發(fā)消防自動噴淋系統(tǒng)。III其他系統(tǒng)5.2.15對于備用照明的“功能性檢查”主要檢查照明設(shè)備是否能夠點亮。消防應(yīng)急照明應(yīng)按本標準第5.4.10條規(guī)定執(zhí)行。5.2.17本條規(guī)定了母線槽連接處、電纜頭和電纜外皮溫度檢查的周期,母線槽連接處測試溫度與前次測試結(jié)果比較應(yīng)無明顯變化,電纜頭和電纜外皮溫度應(yīng)符合現(xiàn)行電力行業(yè)標準《電力電纜線路運行規(guī)程》DL/T1253的相關(guān)規(guī)定。5.2.18雷雨季節(jié)前宜檢查浪涌保護器和開關(guān)確保功能正常,雷雨季節(jié)浪涌保護器和開關(guān)可能失效,宜定期檢查更換。5.2.19測量接地電阻是檢測防雷與接地裝置電氣連通性的一種方法,應(yīng)由具有專業(yè)資質(zhì)的機構(gòu)進行,并出具檢測報告。5.2.20接閃器包括接閃桿、接閃帶、接閃網(wǎng)等。5.3通風空調(diào)系統(tǒng)I冷源和水系統(tǒng)5.3.1潤滑油系統(tǒng)保養(yǎng)內(nèi)容:檢查油泵、密封和油泵電機及油系統(tǒng)其他部件,如油冷卻器、過濾器和電磁閥等。冷媒管路的維護包括:(1)檢查機組本體各傳感器插入孔、連接處、閥門處有無制冷劑泄漏或潤滑油泄漏現(xiàn)象;檢查制冷劑保有量是否充足,并根據(jù)運行情況進行制冷劑的充放。(2)檢查制冷劑泄漏報警裝置是否運行可靠,與報警裝置聯(lián)鎖的通風系統(tǒng)運轉(zhuǎn)是否正常。40《數(shù)據(jù)中心設(shè)施運行維護標準》條文說明傳感器的校準和更換:傳感器應(yīng)定期進行校準,且其工作時段應(yīng)在校準有效期內(nèi)。采用精度更高的儀器對相應(yīng)傳感器進行讀數(shù)校準,使實測值與校核值一致,無法校準的傳感器應(yīng)及時更換。同時還需檢查各接點是否牢固,探頭插接處是否密封良好。5.3.2水冷冷凝器和蒸發(fā)器需要根據(jù)端差來判斷是否需要進行內(nèi)部清洗,一般當排氣壓力對應(yīng)的飽和溫度與冷卻水出水溫度差值大于2.5~3℃時宜清洗冷凝器;當吸氣壓力對應(yīng)的飽和溫度與冷凍水出水溫度差值大于2.5~3℃時宜清洗蒸發(fā)器。數(shù)據(jù)中心空調(diào)系統(tǒng)常用的是板式換熱器,當根據(jù)運行溫差或壓差判斷板式換熱器臟堵程度嚴重時,需要拆開進行清洗,并根據(jù)板片表面附著物的種類確定清洗方法。使用時間較長的板片還應(yīng)采用透光和著色法進行檢測,以找出目測無法確定是否滲漏的板片。重新組裝后還應(yīng)進行水壓試驗確保能正常工作。II機房空調(diào)和風系統(tǒng)5.3.14功能性測試內(nèi)容包括機房氣密性測試、氣體滅火系統(tǒng)的聯(lián)動功能測試和高位泄壓閥性能測試。5.3.15機房空調(diào)的加濕器有多種形式,下面以常見的紅外加濕器、電極加濕器進行說明。紅外加濕器的維護要點為:檢查加濕水槽水位;檢查接水盤內(nèi)礦

溫馨提示

  • 1. 本站所有資源如無特殊說明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請下載最新的WinRAR軟件解壓。
  • 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請聯(lián)系上傳者。文件的所有權(quán)益歸上傳用戶所有。
  • 3. 本站RAR壓縮包中若帶圖紙,網(wǎng)頁內(nèi)容里面會有圖紙預(yù)覽,若沒有圖紙預(yù)覽就沒有圖紙。
  • 4. 未經(jīng)權(quán)益所有人同意不得將文件中的內(nèi)容挪作商業(yè)或盈利用途。
  • 5. 人人文庫網(wǎng)僅提供信息存儲空間,僅對用戶上傳內(nèi)容的表現(xiàn)方式做保護處理,對用戶上傳分享的文檔內(nèi)容本身不做任何修改或編輯,并不能對任何下載內(nèi)容負責。
  • 6. 下載文件中如有侵權(quán)或不適當內(nèi)容,請與我們聯(lián)系,我們立即糾正。
  • 7. 本站不保證下載資源的準確性、安全性和完整性, 同時也不承擔用戶因使用這些下載資源對自己和他人造成任何形式的傷害或損失。

評論

0/150

提交評論