CNG加氣站可行性研究報(bào)告/r/n /r/n項(xiàng)目編號(hào)/r/n:/r/n/r/n/r/n目錄/r/nTOC\o"1-2"\h\z\u/r/n/r/n1./r/n總論/r/n /r/n/r/n6/r/n/r/n1.1/r/n項(xiàng)目概況/r/n /r/n/r/n6/r/n/r/n1.2/r/n編制依據(jù)/r/n /r/n/r/n6/r/n/r/n1.3/r/n工程建設(shè)的必要性和可行性/r/n /r/n/r/n7/r/n/r/n1.4/r/n編制原則/r/n /r/n/r/n8/r/n/r/n1.5/r/n編制范圍和要求/r/n /r/n/r/n8/r/n/r/n1.6/r/n工程內(nèi)容概述/r/n /r/n/r/n9/r/n/r/n1.8/r/n結(jié)論/r/n /r/n/r/n10/r/n/r/n2/r/n站址選擇/r/n /r/n/r/n12/r/n/r/n2.1/r/n站址選擇的原則/r/n /r/n/r/n12/r/n/r/n2.2/r/n本站站址選擇/r/n /r/n/r/n12/r/n/r/n3/r/n站內(nèi)總平面布置/r/n /r/n/r/n13/r/n/r/n3.1/r/n本站總平面布置一般原則/r/n /r/n/r/n13/r/n/r/n3.2/r/n站內(nèi)分區(qū)/r/n /r/n/r/n13/r/n/r/n3.3/r/n站區(qū)圍墻/r/n /r/n/r/n13/r/n/r/n3.4/r/n罩棚和廠房/r/n /r/nPAGE/r/nREF_Toc300838814\h/r/n13/r/n/r/n3.5/r/n本站站內(nèi)設(shè)施之間的防火距離/r/n /r/n/r/n13/r/n/r/n4CNG/r/n加氣站工藝設(shè)計(jì)/r/n /r/n/r/n14/r/n/r/n4.1/r/n加氣站工藝流程/r/n /r/n/r/n17\h/r/n14/r/n/r/n4.2/r/n天然氣質(zhì)量標(biāo)準(zhǔn)/r/n /r/n/r/n14/r/n/r/n4.3/r/n加氣站工藝設(shè)施的安全保護(hù)/r/n /r/n/r/n14/r/n/r/n4.4/r/n工藝設(shè)施的選擇/r/n /r/n/r/n14/r/nHYP/r/nERLINK/r/n4.5CNG/r/n加氣站管道及管件選擇/r/n /r/n/r/n20/r/n/r/n4.6/r/n計(jì)量裝置選擇/r/n /r/n/r/n20/r/n/r/n5/r/n建筑設(shè)計(jì)/r/n /r/n/r/n20/r/n/r/n5.1/r/n遵循的主要規(guī)范:/r/n /r/n/r/n20/r/n/r/n5.2/r/n建筑設(shè)計(jì)的安全要求/r/n /r/n/r/n20/r/n/r/n5.3/r/n建筑設(shè)計(jì)的美觀要求/r/n /r/n/r/n21/r/n/r/n5.4/r/n建筑物的節(jié)能設(shè)計(jì)/r/n /r/n/r/n21/r/n/r/n5.5
/r/n建筑物一覽表/r/n /r/n/r/n21/r/n/r/n6/r/n采暖與通風(fēng)/r/n /r/n/r/n21/r/n/r/n6.1/r/n采暖/r/n /r/n/r/n21/r/n/r/n6.2/r/n通風(fēng)/r/n /r/n/r/n22/r/n/r/n7/r/n消防系統(tǒng)設(shè)計(jì)/r/n /r/n/r/n22/r/n/r/n7.1/r/n應(yīng)遵循的主要設(shè)計(jì)規(guī)范/r/n /r/n/r/n22/r/n/r/n7.2/r/n消防系統(tǒng)設(shè)計(jì)概述/r/n /r/n/r/n22/r/n/r/n7.3/r/n消防系統(tǒng)設(shè)計(jì)的安全措施/r/n /r/n/r/n22/r/n/r/n7.4/r/n滅火器材配置/r/n /r/n/r/n23/r/n/r/n7.5/r/n可燃?xì)怏w檢測(cè)器/r/n /r/n/r/n24/r/n/r/n7.6/r/n消防安全機(jī)構(gòu)、消防管理制度和事故搶險(xiǎn)預(yù)案/r/n /r/n/r/n24/r/n/r/n8/r/n電氣設(shè)計(jì)/r/n /r/n/r/n24/r/n/r/n8.1/r/n供配電系統(tǒng)/r/n /r/nPAGEREF_T/r/noc300838840\h/r/n24/r/n/r/n8.2/r/n電纜敷設(shè)/r/n /r/n/r/n25/r/n/r/n8.3/r/n防爆區(qū)域劃/r/n分/r/n和防爆電氣選擇/r/n /r/n/r/n25/r/n/r/n8.4/r/n防雷設(shè)計(jì)/r/n /r/n/r/n26/r/n/r/n8.5/r/n防靜電設(shè)計(jì)/r/n /r/n/r/n26/r/n/r/n9/r/n自控和儀表/r/n /r/n/r/n26/r/n/r/n9.1CNG/r/n加氣站的控制系統(tǒng)/r/n /r/n/r/n26/r/n/r/n9.2CNG/r/n加氣站的儀表設(shè)置/r/n /r/n/r/n27/r/n/r/n10/r/n壓力容器、壓力管道設(shè)計(jì)/r/n /r/n/r/n27/r/n/r/n10.1/r/n概述/r/n /r/n/r/n27/r/n/r/n10.2/r/n遵循的主要規(guī)范/r/n /r/n/r/n27/r/n/r/n10.3/r/n壓力容器、壓力管道的設(shè)計(jì)原則/r/n /r/n/r/n27/r/n/r/n10.4/r/n儲(chǔ)氣設(shè)施的比較及方案選擇/r/n /r/n/r/n28/r/n/r/n10.5/r/n壓力管道的設(shè)計(jì)/r/n /r/nPAG/r/nEREF_Toc300838853\h/r/n28/r/n/r/n10.6/r/n壓力容器、壓力管道的安全保護(hù)/r/n /r/n/r/n28/r/n/r/n10.7/r/n壓力容器、壓力管道的分級(jí)品種及分類/r/n /r/n/r/n28/r/n/r/n10.8/r/n壓力管道設(shè)計(jì)、安裝、運(yùn)行的安全監(jiān)察/r/n /r/n/r/n29/r/n/r/n11/r/n勞動(dòng)安全與工業(yè)衛(wèi)生/r/n /r/n/r/n29/r/n/r/n11.1/r/n應(yīng)遵循的勞動(dòng)安全衛(wèi)生規(guī)程和標(biāo)準(zhǔn)/r/n /r/n/r/n29/r/n/r/n11.2/r/n生產(chǎn)中能產(chǎn)生的職業(yè)危害以及造成危害的因素/r/n /r/n/r/n29/r/n/r/n11.3/r/n勞動(dòng)安全和工業(yè)衛(wèi)生措施/r/n /r/n/r/n30/r/n/r/n12/r/n環(huán)境保護(hù)/r/n /r/n/r/n31/r/n/r/n12.1/r/n設(shè)計(jì)依據(jù)及規(guī)范/r/n /r/n/r/n00838862\h/r/n31/r/n/r/n12.2/r/n本項(xiàng)目環(huán)保意義/r/n /r/n/r/n31/r/n/r/n12.3/r/n工程投產(chǎn)運(yùn)行后的污染源概況/r/n /r/n/r/n31/r/n/r/n12.4/r/n本項(xiàng)目污染源分析/r/n /r/n/r/n31/r/n/r/n12.5/r/n設(shè)計(jì)采取的環(huán)境保護(hù)措施/r/n /r/n/r/n32/r/n/r/n13/r/n節(jié)能評(píng)價(jià)/r/n /r/n/r/n33/r/n/r/n13.1/r/n本項(xiàng)目主要耗能的部位及能源種類/r/n /r/n/r/n33/r/nHYPERL/r/nINK/r/n13.2/r/n節(jié)能措施/r/n /r/n/r/n33/r/n/r/n13.3/r/n節(jié)能評(píng)價(jià)/r/n /r/n/r/n33/r/n/r/n14/r/n項(xiàng)目實(shí)施及人員培訓(xùn)/r/n /r/n/r/n34/r/n/r/n1/r/n4.1/r/n工作制度/r/n /r/n/r/n34/r/n/r/n14.2/r/n勞動(dòng)組織及定員/r/n /r/n/r/n34/r/n/r/n14.3/r/n人員培訓(xùn)/r/n /r/n/r/n34/r/n/r/n15/r/n主要設(shè)備表/r/n /r/n/r/n0838875\h/r/n35/r/n/r/n16/r/n總投資估算/r/n /r/n/r/n36/r/n/r/n16.2/r/n資金來源及使用計(jì)劃/r/n /r/n/r/n37/r/n/r/n16.3/r/n經(jīng)濟(jì)評(píng)價(jià)/r/n /r/n/r/n37/r/nHYPERLINK/r/n/r/n16.3.1/r/n說明/r/n /r/n/r/n37/r/n/r/n16.3.2/r/n基礎(chǔ)數(shù)據(jù)/r/n /r/n/r/n37/r/n/r/n17./r/n結(jié)論及建議/r/n /r/n/r/n40/r/n/r/n17.1/r/n結(jié)論/r/n /r/n/r/n40/r/n/r/n17.2/r/n建議/r/n /r/n/r/n41/r/n1.總論/r/n1.1/r/n項(xiàng)目概況/r/n(1)項(xiàng)目名稱/r/nCNG/r/n加氣站可行性研究報(bào)告/r/n(2)建設(shè)單位/r/n(3)建設(shè)規(guī)模/r/n建設(shè)單位擬在/r/n/r/n建設(shè)一座/r/nCNG/r/n加氣站,/r/nCNG/r/n加氣站初期設(shè)計(jì)規(guī)模為30000Nm/r/n3/r/n/d。/r/n(4)/r/n建設(shè)單位簡介/r/n1/r/n.2編制依據(jù)/r/n1/r/n.2.1/r/n1/r/n.2.2/r/n《城鎮(zhèn)燃?xì)庠O(shè)計(jì)規(guī)范》GB50028-93(2002年)/r/n《汽車加油加氣站設(shè)計(jì)與施工規(guī)范》GB50156-2002(2006年版)/r/n《建筑設(shè)計(jì)防火規(guī)范》GBJ16-87(2001年)/r/n《建筑滅火器配置設(shè)計(jì)規(guī)范》GB50140-2005/r/n《壓力容器安全技術(shù)監(jiān)察規(guī)程》質(zhì)技監(jiān)局鍋發(fā)[1999]154號(hào)/r/n《壓力管道安全管理與監(jiān)察規(guī)定》勞部發(fā)[1996]140號(hào)/r/n《建筑給水排水及采暖工程施工質(zhì)量驗(yàn)收規(guī)范》GB50242-2002/r/n《建筑給水排水設(shè)計(jì)規(guī)范》GB50015-2003/r/n《建筑物防雷設(shè)計(jì)規(guī)范》GB50057-94/r/n《低壓配電裝置及線路設(shè)計(jì)規(guī)范》GBJ54-83/r/n《爆炸和火災(zāi)危險(xiǎn)環(huán)境電氣裝置設(shè)計(jì)規(guī)范》GB50058-92/r/n《化工企業(yè)靜電接地設(shè)計(jì)技術(shù)規(guī)范》CD90A3-83/r/n《工業(yè)與民用供電系統(tǒng)設(shè)計(jì)技術(shù)規(guī)范》GBJ50052-95/r/n(《工業(yè)企業(yè)設(shè)計(jì)衛(wèi)生標(biāo)準(zhǔn)》GBZ1-2002/r/n《大氣環(huán)境質(zhì)量標(biāo)準(zhǔn)》GBJ3095-96/r/n《工業(yè)企業(yè)噪聲控制設(shè)計(jì)規(guī)范》GBJ87-85/r/n《公共建筑節(jié)能設(shè)計(jì)標(biāo)準(zhǔn)》GB50189-2005/r/n1/r/n.3工程建設(shè)的必要性和可行性/r/n1/r/n.3.1/r/n改善生態(tài)環(huán)境,減少城市大氣污染,具有顯著的環(huán)保效益?,F(xiàn)在城市機(jī)動(dòng)車尾氣污染相當(dāng)嚴(yán)重,機(jī)動(dòng)車尾氣中一氧化碳、氮氧化合物及碳?xì)浠衔锏戎饕廴疚镔|(zhì)對(duì)環(huán)境空氣濃度的實(shí)際分擔(dān)率已超過60%,城市環(huán)境空氣已從煤煙型污染為主轉(zhuǎn)變?yōu)槊簾煟瓩C(jī)動(dòng)車尾氣復(fù)合型污染。因此,在治理大氣污染的同時(shí),必須大力推廣清潔燃料,發(fā)展以天然氣為動(dòng)力的壓縮天然氣汽車。/r/n被稱為/r/n“/r/n綠色汽車/r/n”/r/n的天然氣汽車在環(huán)保方面具有顯著效益。用天然氣作為動(dòng)力與使用汽油作為動(dòng)力相比較,汽車尾氣中一氧化碳可減少97%,碳?xì)浠衔餃p少72%,二氧化碳減少90%,噪音減少40%,導(dǎo)致人體呼吸道疾病及癌癥的苯、鉛粉塵等減少100%。/r/n發(fā)展天然氣汽車的經(jīng)濟(jì)效益顯著。隨著天然氣汽車和CNG加氣站的運(yùn)行,將帶動(dòng)與天然氣汽車相關(guān)的機(jī)械制造、汽車、高壓貯運(yùn),電子電器、儀器儀表、新工藝、新材料、試驗(yàn)檢測(cè)以及教育培訓(xùn)業(yè)等行業(yè)的發(fā)展,使天然氣汽車的推廣應(yīng)用成為龍頭,創(chuàng)造上千個(gè)就業(yè)機(jī)會(huì),促進(jìn)社會(huì)經(jīng)濟(jì)的發(fā)展。/r/n1/r/n.3.2/r/n城市市長安區(qū)交通方便,公路四通八達(dá),為貫徹城市可持續(xù)發(fā)展戰(zhàn)略,加快城市建設(shè)步伐,保護(hù)城市生態(tài)環(huán)境,調(diào)整城市燃料與能源結(jié)構(gòu),改善投資環(huán)境,長安區(qū)建設(shè)天然氣汽車加氣站勢(shì)在必行。/r/n天然氣作為汽車燃料,它比燃油費(fèi)用要節(jié)約25~35%左右,以氣代油的經(jīng)濟(jì)效益較為可觀。按保守估算,一般出租車每天可以節(jié)約40余元,年可節(jié)省1.4余萬元,公交大巴車每天節(jié)約80多元,年可節(jié)約2.64萬元,中小巴車每天節(jié)約50多元,年可節(jié)約1.83萬元。此外,天然氣抗爆性好,發(fā)動(dòng)機(jī)效率高、噪聲低、氣缸不積炭,機(jī)油消耗低,發(fā)動(dòng)機(jī)磨損小,可以大大降低維修費(fèi)用,提高車輛使用壽命,較大程度地提高車主的經(jīng)濟(jì)效益。/r/n1/r/n.4編制原則/r/n1/r/n.4.1/r/n1/r/n.4.2/r/n1/r/n.4.3/r/n1/r/n.4.4/r/n1/r/n.5編制范圍和要求/r/n1/r/n.5.1/r/n1/r/n.5.2/r/n1/r/n.5.3/r/n1/r/n.6工程內(nèi)容概述/r/n1/r/n.6.1/r/n本工程設(shè)計(jì)加氣能力為/r/n3/r/n萬Nm/r/n3/r/n/日??傉嫉孛娣e/r/n2000/r/nm/r/n2/r/n,總投資/r/n502.9/r/n萬/r/n元左右。/r/n1/r/n.6.2/r/n(1)土建工程:裝置區(qū)廠房、站房、加氣區(qū)罩棚、圍墻及設(shè)備基礎(chǔ)等。/r/n(2)安裝工程:站區(qū)進(jìn)氣、壓縮、干燥、儲(chǔ)氣、售氣等系統(tǒng)及其配套的控制、變配電系統(tǒng)。/r/n1.7/r/n/r/n主要經(jīng)濟(jì)指標(biāo)/r/n主要技術(shù)經(jīng)濟(jì)指標(biāo)表/r/n表1.5/r/n序號(hào)/r/n指標(biāo)/r/n單位/r/n數(shù)量/r/n備注/r/n1/r/n生產(chǎn)規(guī)模/r/n1.1/r/n加氣能力/r/nNm/r/n3/r/n//r/nd/r/n30000/r/n1.2/r/n年工作天數(shù)/r/n天/r/n3/r/n6/r/n0/r/n2/r/n原料/r/n2.1/r/n進(jìn)氣/r/n萬Nm/r/n3/r/n//r/na/r/n1080/r/n3/r/n公用動(dòng)力消耗量/r/n3./r/n1/r/n新鮮水/r/nt/r/n//r/na/r/n720/r/n3./r/n2/r/n年耗電量/r/n萬k/r/nW/r/nh/a/r/n10.23/r/n4/r/n定員/r/n人/r/n10/r/n5/r/n罐區(qū)面積/r/nm/r/n2/r/n154/r/n5.1/r/n輔助控制撬占地面積/r/nm/r/n2/r/n15/r/n6/r/n建設(shè)項(xiàng)目總投資額/r/n萬元/r/n502.9/r/n6.1/r/n建設(shè)投資(不含建設(shè)期利息)/r/n萬元/r/n489.17/r/n6.2/r/n建設(shè)期貸款利息/r/n萬元/r/n0.00/r/n6.3/r/n鋪底流動(dòng)資金/r/n萬元/r/n4.12/r/n7/r/n年均銷售收入/r/n萬元/r/n4450/r/n8/r/n年均總成本費(fèi)用/r/n萬元/r/n1733/r/n9/r/n年均利潤總額/r/n萬元/r/n2664/r/n10/r/n全員勞動(dòng)生產(chǎn)率/r/n產(chǎn)值萬元/人.年/r/n11/r/n財(cái)務(wù)評(píng)價(jià)指標(biāo)/r/n所得稅前財(cái)務(wù)內(nèi)部收益率/r/n%/r/n27.47/r/n所得稅后財(cái)務(wù)內(nèi)部收益率/r/n%/r/n22.39/r/n所得稅前財(cái)務(wù)凈現(xiàn)值/r/n萬元/r/n548.14/r/n所得稅后財(cái)務(wù)凈現(xiàn)值/r/n萬元/r/n348.15/r/n稅前投資回收期/r/n年/r/n4.84/r/n稅后投資回收期/r/n年/r/n5.57/r/n資本金財(cái)務(wù)內(nèi)部收益率/r/n%/r/n22.39/r/n資本金財(cái)務(wù)凈現(xiàn)值/r/n萬元/r/n348.15/r/n12/r/n借款償還期/r/n年/r/n0/r/n13/r/n盈虧平衡點(diǎn)/r/n%/r/n33.77/r/n1/r/n.8結(jié)論/r/n1/r/n.8.1/r/n(1)本項(xiàng)目總投資額:/r/n502.9/r/n萬元。(2)本項(xiàng)目全部資金由企業(yè)自籌。/r/n1/r/n.8.2/r/n社會(huì)效益/r/n本項(xiàng)目建成后由于所供的CNG汽車尾氣排放污染減輕,從而減少了環(huán)境污染,改善了城市大氣質(zhì)量,再則節(jié)約了能源,降低了運(yùn)輸成本。/r/n1/r/n.8.3/r/n本項(xiàng)目的建設(shè)技術(shù)成熟可行,設(shè)備先進(jìn),選址合理符合國家環(huán)保、能源政策,是國家重點(diǎn)支持的產(chǎn)業(yè)工程,項(xiàng)目建成后的經(jīng)濟(jì)效益顯著,投資回收期較短,社會(huì)效益明顯,本項(xiàng)目是完全可行的。/r/n2/r/n站址選擇/r/n2/r/n.1站址選擇的原則/r/n2/r/n.1.1/r/nCNG加氣站站址選擇的原則,應(yīng)符合城市總體規(guī)劃、消防安全和環(huán)境保護(hù)的要求,并應(yīng)選擇在交通便利、車流量較大的地方。/r/n2/r/n.1.2/r/n(1)站址選擇應(yīng)符合《建筑設(shè)計(jì)防火規(guī)范》和《汽車加油加氣站設(shè)計(jì)與施工規(guī)范》的防火安全要求;/r/n(2)避開重要建筑物和人流密集區(qū);/r/n(3)遠(yuǎn)離明火場(chǎng)所。/r/n2/r/n.2本站站址選擇/r/n本站址位于交通便利,車流量較大。/r/n本站占地面積:/r/n2000m/r/n2/r/n。/r/n建站外部條件優(yōu)越,均在防火間距之外。/r/n3/r/n站內(nèi)總平面布置/r/n3/r/n.1本站總平面布置一般原則/r/n3/r/n.1.1/r/n4.1.2/r/n站內(nèi)場(chǎng)地通暢,站內(nèi)加氣區(qū)開闊,方便以后大型車輛或消防車輛的進(jìn)出。/r/n3/r/n.2站內(nèi)分區(qū)/r/n /r/n3/r/n.2.1/r/n3/r/n.2.2/r/n3/r/n./r/n3/r/n站區(qū)圍墻/r/n站區(qū)設(shè)置高度為2.2米的非燃燒實(shí)體圍墻,防止站內(nèi)天然氣泄漏時(shí)影響到站外或站外火源飛入站內(nèi)。/r/n3/r/n./r/n4/r/n罩棚/r/n和廠房/r/n加氣區(qū)罩棚的設(shè)置面積為/r/n150/r/n㎡,考慮到大型公交車的高度以及罩棚面積與高度的協(xié)調(diào)等問題,加氣區(qū)罩棚凈空高度設(shè)計(jì)為5.0米。/r/n裝置區(qū)廠房的設(shè)置根據(jù)設(shè)備的高度以及《汽車加油加氣站設(shè)計(jì)與施工規(guī)范》的有關(guān)規(guī)定,裝置區(qū)廠房凈空高度設(shè)計(jì)為5.0米。/r/n3/r/n./r/n5/r/n本站站內(nèi)設(shè)施之間的防火距離/r/n設(shè)施名稱/r/n儲(chǔ)氣井/r/n放散口/r/n壓縮機(jī)/r/n干燥器/r/n售氣機(jī)/r/n箱變/r/n道路/r/n圍墻/r/n站房/r/n儲(chǔ)氣井/r/n1.5/r/n-/r/n3/r/n5/r/n6/r/n6/r/n4/r/n3/r/n5/r/n放散口/r/n-/r/n-/r/n-/r/n-/r/n6/r/n6/r/n4/r/n3/r/n5/r/n壓縮機(jī)/r/n-/r/n-/r/n-/r/n4/r/n6/r/n2/r/n2/r/n5/r/n干燥器/r/n-/r/n-/r/n-/r/n5/r/n6/r/n2/r/n3/r/n5/r/n售氣機(jī)/r/n-/r/n6/r/n-/r/n-/r/n5/r/n注:分?jǐn)?shù)線上數(shù)字為規(guī)范GB50156-2002要求距離,分?jǐn)?shù)線下數(shù)字為實(shí)際距離。/r/n4/r/nCNG加氣站工藝設(shè)計(jì)/r/n4/r/n.1加氣站工藝流程/r/n/r/n過濾器/r/n→/r/n流量計(jì)/r/n→/r/n截?cái)嚅y井/r/n→/r/n順序控制盤/r/n→/r/n干燥器/r/n→/r/n壓縮機(jī)組/r/n→/r/n緩沖罐/r/n→/r/n儲(chǔ)氣井組/r/n→/r/n售氣機(jī)/r/n→/r/n天然氣/r/n→/r/n加氣車/r/n /r/n本站/r/n含硫指標(biāo)已符合《車用壓縮天然氣》GB18047-2000,故本站不設(shè)脫硫裝置,首先經(jīng)過濾后進(jìn)入計(jì)量裝置,然后進(jìn)入緩沖罐,穩(wěn)壓后進(jìn)入壓縮機(jī)組增壓至25Mpa,增壓后的天然氣進(jìn)入雙塔式前置干燥器,經(jīng)脫水后的天然氣通過順序控制盤進(jìn)入儲(chǔ)氣井組儲(chǔ)氣,或通過加氣機(jī)向CNG汽車加氣。/r/n4/r/n.2天然氣質(zhì)量標(biāo)準(zhǔn)/r/n進(jìn)站天然氣的質(zhì)量符合國家標(biāo)準(zhǔn)GB17820《天然氣》中規(guī)定的II類氣質(zhì)標(biāo)準(zhǔn),進(jìn)入壓縮機(jī)的天然氣質(zhì)量符合壓縮運(yùn)行要求的有關(guān)規(guī)定,增壓后進(jìn)入儲(chǔ)氣井及出站的壓縮天然氣符合GB18047《汽車用壓縮天然氣》中規(guī)定的氣質(zhì)標(biāo)準(zhǔn)。/r/n4/r/n.3加氣站工藝設(shè)施的安全保護(hù)/r/n4/r/n.3.1/r/n4/r/n.3.2/r/n4/r/n.3.3/r/n4/r/n.3.4/r/n4/r/n.3.5/r/n4/r/n.4工藝設(shè)施的選擇/r/n4/r/n.4.1/r/n(1)早期的壓縮天然氣加氣站,大多采用國外設(shè)備,但國外設(shè)備配件價(jià)格、維修費(fèi)用昂貴,對(duì)氣質(zhì)要求較高。近幾年來,我國國產(chǎn)壓縮機(jī)的制造質(zhì)量有了長足進(jìn)步,且價(jià)格相對(duì)低廉,而且配件及售后服務(wù)方面更具有較大優(yōu)勢(shì),故本報(bào)告選擇國產(chǎn)壓縮機(jī)廠家的產(chǎn)品。/r/n(2)由于壓縮機(jī)有可能長時(shí)間運(yùn)行,氣缸和級(jí)間產(chǎn)生過熱,需要冷卻。壓縮機(jī)的冷卻方式分為風(fēng)冷、水冷和水風(fēng)混合冷。壓縮機(jī)的冷卻方式與設(shè)備的制造工藝、材質(zhì)、使用頻率及使用地氣溫密切關(guān)聯(lián)。國外壓縮機(jī)普通采用風(fēng)冷方式,這主要是因?yàn)閲獾牟馁|(zhì)、制造工藝以及使用狀況較之國內(nèi)優(yōu)越。我國國產(chǎn)CNG壓縮機(jī)的制造工藝也在不斷的提高,也有采用風(fēng)冷、水風(fēng)混冷的冷卻方式,但是CNG加氣站的使用狀況卻不能同國外比較。相當(dāng)一部分CNG加氣站,開車頻率太高,運(yùn)轉(zhuǎn)時(shí)間太長,加之城市夏季的高溫天氣(根據(jù)有關(guān)氣象資料統(tǒng)計(jì),氣溫在35/r/n℃/r/n~40/r/n℃/r/n之間的天氣每年約一個(gè)半月時(shí)間),也就是說高溫持續(xù)時(shí)間的風(fēng)也是熱風(fēng)。故本工程選用水冷方式冷卻,設(shè)置冷卻水塔、冷卻用水蓄水池及軟水處理器。壓縮機(jī)主要技術(shù)參數(shù)見下表:/r/n壓縮機(jī)主要技術(shù)參數(shù)表/r/n序號(hào)/r/n項(xiàng)目/r/n技術(shù)參數(shù)/r/n備注/r/n1/r/n結(jié)構(gòu)型式/r/n水冷活塞式/r/n2/r/n介質(zhì)/r/n凈化天然氣H/r/n2/r/nS含量<15mg/Nm/r/n3/r/n無游離液/r/n3/r/n吸氣壓力/r/n0.2Mpa/r/n4/r/n壓縮機(jī)轉(zhuǎn)速/r/n740r/min/r/n5/r/n排氣壓力/r/n25Mpa(表壓)/r/n6/r/n壓縮級(jí)數(shù)/r/n4級(jí)/r/n7/r/n容積流量/r/n3.8m/r/n3/r/n/min/r/n8/r/n排氣量/r/n660Nm/r/n3/r/n/h/r/n9/r/n傳動(dòng)方式/r/n直聯(lián)/r/n10/r/n主電機(jī)功率/r/n160Kw/r/n11/r/n循環(huán)水量/r/n15T/h/r/n12/r/n齒輪油泵壓力/r/n0.2-0.35MPa(表壓)/r/n13/r/n耗油量/r/n70-120g/h/r/n14/r/n冷卻水進(jìn)水溫度/r/n<30/r/n℃/r/n15/r/n氣缸潤滑方式/r/n傳動(dòng)機(jī)構(gòu)齒輪油泵循環(huán)潤滑,氣缸柱塞油泵潤滑/r/n4/r/n.4.2/r/n城市市天然氣管道的天然氣硫含量已經(jīng)控制在國家標(biāo)準(zhǔn)要求的范圍之內(nèi),不需要脫硫處理,CNG加氣站的凈化系統(tǒng)主要是考慮脫水。天然氣的脫水分為低壓脫水和高壓脫水,低壓脫水是在壓縮機(jī)前置干燥器,使干燥的氣體進(jìn)入壓縮機(jī),保護(hù)壓縮機(jī)不受損害。高壓脫水是在壓縮機(jī)后置干燥器,雖然壓縮機(jī)氣缸因進(jìn)入的氣體未脫水而可能受到損害,但是使得供應(yīng)的商品氣更為干燥,更好的保護(hù)了CNG車輛的發(fā)動(dòng)機(jī),維護(hù)了消費(fèi)者的利益。本工程擬采用在壓縮機(jī)后置的高壓脫水裝置(即后處理系統(tǒng)),后處理系統(tǒng)主要為高壓微熱再生干燥器,對(duì)壓縮后的天然氣進(jìn)行干燥和凈化處理,系統(tǒng)裝置含分離器、過濾器、除油器、冷卻器、加熱器、減壓裝置等部件,裝置為雙塔布置。干燥器的主要技術(shù)參數(shù)見表:/r/n干燥器主要技術(shù)參數(shù)表/r/n序號(hào)/r/n項(xiàng)目/r/n技術(shù)參數(shù)/r/n備注/r/n1/r/n工作壓力/r/n25Mpa/r/n
/r/n2/r/n處理氣量/r/n1500Nm/r/n3/r/n/h/r/n
/r/n3/r/n進(jìn)氣溫度/r/n≤/r/n40/r/n℃/r/n
/r/n4/r/n含塵粒徑/r/n<10/r/nμ/r/nm/r/n
/r/n5/r/n含塵量/r/n<5㎎/Nm/r/n3/r/n
/r/n6/r/n工作周期/r/n10h/r/n
/r/n7/r/n再生氣壓力/r/n△/r/nP=0.1-0.2Mpa/r/n
/r/n8/r/n再生氣月耗量/r/n20-30Nm/r/n3/r/n/h/r/n
/r/n9/r/n總功率/r/n12KW/r/n
/r/n4/r/n.4.3/r/nCNG加氣站儲(chǔ)氣設(shè)施主要有儲(chǔ)氣瓶組、儲(chǔ)氣罐和地下儲(chǔ)氣井等。地下儲(chǔ)氣井是區(qū)別于儲(chǔ)氣瓶組和儲(chǔ)氣罐儲(chǔ)氣的一種較先進(jìn)的儲(chǔ)氣方式。井式儲(chǔ)氣裝置采用石油鉆井技術(shù),其技術(shù)符SY/T6535-2002行業(yè)標(biāo)準(zhǔn)的儲(chǔ)氣井專用套管扣連接接入地下,并用耐高壓的專用密封脂進(jìn)行密封,實(shí)行全井段水泥封固成形。井式儲(chǔ)氣相對(duì)于儲(chǔ)氣瓶組和儲(chǔ)氣罐等儲(chǔ)氣設(shè)施具有以下優(yōu)點(diǎn):/r/n(1)井式儲(chǔ)氣裝置安全性能好/r/n井式儲(chǔ)氣裝置額定工作壓力為25MPa,套管具有足夠的強(qiáng)度和抗疲勞性且深埋于地下,與地面金屬容器裝置比較遠(yuǎn),不受環(huán)境溫度變化影響,不受大氣環(huán)境污染,可最大限度地避免惡性事故的發(fā)生,即使萬一發(fā)生事故時(shí),所造成的損失遠(yuǎn)比地面金屬容器裝置小。/r/n(2)占地少、省空間、縮短了防火間距/r/n井式儲(chǔ)氣裝置由于深埋于地下,節(jié)省了占地面積,節(jié)省了空間,縮短了防火間距,節(jié)約了土地,提高站內(nèi)、站外環(huán)境安全等級(jí)。/r/n(3)使用壽命長/r/n根據(jù)SY/T6535-2002《高壓氣地下儲(chǔ)井》的規(guī)定,儲(chǔ)氣井的使用壽命為25年,根據(jù)我國《壓力容器安全技術(shù)監(jiān)察規(guī)程》,地面金屬壓力容器儲(chǔ)氣瓶的使用壽命為15年。/r/n井式儲(chǔ)氣裝置無論從社會(huì)、經(jīng)濟(jì)效益或安全角度綜合分析是最佳的儲(chǔ)氣方式,故本報(bào)告予以選擇。地下儲(chǔ)氣井主要技術(shù)參數(shù)見下表:/r/n地下儲(chǔ)氣井主要技術(shù)參數(shù)表/r/n序號(hào)/r/n項(xiàng)目/r/n技術(shù)參數(shù)/r/n備注/r/n1/r/n總儲(chǔ)氣量/r/n3000Nm/r/n3/r/n
/r/n2/r/n工作壓力/r/n25MPa/r/n
/r/n3/r/n強(qiáng)度及水壓試驗(yàn)/r/n37.5MPa/r/n
/r/n4/r/n儲(chǔ)氣井井口數(shù)/r/n4口/r/n
/r/n5/r/n單井井深/r/n150m/r/n
/r/n6/r/n單井儲(chǔ)氣量/r/n750Nm/r/n3/r/n
/r/n7/r/n單井水容積/r/n3m/r/n3/r/n
/r/n8/r/n井管規(guī)格/r/n直徑177.8mm/r/n×/r/n壁厚10.36mm/r/n
/r/n9/r/n進(jìn)管疲勞循環(huán)次數(shù)/r/n不小于2.5/r/n×/r/n10/r/n4/r/n次/r/n
/r/n10/r/n井斜程度/r/n最大井斜/r/n≤/r/n1.5/r/n°/r/n
/r/n11/r/n井與井間距/r/n1.5m/r/n
/r/n12/r/n井口離地高度/r/n0.3m/r/n
/r/n13/r/n連接方式/r/n單進(jìn)出、雙閥雙保險(xiǎn)、全螺紋連接/r/n
/r/n4/r/n.4.4/r/n加氣機(jī)主要采用國產(chǎn)加氣機(jī),主要技術(shù)參數(shù)如下表:/r/n/r/nCNG加氣機(jī)主要技術(shù)參數(shù)表/r/n序號(hào)/r/n項(xiàng)目/r/n技術(shù)參數(shù)/r/n備注/r/n1/r/n數(shù)量/r/n4臺(tái)/r/n
/r/n2/r/n額定工作壓力/r/n20MPa/r/n
/r/n3/r/n最大工作壓力/r/n25MPa/r/n
/r/n4/r/n設(shè)計(jì)壓力/r/n27.5MPa/r/n
/r/n5/r/n耐壓強(qiáng)度/r/n37.5MPa/r/n
/r/n6/r/n流量范圍/r/n1-30m/r/n3/r/n/min/r/n
/r/n7/r/n計(jì)量精度/r/n±/r/n0.5%/r/n
/r/n8/r/n環(huán)境溫度/r/n-45/r/n℃/r/n~+50/r/n℃/r/n
/r/n9/r/n單次計(jì)量范圍/r/n0~9999.99m/r/n3/r/n或元/r/n
/r/n10/r/n累計(jì)計(jì)量范圍/r/n0~999999.99m/r/n3/r/n或元/r/n
/r/n11/r/n單價(jià)預(yù)制范圍/r/n0.01~99.99元/m/r/n3/r/n
/r/n12/r/n密度預(yù)制范圍/r/n0.0001~0.9999/r/n
/r/n13/r/n讀數(shù)最小分度值/r/n0.01m/r/n3/r/n;0.01元/r/n
/r/n14/r/n電源/r/n220V/r/n±/r/n15%50H/r/nZ/r/n±/r/n1HZ/r/n
/r/n15/r/n功率/r/n<200W/r/n
/r/n16/r/n主管線/r/nΦ/r/n10X2/r/n
/r/n17/r/n計(jì)量方式/r/n自動(dòng)計(jì)量帶夜光顯示/r/n
/r/n18/r/n防爆等級(jí)/r/nExdemib/r/nⅡ/r/nAT4/r/n
/r/n19/r/n質(zhì)量流量計(jì)/r/n進(jìn)口產(chǎn)品并帶有溫度傳感器/r/n進(jìn)行補(bǔ)償/r/n
/r/n
/r/n4/r/n.4.5/r/n(1)充氣程序控制柜的工作原理/r/n充氣程序控制柜是專門為CNG加氣站設(shè)計(jì)的充氣裝置,其工作原理為將壓縮后的氣體按壓力大小次序自動(dòng)分配至每種獨(dú)立的儲(chǔ)氣設(shè)施,無論儲(chǔ)氣設(shè)施壓力如何變化,均能實(shí)現(xiàn)自動(dòng)充氣。充氣從設(shè)定壓力最低的高壓組壓力順序閥開始,由低到高依次向儲(chǔ)氣設(shè)施注入氣體,使每種儲(chǔ)氣設(shè)施壓力一致,直到達(dá)到每種儲(chǔ)氣設(shè)施的額定壓力,并可在CNG的使用過程中隨時(shí)向壓力低的儲(chǔ)氣設(shè)施補(bǔ)充氣體。/r/n(2)充氣程序控制柜主要技術(shù)參數(shù)如下表/r/n充氣程序控制柜技術(shù)參數(shù)表/r/n序號(hào)/r/n項(xiàng)目/r/n技術(shù)參數(shù)/r/n備注/r/n1/r/n壓力表更換/r/n不停機(jī)拆換/r/n
/r/n2/r/n進(jìn)/出氣口/r/n一進(jìn)三出/r/n
/r/n3/r/n工作壓力/r/n25MPa/r/n
/r/n4/r/n工作溫度/r/n-40/r/n℃/r/n~+60/r/n℃/r/n
/r/n5/r/n設(shè)計(jì)壓力/r/n27.5MPa/r/n
/r/n6/r/n進(jìn)出口連接形式/r/n卡套式/r/n
/r/n
/r/n4/r/n.4.6/r/n本工程在壓縮機(jī)組前設(shè)置緩沖罐1臺(tái),V=2m/r/n3/r/n(水容積),P/r/ng/r/n=0.8MPa,主要目的是保證進(jìn)氣壓力穩(wěn)定并去除氣體中雜質(zhì);本工程設(shè)置廢氣收集罐1臺(tái),V=2m/r/n3/r/n(水容積),P/r/ng/r/n=0.8MPa,主要用于收集壓縮機(jī)及干燥器排污所排出的天然氣。緩沖罐和廢氣收集罐為第二類壓力容器。/r/n4/r/n.4.7/r/n本設(shè)計(jì)冷卻水循環(huán)系統(tǒng)主要包括一臺(tái)冷卻塔和兩臺(tái)供水水泵。/r/n(1)冷卻塔/r/n本設(shè)計(jì)選用一臺(tái)60噸低噪聲逆流式玻璃鋼冷卻塔,技術(shù)參數(shù)如下:/r/n逆流式玻璃鋼冷卻塔技術(shù)參數(shù)/r/n名稱/r/n冷卻塔/r/n冷卻水量/r/n60t(28/r/n℃/r/n時(shí),/r/n△/r/nt=5/r/n℃/r/n)/r/n熱水溫度/r/n37/r/n℃/r/n冷水溫度/r/n30/r/n℃/r/n進(jìn)水壓力/r/n30KPa/r/n附風(fēng)機(jī)電動(dòng)機(jī)功率/r/n2.5Kw/r/n(2)供水水泵/r/n本設(shè)計(jì)供水水泵選用離心泵2臺(tái),其技術(shù)參數(shù)如下:/r/n名稱/r/n供水水泵/r/n供水量/r/n90m/r/n3/r/n/h/r/n揚(yáng)程/r/n28m/r/n轉(zhuǎn)速/r/nn=1450R.P.M/r/n附風(fēng)機(jī)電動(dòng)機(jī)功率/r/n11Kw/r/n4/r/n.5CNG加氣站管道及管件選擇/r/n4/r/n.5.1/r/n4/r/n.5.2/r/n4/r/n.5.3/r/n站內(nèi)的管道埋地敷設(shè),其管頂距地面1.0米,室內(nèi)管道采用管溝敷設(shè),管溝內(nèi)用干沙填實(shí)。/r/n4/r/n.5.4/r/n埋地管道防腐設(shè)計(jì)采用特加強(qiáng)級(jí)防腐,執(zhí)行國家標(biāo)準(zhǔn)SY0007《鋼質(zhì)管道及儲(chǔ)罐腐蝕控制工程設(shè)計(jì)規(guī)范》,不銹鋼管不作防腐。/r/n4/r/n.6計(jì)量裝置選擇/r/n(1)流量計(jì)選擇渦輪流量計(jì)(帶溫度和壓力補(bǔ)償);/r/n(2)流量計(jì)前設(shè)過濾器一臺(tái),過濾微小雜質(zhì)并保證渦輪流量計(jì)的精度。/r/n5/r/n建筑設(shè)計(jì)/r/n5/r/n.1遵循的主要規(guī)范:/r/n《汽車加油加氣站設(shè)計(jì)與施工規(guī)范》GB50156-2002(2006年版)/r/n《建筑設(shè)計(jì)防火規(guī)范》GBJ16-87(2001年)/r/n《公共建筑節(jié)能設(shè)計(jì)標(biāo)準(zhǔn)》GB50189-2005/r/n5/r/n.2建筑設(shè)計(jì)的安全要求/r/n①/r/n加氣站內(nèi)的所有建筑物防火等級(jí)為二級(jí),加氣區(qū)罩棚為鋼網(wǎng)架結(jié)構(gòu),耐火極限為0.25h,罩棚采用非燃燒材料。/r/n②/r/n加氣站爆炸危險(xiǎn)區(qū)域內(nèi)所有建筑物的門窗向外開啟。/r/n③/r/n站房為磚混結(jié)構(gòu)。/r/n④/r/n長安區(qū)地震裂度為7度,站區(qū)爆炸危險(xiǎn)區(qū)域內(nèi)的建(構(gòu))筑物如加氣罩棚、站房、廠房及工藝設(shè)備基礎(chǔ)抗震設(shè)計(jì)按7度設(shè)防。/r/n5/r/n.3建筑設(shè)計(jì)的美觀要求/r/n本著簡單、大方、美觀的原則,建筑物在滿足使用功能的前提下要注意美觀,造行要新穎,盡量與周圍城市建筑物協(xié)調(diào),力爭成為城市一個(gè)新的亮點(diǎn)。/r/n5/r/n./r/n4建筑物的節(jié)能設(shè)計(jì)/r/n①/r/n建筑物墻體采用240厚承重空心磚,外墻內(nèi)粉40厚SAC符合保溫砂漿。/r/n/r/n②/r/n建筑物屋面保溫采用90厚憎水膨脹珍珠巖板保溫,導(dǎo)熱系數(shù)/r/n≤/r/n0.070W/m/r/n·/r/nK。/r/n/r/n③/r/n外窗選用白色塑鋼窗,5厚雙層中空玻璃。/r/n/r/n④/r/n在進(jìn)行總平面布置及建筑設(shè)計(jì)時(shí),充分考慮自然得熱。/r/n5/r/n.5/r/n
/r/n建筑物一覽表/r/n/r/n名稱/r/n防火等級(jí)/r/n層數(shù)/r/n層高/r/n面積m/r/n2/r/n用途/r/n備注/r/n加氣島/r/n二/r/n
/r/n0.2/r/n13/r/n安置加氣機(jī)/r/n
/r/n加氣島罩棚/r/n二/r/n一/r/n5.0/r/n120/r/n加氣/r/n
/r/n站房/r/n二/r/n一/r/n3.3/r/n92/r/n營業(yè)、辦公/r/n
/r/n裝置區(qū)廠房/r/n二/r/n一/r/n5.0/r/n200/r/n安置設(shè)備/r/n
/r/n道路、地坪/r/n
/r/n
/r/n
/r/n1103/r/n
/r/n
/r/n圍墻/r/n非燃材料實(shí)體墻/r/n
/r/n
/r/n122延長米/r/n圍墻/r/n
/r/n
/r/n6/r/n采暖與通風(fēng)/r/n6/r/n.1采暖/r/n本站不考慮采暖。/r/n6/r/n.2通風(fēng)/r/n6/r/n.2.1/r/n6/r/n.2.2/r/n/r/n6/r/n.2.3/r/n7/r/n消防系統(tǒng)設(shè)計(jì)/r/n7/r/n.1應(yīng)遵循的主要設(shè)計(jì)規(guī)范/r/n(1)《汽車加油加氣站設(shè)計(jì)與施工規(guī)范》GB50156-2002(2006年版)/r/n(2)《建筑設(shè)計(jì)防火規(guī)范》GBJ16-87(2001年)/r/n(3)《城鎮(zhèn)燃?xì)庠O(shè)計(jì)規(guī)范》GB50028-93(2002年版)/r/n(4)《建筑滅火器配置設(shè)計(jì)規(guī)范》GB50140-2005/r/n7/r/n.2消防系統(tǒng)設(shè)計(jì)概述/r/n7/r/n.2.1/r/nCNG加氣站由于工作介質(zhì)是甲烷,屬甲類可燃?xì)怏w,泄漏后與空氣混合后濃度在5%~6%范圍內(nèi)遇明火即會(huì)發(fā)生燃燒或爆炸,站內(nèi)場(chǎng)所有氣體1區(qū)和2區(qū)爆炸危險(xiǎn)場(chǎng)所;站內(nèi)工藝設(shè)備如儲(chǔ)氣井屬第三類壓力容器;緩沖罐屬第二類壓力容器,工藝管道多為GC1類壓力管道;一旦發(fā)生事故,可能會(huì)對(duì)人民的生命和財(cái)產(chǎn)造成巨大損失。/r/n工作介質(zhì)的易燃易爆特性、設(shè)備管道的高壓危險(xiǎn)特性、站址周邊環(huán)境的重要性是消防系統(tǒng)設(shè)計(jì)應(yīng)考慮的關(guān)鍵因素。/r/n7/r/n.2.2/r/n工程設(shè)計(jì)的合理性、安全性,是消防系統(tǒng)安全的基礎(chǔ),規(guī)范選址、規(guī)范布置、規(guī)范設(shè)計(jì)是本工程設(shè)計(jì)的原則。/r/n7/r/n.3消防系統(tǒng)設(shè)計(jì)的安全措施/r/n7/r/n.3.1/r/n合理選址:滿足規(guī)范GB50156-2002及GB50028-93規(guī)定的天然氣工藝設(shè)施與站外建筑物防火距離,此部分設(shè)計(jì)見第/r/n二/r/n章《站址選擇》第/r/n2.2/r/n7/r/n.3.2/r/n合理布置:滿足規(guī)范GB50156-2002及GB50028-93所規(guī)定的站內(nèi)設(shè)施之間的防火距離,此部分設(shè)計(jì)見/r/n第三/r/n章《站內(nèi)總平面布置》第/r/n3.5/r/n7/r/n.3.3/r/n7/r/n.3.4/r/n7/r/n.3.5/r/n7/r/n.4滅火器材配置/r/n7/r/n.4.1/r/n/r/n/r/n7/r/n.4.2/r/n/r/n/r/n7/r/n.4.3/r/n/r/n/r/n7/r/n.4.4/r/n/r/n/r/n7/r/n.4.5/r/n/r/n/r/n7/r/n.4.6/r/n/r/n/r/n7/r/n.4.7/r/n/r/n/r/n
/r/n建筑物名稱/r/n干粉型(碳酸氫鈉)/r/n二氧化碳/r/n備注/r/n4㎏/r/n(手提)/r/n8㎏/r/n(推車)/r/n35㎏/r/n(推車)/r/n3㎏/r/n(手提)/r/n
/r/n加氣島/r/n
/r/n4/r/n
/r/n
/r/n
/r/n站房/r/n2/r/n2/r/n
/r/n
/r/n
/r/n控制室/r/n
/r/n
/r/n
/r/n2/r/n
/r/n裝置區(qū)/r/n
/r/n4/r/n1/r/n
/r/n
/r/n儲(chǔ)氣區(qū)/r/n
/r/n2/r/n1/r/n
/r/n
/r/n廢油池/r/n
/r/n2/r/n
/r/n
/r/n
/r/n箱式變電站/r/n
/r/n
/r/n
/r/n2/r/n
/r/n合計(jì)/r/n2/r/n14/r/n2/r/n4/r/n
/r/n注:詳見圖《滅火器材配置平面圖》 /r/n7/r/n.5可燃?xì)怏w檢測(cè)器/r/n7/r/n.5.1/r/n裝置區(qū)設(shè)置可燃?xì)怏w檢測(cè)器/r/n2/r/n臺(tái)/r/n7/r/n.5.2/r/n加氣區(qū)設(shè)置可燃?xì)怏w檢測(cè)器/r/n2/r/n臺(tái)/r/n7/r/n.5.3/r/n7/r/n.6消防安全機(jī)構(gòu)、消防管理制度和事故搶險(xiǎn)預(yù)案/r/n7/r/n.6.1/r/n本工程在投運(yùn)前,建設(shè)單位應(yīng)成立專門的消防安全領(lǐng)導(dǎo)小組,企業(yè)法人或經(jīng)理應(yīng)兼任領(lǐng)導(dǎo)小組組長,領(lǐng)導(dǎo)小組中應(yīng)有專職消防安全管理人員。/r/n7/r/n.6.2/r/n建設(shè)單位在工程投運(yùn)時(shí)除應(yīng)制定安全生產(chǎn)的各項(xiàng)操作、管理規(guī)章制度外,還應(yīng)制定消防管理制度,內(nèi)容包括消防機(jī)構(gòu)人員的分工、崗位責(zé)任制、消防器材的管理、人員培訓(xùn)、事故預(yù)案演練等。/r/n7/r/n.6.3/r/n/r/n本工程可能產(chǎn)生的重大事故為容器管道、加氣槍等泄露后產(chǎn)生的火災(zāi)爆炸事故(即化學(xué)爆炸),也有可能產(chǎn)生高壓容器、高壓管道爆炸事故(即物理爆炸),兩種情況都有可能導(dǎo)致易燃易爆氣體大量泄漏引發(fā)重大事故,從而造成更多的人員傷亡。本工程在投運(yùn)前建設(shè)單位應(yīng)在消防部門的指導(dǎo)下,制定事故搶險(xiǎn)預(yù)案,對(duì)可能產(chǎn)生事故的要害部位所引發(fā)的事故種類制定相應(yīng)的預(yù)防搶險(xiǎn)預(yù)案。預(yù)案中對(duì)崗位的人員分工、消防器材管理、預(yù)防措施、搶險(xiǎn)路徑、搶險(xiǎn)操作步驟、向消防部門報(bào)警、周圍人群疏散等應(yīng)作出具體明確的規(guī)定。并應(yīng)在日常管理中注意演練,確保不發(fā)生事故或在事故發(fā)生時(shí)確保在第一時(shí)間把事故消滅在萌芽狀態(tài),把損失降低到最小程度。/r/n8/r/n電氣設(shè)計(jì)/r/n8/r/n.1供配電系統(tǒng)/r/n8/r/n.1.1/r/n8/r/n.1.2/r/n用電設(shè)備裝接容量/r/n表/r/n
/r/n設(shè)備名稱/r/n臺(tái)數(shù)/r/n單臺(tái)容量(KW)/r/n總?cè)萘?KW)/r/n備注/r/n加油機(jī)/r/n4/r/n1.5/r/n6/r/n壓縮機(jī)/r/n2/r/n主電機(jī)/r/n)/r/n324.58/r/n
/r/n)/r/n)/r/n干燥器/r/n1/r/n12/r/n12/r/n
/r/n售氣機(jī)/r/n4/r/n0.2/r/n0.8/r/n
/r/n照明/r/n
/r/n
/r/n20/r/n
/r/n冷卻系統(tǒng)/r/n1套/r/n
/r/n24.5/r/n
/r/n合計(jì)/r/n
/r/n
/r/n38/r/n7/r/n.88/r/n
/r/n
/r/n8/r/n.1.3/r/n8/r/n.2電纜敷設(shè)/r/n·/r/n本站內(nèi)電力線路采用銅芯交聯(lián)聚乙烯電纜直埋敷設(shè),電纜穿越道路時(shí)穿鋼管保護(hù)。/r/n·/r/n至裝置區(qū)、加氣區(qū)設(shè)備的電纜在混凝土地面下穿鋼管保護(hù)。/r/n·/r/n照明電纜地面下直埋至燈具或開關(guān)時(shí)穿鋼管保護(hù)。/r/n /r/n·/r/n照明導(dǎo)線穿鋼管暗配。/r/n·/r/n電纜不得與天然氣管道同溝敷設(shè)。/r/n8/r/n.3防爆區(qū)域劃分和防爆電氣選擇/r/n8/r/n.3.1/r/n(1)下列部位劃為1區(qū)/r/n·/r/n售氣機(jī)內(nèi)部;/r/n·/r/n壓縮機(jī)、閥門、法蘭或類似附件的房間的內(nèi)部空間劃分為1區(qū)。/r/n(2)下列部位劃為2區(qū)/r/n·/r/n加氣機(jī)中心線半徑4.5m,高度自地面向上至加氣機(jī)頂部以上0.5m/r/n的圓柱形空間;/r/n·/r/n儲(chǔ)氣井4.5m以內(nèi)的空間;/r/n·/r/n壓縮機(jī)閥門、法蘭或類似附件的房間有孔洞或開式墻外,以孔洞邊緣為中心半徑3m以內(nèi)至地面的空間。/r/n8/r/n.3.2/r/n/r/n·/r/n爆炸危險(xiǎn)區(qū)域內(nèi)的電氣設(shè)備選型按照GB50058《爆炸和火災(zāi)危險(xiǎn)環(huán)境電力裝置設(shè)計(jì)規(guī)范》要求,1區(qū)內(nèi)選擇本安型設(shè)備,2區(qū)內(nèi)選擇隔爆型設(shè)備。/r/n8/r/n.4防雷設(shè)計(jì)/r/n8/r/n.4.1/r/n8/r/n.4.2/r/n站內(nèi)建筑及罩棚屋面采用避雷網(wǎng)帶防雷,網(wǎng)格為10/r/n×/r/n10米,網(wǎng)帶為-40/r/n×/r/n8/r/n.4.310KV電源電纜在變壓器高壓側(cè)設(shè)置過電壓保護(hù)器。/r/n8/r/n.4.4/r/n8/r/n.5防靜電設(shè)計(jì)/r/n8/r/n.5.1/r/n8/r/n.5.2/r/n8/r/n.5.3/r/n8/r/n.5.4/r/n9/r/n自控和儀表/r/n9/r/n.1CNG加氣站的控制系統(tǒng)/r/n9/r/n.1.1/r/n9/r/n.1.2/r/n9/r/n.1.3/r/n三級(jí)儲(chǔ)氣系統(tǒng)通過程序控制盤控制,首先給高壓儲(chǔ)氣井充氣,然后是中壓、最后是低壓。/r/n三級(jí)取氣系統(tǒng)通過售氣機(jī)控制,取氣順序與儲(chǔ)氣順序相反。/r/n9/r/n.2CNG加氣站的儀表設(shè)置/r/n9/r/n.2.1/r/n天然氣流量計(jì)安裝于過濾器后,產(chǎn)品選用渦輪式流量計(jì),該流量計(jì)采用溫度壓力補(bǔ)償,計(jì)量準(zhǔn)確。/r/n9/r/n.2.2/r/n干燥器、緩沖罐、壓縮機(jī)組、儲(chǔ)氣井和售氣機(jī)等設(shè)備隨機(jī)設(shè)置有壓力、溫度、流量等傳感器,反映到設(shè)備現(xiàn)場(chǎng)控制盤和遠(yuǎn)傳到控制室。/r/n9/r/n.2.3/r/n現(xiàn)場(chǎng)設(shè)備壓縮機(jī)附帶控制柜,現(xiàn)場(chǎng)設(shè)備的各種工藝參數(shù)運(yùn)傳至此控制柜,柜上安裝二次儀表,柜內(nèi)設(shè)有PLC可編程控制器,對(duì)現(xiàn)場(chǎng)數(shù)據(jù)進(jìn)行顯示,越限報(bào)警開、??刂?。/r/n10/r/n壓力容器、壓力管道設(shè)計(jì)/r/n10/r/n.1概述/r/n本章所述的壓力容器設(shè)計(jì),非容器本體的設(shè)計(jì),一般由容器的制造單位設(shè)計(jì)制造,作為工程設(shè)計(jì)單位實(shí)際上是指容器的設(shè)計(jì)選型。本章所述的壓力管道,不包括設(shè)備本體的管道,這些管道已經(jīng)由設(shè)備制造單位設(shè)計(jì),壓力管道設(shè)計(jì)是指設(shè)備之間的配管設(shè)計(jì)。/r/n10/r/n.2遵循的主要規(guī)范/r/n《城鎮(zhèn)燃?xì)庠O(shè)計(jì)規(guī)范》GB50028-93(2002年版)/r/n《汽車加油加氣站設(shè)計(jì)與施工規(guī)范》GB50156-2002(2006年版)/r/n《壓力容器安全技術(shù)監(jiān)察規(guī)程》質(zhì)技監(jiān)局鍋發(fā)[1999]154號(hào)/r/n《壓力管道安全管理與監(jiān)察規(guī)定》勞部發(fā)[1996]140號(hào)/r/n10/r/n.3壓力容器、壓力管道的設(shè)計(jì)原則/r/nCNG加氣站的工作介質(zhì)具有易燃易爆特性;CNG加氣站的設(shè)計(jì)壓力可能是城市公用設(shè)施中最高的壓力;CNG加氣站一般又處于城市建成區(qū),所以壓力容器、壓力管道的設(shè)計(jì)必須嚴(yán)格遵守國家相關(guān)規(guī)范,注意選型選材,體現(xiàn)以人為本,關(guān)注生命安全的原則。/r/n10/r/n.4儲(chǔ)氣設(shè)施的比較及方案選擇/r/n關(guān)于儲(chǔ)氣設(shè)施的比較選擇已在第/r/n四/r/n章第/r/n4/r/n.4條闡述,采用地下儲(chǔ)氣井主要是考慮到較之地面儲(chǔ)氣設(shè)施更為安全。/r/n10/r/n.5壓力管道的設(shè)計(jì)/r/n壓力管道的設(shè)計(jì)已在第/r/n四/r/n章第/r/n4/r/n.5條中闡述。/r/n10/r/n.6壓力容器、壓力管道的安全保護(hù)/r/n壓力容器、壓力管道的安全保護(hù)已在第/r/n四/r/n章和第/r/n4.3/r/n章中闡述。/r/n10/r/n.7壓力容器、壓力管道的分級(jí)品種及分類/r/n概括上述第11.2條規(guī)范,壓力容器、壓力管道的分級(jí)分類如下表/r/nCNG加氣站壓力容器壓力管道分級(jí)分類表/r/n序號(hào)/r/n容器管道名稱/r/n設(shè)計(jì)壓力(MPa)/r/n容積(m/r/n3/r/n)/r/n數(shù)量/r/n用途/r/n材質(zhì)/r/n級(jí)別、品種、類別/r/n按設(shè)計(jì)壓力分級(jí)/r/n按用途分種類/r/n按適用/r/n范圍分類/r/n
/r/n一、壓力容器/r/n
/r/n
/r/n
/r/n
/r/n
/r/n
/r/n
/r/n
/r/n1/r/n干燥器/r/n1.6/r/n
/r/n一套/r/n脫水/r/n
/r/n中壓/r/n分離壓力容器/r/n二/r/n2/r/n緩沖罐/r/n1.6/r/n2/r/n1臺(tái)/r/n緩沖/r/n
/r/n中壓/r/n分離壓力容器/r/n二/r/n3/r/n廢氣罐/r/n1.6/r/n1/r/n1臺(tái)/r/n收集/r/n
/r/n中壓/r/n分離壓力容器/r/n二/r/n4/r/n儲(chǔ)氣井/r/n27.5/r/n3/r/n4口/r/n儲(chǔ)存/r/n
/r/n高壓/r/n儲(chǔ)存壓力容器/r/n三/r/n
/r/n二、壓力管道/r/n
/r/n管徑/r/n
/r/n
/r/n
/r/n
/r/n
/r/n
/r/n1/r/n壓縮機(jī)前/r/n天然氣管道/r/n1.6/r/n
/r/n
/r/n輸送流體用/r/nGB8163無縫鋼管/r/nGB1/GC2(1)/r/n輸送甲類火災(zāi)危險(xiǎn)介質(zhì)/r/n
/r/n2/r/n壓縮機(jī)后/r/n天然氣管道/r/n25/r/n
/r/n
/r/n輸送流體用/r/nGB/T14976不銹鋼無縫鋼管/r/nGB1/GC1(1)/r/n輸送甲類火災(zāi)危險(xiǎn)介質(zhì)/r/n
/r/n10/r/n.8壓力管道設(shè)計(jì)、安裝、運(yùn)行的安全監(jiān)察/r/n壓力管道的設(shè)計(jì)安裝單位必須具有相應(yīng)的設(shè)計(jì)、安裝資格,設(shè)計(jì)文件需經(jīng)質(zhì)檢部門審查同意,安裝前需辦理告知手續(xù),施工時(shí)應(yīng)接受質(zhì)檢部門的質(zhì)量檢驗(yàn),運(yùn)行時(shí)應(yīng)按規(guī)定年限進(jìn)行定期檢驗(yàn)。/r/n11/r/n勞動(dòng)安全與工業(yè)衛(wèi)生/r/n1/r/n1/r/n.1應(yīng)遵循的勞動(dòng)安全衛(wèi)生規(guī)程和標(biāo)準(zhǔn)/r/n1、《汽車加油加氣站設(shè)計(jì)與施工規(guī)范》GB50156-2002(2006年版)/r/n2、《建筑設(shè)計(jì)防火規(guī)范》GBJ16-87(2001年版)/r/n3、《爆炸和火災(zāi)危險(xiǎn)環(huán)境電力裝置設(shè)計(jì)規(guī)范》GB50058-92/r/n4、《壓力容器安全技術(shù)監(jiān)察規(guī)程》質(zhì)技監(jiān)局鍋發(fā)[1999]154號(hào);/r/n5、/r/n《/r/n壓力管道安全管理與監(jiān)察規(guī)定》勞部發(fā)[1996]140號(hào)/r/n6、《石油化工企業(yè)職業(yè)安全衛(wèi)生設(shè)計(jì)規(guī)范》SH3047-93/r/n7、《職業(yè)性接觸毒物危害程度分級(jí)》GB5044-85/r/n8、《建筑物防雷設(shè)計(jì)規(guī)范》GB50057-94(2000年版)/r/n1/r/n1/r/n.2生產(chǎn)中能產(chǎn)生的職業(yè)危害以及造成危害的因素/r/n1/r/n1/r/nCNG加氣站最高工作壓力高達(dá)25MPa,其主要設(shè)備壓縮機(jī)組、儲(chǔ)氣井、干燥器等設(shè)備的部分或整體屬高壓容器、高壓管道,由于材質(zhì)、裝配、施工、運(yùn)行等方面的原因有可能產(chǎn)生爆裂事故,危及到職工人身安全。/r/n1/r/n1/r/n天然氣的主要成份是甲烷,甲烷含量高達(dá)90%以上,還有少量的乙烷、丙烷等烷烴類,以及微量的硫化氫氣體等。天然氣是一種易燃易爆的氣體,與空氣混合后,濃度在5%~16%范圍內(nèi),遇火源即會(huì)發(fā)生爆炸和燃燒;與空氣混合后,只要溫度達(dá)到650/r/n℃/r/n左右,會(huì)產(chǎn)生自燃;組成天然氣的氣態(tài)烴本身是無毒的,但是如果天然氣中含有硫化氫時(shí)就會(huì)毒害人體;當(dāng)天然氣大量泄漏到空氣或室內(nèi)達(dá)到一定濃度時(shí),造成空氣中含氧量減少,嚴(yán)重時(shí)可使人窒息死亡;另外天然氣燃燒不充分時(shí),生成的一氧化碳對(duì)人體也有毒害作用。/r/n1/r/n1/r/nCNG加氣站內(nèi)電氣設(shè)備有箱變、設(shè)備電機(jī)及電纜等,有可能產(chǎn)生漏電現(xiàn)象,造成操作工觸電事故。/r/n由于氣體在管道中高速流動(dòng),有可能在設(shè)備、管道、加氣機(jī)等處產(chǎn)生靜電,靜電是一種無源電荷,當(dāng)人體觸摸時(shí)通過人放電,靜電不可能造成生命危險(xiǎn),但有可能引發(fā)二次事故,另外靜電火花也有可能引燃泄漏的可燃?xì)怏w。/r/n12.2.4/r/n雷電事故/r/nCNG加氣站是易燃易爆場(chǎng)所,其加氣區(qū)罩棚、裝置區(qū)廠房等較突出的部分,夏季有可能遭到雷擊,當(dāng)人體靠近或觸摸設(shè)備時(shí)有可能使人體遭到雷擊,另外雷擊也可能點(diǎn)燃引爆可燃?xì)怏w。/r/n1/r/n1/r/n.3勞動(dòng)安全和工業(yè)衛(wèi)生措施/r/n1/r/n1/r/n1/r/n1/r/nCNG加氣站是甲類火災(zāi)危險(xiǎn)場(chǎng)所,甲烷的比重比空氣輕,容易擴(kuò)散,爆炸范圍較寬,在工程設(shè)計(jì)中,設(shè)置大型消防車回車場(chǎng)地,設(shè)置滅火器材;在實(shí)際運(yùn)行中,要制定消防預(yù)案,日常注意演練,把事故消滅在萌芽狀態(tài),滅火器材要定期檢驗(yàn),更換填料,確保處于完好狀態(tài)。/r/n11/r/n.3.3/r/n壓力容器、壓力管道系統(tǒng)設(shè)計(jì)安全保護(hù)裝置,安裝安全閥、壓力表及壓力超限自動(dòng)報(bào)警系統(tǒng),在壓力超限時(shí)安全閥自動(dòng)放散,同時(shí)報(bào)警;設(shè)置分?jǐn)嚅y門、緊急切斷閥,緊急情況下切斷氣源;運(yùn)行中要按規(guī)章操作,壓力容器、壓力管道要定期檢驗(yàn)。/r/n1/r/n1/r/n容易產(chǎn)生天然氣泄漏的場(chǎng)所,安裝可燃?xì)怏w報(bào)警器。/r/n1/r/n1/r/n本站所有電氣設(shè)備,設(shè)有保護(hù)接地,以防止人體觸電,加氣區(qū)罩棚、裝置區(qū)廠房均設(shè)有防雷接地系統(tǒng),所有設(shè)備和管道設(shè)有靜電接地系統(tǒng)。/r/n1/r/n2/r/n環(huán)境保護(hù)/r/n1/r/n2/r/n.1設(shè)計(jì)依據(jù)及規(guī)范/r/n(1)《中華人民共和國環(huán)境保護(hù)法》/r/n(2)《建設(shè)項(xiàng)目環(huán)境保護(hù)設(shè)計(jì)規(guī)定》(1987)國環(huán)字第002號(hào)/r/n(3)《大氣污染物綜合排放標(biāo)準(zhǔn)》GB16297-1996/r/n(4)《環(huán)境空氣質(zhì)量標(biāo)準(zhǔn)》GB3095-1996/r/nⅡ/r/n級(jí)標(biāo)準(zhǔn)/r/n(5)《地面水環(huán)境質(zhì)量標(biāo)準(zhǔn)》GB3838-88/r/nⅢ/r/n類標(biāo)準(zhǔn)/r/n(6)《城市區(qū)域環(huán)境噪聲標(biāo)準(zhǔn)》GB3096-93/r/nⅡ/r/n類標(biāo)準(zhǔn)/r/n(7)《工業(yè)企業(yè)噪聲控制設(shè)計(jì)規(guī)范》GBJ87-85/r/n1/r/n2/r/n.2本項(xiàng)目環(huán)保意義/r/n本站是一項(xiàng)環(huán)保工程,建成后可日供壓縮天然氣20000Nm/r/n3/r/n,對(duì)減少市內(nèi)機(jī)動(dòng)車輛尾氣污染,提高市內(nèi)大氣質(zhì)量起到一定的推進(jìn)作用。/r/n1/r/n2/r/n.3工程投產(chǎn)運(yùn)行后的污染源概況/r/n本站供應(yīng)的天然氣為經(jīng)過凈化、脫硫、脫水和脫除輕烴等處理后的合格車用天然氣。/r/n本工程正常時(shí)介質(zhì)在密閉的系統(tǒng)內(nèi)運(yùn)行,不產(chǎn)生任何污染物,管道事故狀態(tài)時(shí)可能泄漏天然氣。/r/n本工程無大量廢氣、廢水、廢渣等現(xiàn)象。/r/n1/r/n2/r/n.4本項(xiàng)目污染源分析/r/n1/r/n2/r/n當(dāng)管道壓力超高或在進(jìn)行維修時(shí),將通過放散管排出少量天然氣。輸氣管道發(fā)生泄漏時(shí),將有部分天然氣排出。/r/n1/r/n2/r/n天然氣的輸配系統(tǒng)是一個(gè)密閉系統(tǒng),不存在再加工,除了排放少量生活污水、設(shè)備、場(chǎng)地沖洗水外,工藝生產(chǎn)的干燥器脫水裝置可能分離出極少量污水(每天約0.4㎏)除此再無其它污水排放。/r/n1/r/n2/r/n1/r/n2/r/n生產(chǎn)運(yùn)行中,站內(nèi)的天然氣計(jì)量過程中因節(jié)流或流速改變會(huì)產(chǎn)生一定的噪聲,其聲壓級(jí)約80dB(A)。/r/n1/r/n2/r/n.5設(shè)計(jì)采取的環(huán)境保護(hù)措施/r/n1/r/n2/r/n1/r/n2/r/n1/r/n2/r/n12/r/n.5.4/r/n站內(nèi)污水主要為少量的生活污水、場(chǎng)地及設(shè)備沖洗水,生活污水經(jīng)處理后運(yùn)出站外。壓縮機(jī)及干燥器排出的少量油污及廢水由廢油池收集并定期運(yùn)走,場(chǎng)地及設(shè)備沖洗水經(jīng)隔離沉淀后排入市政污水管。/r/n1/r/n2/r/n選用適宜的計(jì)量設(shè)備盡量減少站場(chǎng)工藝管道的彎頭、三通等管件,降低站內(nèi)的噪聲,使噪聲排放達(dá)到國家允許標(biāo)準(zhǔn)。/r/n13/r/n節(jié)能評(píng)價(jià)/r/n1/r/n3/r/n.1本項(xiàng)目主要耗能的部位及能源種類/r/n本項(xiàng)目主要能耗指標(biāo)、定額選用原則均以國家已頒布的標(biāo)準(zhǔn)和規(guī)范為依據(jù)。/r/n該站所耗能源主要是水、電,全年能源需要量如下表:/r/n加氣站耗能表/r/n序號(hào)/r/n種類/r/n年消耗量/r/n備注/r/n1/r/n電/r/n10.23萬Kwh/a/r/n2/r/n水/r/n720t/a/r/n1/r/n3/r/n.2節(jié)能措施/r/n1/r/n3/r/n1/r/n3/r/n1/r/n3/r/n1/r/n3/r/n.3節(jié)能評(píng)價(jià)/r/n本工程本身就是一項(xiàng)節(jié)能工程,通過改變汽車燃料,節(jié)約了石油資源,符合我國能源結(jié)構(gòu)調(diào)整的政策,降低了車輛運(yùn)行成本,站內(nèi)工藝設(shè)施的設(shè)計(jì)、運(yùn)行采取先進(jìn)合理的技術(shù),節(jié)約了電能,節(jié)能效益整體評(píng)價(jià)是可行的。/r/n1/r/n4/r/n
溫馨提示
- 1. 本站所有資源如無特殊說明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請(qǐng)下載最新的WinRAR軟件解壓。
- 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請(qǐng)聯(lián)系上傳者。文件的所有權(quán)益歸上傳用戶所有。
- 3. 本站RAR壓縮包中若帶圖紙,網(wǎng)頁內(nèi)容里面會(huì)有圖紙預(yù)覽,若沒有圖紙預(yù)覽就沒有圖紙。
- 4. 未經(jīng)權(quán)益所有人同意不得將文件中的內(nèi)容挪作商業(yè)或盈利用途。
- 5. 人人文庫網(wǎng)僅提供信息存儲(chǔ)空間,僅對(duì)用戶上傳內(nèi)容的表現(xiàn)方式做保護(hù)處理,對(duì)用戶上傳分享的文檔內(nèi)容本身不做任何修改或編輯,并不能對(duì)任何下載內(nèi)容負(fù)責(zé)。
- 6. 下載文件中如有侵權(quán)或不適當(dāng)內(nèi)容,請(qǐng)與我們聯(lián)系,我們立即糾正。
- 7. 本站不保證下載資源的準(zhǔn)確性、安全性和完整性, 同時(shí)也不承擔(dān)用戶因使用這些下載資源對(duì)自己和他人造成任何形式的傷害或損失。
最新文檔
- 籃球618活動(dòng)策劃方案(3篇)
- 電路隱蔽施工方案(3篇)
- 粉塵定期清理安全管理制度(3篇)
- 醫(yī)院網(wǎng)評(píng)員管理制度(3篇)
- 車間標(biāo)識(shí)卡管理制度內(nèi)容(3篇)
- 2026國家統(tǒng)計(jì)局黔南調(diào)查隊(duì)招聘編外聘用人員1人(貴州)備考考試試題及答案解析
- 2026江蘇南京大學(xué)生物醫(yī)學(xué)工程學(xué)院準(zhǔn)聘長聘崗位(事業(yè)編制)招聘備考考試題庫及答案解析
- 2026年1月江蘇揚(yáng)州市衛(wèi)生健康系統(tǒng)事業(yè)單位招聘專業(yè)技術(shù)人員54人參考考試題庫及答案解析
- 2026重慶飛駛特人力資源管理有限公司派往重慶市運(yùn)動(dòng)技術(shù)學(xué)院專職體能教練員招聘備考考試試題及答案解析
- 護(hù)理案例分享:感染控制與預(yù)防的重要性
- 百人公司年會(huì)策劃方案
- 青少年法律知識(shí)競賽試題及答案
- 鏈?zhǔn)捷斔蜋C(jī)傳動(dòng)系統(tǒng)設(shè)計(jì)
- 加班工時(shí)管控改善方案
- 2025分布式數(shù)據(jù)庫 OceanBase 架構(gòu)演進(jìn)與業(yè)務(wù)場(chǎng)景實(shí)踐
- 2025年軍工企業(yè)招聘考試面試流程與注意事項(xiàng)詳解
- 《昆蟲記》中的昆蟲圖片
- 鐵路施工安全檢查日志范本
- 五層外架施工方案
- 供應(yīng)鏈中斷應(yīng)急預(yù)案(商品斷供、物流中斷)
- 山東省青島市李滄、平度、西海岸、膠州2026屆九年級(jí)數(shù)學(xué)第一學(xué)期期末綜合測(cè)試試題含解析
評(píng)論
0/150
提交評(píng)論