版權(quán)說(shuō)明:本文檔由用戶提供并上傳,收益歸屬內(nèi)容提供方,若內(nèi)容存在侵權(quán),請(qǐng)進(jìn)行舉報(bào)或認(rèn)領(lǐng)
文檔簡(jiǎn)介
1、NJBST Co.,Ltd.QCD-015Rev.:0Page:1 of 8Title: PROCEDURE FOR LIQUID PENETRANT EXAMINATIONPROCEDURE FOR LIQUID PENETRANT EXAMINATION液體滲透檢驗(yàn)工藝規(guī)程CONTROLLED 在控本口UNCONTROLLED非在控本口COPY NO副本編號(hào):PREPARED BY制:DATE日期:REVIEWED BY審核:DATE日期:APPROVED BY批準(zhǔn):DATE日期:NJBST Co.,Ltd.QCD-015Rev.:0Page:2 of 8Title: PROCEDURE
2、FOR LIQUID PENETRANT EXAMINATIONDEMONSTRATION CERTIFICATIONThis is to certify that this procedure has been demonstrated on atest specimen with known defects to the satisfaction of the AuthorizedInspector according to ASMEDodeSection V, T-150 as required by the Section WDiv.1, Appendix 8.Test Specime
3、n No.:Demo. Report No.:NDE Level m : AI:NJBST Co.,Ltd.QCD-015Rev.:0Page:3 of 8Title: PROCEDURE FOR LIQUID PENETRANT EXAMINATION1. General1 .概述This procedure is applied to dye liquid penetrant examination of metal material and weldment for ASME Code items.This procedure is only suitable for detecting
4、 the defects that are open to the surface of material or weldment.This procedure shall be demonstrated to the satisfaction of the AI prior to implementation.2. Personnel2.1The personnel engaged in the penetrantexamination shall be qualifiedand certified inaccordance with the requirement of NJBSTCo.,
5、 Ltd. s“ Written Practice for NDE Personnel TrainingExamination,QualificationCertification (No.:QCD-011).3. Penetrant Materialsand3.1Theenetrant materials is intendedto. 1本規(guī)程適用于 ASM覬范產(chǎn)品金 屬材料和焊件著色液體滲透檢驗(yàn)。. 2本規(guī)程僅適用于探測(cè)材料或焊件 表面開(kāi)口類缺陷。. 3本規(guī)程在執(zhí)行之前,須演示至AI滿意。.人員從事液體滲透檢驗(yàn)的人員必須是 根據(jù)南京定色鈦業(yè)有限公司 (資料號(hào):QCD-011)進(jìn)行考試和資格
6、任命的 合格人員。. 滲透材料滲透材料包括檢驗(yàn)過(guò)程中使用的 所有滲透劑、溶劑或清洗劑、顯像劑等。液體滲透探傷材料,必須是指定 的和推薦的,見(jiàn)表 3.2。檢驗(yàn)使用的材 料必須是同一類型的。不允許用不同類 型的或不同制造廠的滲透材料混合使include all penetrnts, solvents or cleaning agents,developers, etc, used in the examination process.3.2 The liquid penetrant examination materialsshall be designated and recommended,a
7、s shownin Tablet ,制造廠材料鹿號(hào)衣3.2上海滬滲透劑HD-RS船助劑顯像劑HD-XS廠清洗劑HD-BX3.2. The materialsused for examination shall be thesame type. Intermixing of penetrant materials from different families or different manufacturers is notpermitted.Table 3.2 ManufacturerMaterialModelShanghaiPenetrantHD-RS(Ship Brand)Develop
8、erHD-XS3.3當(dāng)檢驗(yàn)奧氏體不銹鋼或鈦材時(shí),必須根據(jù)ASM覬范第V卷T-641(b)中 的程序,對(duì)所有材料分別分析氯和氟的 含量。殘留氯和氟總含量不得超過(guò)殘留 物重量的1%必須有制造廠相應(yīng)的合格 證。Cleaning AgentHD-BX3.3 When examining austenitic stainless steel or3.4當(dāng)檢查饃基合金時(shí),必須按照ASME 規(guī)范第V卷T-641(a)中的程序,對(duì)所有 材料分別分析硫含量。硫含量不得超過(guò) 殘留物重量的1%必須有制造廠相應(yīng)的 合格證。titanium,all materialsshall be analyzedindividua
9、lly for chlorine and fluorine content in accordance with the procedure shown in T-641(b) of ASMEDode Section V. The total chlorine plus fluorine content shall not exceed 1%of the residue by weight.The certificate of compliance from manufacturer be obtained.3.4W商悔躲陽(yáng)陽(yáng)0n nickebase alloys,materials shal
10、l be analyzed individually for sulphur content in accordance with the procedure shown in 丁-6414 of SecteaNVTnfeDuiinphur content shall not exceed 1%of the residue by weight. The certificatecompliance昨0佻胸汜取胡曲班到shall be obtained.表向制備預(yù)清洗,干燥施加滲透劑shallallofNJBST Co.,Ltd.QCD-015Cleaningtle: PROCEDURE FOR
11、LIQUID PENETRAN4. Examination ProcedurePage:4 of 8T EXAMINATION幣吉Rev.:04.1Fig.4.1.ExaminationFlow-Chart as shown inDrying4.檢驗(yàn)程序4.1檢驗(yàn)程序流程單僚圖4.1Development and Inspection顯像、檢驗(yàn)評(píng)定、記錄Evaluation and RecordPost Cleaning后清洗4.2圖4.1表面制備Fig. 4.14.2 Surface PreparationPrior to all penetrant examination, surface
12、 to be examined and all adjacent areasthe所有滲透檢驗(yàn)前,被檢工件表面及其附近至 少為1英寸(25.4mm)的區(qū)域內(nèi)都應(yīng)干燥清洗 干凈,不得有任何臟物、纖維屑、氧化皮、 焊劑、油和其它外來(lái)物。必要時(shí),應(yīng)對(duì)表面 進(jìn)行打磨或機(jī)加工。cleaned using cleaning agent before the penetrant is applied.4.3.2 After cleaning, drying of the surface to be examined shall be accomplished by normal evaporation or
13、 with forced air, as appropriate.The minimum drying time shall ensure that the cleaning solution has evaporated prior to application of the pepetrant.4.那能隔trant Applcation F0rmDwell Times (min)4.4.1 The penetrant may be appliednetr0nt DeveloperCastings & weldsQCD-015Wrought material- e TxtiesiOnR0cg
14、EDUREFOR0LIQUID PfNETsuitablemeanssuchas dipping, brushingor spraying.4.4.2 The temperature of the penetrant and the surface to be examined shall not be below 500F(10C) nor above125F(52C) throughout the examination period. When itexamination procedure at the proposed lower or higher temperature rang
15、e shall be qualified using a quench cracked aluminum block according to ASME Code Section V, T-6 Penetration time is critical. The minimumdwell time is shown in Table 4.4.3. For suitable temperature, the area being examined shall remain wetted by the penetrant for the dwell time.Table 4.4.3
16、Recommended minimum dwell timesbeRev材料型式滯留時(shí)間(min)滲透劑顯象劑鋁、鎂、鑄件和焊縫57)鋼、黃銅、Page:5of 8nTExA他TON1b板材107penetrantrange,thewithin at least 1in. (25.4mm) shall be dry and free of dirt, grease,lint, scale, welding flux, weld spatter , paint , oil and other extraneous matter. If necessary, surface shall be pr
17、epared by grinding or machining.4.3 PrecleaningThe areas to be examined and adjacent areas within at least 1in. (25.4mm) shall surfaceAluminum, magn-NJBSTCob囹5 or bronze, titanium and high temperatureofalWysrkpieces to Ipafexamined by any is not practical to conduct a liquid examination within above
18、 temperature在施加滲透劑之前,被檢區(qū)域及其附 近至少為1英寸(25.4mm)的區(qū)域內(nèi)均需用清 潔劑進(jìn)行清洗。清洗后,通過(guò)適當(dāng)?shù)姆椒?自然揮發(fā) 或人工通風(fēng)),對(duì)被檢表面進(jìn)行干燥;最少干 燥的時(shí)間以保證在施加滲透劑之前清潔劑已 完全揮發(fā)為界。施加滲透劑可以用浸漬、涂刷或噴涂等任一合適 的方法,在被檢工件在整個(gè)檢驗(yàn)期間,滲透劑和被檢表面的溫度不得低于500F(10 0C),不得高于 1250F(52 0C)O當(dāng)在上述溫度范圍內(nèi)不能滿足時(shí),則按照ASM覷范第V卷T-653 , 對(duì)提議采用的溫度范圍,使用有淬火 裂紋的鋁試塊進(jìn)行驗(yàn)證。嚴(yán)格控制滲透時(shí)間,最小滯留時(shí)間見(jiàn)表4.4.3 。適當(dāng)?shù)臏囟?/p>
19、條件 下,在滯留時(shí)間內(nèi),被檢區(qū)域必須用 滲透劑保持潮濕。表4.4.3推薦的最少滯留時(shí)間Excess Penetrant RemovalExcess solvent removable penetrant shall be removed by wiping with a cloth or absorbent paper. The remaining traces shall be removed by lightly wiping the surface with a cloth or absorbent paper moistened with solvent. To avoid over
20、removing, flushing the surface with solvent shall be prohibited.Developer ApplicationThe developer shall be applied as soon as possible after excess penetrant removal and drying surface. The surface may be dried by normal evaporation before the developer is applied. The drying time shall be within 5
21、 to 20 min.The developer shall be applied by spraying. A uniform thin coating shall be provided and the coating thickness shall be suitable.Prior to applying wet developer to the surface, the developer must be thoroughly agitated.Dipping or flooding the part with non-aqueous developer is prohibited,
22、 since it will dissolve the penetrant in the discontinuities through its solvent action.InterpretationDeveloping time for final interpretation begins多余滲透劑的清除多余滲透劑必須用布或吸紙擦去, 剩下的痕跡必須用蘸后溶劑的布或 紙?jiān)诒砻孑p輕地擦去。為了防止清洗 過(guò)分,禁止用溶劑清洗表面。施加顯像劑多余的滲透劑被清除且工件干燥后,必須盡快地施加顯像劑。顯 像劑施加之前,工件表面可以自然揮 發(fā)干燥,干燥時(shí)間必須在5-20分鐘以內(nèi)。施加顯像劑必須采用噴
23、涂法, 薄且均勻,涂層厚度適中。在施加濕型顯像劑至工件表 面之前,顯像劑必須充分?jǐn)嚢?。禁用非水濕顯像劑浸漬或灌 洗工件,因非水濕顯像劑會(huì)通過(guò)溶解 作用將缺陷中的滲透劑溶解掉。判斷最終判斷顯像時(shí)間應(yīng)從施加NJBST Co.,Ltd.QCD-015Rev.:0Page:6 of 8Title: PROCEDURE FOR LIQUID PENETRANT EXAMINATIONas soon as a wet developer coating is dry. The minimum developing time shall be 7min.Final interpretation shall
24、be madewithin 7 to 60 min after the requirements of Para. 4.7.1 are satisfied.The developing trace can be examined either by natural light or artificial light. A minumum lightintensity of 50 fc (500Lx) is required to ensure adequate sensitivityduring the examination andevaluation of indications.The
25、surface shall be divided into several parts to be examined if the surface is so large that the干顯像劑后或從濕顯像劑涂層干燥后 立即起算,不得少于7分鐘。在滿足4.7.1要求后,最終判 斷必須在7-60分鐘內(nèi)作出。顯像痕跡可以通過(guò)自然光或人 工白光進(jìn)行檢驗(yàn),要求最小燈光強(qiáng)度 為50fc(500LX),以保證在檢驗(yàn)和評(píng)價(jià) 顯示過(guò)程中有充分的靈敏度。如果受檢表向太大,無(wú)法在規(guī) 定時(shí)間內(nèi)完成檢驗(yàn),則應(yīng)將表面分成 幾個(gè)部進(jìn)行檢驗(yàn)。顯像情況可以用肉 眼或放大鏡進(jìn)行觀察。4.8后清洗檢驗(yàn)后,必須完全清除工件上的滲
26、透examination can not be finished within the given time. The developing condition can be observed either by eyes or by means of a magnifier.4.8 Post-cleaningThe penetrant materials shall be clearly removed away from parts after examination. The post cleaning must be performed if remaining penetrant m
27、aterials can result in corrosion by the combination with other materials during the operation.The suitable cleaning process shall be adopted for post cleaning such as flushing with water, mechanical cleaning, solvent soaking, etc.The developer shall be cleaned as soon as possible after examination i
28、f the part requests the post cleaning so as to avoid it condensed on the part.Evaluation of IndicationsBroad areas of pigmentation which could mask indications of discontinuities are unacceptable and such areas shall be cleaned and reexamined.An indication is the evidence of a mechanical imperfectio
29、n. Only indications with major dimensions greater than 1/16in(1.6mm) shall be consideredrelevant.Linear indications are those indications in which the length is more than three times the width . Rounded indications are indications which are circular or ellipsoidal with the length less than three tim
30、es the width.Any questionable or doubtful indications shall be reexamined to determine whether or not they are relevant. Surface conditioning may proceed before the reexamination.The indication of a discontinuity may be larger than the discontinuity that causes it; however, the size of the indicatio
31、n is the basis of acceptance or rejection.Acceptance StandardsThe following relevant indications are unacceptable: a. any cracks or relevant linear indications;relevant rounded indications greater than 3/16in. (4.8mm);材料,如果殘余滲透材料在操作過(guò)程 中與其它材料混合后會(huì)導(dǎo)致腐蝕,則 必須進(jìn)行后清洗??梢圆捎萌缬盟疀_ 洗、機(jī)械清潔、溶劑浸泡等適當(dāng)?shù)那?潔工作,來(lái)進(jìn)行后清洗。如果需要后清洗,則檢驗(yàn)后必須盡快 進(jìn)行,以免顯像劑凝固在工件上。. 顯示評(píng)價(jià)大面積顏料沉淀會(huì)掩蓋缺陷顯 示,是不合格的,這些區(qū)域
溫馨提示
- 1. 本站所有資源如無(wú)特殊說(shuō)明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請(qǐng)下載最新的WinRAR軟件解壓。
- 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請(qǐng)聯(lián)系上傳者。文件的所有權(quán)益歸上傳用戶所有。
- 3. 本站RAR壓縮包中若帶圖紙,網(wǎng)頁(yè)內(nèi)容里面會(huì)有圖紙預(yù)覽,若沒(méi)有圖紙預(yù)覽就沒(méi)有圖紙。
- 4. 未經(jīng)權(quán)益所有人同意不得將文件中的內(nèi)容挪作商業(yè)或盈利用途。
- 5. 人人文庫(kù)網(wǎng)僅提供信息存儲(chǔ)空間,僅對(duì)用戶上傳內(nèi)容的表現(xiàn)方式做保護(hù)處理,對(duì)用戶上傳分享的文檔內(nèi)容本身不做任何修改或編輯,并不能對(duì)任何下載內(nèi)容負(fù)責(zé)。
- 6. 下載文件中如有侵權(quán)或不適當(dāng)內(nèi)容,請(qǐng)與我們聯(lián)系,我們立即糾正。
- 7. 本站不保證下載資源的準(zhǔn)確性、安全性和完整性, 同時(shí)也不承擔(dān)用戶因使用這些下載資源對(duì)自己和他人造成任何形式的傷害或損失。
最新文檔
- 2025年省屬國(guó)企公開(kāi)招聘?jìng)淇碱}庫(kù)完整答案詳解
- 2025年杭州之江灣股權(quán)投資基金管理有限公司招聘?jìng)淇碱}庫(kù)及一套答案詳解
- 2025年景洪市嘎灑強(qiáng)村管理有限公司人員招聘?jìng)淇碱}庫(kù)及參考答案詳解1套
- 2025年鄂倫春自治旗人民醫(yī)院消防人員招聘?jìng)淇碱}庫(kù)附答案詳解
- 2025年鄂爾多斯市勝豐種業(yè)有限公司科研助理招聘?jìng)淇碱}庫(kù)及完整答案詳解1套
- 2026年天津高級(jí)中學(xué)-骨干教師及青年教師招聘?jìng)淇碱}庫(kù)及參考答案詳解一套
- 2025年郴州市第三人民醫(yī)院?jiǎn)T工招聘?jìng)淇碱}庫(kù)及完整答案詳解1套
- 2025年中國(guó)瑞林工程技術(shù)股份有限公司杭州分公司(國(guó)企上市公司)招聘結(jié)構(gòu)設(shè)計(jì)師備考題庫(kù)帶答案詳解
- 2025年江門市江海區(qū)銀信資產(chǎn)管理有限公司招聘?jìng)淇碱}庫(kù)及參考答案詳解一套
- 滄州市中心醫(yī)院2026年度高層次人才選聘170人備考題庫(kù)及1套參考答案詳解
- sw水箱施工方案
- 2023-2024學(xué)年廣東省廣州市海珠區(qū)八年級(jí)(上)期末地理試題及答案
- 旅游策劃理論及實(shí)務(wù)第1章旅游策劃導(dǎo)論
- 中華人民共和國(guó)治安管理處罰法2025修訂版測(cè)試題及答案
- 產(chǎn)品生命周期管理(PLM)方案
- istqb考試題目及答案
- 2025年嫩江市招聘農(nóng)墾社區(qū)工作者(88人)筆試備考試題附答案詳解(a卷)
- 展廳空間設(shè)計(jì)案例
- 企業(yè)降本增效課件
- 中醫(yī)護(hù)理技術(shù)提升與臨床應(yīng)用
- 兗礦新疆煤化工有限公司年產(chǎn)60萬(wàn)噸醇氨聯(lián)產(chǎn)項(xiàng)目環(huán)評(píng)報(bào)告
評(píng)論
0/150
提交評(píng)論