版權說明:本文檔由用戶提供并上傳,收益歸屬內容提供方,若內容存在侵權,請進行舉報或認領
文檔簡介
目次
1總則································································································1
2術語································································································2
3基本規(guī)定························································································4
4設計································································································5
4.1一般規(guī)定·······························································································5
4.2一體化集成設計···················································································6
4.3裝配式隔墻和墻面···············································································6
4.4裝配式吊頂···························································································8
4.5裝配式樓地面·······················································································9
4.6集成廚房·······························································································9
4.7集成衛(wèi)生間·························································································11
4.8其他內裝部品·····················································································11
4.9設備管線·····························································································12
5生產供應······················································································14
5.1一般規(guī)定·····························································································14
5.2部品預案·····························································································15
5.3部品制造·····························································································16
5.4出廠檢驗·····························································································19
5.5包裝標識·····························································································19
6施工······························································································21
6.1一般規(guī)定·····························································································21
6.2施工準備·····························································································22
6.3施工要求·····························································································24
6.4成品保護·····························································································28
7工程質量驗收··············································································29
7.1一般規(guī)定·····························································································29
7.2內裝部品成品安裝驗收·····································································30
7.3裝配式隔墻及裝配式墻面·································································31
7.4裝配式吊頂·························································································33
7.5裝配式樓地面·····················································································34
7.6集成廚房·····························································································36
7.7集成衛(wèi)生間·························································································37
7.8設備管線·····························································································39
7.9工程質量驗收程序·············································································41
附錄A住宅室內裝配化裝修工程分項工程劃分························43
附錄B住宅室內裝配化裝修分戶工程質量驗收記錄················44
附錄C住宅室內裝配化裝修分組工程質量驗收匯總表············45
附錄D住宅室內裝配化裝修工程質量驗收匯總表····················46
本標準用詞說明················································································47
引用標準名錄····················································································48
附:條文說明····················································································49
1總則
1.0.1為規(guī)范河北省住宅室內裝配化裝修工程的實施,倡導綠色
施工、實現(xiàn)節(jié)能減排、提高建筑質量和品質、促進產業(yè)轉型升級,
制定本標準。
1.0.2本標準適用于河北省行政區(qū)域內新建、改建和擴建住宅室
內裝配化裝修的設計、施工、工程質量驗收和使用維護。
1.0.3住宅室內裝配化裝修工程應遵循建筑全生命期的可持續(xù)性
原則,并應堅持標準化設計、工廠化生產、裝配化施工、一體化
裝修、信息化管理、智能化應用的原則。
1.0.4住宅室內裝配化裝修工程除應符合本標準規(guī)定外,尚應符
合國家和河北省現(xiàn)行有關標準的規(guī)定。
1
2術語
2.0.1裝配化裝修assembleddecoration
采用干式工法,將工廠生產的標準化內裝部品在現(xiàn)場進行組
合安裝的工業(yè)化裝修建造方式。
2.0.2干式工法non-wetconstruction
采用干作業(yè)施工的建造方法。
2.0.3內裝部品interiordecorationpart
由工廠生產的建筑內裝單一產品或復合產品組裝而成的內裝
功能單元。
2.0.4管線分離pipe&wiredetachedfromstructuresystem
將設備與管線設置在結構系統(tǒng)之外的方式。
2.0.5架空層emptyfloor
地面基礎結構層與地面飾面層之間的間隔。
2.0.6裝配式隔墻、吊頂和樓地面assembledpartitionwall,
ceilingandfloor
由工廠生產的,具有隔聲、防火、防潮等性能,且滿足空間
功能和美學要求的部品集成,并主要采用干式工法裝配而成的隔
墻、吊頂和樓地面。
2.0.7裝配式墻面assembledwallsurface
在墻面基層上,主要采用干式工法,在工廠生產、在現(xiàn)場組
合安裝而成的集成化墻面,由連接構造和面層構成。
2.0.8集成廚房integratedkitchen
地面、吊頂、墻面、櫥柜、廚房設備及管線等通過設計集成、
工廠生產,在工地主要采用干式工法裝配而成的廚房。
2
2.0.9集成衛(wèi)生間integratedbathroom
地面、吊頂、墻面、潔具設備及管線等通過設計集成、工廠
生產,在工地主要采用干式工法裝配而成的衛(wèi)生間。
3
3基本規(guī)定
3.0.1新建住宅室內裝配化裝修工程應與建筑、結構、設備一體
化設計。
3.0.2住宅室內裝配化裝修工程應遵循管線分離的原則,保證使
用過程中維修、改造、更新的可能性和方便性。
3.0.3內裝部品應遵循標準化、模數(shù)化、通用化、集成化、可逆
性、可循環(huán)的的設計原則,滿足生產工業(yè)化、現(xiàn)場裝配化的要求,
以提高其通用性和互換性。內裝部品宜遵循方便拆裝的設計原則。
3.0.4原材料的品種、規(guī)格、質量應符合設計要求及國家和河北
省現(xiàn)行有關標準的規(guī)定,應選用綠色、節(jié)能及環(huán)保材料。
3.0.5住宅室內裝配化裝修工程驗收應滿足國家和河北省的相關
驗收管理規(guī)定。
3.0.6內裝部品、材料和施工的室內污染物限值應符合現(xiàn)行國家
標準《住宅設計規(guī)范》GB50096的相關規(guī)定。
3.0.7住宅室內裝配化裝修設計宜根據(jù)使用功能需要進行適老化
設計,并符合現(xiàn)行國家標準《老年人照料設施建筑設計標準》JGJ
450的相關規(guī)定。
4
4設計
4.1一般規(guī)定
4.1.1住宅室內裝配化裝修設計應符合防火、環(huán)保、節(jié)能、減排、
隔聲等有關規(guī)定,耐久性應滿足使用要求,且應符合《住宅室內
裝飾裝修設計規(guī)范》JGJ367的相關規(guī)定。
4.1.2住宅室內裝配化裝修設計應遵循模數(shù)化原則,應符合現(xiàn)行
國家標準《建筑模數(shù)協(xié)調標準》GB/T50002的相關規(guī)定。廚房、
衛(wèi)生間應符合《住宅廚房模數(shù)協(xié)調標準》JGJ/T262、《住宅衛(wèi)生
間模數(shù)協(xié)調標準》JGJ/T263的相關規(guī)定,廚房、衛(wèi)生間等功能空
間應以凈尺寸進行模數(shù)協(xié)調。
4.1.3住宅室內裝配化裝修設計宜遵循管線分離的原則,并符合
下列規(guī)定:
1設備管線、開關、插座宜敷設在裝配式隔墻、裝配式吊頂、
裝配式樓地面的空腔層或架空層內,并應考慮采取隔聲降噪、保
溫、防火、防結露、防霉變、接地等措施;
2輻射供暖應與裝配式隔墻、裝配式吊頂、裝配式樓地面一
體化設計。
4.1.4住宅室內裝配化裝修設計應明確內裝部品主要材料的性能
指標。內裝部品的選擇應符合防火、防水、防潮、隔聲、保溫、
抗震、綠色和環(huán)保等設計性能要求及國家和河北省有關標準的規(guī)
定。
4.1.5住宅室內裝配化裝修內裝部品宜選用可循環(huán)利用或可降解
的原材料制造的內裝部品;宜選用易更換、可替代性高的內裝部
品;宜選用工廠成套生產的集成衛(wèi)生間、集成廚房等集成度高的
5
內裝部品。
4.1.6住宅室內裝配化裝修內裝部品設計應滿足便于在使用過程
中的維護管理和檢修更換的要求。
4.1.7住宅室內裝配化裝修設計應符合《建筑內部裝修設計防火
規(guī)范》GB50222的相關要求,并應符合下列規(guī)定:
1架空層不應跨越有耐火性能要求的隔墻、樓板等部位;
2內裝部品設計不得采用降低其防火性能的構造做法;
3廚房裝配式墻面、吊頂及樓地面裝修材料應采用A級防
火材料。
4.1.8住宅室內裝配化裝修的施工圖設計應考慮生產加工、運輸
存儲和現(xiàn)場安裝的要求。
4.2一體化集成設計
4.2.1住宅室內裝配化裝修設計宜采用建筑信息模型(BIM)技
術,與建筑圍護系統(tǒng)、結構系統(tǒng)、設備與管線系統(tǒng)進行集成設計。
4.2.2住宅室內裝配化裝修設計宜與建筑智能化集成設計,并符
合《智能建筑設計標準》GB50314的相關規(guī)定。
4.2.3在戶型設計初期時,由室內設計和建筑設計配合并協(xié)同結
構、給排水、供暖、通風和空調、燃氣、電氣、智能化等各專業(yè)
的要求,進行同步協(xié)同設計,并統(tǒng)籌設計、生產、安裝和運維各
階段的需求。
4.3裝配式隔墻和墻面
4.3.1裝配式隔墻宜采用結構、設備管線、裝飾等協(xié)同設計,并
與門窗、樓地面、吊頂、家具和收納等協(xié)同設計。
6
4.3.2裝配式隔墻應與主體結構連接牢固。
4.3.3裝配式隔墻需要固定或吊掛物件時,應采取可靠的構造措
施,滿足墻體穩(wěn)定性的吊掛安全要求。
4.3.4裝配式隔墻宜采用一體化飾面。
4.3.5裝配式隔墻應采用有空腔的墻體,便于在墻體空腔內敷設
安裝給水分支管線、電氣分支管線及接線盒等。
4.3.6裝配式隔墻應滿足防火、隔聲、節(jié)能等性能要求。
4.3.7水、暖、電、燃氣、通風和空調等管線安裝及開洞處理穿
過裝配式隔墻時,孔洞周邊應采取密封、隔聲、保溫、防火等措
施,并應符合國家和河北省現(xiàn)行相關標準的規(guī)定。
4.3.8輕鋼龍骨隔墻設計應滿足下列規(guī)定:
1應根據(jù)隔聲性能、設備設施安裝需要等要求明確隔墻厚度,
同時應明確各種龍骨的規(guī)格型號;
2隔墻填充材料應滿足墻體防火、隔聲要求;
3有防水要求的房間隔墻,填充材料應具有較好的耐水性能;
其隔墻內側,應采取防水防潮措施,應重點對門洞口、隔墻根部
加強防水處理;
4隔墻上需要固定或吊掛重物時,應采用專用配件、加強背
板、在豎向龍骨上預設固定掛點或其他可靠的固定措施,并明確
固定點位;
5龍骨布置應滿足墻體強度的要求,隔墻高度超過3m時應
用斜支撐加強;
6門窗洞口、墻體轉角連接處等部位應加設龍骨進行加強處
理;
7飾面板與龍骨之間宜采用機械連接,非粘合膠類連接。
7
4.3.9輕質條板隔墻設計應滿足現(xiàn)行行業(yè)標準《建筑輕質條板隔
墻技術規(guī)程》JGJ/T157的相關要求,并符合以下規(guī)定:
1根據(jù)建筑設計要求,結合隔墻的性能和使用要求,應選用
能滿足安全、隔聲、防火要求的輕質條板隔墻;
2應根據(jù)建筑使用功能和條板隔墻的使用部位,選擇單層條
板隔墻或雙層條板隔墻;
3衛(wèi)生間等有防水要求的條板隔墻下端應做C20細石混凝
土條形墻基座,且墻基座高度距建筑完成面不應小于200mm,并
應作泛水處理;
4當條板隔墻需吊掛重物和設備時,不得單點固定,并應采
取加固措施,固定點間距應大于300mm。用作固定和加固的預埋
件和錨固件,均應作防腐或防銹處理。
4.3.10裝配式墻面的連接構造應與基層墻體結合牢固。
4.3.11裝配式墻面的飾面層應在工廠整體集成。
4.3.12裝配式墻面設計的分格尺寸和模塊組合應滿足裝修整體
效果,宜與原材料的規(guī)格尺寸協(xié)調,提高材料利用率,降低材料
消耗。
4.3.13裝配式墻面系統(tǒng)的標志尺寸宜符合模數(shù),其寬度、高度宜
符合模數(shù)要求。
4.4裝配式吊頂
4.4.1裝配式吊頂內宜設置可敷設管線的架空層。
4.4.2裝配式吊頂宜設集成燈具、排風扇等設備設施。
4.4.3裝配式吊頂應具備檢修條件。
4.4.4裝配式吊頂承載力應滿足相關規(guī)范及使用要求,連接構造
8
應穩(wěn)定、牢固。
4.5裝配式樓地面
4.5.1裝配式樓地面面層應采用平整、耐磨、抗污染、易清潔、
耐腐蝕的材料,廚房、衛(wèi)生間、陽臺等有防水要求的樓地面材料
還應具有防水、防滑等性能,施工工藝應具有防水、防滑、易運
維的性能。
4.5.2裝配式樓地面承載力應滿足使用要求,連接構造應穩(wěn)定、
牢固,放置重物的部位應采取加強措施。
4.5.3裝配式樓地面架空層高度應根據(jù)管線交叉情況進行計算,
并結合管線排布進行綜合設計。
4.5.4裝配式樓地面宜設置架空層檢修口。
4.5.5對采暖需求的空間,宜采用干式地板輻射供暖系統(tǒng),當采
用散熱器供暖時,供回水管宜選用干式工法實施;地面輻射供暖
宜與裝配式樓地面的連接構造集成。
4.5.6有防水要求的樓地面,應低于相鄰樓地面15mm,門檻及
門內外高差應以斜面過渡。
4.6集成廚房
4.6.1集成廚房設計應符合下列規(guī)定:
1集成廚房應與內裝設計進行統(tǒng)籌,與結構系統(tǒng)、外圍護
系統(tǒng)、公共設備與管線系統(tǒng)協(xié)同設計;
2應遵循人體工程學的要求,合理布局,并應進行標準化、
系列化和精細化設計;
9
3集成廚房宜滿足適老化的需求;
4集成廚房的設計應滿足易維護更新的要求;
5集成廚房空間尺寸應符合現(xiàn)行國家標準《住宅廚房及相
關設備基本參數(shù)》GB/T11228、行業(yè)標準《工業(yè)化住宅尺寸協(xié)調
標準》JGJ/T445的規(guī)定。
4.6.2廚房布置形式可采用單排型、雙排型、L型、U型和壁柜
型,廚房的凈尺寸應符合標準化設計和模數(shù)協(xié)調的要求。
4.6.3廚房的洗滌盆、灶具、排油煙機、電器設備、櫥柜、吊柜
等設施應一次性集成設計到位。
4.6.4廚房家具、櫥柜應與墻體可靠連接固定,與輕質隔墻體連
接時應采取加強構造措施。
4.6.5廚房墻面、地面應選用易清潔材料,地面應防滑,集成櫥
柜宜采用防火、耐水、耐磨、耐腐蝕、易清潔的材料。
4.6.6集成廚房的墻面、地面、櫥柜與內裝系統(tǒng)裝飾風格統(tǒng)一,
應重點設計收口構造節(jié)點。
4.6.7集成廚房管線應進行綜合設計,除燃氣管線外,其他管線
宜設在廚柜背部或吊頂內。住宅廚房內的冷熱水表、燃氣表、凈
水設備等宜集中布置,且便于查抄和檢修。
4.6.8集成廚房櫥柜及設備應集成設計,空間布置、管線敷設應
符合使用功能要求,櫥柜尺寸應符合人體工學。
4.6.9櫥柜宜與裝配式墻面集成設計。
4.6.10集成廚房的各類水、電、暖等設備管線應設置在架空層內,
并設置檢修口。
4.6.11戶內燃氣立管應設置在有自然通風的廚房或與廚房相連
的陽臺內,且宜明裝設置,不得設置在通風排氣豎井內。
10
4.6.12燃氣設備的設置應滿足《城鎮(zhèn)燃氣設計規(guī)范》GB50028
及《住宅設計規(guī)范》GB50096的要求。
4.7集成衛(wèi)生間
4.7.1集成衛(wèi)生間設計應根據(jù)模數(shù)協(xié)調及標準化設計合理安排如
廁區(qū)、洗漱區(qū)、淋浴區(qū)的位置,且宜采用干濕區(qū)分離的設計。
4.7.2集成衛(wèi)生間使用功能應符合國家和河北省現(xiàn)行相關標準的
規(guī)定,洗手臺、鏡子、潔具、龍頭、衛(wèi)浴五金配件等宜采用標準
化產品,且布置應符合人體工學。
4.7.3集成衛(wèi)生間應采用可靠的防水設計,樓地面宜采用整體防
水底盤,門口處應設有阻止積水外溢的措施。
4.7.4集成衛(wèi)生間的各類水、電、暖等設備管線應設置在架空層
內,并設置檢修口。
4.7.5集成衛(wèi)生間宜采用同層排水。
4.7.6采用同層排水方式時,應按所采用集成式衛(wèi)生間的管道連
接要求確定降板區(qū)域和降板深度,并應有可靠的管道防滲漏措施;
當采用異層排水方式時,排水支管、地漏等穿越樓板孔洞定位應
準確。同層排水架空地板的衛(wèi)生間宜采用散熱器采暖。
4.7.7設有洗浴設備的集成衛(wèi)生間應設置輔助保護等電位聯(lián)結。
4.8其他內裝部品
4.8.1整體收納設計應符合下列要求:
1應考慮基本功能空間布局及面積、使用人員需求、物品種
類及數(shù)量等因素進行設計;
11
2應采用標準化內裝部品;
3整體收納所用板材和五金件材料性能應符合國家和河北
省現(xiàn)行相關標準的規(guī)定。
4.8.2內門窗宜選用成套的內裝部品,設計文件應明確所采用門
窗的材料品種、規(guī)格等指標。
4.8.3窗簾盒(桿)、窗臺板、頂角線、踢腳線、陽角線、檢修口、
戶內樓梯、護欄、扶手、花飾等部品應與室內裝配化裝修集成設
計。
4.8.4內裝部品宜選用滿足干式工法的成套化產品。
4.9設備管線
4.9.1集中管道井應設置在公共區(qū)域,并應設置檢修門,尺寸應
滿足管道檢修更換的空間要求。
4.9.2設備管線應選用耐腐蝕、使用壽命長、降噪性能好、便于
安裝及維修的管材、管件,以及連接可靠、密封性能好的管道閥
門設備。
4.9.3給水管線設計應滿足下列規(guī)定:
1生活給水系統(tǒng)所用管材、管件應達到飲用水衛(wèi)生標準;
2敷設在架空層、夾層內的給水、熱水管道宜采用相應的保
溫、防結露措施;
3敷設在架空層、夾層內的冷水、熱水、中水等支管、分支
管應采用不同顏色或標識進行區(qū)分。
4.9.4排水管線設計應滿足下列規(guī)定:
1排水管道管件應采用45°轉角管件;
2在衛(wèi)生間以外的洗衣機區(qū)域宜設置防水底盤,并采用配套
12
排水接口。
4.9.5供暖設備及管線設計應滿足下列規(guī)定:
1宜采用干式工法工藝的地面輻射供暖方式;地面輻射供暖
宜與裝配式樓地面集中設計。分集水器宜與內裝部品集成設計;
2當室內采用散熱器供暖時,供回水管宜選用干法施工,散
熱器的安裝位置應能使室內溫度均勻分布。
4.9.6通風設計應滿足下列規(guī)定:
1廚房和無外窗衛(wèi)生間應有通風設施,無外窗的暗衛(wèi)生間應
設置防止回流的機械通風設施;
2豎向煙風道應采用能夠防止各層回流的標準化產品。
4.9.7電氣設備及管線設計應滿足下列規(guī)定:
1電氣線路應采用符合安全和防火要求的敷設方式配線,導
線應采用銅芯絕緣線,導線接頭宜采用快插式接頭;
2電氣管線宜敷設在架空層內,電氣面板、接線盒、戶配電
箱及家居配線箱等應與內裝部品集成設計;
3強、弱電線路敷設時不應與燃氣管線交叉設置;當與給排
水管線交叉設置時,應滿足電氣管線在上的原則。
13
5生產供應
5.1一般規(guī)定
5.1.1裝配化裝修部品應根據(jù)設計總體要求,進行系統(tǒng)化設計,
在符合工業(yè)化生產流程基礎上,提高部品的集成化、模塊化、標
準化程度,提高施工安裝和使用維護的便利性。
5.1.2為確保裝配化裝修部品的裝配品質與精準供應,應從部品
預案、部品制造、出廠檢驗、包裝標識、儲運堆放等方面進行控
制。
5.1.3裝配化裝修部品可分為系統(tǒng)級、部件級、材料級,并應符
合下列要求:
1系統(tǒng)級部品應提高其體系的開放性和通用性,通過多個子
體系的互換性實現(xiàn)多樣化;
2部件級部品應提高其產品的通用性和系列化、成套化,通
過模數(shù)化的尺寸控制實現(xiàn)廣泛的互換性;
3材料級部品原材料應綠色環(huán)保,提高其產品的標準化和集
成化,減少現(xiàn)場作業(yè)。
5.1.4裝配化裝修部品制造企業(yè)應建立或遵循產品相關標準,系
統(tǒng)級部品制造企業(yè)應建立企業(yè)標準,并在屬地的技術質量監(jiān)督部
門備案、公示。
5.1.5裝配化裝修部品制造企業(yè)生產設施和設備等應符合部品生
產質量保證要求,并進行必要的原材料、半成品和成品試驗檢驗。
5.1.6裝配化裝修部品制造企業(yè)應建立完整的技術標準體系,以
及質量、職業(yè)健康安全與環(huán)境管理體系。
14
5.1.7裝配化裝修部品制造企業(yè)應對其出品進行標識,并應對檢
驗合格的部品出具合格證明文件,標識系統(tǒng)應滿足溯源性要求,
訂制部品還應具有標識唯一性。
5.1.8部品成品和半成品的制造、儲運、成品保護和質量檢驗除
應符合本標準外,還應符合相應行業(yè)產品標準及國家和河北省現(xiàn)
行相關標準的規(guī)定。
5.2部品預案
5.2.1部品預案應符合下列要求:
1應控制標準參數(shù)部品與非標部品的系列規(guī)格組合,實現(xiàn)大
小批量同步均衡轉換,柔性制造,同步配套;
2應明確部品之間連接的標準接口類型、規(guī)格、接駁方式,
應明確配套的部件、配件及零件構成;
3應考慮上下道裝修工序的影響,減少干擾;
4宜對所有定制部品進行唯一編碼。
5.2.2系統(tǒng)級部品制造企業(yè)應對其產品體系進行公示。包括其適
用范圍、構成方式、主要指標、遵從標準、拼裝模數(shù)以及產品特
色等。
5.2.3部品制造企業(yè)在產品公示中,宜闡述自身產品與周邊配套
部品的關聯(lián)關系,包括尺寸配合、連接方式、拆裝順序及配合限
制。
5.2.4除材料外的成品部品尺寸應遵循通用性原則,尺寸標注應
符合下列要求:
1部品的外廓或邊界尺寸應標注最大尺寸,制造過程中的公
差帶應控制在標注尺寸以內;
15
2部品的內腔或容納尺寸應標注最小尺寸,制造過程中的公
差帶應控制在標注尺寸之外。
5.2.5定制部品生產加工前,應根據(jù)工程要求及現(xiàn)場勘驗結果,
制定生產或組合預案,并符合下列條件:
1應優(yōu)先選用標準參數(shù)部品,非標部品應適度歸尺并預留配
合公差;
2宜聲明與周邊配套部品的關聯(lián)要求,尤其是拆裝要求,以
及因定制而造成變化的飾面要求、配套方式、接口調整等。
5.2.6對于在工廠內完成主要裝配的大型部品,應明確運輸、存
放、就位的相關條件和要求。
5.3部品制造
5.3.1部品生產制造中,宜將信息技術應用到生產環(huán)節(jié),連接設
計和施工信息,實現(xiàn)智能化制造。
5.3.2部品生產所用原材料應符合國家和河北省現(xiàn)行有關產品標
準的規(guī)定,具有質量合格證明文件并按相關規(guī)定進行抽樣檢測,
未經檢驗或檢驗不合格,不得使用。
5.3.3部品制造各工序應按生產工藝要求進行質量控制,實行工
序檢驗與可追溯生產日志。
5.3.4部件連接構造應采用安全、可靠、耐久的工業(yè)化集成技術,
確保結構連接可靠,裝配方式應具有可拆卸性,飾面材料應易于
面層的翻新或改造。
5.3.5部品應根據(jù)設計技術要求在工廠內完成加工,如需要在現(xiàn)
場安裝中補充加工,應結合切口是否需要處理而配備相應的工具
及輔料,并在產品說明書或作業(yè)指導書中明確操作規(guī)程。
16
5.3.6根據(jù)設計明確劃定裝配責任,部品所需專用配件或輔料應
為部品的組成部分。
5.3.7對于非常年生產的部品部件,宜適量預留部品或配件的數(shù)
量,以備安裝損耗以及維護所需。
5.3.8應對部品的產品編碼和生產日志存檔,進行質量跟蹤和追
溯。
5.3.9輕鋼龍骨隔墻部品生產加工應符合下列要求:
1裝配式隔墻龍骨應在工廠定尺加工;
2隔墻龍骨使用鍍鋅材料的,應在工廠內采用機械式擠壓斷
切,嚴禁電動工具鋸裁。
5.3.10型鋼架空模塊部品生產加工應符合下列要求:
1架空地面有高度調節(jié)裝置,可以根據(jù)套內與公區(qū)需要靈活
調整架空層敷設管線的高度;
2架空地面可快速拆裝。
5.3.11壁紙類材質墻面飾面層生產加工應符合下列要求:
1如采用在工廠將找平層與飾面層集成的,墻面飾面層應覆
蓋到找平層側面包邊,避免飾面翹起、開裂、脫落;
2如采用在工廠完成裁剪包裝后的規(guī)格壁紙,應在工地現(xiàn)場
設置的加工區(qū)域對壁紙加工制成部品,再包裝搬運到施工現(xiàn)場。
5.3.12集成式衛(wèi)生間部品生產加工應符合下列要求:
1樓地面、墻面(板)、吊頂應采用防水、耐磨、防腐蝕材
料;
2墻板接縫應采用止水構造,帶面磚飾面的壁板宜采用反打
一次成型工藝制作;
3防水地面盤應確保不漏水,并有沿墻立體反沿,轉彎處為
17
弧形以避免形成衛(wèi)生死角。
5.3.13整體衛(wèi)生間部品生產加工應符合下列要求:
1防水底盤、壁板、頂板應采用防水、耐磨、防腐蝕材料;
2檢修口、墻面孔洞應采用設計預留方式在工廠內完成加工,
應套割吻合、邊緣整齊;
3防水底盤應一次性擠壓成型;
5.3.14集成廚房部品生產加工應符合下列規(guī)定:
1集成式廚房加工安裝吊柜、電器的加固板;
2廚房墻面面層部品進行防水、防火、防潮、防霉、耐高溫、
耐腐蝕及抗吸污、耐擦洗等工藝處理;
3廚房吊頂宜與通風、排煙、照明等設備設施集成生產。
5.3.15管材類部品生產加工應符合下列規(guī)定:
1管路中的管材和管件產品宜根據(jù)現(xiàn)場勘查結果,采用工廠
預制化方式,通過復合產品組裝減少現(xiàn)場切割和現(xiàn)場連接點;
2管路中的關鍵部品如分水器、閥門、以及與衛(wèi)浴的連接部
件應采用標準化產品,應具有可靠性、通用性和互換性;
3冷熱水管線、強弱電管線宜在生產時做好標識線或顏色區(qū)
分,便于維護和更換。以盤管形式供貨的產品,宜在管材上做好
標記,方便現(xiàn)場量取和安裝;
4部品生產制造時,宜采用國內成熟可靠的快裝技術進行部
品連接設計;
5給水、排水部品中含有密封圈作為密封的,密封圈材質不
得含有再生膠,應符合相關標準要求。
5.3.16同層排水部品生產加工應符合下列規(guī)定:
1同層排水地漏與整體防水地面配套加工,確保連接處安
18
裝緊密,并做閉水試驗;
2排水管加工快裝承插技術接口。
5.3.17干敷地暖部品生產加工應符合下列規(guī)定:
1地面輻射供暖部品宜于架空的地面集成制造,形成標準化、
模塊化及系列化的集成產品;
2設備接口全部制造加工快裝承插技術接口;
3分支路采暖管線整體加工不得有接頭。
5.4出廠檢驗
5.4.1部品出廠檢驗應符合現(xiàn)行標準要求,應明確質量保證期限。
5.4.2裝配式內裝修部品生產企業(yè)應按照有關標準規(guī)定或合同要
求,對出廠部品進行質量檢驗,對合格產品簽發(fā)產品合格證,合
格證應標注產品相關信息。
5.5包裝標識
5.5.1部品包裝時應同批次內置包裝部品明細清單、產品說明書、
作業(yè)指導書及產品合格證等。
5.5.2部品的配套部件應齊全并同批次交付,易損易耗零配件宜
適量增配,需要專用工具進行裝配時,應與部品同批次配備相應
數(shù)量工具。
5.5.3部品包裝材料宜采用環(huán)保、可回收循環(huán)使用的材料,宜采
用可用于現(xiàn)場安裝過程保護的包裝物。
5.5.4部品及包裝物上的標識,應詳細描述部品的特性、適用部
位及配置信息,并符合下列要求:
19
1通用標準部品部件(如連接件、龍骨、收口條等)應標識
規(guī)格和樣式;
2飾面部品部件(如磁磚、壁紙、燈具等)應增加批號和出
品日期;
3訂制部品部件(如門窗、家具等)則應具備唯一性,并采
用醒目的、易于區(qū)分應用區(qū)域的標識方式;
4對具有特定使用條件或期限的輔料或配件,應專門標識;
包裝方式應能保證一般運輸條件下對部品的保護,防止運輸和搬
運時部件受到擠壓沖擊、受潮、變形、損壞部件表面及邊角,并
應防止流體或細碎物品流失。
5.5.5部品包裝便于叉車等裝卸工具抓放和工人搬運,包裝箱尺
寸規(guī)格滿足運輸條件規(guī)定。
5.5.6面板包裝應符合下列要求:
1面板裝箱必須保持平放,面板與面板之間應做保護;
2面板放置完畢,在箱內用打包帶固定不少于三道(打包帶
與面板接觸處,加墊L型紙護角),完成后封箱。
5.5.7成品門包裝應符合下列要求:
1門內四周必須要有護角保護;門四周棱角處,用內墊、氣
泡膜包護;
2外包裝Logo粘貼位置宜統(tǒng)一;
3外包裝標簽必須與產品實物相符且填寫正確規(guī)范;
4外包裝用不少于5層紙板或紙箱包裝,紙板與紙箱無破損
現(xiàn)象。
5.5.8玻璃包裝應在每片玻璃上需注明工程名稱、尺寸、墻號、
樓層及區(qū)域(按甲方下單提供的內容做標簽明細)。
20
6施工
6.1一般規(guī)定
6.1.1住宅室內裝配化裝修工程宜采用穿插施工。
6.1.2住宅室內裝配化裝修施工安裝應協(xié)同主體結構系統(tǒng)、外圍
護系統(tǒng)、設備與管線系統(tǒng),根據(jù)建筑主體工程特點制定單位工程
施工組織設計及施工方案,且應遵守設計、生產、裝配一體化的
原則進行整體策劃,明確各分項工程的施工界面、施工順序與避
讓原則,總承包單位應對裝配化內裝修施工進行精細化管理及動
態(tài)管理。
6.1.3施工單位應按照設計文件編制專項施工技術方案,并對施
工全過程實行質量控制。
6.1.4內裝部品運輸、存儲及安裝過程中,應采取保護措施。
6.1.5改擴建住宅工程室內實施裝配化裝修,應避免對主體結構
的破壞。
6.1.6住宅室內裝配化裝修施工宜采用標準化工藝和工具化裝備。
裝配化內裝修施工中采用的新技術、新工藝、新材料、新設備、
新的或首次采用的施工工藝,應確保在符合國家和河北省現(xiàn)行有
關標準、規(guī)范的規(guī)定后再實施。
6.1.7住宅室內裝配化裝修施工宜采用信息化模型技術對施工全
過程進行協(xié)調管理。
6.1.8住宅室內裝配化裝修施工應遵守國家施工安全、環(huán)境保護
的標準,制定安全與環(huán)境保護專項方案。宜采用綠色施工模式,
減少現(xiàn)場切割作業(yè)和建筑垃圾。
21
6.1.9住宅室內裝配化裝修施工應符合國家和河北省現(xiàn)行有關標
準、規(guī)范的規(guī)定。室內裝配化裝修工程宜達到現(xiàn)場少噪音、少污
染、少垃圾的綠色施工要求。
6.1.10裝配化內裝修施工應滿足可逆安裝、易維護的要求。
6.1.11裝配化內裝修施工前,應選擇有代表性的空間單元和主要
部品進行樣板間或樣板試安裝,并應根據(jù)試安裝結果及時調整施
工工藝、完善施工方案,且應經各方確認。
6.1.12施工單位應根據(jù)項目裝配化內裝修工程特點和規(guī)模設置
組織架構、配備管理人員和選擇專業(yè)施工隊伍,施工作業(yè)人員應
具備崗位所需的基礎知識和技能。
6.2施工準備
6.2.1裝配化內裝修施工前,應及時與總承包單位溝通協(xié)調,總
承包單位應按合同約定或協(xié)商結果提供內裝修施工所需的部品部
件運輸通道、堆放場地、垂直運輸、供水供電、施工作業(yè)面等必
要的施工條件。
6.2.2裝配化內裝修施工前,應進行設計交底工作,編制專項施
工方案。
6.2.3裝配化內裝修各分項工程安裝施工前,根據(jù)工程需要應核
對已施工完成的建筑主體的外觀質量和尺寸偏差,確認預留預埋
符合設計文件要求,確認隱蔽工程已完成驗收工作,復核相關的
成品保護情況,確認具有施工條件,完成施工交接手續(xù)。
6.2.4裝配化內裝修各分項工程安裝施工前,應根據(jù)設計文件的
要求完成測量放線,通過測量歸尺與公差配合,保持部品部件凈
尺寸一致,并設置部品部件安裝定位標識。
22
6.2.5裝配化內裝修施工前,應準備施工所需的設備、部品部件
的需求計劃、貨源組織安排,并明確部品部件的編碼類型及編碼
信息。
6.2.6內裝部品部件進場時間應遵循施工組織設計及專項施工方
案的規(guī)定,且應進行進場檢驗,其品種、規(guī)格、性能和外觀應符
合設計要求及國家和河北省現(xiàn)行有關標準的規(guī)定,并應形成相應
的驗收記錄。
6.2.7裝配化內裝修進場部品存放時,應按安裝位置及安裝順序
分類存放,存放區(qū)域宜實行分區(qū)管理和信息化臺賬管理。
6.2.8裝配化內裝修進場部品的靠(插)放架或托盤應具有足夠
的承載力和剛度,并應采取保持支架穩(wěn)固的措施。
6.2.9裝配式隔墻及裝配式墻面應滿足下列規(guī)定:
1裝配式隔墻及墻面部品應符合圖紙設計要求,按照所使用
的部位做好分類選配;
2隔墻及墻面安裝前應按圖紙設計做好定位控制線、標高線、
細部節(jié)點線等,應放線清晰,位置準確,且通過驗收;
3裝配式隔墻安裝前應檢查結構預留管線接口的準確性;
4裝配式隔墻空腔內填充材料性能和填充密實度等指標應
符合設計要求;
5裝配式隔墻及墻面施工前應做好交接檢查記錄;
6條板隔墻安裝構造圖及相關技術資料,應包括條板與條板
間的連接構造;條板隔墻與梁板、頂板、地面、防潮墊層的連接
做法;條板隔墻與主體墻、柱的連接做法;條板隔墻門、窗洞口
處的構造做法;鋼板卡件、預埋件做法;條板隔墻內暗埋管線及
吊掛重物的加固構造和修補加強措施等。
23
6.2.10裝配式吊頂應滿足下列規(guī)定:
1應確定吊頂板上燈具、風口等部品的位置,按部品安裝尺
寸開孔;
2裝配式吊頂安裝前,墻面應完成并通過驗收;
3應完成吊頂內管線安裝等隱蔽驗收;
4龍骨、吊頂板安裝應符合現(xiàn)行國家和河北省的相關規(guī)定。
6.2.11裝配式樓地面應滿足下列規(guī)定:
1應按設計圖紙放地面控制線,位置準確;
2應完成架空層內管線安裝等隱蔽驗收;
3裝配式樓地面安裝前,應對基層進行清潔、干燥并吸塵。
6.2.12集成衛(wèi)生間應滿足下列規(guī)定:
1應完成基層、預留孔洞、預留管線等隱蔽驗收;
2設計有樓面結構層防水時,應完成防水施工并隱蔽驗收合
格。
6.2.13集成廚房應滿足下列規(guī)定:
1應完成基層、預留孔洞、預留管線等隱蔽驗收;
2集成廚房櫥柜應與墻體可靠連接,集成廚房墻面應按懸掛
式櫥柜及設備的受力點,設置符合荷載規(guī)定的構造措施。櫥柜、
電器設備設計有加固要求時,加固措施應與結構連接牢固。
6.2.14設備管線應滿足下列規(guī)定:
1按設計圖紙定位放線,放線應清晰,位置應準確;
2應完成預留孔洞、預留管線等隱蔽驗收。
6.3施工要求
6.3.1裝配式隔墻及裝配式墻面施工應滿足下列規(guī)定:
24
1輕鋼龍骨隔墻施工要求:
1)應滿足輕鋼龍骨隔墻的設計及施工的國家和河北
省的相關規(guī)范和標準等;
2)裝配式隔墻內水電管路鋪設完畢且經隱蔽驗收合
格后方可進行墻體填充,隔墻內填充材料應密實無
縫隙,減少現(xiàn)場切割;
3)墻面施工前應按照設計圖紙對需掛重物的部位進行
加固。
2輕質條板隔墻施工要求:
1)應按排板圖在地面及頂棚板面上放線,條板應從主
體墻、柱的一端向另一端按順序安裝;當有門洞口
時,宜從門洞口向兩側安裝,門窗洞口處,應有加
強措施;
2)板與板之間的對接縫隙內應填滿、灌實粘結材料,
板縫間隙應揉擠嚴密,被擠出的粘結材料應刮平勾
實;
3)安裝時,應清除板頂端及兩側浮灰,并滿刮粘接劑;
4)除應符合本標準的規(guī)定外,尚應符合《建筑輕質條
板隔墻技術規(guī)程》JGJ/T157及其他國家和河北省現(xiàn)
行有關標準的規(guī)定。
3裝配式墻面施工要求:
1)裝配式墻面應按設計連接方式與隔墻(基層)連接
牢固;
2)設計有防水要求的裝配式墻面時,穿透防水層的部
位應采取加強措施;
25
3)裝配式墻面與門套、窗套、配電箱、家居配線箱及
電氣面板等交接處應封閉嚴密;
4)裝配式墻面上的開關面板、插座面板等后開洞部位,
位置應準確,不應安裝后二次開洞;
5)裝配式墻面施工完成后,應對特殊加強部位的功能
性進行標識。
6.3.2裝配式吊頂施工應滿足下列規(guī)定:
1安裝時應采取防止擠壓沖擊、受潮、變形及損壞板材的表
面和邊角的措施;
2吊桿、龍骨及配件、飾面板及吊頂內填充的吸音、保溫、
防火等材料的品種、規(guī)格及安裝方式應符合設計要求;
3預埋件、金屬吊桿、自攻螺釘?shù)葢M行防銹處理;
4除應符合本標準的規(guī)定外,尚應符合國家和河北省現(xiàn)行有
關標準的規(guī)定。
6.3.3裝配式樓地面施工應滿足下列規(guī)定:
1按設計圖紙布置可調節(jié)支撐構造,并進行調平;
2飾面層鋪裝應根據(jù)圖紙排板尺寸放十字鋪裝控制線,相鄰
地板宜采用企口連接;
3飾面層鋪裝完,安裝踢腳線壓住板縫。
6.3.4集成衛(wèi)生間施工應滿足下列規(guī)定:
1當墻面采用聚乙烯薄膜作為防水層時,墻面應做至頂部,
在衛(wèi)生間內形成圍合,在門口處向外延伸不應小于100mm;
2當安裝衛(wèi)生器具、衛(wèi)浴配件、電氣面板等部品時,應采取
防水層保護措施;
3當?shù)孛娌捎谜w防水底盤時,地漏應與整體防水底盤安裝
26
緊密,并做閉水試驗。
6.3.5集成廚房施工應滿足下列規(guī)定:
1櫥柜柜體與墻面應連接牢固;
2采用油煙水平直排系統(tǒng)時,風帽應安裝牢固,與結構墻體
之間的縫隙應密封。
6.3.6給水管線施工應滿足下列規(guī)定:
1生活給水系統(tǒng)所用管材、管件應達到飲用水衛(wèi)生標準;
2給水管道施工所使用的管材、管件宜為同一品牌產品;
3在架空層、夾層內敷設的給水管道應設置支(托)架,并
與結構體可靠連接;
4給水管道連接完成后,應按要求進行管道消毒及水壓試驗。
6.3.7排水管線施工應滿足下列規(guī)定:
1架空層內排水管道支(托)架及管座的安裝應按排水坡度
排列整齊,支(托)架與管道接觸緊密,非金屬排水管道采用金
屬支架時,應在與管外徑接觸處設置橡膠墊片;
2架空地板施工前,架空層內排水管道應進行灌水試驗。
6.3.8供暖設備及管線施工應滿足下列規(guī)定:
1設置在裝配式樓地面架空層內的管道不應有接頭,管道穿
過裝配式樓地面處應設置保護套管;
2分集水器安裝位置應準確,管道與分集水器應連接緊密。
6.3.9電氣設備及管線施工應滿足下列規(guī)定:
1線纜在吊頂、裝配式樓地面及裝配式隔墻或墻體的架空層
內敷設時,應穿管或采用槽盒保護,敷設在線管(槽盒)內的線
纜中間不應有接頭;
2電氣設備與管線施工完成后,應對系統(tǒng)進行試驗和調試,
27
暗敷在架空層或空腔內的管線應在驗收合格并形成文件記錄后方
可隱蔽。
6.4成品保護
6.4.1從工廠到施工現(xiàn)場的部品運輸時,應提前制定運輸計劃及
方案,超高、超寬、形狀特殊的大型部品的運輸和碼放應采取質
量安全保證措施。
6.4.2施工現(xiàn)場二次搬運、分料到位時,應提前查勘場地條件并
進行處理,確保卸載工具及轉運工具順利通行,部品宜由機械化
工具運輸上樓,減少人工消耗。
6.4.3部品存放場地應平整堅實,并按部品的保管技術要求采取
相應的防雨、防潮、防曝曬、防污染、防相互磨擦等措施。
6.4.4部品堆放應按照材料種類、安裝順序、安裝位置分類堆放,
堆放方式應依部品材料的結構特性分為平放、立放、斜放等方式,
以避免部品材料變形或磨損。
6.4.5成品保護除應符合本標準的規(guī)定外,尚應符合《建筑裝飾
裝修工程成品保護技術標準》JGJ/T427及其他國家和河北省現(xiàn)行
有關標準的規(guī)定。
28
7工程質量驗收
7.1一般規(guī)定
7.1.1住宅室內裝配化裝修工程質量除應執(zhí)行本標準外,尚應符
合現(xiàn)行國家及河北省地方標準等的有關規(guī)定。
7.1.2住宅室內裝配化裝修內裝部品的品種、規(guī)格、性能應符合
設計要求。
7.1.3內裝部品成品安裝驗收時,如不能提供內裝部品成品合格
文件,應對不同分項單獨驗收。
7.1.4住宅室內裝配化裝修工程隱蔽驗收應在作業(yè)面封閉前進行,
并按現(xiàn)行國家標準《建筑裝飾裝修工程質量驗收標準》GB50210
形成驗收記錄。
7.1.5住宅室內裝配化裝修工程質量驗收按下列規(guī)定劃分檢驗單
元。
1以1個單元或樓層作為子分部工程的檢驗單元;
2墻體、頂棚、地面等作為組成子分部的分項;
3通風與空調、建筑電氣、智能建筑等獨立系統(tǒng)作為子分部
工程,系統(tǒng)下相應安裝工序作為分項;
4住宅室內裝配化裝修工程分項工程劃分參見附錄A;
5戶箱以下的強電、弱電管線及設備,水表以后的給水管線
及設備,主立管之前的排水管道及設備,宜作為裝配式裝修的子
分部進行驗收。
7.1.6住宅室內裝配化裝修工程驗收應以戶(套)為單位進行分
戶工程驗收。
29
7.1.7住宅室內裝配化裝修工程所用材料、部品的質量、燃燒性
能以及有害物質限量,應符合設計要求及國家、行業(yè)、河北省現(xiàn)
行相關標準的規(guī)定。裝配化裝修工程的室內環(huán)境質量應符合現(xiàn)行
國家標準《民用建筑工程室內環(huán)境污染控制標準》GB50325的規(guī)
定。
7.1.8當裝配化裝修工程中首次使用新技術、新工藝、新材料和
新設備且專業(yè)驗收標準未作出相應規(guī)定時,建設單位應組織監(jiān)理、
設計、施工等相關單位制定專項驗收要求。涉及安全、節(jié)能、環(huán)
境保護等項目的專項驗收要求,應由建設單位組織專家論證。
7.1.9住宅室內裝配化裝修工程驗收時,施工單位宜提供使用說
明書。
7.1.10內裝部品成品進場時應提供成品合格證。內裝部品成品、
裝配式隔墻及墻面、裝配式吊頂部品、裝配式樓地面部品、集成
衛(wèi)生間部品、集成廚房部品均應按照部品的設計參數(shù)及相關標準
要求每500戶進行一組復試。
7.1.11為實現(xiàn)信息化管理,推進全流程建筑信息模型(BIM)使
用,裝配式內裝修工程驗收文件宜采用BIM數(shù)據(jù)和相應的電子化
文件。
7.1.12裝配式內裝修工程驗收時應提供安全與環(huán)保專項方案以
及相應的實施報告。
7.2內裝部品成品安裝驗收
7.2.1內裝部品成品安裝驗收前應完成下列隱蔽項目的現(xiàn)場驗收:
1內裝部品成品與主體結構或內裝部品成品之間的連接;連
接件的規(guī)格、數(shù)量、位置等進行相應檢驗;
30
2內裝部品成品管線與預留管線的接口連接;
3當設計有防水要求時應對防水層進行檢驗。
Ⅰ主控項目
7.2.2內裝部品成品安裝驗收時,內裝部品成品與主體結構或內
裝部品成品之間的連接應符合設計要求。
Ⅱ一般項目
7.2.3內裝部品成品安裝驗收的允許偏差和檢驗方法應符合
表7.2.3的規(guī)定:
表7.2.3內裝部品成品安裝驗收的允許偏差和檢驗方法
項次項目允許偏差(mm)檢驗方法
1表面平整度3用2m靠尺和塞尺檢查,各平面四角處
2立面垂直度3用2m托線板(垂直檢測尺)
3陰陽角方正3用方尺和塞尺檢查
4接縫直線度2拉5m線,不足5m拉通線,用鋼直尺檢查
用鋼直尺和塞尺檢查,同一平面檢查不少
5接縫高低差1
于3處
7.3裝配式隔墻及裝配式墻面
7.3.1裝配式隔墻及墻面工程應對下列隱蔽工程項目進行驗收:
1龍骨安裝;
2填充材料設置;
31
3預埋件;
4連接構造安裝;
5隔墻中設備管線的安裝及水管試壓。
Ⅰ主控項目
7.3.2隔墻安裝位置正確,連接牢固無松動,與周邊墻體的連接
符合設計要求。
檢驗方法:尺量檢查、查看隱蔽工程驗收記錄。
7.3.3飾面板安裝應牢固、無脫層、翹曲、折裂、缺棱、掉角。
飾面板采用的接縫方法及接縫材料應符合設計要求。
檢驗方法:目測檢查、手扳檢查、查看檢測報告。
7.3.4裝配式隔墻和墻面所用材料的品種、規(guī)格、色號、性能和
燃燒等級、有害物質限量等應符合設計要求和現(xiàn)行國家、行業(yè)、
地方標準的規(guī)定。
檢驗方法:觀察、檢查產品合格證書、進場驗收記錄和性能
檢測報告。
Ⅱ一般項目
7.3.5隔墻墻面應平整、潔凈、拼縫平直。套裁電氣盒蓋位置準
確,接縫整齊。
檢驗方法:目測檢查,尺量檢查。
7.3.6裝配式隔墻及墻面工程的允許偏差和檢驗方法應符合
表7.3.6的規(guī)定。
32
表7.3.6裝配式隔墻及墻面工程的允許偏差和檢驗方法
項次項目允許偏差(mm)檢驗方法
1立面垂直度3用2m托線板(垂直檢測尺)
2表面平整度3用2m靠尺和塞尺檢查
3陰陽角方正3用方尺和塞尺檢查
4接縫直線度2拉5m線,不足5m拉通線,用鋼直尺檢查
5壓條直線度2拉5m線,不足5m拉通線,用鋼直尺檢查
6接縫高低差1用鋼直尺和塞尺檢查
7.4裝配式吊頂
7.4.1裝配式吊頂工程應對下列隱蔽工程項目進行驗收:
1預埋件;
2連接構造;
3吊頂內管道、設備的安裝及管道試壓。
Ⅰ主控項目
7.4.2飾面材料的安裝應穩(wěn)固嚴密,連接構造符合設計要求。
檢驗方法:目測檢查、手扳檢查、尺量檢查、產品合格證書。
7.4.3飾面材料的材質、品種、圖案及顏色應符合設計要求。
檢驗方法:目測檢查、進場復驗(查看檢驗報告)、產品合格
證書。
7.4.4吊頂標高、尺寸、造型應符合設計要求
檢驗方法:目測檢查、尺量檢查。
33
Ⅱ一般項目
7.4.5飾面板與連接構造應平整、吻合,壓條應平直、寬窄一致;
飾面材料表面應潔凈、色澤一致,不得翹曲、裂縫及缺損。
檢驗方法:目測檢查、尺量檢查。
7.4.6飾面板上的燈具、噴淋頭、風口篦子等設備的位置應合理、
美觀,與飾面板的交接應吻合、嚴密。
檢驗方法:目測檢查。
7.4.7裝配式吊頂工程的允許偏差和檢驗方法應符合表7.4.7的
規(guī)定:
表7.4.7裝配式吊頂工程的允許偏差和檢驗方法
允許偏差(mm)
項次項目檢驗方法、檢查數(shù)量
飾面板
1表面平整度2用2m靠尺和塞尺檢查,各平面四角處
拉5m線(不足5m拉通線)用鋼直尺檢查,
接縫直線度
23各平面抽查兩處
用鋼直尺和塞尺檢查,同一平面檢查不少
3接縫高低差1
于3處
4水平度3在室內四角用尺量檢查
7.5裝配式樓地面
7.5.1裝配式樓地面工程應對下列隱蔽工程項目進行驗收:
1可調節(jié)支撐構造設置及安裝;
2樓地面架空層內管道、設備的安裝。
34
Ⅰ主控項目
7.5.2裝配式樓地面可調節(jié)支撐構造應符合設計要求,具有防火、
防腐性能。地面飾面板應符合設計要求,具有耐磨、防潮、阻燃、
耐污染及耐腐蝕等性能。
檢驗方法:進場復驗、查看檢測報告。
7.5.3裝配式樓地面鋪設允許偏差應符合現(xiàn)行國家標準《建筑地
面工程施工質量驗收規(guī)范》GB50209的規(guī)定。
7.5.4裝配式樓地面標高應符合設計要求,高度允許偏差為
±0.5mm。
檢驗方法:尺量檢查。
Ⅱ一般項目
7.5.5裝配式樓地面應排列整齊,接縫均勻,周邊順直。
檢驗方法:目測檢查。
7.5.6飾面層與可調節(jié)支撐構造應連接牢固,表面平整,接縫整
齊。
檢驗方法:目測檢查。
7.5.7裝配式樓地面工程與墻面或地面突出物周圍應吻合,邊緣
應整齊。樓地面與踢腳板交接應緊密,縫隙應順直。
檢驗方法:觀察、尺量檢查。
7.5.8踢腳板固定應牢固,高度、凸墻厚度應保持一致,上口應
平直;地板與踢腳板交接應緊密,縫隙順直。
檢驗方法:觀察、尺量、用小錘輕擊檢查。
7.5.9裝配式樓地面工程的允許偏差和檢驗方法應符合表7.5.9
35
規(guī)定。
表7.5.9裝配式樓地面工程的允許偏差和檢驗方法
項次項目允許偏差(mm)檢驗方法
1板面縫隙寬度±0.5用鋼尺檢查
2表面平整度2用2m靠尺和楔形塞尺檢查
3踢腳線上口平齊2拉5m通線,用鋼尺檢查
4板面拼縫平直2拉5m通線,用鋼尺檢查
5相鄰板材高差0.5用鋼尺和楔形塞尺檢查
6踢腳線與面層的接縫1楔型塞尺檢查
7.6集成廚房
7.6.1集成廚房應對下列隱蔽工程項目進行驗收:
1結構上固定整體收納系統(tǒng)埋件的位置、型號及連接方式;
2內裝部品成品管線與預留管線的接口連接。
Ⅰ主控項目
7.6.2櫥柜的材料、加工制作、使用功能應符合設計要求和國家
現(xiàn)行有關標準的規(guī)定。櫥柜應安裝牢固。
檢驗方法:觀察、手試和查閱相關資料。
7.6.3廚房設備的功能、配置和設置位置應符合設計要求。
檢驗方法:檢查設計文件。
36
Ⅱ一般項目
7.6.4集成廚房的安裝允許偏差和檢驗方法應符合表7.6.4的規(guī)
定。
表7.6.4集成廚房安裝允許偏差和檢驗方法
項次項目質量要求及允許偏差(mm)檢驗方法
表面應光潔平整,無裂紋、氣泡,顏色均
櫥柜和臺面等外表面觀察
1勻,外表沒有缺陷
洗滌池、灶具、操作臺、排
2尺寸誤差滿足設備安裝要求鋼尺測量
油煙機等設備接口
廚柜與頂棚、墻體等處的交
3接縫嚴密,交接線應順直、清晰、美觀觀察
接、嵌合,臺面與柜體結合
4外型尺寸3鋼尺測量
5兩端高低差2鋼尺測量
6柜立面垂直度
溫馨提示
- 1. 本站所有資源如無特殊說明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請下載最新的WinRAR軟件解壓。
- 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請聯(lián)系上傳者。文件的所有權益歸上傳用戶所有。
- 3. 本站RAR壓縮包中若帶圖紙,網(wǎng)頁內容里面會有圖紙預覽,若沒有圖紙預覽就沒有圖紙。
- 4. 未經權益所有人同意不得將文件中的內容挪作商業(yè)或盈利用途。
- 5. 人人文庫網(wǎng)僅提供信息存儲空間,僅對用戶上傳內容的表現(xiàn)方式做保護處理,對用戶上傳分享的文檔內容本身不做任何修改或編輯,并不能對任何下載內容負責。
- 6. 下載文件中如有侵權或不適當內容,請與我們聯(lián)系,我們立即糾正。
- 7. 本站不保證下載資源的準確性、安全性和完整性, 同時也不承擔用戶因使用這些下載資源對自己和他人造成任何形式的傷害或損失。
最新文檔
- 蘇聯(lián)談判協(xié)議書
- 苗木裝卸合同范本
- 葡萄管理協(xié)議書
- 融創(chuàng)集團協(xié)議書
- 認證費用協(xié)議書
- 設施拆除合同范本
- 評審勞務協(xié)議書
- 試驗費協(xié)議合同
- 工廠回收合同范本
- 工人復工協(xié)議書
- 托福真題試卷(含答案)(2025年)
- 2025年廣東省第一次普通高中學業(yè)水平合格性考試(春季高考)語文試題(含答案詳解)
- 2026廣東深圳市檢察機關招聘警務輔助人員13人筆試考試備考試題及答案解析
- 雨課堂學堂在線學堂云《金融風險管理:量化投資視角( 暨南)》單元測試考核答案
- 臨床試驗盲法方案設計的法規(guī)符合性優(yōu)化
- 留聲機美術課件
- 2026屆廣東深圳市高一生物第一學期期末監(jiān)測試題含解析
- 直播基地的管理制度
- 拍賣公司計劃書
- 水滸傳課件講宋江
- OA系統(tǒng)使用權限管理規(guī)范
評論
0/150
提交評論