版權(quán)說明:本文檔由用戶提供并上傳,收益歸屬內(nèi)容提供方,若內(nèi)容存在侵權(quán),請(qǐng)進(jìn)行舉報(bào)或認(rèn)領(lǐng)
文檔簡(jiǎn)介
經(jīng)典word整理文檔,僅參考,雙擊此處可刪除頁眉頁腳。本資料屬于網(wǎng)絡(luò)整理,如有侵權(quán),請(qǐng)聯(lián)系刪除,謝謝!配電網(wǎng)巡視規(guī)程******供電公司配電運(yùn)檢2014年11月0目錄前言·····························31范圍·····························42規(guī)范性引用文件························43術(shù)語和定義·························44總則·····························55配電網(wǎng)巡視檢查和防護(hù)·····················65.1巡視檢查的一般要求·····················65.2防護(hù)的一般要求·······················85.3架空線路的巡視·······················85.4架空線路的防護(hù)·······················105.5電纜線路的巡視·······················115.6電纜線路的防護(hù)·······················125.7柱上開關(guān)設(shè)備的巡視·····················125.8開關(guān)柜、環(huán)網(wǎng)柜的巡視····················135.9配電變壓器的巡視·······················135.10站所類建(構(gòu))筑物的巡視··················135.11柱上電容器的巡視······················145.12防雷和接地裝置的巡視····················145.13其它設(shè)備的巡視·······················156缺陷及隱患管理·······················151附錄A架空配電線路污穢分級(jí)標(biāo)準(zhǔn)·················18附錄B線路間及與其它物體之間的距離···············202前言為進(jìn)一步加強(qiáng)配電網(wǎng)運(yùn)行管理工作,提高配電網(wǎng)精益化工作水平,國(guó)家電網(wǎng)公司組織編寫了《配電網(wǎng)運(yùn)行規(guī)程》,旨在通過強(qiáng)化配電網(wǎng)設(shè)備的巡視檢查、開展帶電檢測(cè)和狀態(tài)評(píng)價(jià),實(shí)施配電網(wǎng)狀態(tài)管理?!杜潆娋W(wǎng)運(yùn)行規(guī)程》是國(guó)家電網(wǎng)公司所屬各區(qū)域電網(wǎng)公司、?。▍^(qū)、市)公司進(jìn)行中壓配電網(wǎng)運(yùn)行的指導(dǎo)性文件。本規(guī)程依據(jù)國(guó)家和行業(yè)有關(guān)法律、法規(guī)、規(guī)范、規(guī)程編寫,按照國(guó)網(wǎng)公司對(duì)配電網(wǎng)精益化管理的各項(xiàng)要求,充分考慮各網(wǎng)省公司配電網(wǎng)管理特點(diǎn),認(rèn)真總結(jié)運(yùn)行經(jīng)驗(yàn),并引入了設(shè)備狀態(tài)管理、配電網(wǎng)信息化等先進(jìn)理念。3配電網(wǎng)運(yùn)行規(guī)程1范圍本規(guī)程規(guī)定了中壓(10、20kV)配電網(wǎng)運(yùn)行環(huán)節(jié)所應(yīng)遵守的主要技術(shù)規(guī)范與要求。2規(guī)范性引用文件下列文件中的條款通過本規(guī)程的引用而成為本規(guī)程的條款。凡是注日期的引用文件,其隨后所有的修改單(不包括勘誤的內(nèi)容)或修訂版均不適用于本規(guī)程,然而,鼓勵(lì)根據(jù)本規(guī)程達(dá)成協(xié)議的各方研究是否可使用這些文件的最新版本。凡是不注日期的引用文件,其最新版本適用于本規(guī)程。GB50173電氣裝置安裝工程35kV及以下架空電力線路施工及驗(yàn)收規(guī)范GB50168電氣裝置安裝工程電纜線路施工及驗(yàn)收規(guī)范GB50169電氣裝置安裝工程接地裝置施工及驗(yàn)收規(guī)范GB50150電氣裝置安裝工程電氣設(shè)備交接試驗(yàn)標(biāo)準(zhǔn)GB50217電力工程電纜設(shè)計(jì)規(guī)范DL/T572電力變壓器運(yùn)行規(guī)程DL/T596電力設(shè)備預(yù)防性試驗(yàn)規(guī)程DL/T599城市中低壓電網(wǎng)改造技術(shù)導(dǎo)則DL/T601架空絕緣配電線路設(shè)計(jì)技術(shù)規(guī)程DL/T602架空絕緣配電線路施工及驗(yàn)收規(guī)程DL/T741架空送電線路運(yùn)行規(guī)程DL/T522010kV及以下架空配電線路設(shè)計(jì)技術(shù)規(guī)程SD292架空配電線路及設(shè)備運(yùn)行規(guī)程國(guó)務(wù)院第293號(hào)令電力設(shè)施保護(hù)條例電監(jiān)會(huì)27號(hào)令供電監(jiān)管辦法Q/GDW370城市配電網(wǎng)技術(shù)導(dǎo)則Q/GDW382配電網(wǎng)自動(dòng)化技術(shù)導(dǎo)則Q/GDW512電力電纜線路運(yùn)行規(guī)程國(guó)家電網(wǎng)生〔2008〕269號(hào)《國(guó)家電網(wǎng)公司設(shè)備狀態(tài)檢修管理規(guī)定(試行)》和《國(guó)家電網(wǎng)公司關(guān)于規(guī)范開展?fàn)顟B(tài)檢修工作意見》國(guó)家電網(wǎng)生〔2009〕190號(hào)關(guān)于印發(fā)《國(guó)家電網(wǎng)公司深入開展現(xiàn)場(chǎng)標(biāo)準(zhǔn)化作業(yè)工作指導(dǎo)意見》的通知國(guó)網(wǎng)安監(jiān)〔2009〕664號(hào)《國(guó)家電網(wǎng)公司電力安全工作規(guī)程》國(guó)家電網(wǎng)生〔2010〕637號(hào)《國(guó)家電網(wǎng)公司電纜通道管理規(guī)范》3術(shù)語和定義下列術(shù)語和定義適用于本規(guī)程。3.1電纜分支箱cablebranchbox4完成配電系統(tǒng)中電纜線路的匯集和分接功能,但一般不配置開關(guān),不具備控制測(cè)量等二次輔助配置的專用電氣連接設(shè)備。3.2狀態(tài)condition指對(duì)設(shè)備當(dāng)前各種技術(shù)性能與運(yùn)行環(huán)境綜合評(píng)價(jià)結(jié)果的體現(xiàn)。設(shè)備狀態(tài)分為正常狀態(tài)、注意狀態(tài)、異常狀態(tài)和嚴(yán)重狀態(tài)四種類型。3.3狀態(tài)量criteria指直接或間接表征設(shè)備狀態(tài)的各類信息,如數(shù)據(jù)、聲音、圖像、現(xiàn)象等。3.4例行試驗(yàn)routinetest指定期進(jìn)行的,為獲取設(shè)備狀態(tài)量的各種帶電檢測(cè)和停電試驗(yàn)。3.5診斷性試驗(yàn)diagnostictest指巡視檢查、在線監(jiān)測(cè)、例行試驗(yàn)等發(fā)現(xiàn)設(shè)備狀態(tài)不良,或經(jīng)受了不良工況,或受家族缺陷警示,或連續(xù)運(yùn)行了較長(zhǎng)時(shí)間,為進(jìn)一步評(píng)價(jià)設(shè)備狀態(tài)進(jìn)行的試驗(yàn)。3.6初值initialvalue指能夠代表狀態(tài)量原始值的試驗(yàn)值。初值可以是出廠值、交接試驗(yàn)值、早期試驗(yàn)值、大修后首次試驗(yàn)值等。3.7家族缺陷familydefect指由設(shè)計(jì)、材質(zhì)、工藝共性因素導(dǎo)致的設(shè)備缺陷。4總則4.1家電網(wǎng)公司電力安全工作規(guī)程》的有關(guān)規(guī)定。4.2配電網(wǎng)運(yùn)行單位(以下簡(jiǎn)稱運(yùn)行單位)應(yīng)有明確的設(shè)備運(yùn)行責(zé)任分界點(diǎn),配電網(wǎng)與發(fā)電廠、變電所、中壓用戶的分界點(diǎn)按照《供電營(yíng)業(yè)規(guī)則》及相關(guān)規(guī)定確定。4.3運(yùn)行單位應(yīng)參與配電網(wǎng)的規(guī)劃、設(shè)計(jì)審查、設(shè)備選型與招標(biāo)、施工驗(yàn)收及用戶業(yè)擴(kuò)工程接入方案審查等工作;根據(jù)歷年反事故措施、安全措施的要求和運(yùn)行經(jīng)驗(yàn),提出改進(jìn)建議,力求設(shè)計(jì)、選型、施工與運(yùn)行協(xié)調(diào)一致。4.4運(yùn)行單位應(yīng)建立運(yùn)行崗位責(zé)任制,明確分工,各配電設(shè)備、設(shè)施應(yīng)有專人負(fù)責(zé)。4.5配電網(wǎng)運(yùn)行工作應(yīng)積極推廣應(yīng)用帶電檢測(cè)、在線監(jiān)測(cè)等手段,及時(shí)、動(dòng)態(tài)的了解和掌握各類配網(wǎng)設(shè)備的運(yùn)行狀態(tài),并結(jié)合配電設(shè)備在電網(wǎng)中的重要程度以及不同季節(jié)、環(huán)境特點(diǎn),采用定期與非定期巡視檢查相結(jié)合的方法,確保工作有序、高效。4.6配電網(wǎng)運(yùn)行工作應(yīng)推行設(shè)備狀態(tài)管理理念,積極開展設(shè)備狀態(tài)評(píng)價(jià),逐步實(shí)現(xiàn)配電網(wǎng)設(shè)備定級(jí)工作從定性到定量的轉(zhuǎn)變。4.7統(tǒng)與現(xiàn)場(chǎng)巡視檢查作業(yè)平臺(tái),并采用標(biāo)準(zhǔn)化作業(yè)手段,不斷提升運(yùn)行工作水平與效率。54.8配電網(wǎng)運(yùn)行人員應(yīng)熟悉、執(zhí)行本規(guī)程,各單位可根據(jù)本規(guī)程編制實(shí)施細(xì)則。5配電網(wǎng)巡視檢查和防護(hù)5.1巡視檢查的一般要求5.1.1求,制定切實(shí)可行的管理辦法,編制計(jì)劃并合理安排線路、設(shè)備的巡視檢查(以下簡(jiǎn)稱巡視)工作,上級(jí)生產(chǎn)管理部門應(yīng)對(duì)運(yùn)行單位開展的巡視工作進(jìn)行監(jiān)督與考核。5.1.2巡視分類a)定期巡視:由配電網(wǎng)運(yùn)行人員進(jìn)行,以掌握設(shè)備設(shè)施的運(yùn)行狀況、運(yùn)行環(huán)境變化情況為目的,及時(shí)發(fā)現(xiàn)缺陷和威脅配電網(wǎng)安全運(yùn)行情況的巡視;b)特殊巡視:在有外力破壞可能、惡劣氣象條件(如大風(fēng)、暴雨、覆冰、高溫等)、部分巡視;c)夜間巡視:在負(fù)荷高峰或霧天的夜間由運(yùn)行單位組織進(jìn)行,主要檢查連接點(diǎn)有無過熱、打火現(xiàn)象,絕緣子表面有無閃絡(luò)等的巡視;d)故障巡視:由運(yùn)行單位組織進(jìn)行,以查明線路發(fā)生故障的地點(diǎn)和原因?yàn)槟康牡难惨?;e)監(jiān)察巡視:由管理人員組織進(jìn)行的巡視工作,了解線路及設(shè)備狀況,檢查、指導(dǎo)巡視人員的工作5.1.3巡視周期a1所示。得延長(zhǎng);bAc)重要線路和故障多發(fā)的線路每年至少進(jìn)行一次監(jiān)察巡視;表1巡視分類及巡視周期表郊區(qū)及農(nóng)村市區(qū)郊區(qū)及農(nóng)村中壓開閉所、環(huán)網(wǎng)單元、電纜分接箱配電室、箱式變電站防雷與接地裝置光纜隨所敷設(shè)配電設(shè)備巡視周期確定6根據(jù)需要(重要線路、重負(fù)荷和重污穢地區(qū)線路每半年至少巡視一次)故障巡視監(jiān)察巡視發(fā)生故障時(shí),無論重合是否成功重要線路和事故多發(fā)線路每年至少1次。5.1.4各單位應(yīng)積極建立各類有效的監(jiān)督檢查機(jī)制,確保巡視工作規(guī)范、有效。5.1.5巡視人員應(yīng)隨身攜帶相關(guān)資料及常用工具、備件和個(gè)人防護(hù)用品。5.1.6巡視人員在巡視檢查線路、設(shè)備時(shí),應(yīng)同時(shí)核對(duì)命名、編號(hào)、標(biāo)識(shí)等,并在滿足安全規(guī)程與確保安全的前提下,進(jìn)行維護(hù)和簡(jiǎn)單消缺工作,如清除設(shè)備下面生長(zhǎng)較高的雜草、蔓藤等工作。5.1.7線路設(shè)備名稱及發(fā)現(xiàn)的缺陷情況、缺陷類別,沿線危及線路設(shè)備安全的樹木、建筑和施工情況、存在外力破壞可能的情況、交叉跨越的變動(dòng)情況以及初步處理意見和情況等。5.1.8巡視人員在發(fā)現(xiàn)緊急(危急)缺陷時(shí)應(yīng)立即向班長(zhǎng)匯報(bào),并協(xié)助做好消缺工作;發(fā)現(xiàn)影響安全的施工作業(yè)情況,應(yīng)立即開展調(diào)查,做好現(xiàn)場(chǎng)宣傳、勸阻工作,并書面通知施工單位;巡視發(fā)現(xiàn)的問題要及時(shí)進(jìn)行記錄、分析、匯總,重大問題應(yīng)及時(shí)向有關(guān)部門匯報(bào)。5.1.9各單位應(yīng)進(jìn)一步加強(qiáng)對(duì)于外力破壞、惡劣氣象條件情況下的特殊巡視工作,確保配電網(wǎng)安全可靠運(yùn)行。5.1.10定期巡視的主要范圍a)架空線路、電纜及其附屬電氣設(shè)備;b)柱上變、柱上開關(guān)設(shè)備、中壓開關(guān)站、環(huán)網(wǎng)單元、配電室、箱式變電站等電氣設(shè)備;c)防雷與接地裝置、配電自動(dòng)化終端、直流電源、柱上電容器等設(shè)備;d)架空線路、電纜通道內(nèi)的樹木、違章建筑及懸掛、堆積物,周圍的挖溝、取土、修路、開山放炮及其它影響安全運(yùn)行的施工作業(yè)等;e)電纜管、溝(隧道)及相關(guān)設(shè)施;f)中壓開關(guān)站、環(huán)網(wǎng)單元、配電室的建筑物和相關(guān)輔助設(shè)施;g)各類相關(guān)的運(yùn)行、警示標(biāo)識(shí)及相關(guān)設(shè)施。5.1.11特殊巡視的主要范圍a)存在外力破壞可能或在惡劣氣象條件下影響安全運(yùn)行的線路及設(shè)備;b)設(shè)備缺陷近期有發(fā)展和有重大(嚴(yán)重)缺陷、異常情況的線路及設(shè)備;c)重要保電任務(wù)期間的線路及設(shè)備;d)新投運(yùn)、大修預(yù)試后、改造和長(zhǎng)期停用后重新投入運(yùn)行的線路及設(shè)備;e)根據(jù)檢修或試驗(yàn)情況,有薄弱環(huán)節(jié)或可能造成缺陷的線路及設(shè)備。5.2防護(hù)的一般要求5.2.1際情況,制定配電線路防護(hù)措施。5.2.2運(yùn)行單位應(yīng)加強(qiáng)與政府規(guī)劃、市政等有關(guān)部門的溝通,及時(shí)收集本地區(qū)的規(guī)劃建設(shè)、施工等信息,及時(shí)掌握外部環(huán)境的動(dòng)態(tài)情況與線路通道內(nèi)的施工情況,全面掌控其7施工狀態(tài)。5.2.3運(yùn)行單位應(yīng)加大防護(hù)宣傳,提高公民保護(hù)電力設(shè)施重要性的認(rèn)識(shí),定期組織召開防外力破壞作宣傳會(huì),防止各類外力破壞,及時(shí)發(fā)現(xiàn)并消除缺陷和隱患。5.2.4經(jīng)同意在線路保護(hù)范圍內(nèi)施工的,運(yùn)行單位必須嚴(yán)格審查施工方案,制定安全防護(hù)措施,并與施工單位簽訂保護(hù)協(xié)議書,明確雙方職責(zé);施工前應(yīng)對(duì)施工方進(jìn)行交底,包括路徑走向、架設(shè)高度、埋設(shè)深度、保護(hù)設(shè)施等;施工期間應(yīng)安排運(yùn)行人員到現(xiàn)場(chǎng)檢查防護(hù)措施,必要時(shí)進(jìn)行現(xiàn)場(chǎng)監(jiān)護(hù)。5.2.5及時(shí)對(duì)施工現(xiàn)場(chǎng)進(jìn)行拍照記錄,發(fā)送防護(hù)通知書,必要時(shí)應(yīng)向有關(guān)部門報(bào)告??赡芪<熬€路安全時(shí)應(yīng)進(jìn)行現(xiàn)場(chǎng)監(jiān)護(hù)。5.2.6對(duì)于造成電力設(shè)施損壞或事故的,應(yīng)按有關(guān)規(guī)定索賠或提請(qǐng)公安、司法機(jī)關(guān)依法處理。5.2.7運(yùn)行單位應(yīng)定期對(duì)外力破壞防護(hù)工作進(jìn)行總結(jié)分析,制定相應(yīng)防范措施。5.3架空線路的巡視5.3.1通道的巡視a)線路保護(hù)區(qū)內(nèi)有無易燃、易爆物品和腐蝕性液(氣)體;b)導(dǎo)線對(duì)地,對(duì)道路、公路、鐵路、索道、河流、建筑物等的距離應(yīng)符合附錄B的相關(guān)規(guī)定,有無可能觸及導(dǎo)線的鐵煙囪、天線、路燈等;c)有無存在可能被風(fēng)刮起危及線路安全的物體(如金屬薄膜、廣告牌、風(fēng)箏等);d)線路附近的爆破工程有無爆破手續(xù),其安全措施是否妥當(dāng);e)防護(hù)區(qū)內(nèi)栽植的樹、竹情況及導(dǎo)線與樹、竹的距離是否符合規(guī)定,有無蔓藤類植物附生威脅安全;f)是否存在對(duì)線路安全構(gòu)成威脅的工程設(shè)施(如施工機(jī)械、腳手架、拉線、開挖、地下采掘、打樁等);g)是否存在電力設(shè)施被擅自移作它用的現(xiàn)象h)線路附近出現(xiàn)的高大機(jī)械、攬風(fēng)索及可移動(dòng)的設(shè)施等;i)線路附近的污染源情況;j)線路附近河道、沖溝、山坡的變化,巡視、檢修時(shí)使用的道路、橋梁是否損壞,是否存在江河泛濫及山洪、泥石流對(duì)線路的影響;k)線路附近修建的道路、碼頭、貨物等;l)線路附近有無射擊、放風(fēng)箏、拋扔雜物、飄灑金屬和在桿塔、拉線上拴牲畜等;m)是否存在在建、已建違反《電力設(shè)施保護(hù)條例》及《電力設(shè)施保護(hù)條例實(shí)施細(xì)則》的建筑和構(gòu)筑物;n)通道內(nèi)有無未經(jīng)批準(zhǔn)擅自搭掛的弱電線路;o)其它可能影響線路安全的情況。5.3.2桿塔和基礎(chǔ)的巡視a)桿塔是否傾斜、位移,桿塔偏離線路中心不應(yīng)大于0.1m,砼桿傾斜不應(yīng)大于15/1000,轉(zhuǎn)角桿不應(yīng)向內(nèi)角傾斜,終端桿不應(yīng)向?qū)Ь€側(cè)傾斜,向拉線側(cè)傾斜應(yīng)小于0.2m;b)砼桿不應(yīng)有嚴(yán)重裂紋、鐵銹水,保護(hù)層不應(yīng)脫落、疏松、鋼筋外露,砼桿不宜有縱向裂紋,橫向裂紋不宜超過1/3周長(zhǎng),且裂紋寬度不宜大于0.5mm;焊接桿焊接處應(yīng)無裂紋,無嚴(yán)重銹蝕;鐵塔(鋼桿)不應(yīng)嚴(yán)重銹蝕,主材彎曲度不得超過5/1000,混凝土基礎(chǔ)不應(yīng)有裂紋、疏松、露筋;8c)基礎(chǔ)有無損壞、下沉、上拔,周圍土壤有無挖掘或沉陷,桿塔埋深是否符合要求;d)桿塔有無被水淹、水沖的可能,防洪設(shè)施有無損壞、坍塌;e)桿塔位置是否合適、有無被車撞的可能,保護(hù)設(shè)施是否完好,警示標(biāo)志是否清晰;f)線標(biāo)記等是否齊全、清晰明顯、規(guī)范統(tǒng)一、位置合適、安裝牢固;g)各部螺絲應(yīng)緊固,桿塔部件的固定處是否缺螺栓或螺母,螺栓是否松動(dòng)等;h)桿塔周圍有無藤蔓類攀沿植物和其它附著物,有無危及安全的鳥巢、風(fēng)箏及雜物;i)有無未經(jīng)批準(zhǔn)同桿搭掛設(shè)施或非同一電源的低壓配電線路;j)基礎(chǔ)保護(hù)帽上部塔材有無被埋入土或廢棄物堆中,塔材有無銹蝕、缺失。5.3.3橫擔(dān)、金具、絕緣子的巡視檢查a)鐵橫擔(dān)與金具有無嚴(yán)重銹蝕、變形、磨損、起皮或出現(xiàn)嚴(yán)重麻點(diǎn),銹蝕表面積不應(yīng)超過1/2,特別要注意檢查金具經(jīng)常活動(dòng)、轉(zhuǎn)動(dòng)的部位和絕緣子串懸掛點(diǎn)的金具;b)橫擔(dān)上下傾斜、左右偏斜不應(yīng)大于橫擔(dān)長(zhǎng)度的2%;c)螺栓是否緊固,有無缺螺帽、銷子,開口銷及彈簧銷有無銹蝕、斷裂、脫落;d)瓷質(zhì)絕緣子有無損傷、裂紋和閃絡(luò)痕跡,釉面剝落面積不應(yīng)大于100mm,合成絕緣子的絕緣介質(zhì)是否龜裂、破損、脫落;e)鐵腳、鐵帽有無銹蝕、松動(dòng)、彎曲偏斜;f)瓷橫擔(dān)、瓷頂擔(dān)是否偏斜;g)絕緣子鋼腳有無彎曲,鐵件有無嚴(yán)重銹蝕,針式絕緣子是否歪斜;h)在同一絕緣等級(jí)內(nèi),絕緣子裝設(shè)是否保持一致;i)鋁包帶、預(yù)絞絲有無滑動(dòng)、斷股或燒傷,防振錘有無移位、脫落、偏斜;j)驅(qū)鳥裝置工作是否正常。5.3.4拉線的巡視a當(dāng)一基電桿上裝設(shè)多條拉線時(shí),各條拉線的受力應(yīng)一致;b)跨越道路的水平拉線,對(duì)路邊緣的垂直距離不應(yīng)小于6m,跨越電車行車線的水平拉線,對(duì)路面的垂直距離不應(yīng)小于9m;c)拉線棒有無嚴(yán)重銹蝕、變形、損傷及上拔現(xiàn)象,必要時(shí)應(yīng)作局部開挖檢查;d)拉線基礎(chǔ)是否牢固,周圍土壤有無突起、沉陷、缺土等現(xiàn)象;e)拉線絕緣子是否破損或缺少,對(duì)地距離是否符合要求;f)拉線不應(yīng)設(shè)在妨礙交通(行人、車輛)或易被車撞的地方,無法避免時(shí)應(yīng)設(shè)有明顯警示標(biāo)志或采取其它保護(hù)措施,穿越帶電導(dǎo)線的拉線應(yīng)加設(shè)拉線絕緣子;g)拉線桿是否損壞、開裂、起弓、拉直;h)拉線的抱箍、拉線棒、UT型線夾、楔型線夾等金具鐵件有無變形、銹蝕、松動(dòng)或丟失現(xiàn)象;i)頂(撐)桿、拉線樁、保護(hù)樁(墩)等有無損壞、開裂等現(xiàn)象;j)拉線的UT型線夾有無被埋入土或廢棄物堆中;k)因環(huán)境變化,拉線是否妨礙交通。5.3.5導(dǎo)線的巡視a)導(dǎo)線有無斷股、損傷、燒傷、腐蝕的痕跡,綁扎線有無脫落、開裂,連接線夾螺栓股導(dǎo)線中任一股損傷深度不得超過該股導(dǎo)線直徑的1/2股及以上導(dǎo)線任一處的損傷不得超過3股;9b-5%或+10%,一般檔距內(nèi)弛度相差不宜超過50mm;c)導(dǎo)線連接部位是否良好,有無過熱變色和嚴(yán)重腐蝕,連接線夾是否缺失;d)跳(檔)線、引線有無損傷、斷股、彎扭;e)導(dǎo)線的線間距離,過引線、引下線與鄰相的過引線、引下線、導(dǎo)線之間的凈空距離以及導(dǎo)線與拉線、電桿或構(gòu)件的距離應(yīng)符合附錄B的規(guī)定;f)導(dǎo)線上有無拋扔物;g)架空絕緣導(dǎo)線有無過熱、變形、起泡現(xiàn)象;h)支持絕緣子綁扎線有無松馳和開斷現(xiàn)象;i)與絕緣導(dǎo)線直接接觸的金具絕緣罩是否齊全、有無開裂、發(fā)熱變色變形,接地環(huán)設(shè)置是否滿足要求;j)線夾、連接器上有無銹蝕或過熱現(xiàn)象(如:接頭變色、熔化痕跡等),連接線夾彈簧墊是否齊全,螺栓是否緊固;k)過引線有無損傷、斷股、松股、歪扭,與桿塔、構(gòu)件及其它引線間距離是否符合規(guī)定。5.4架空線路的防護(hù)5.4.1配電架空線路的防護(hù)區(qū)是為了保證線路的安全運(yùn)行和保障人民生活的正常供電5m并垂直于地面所形成的兩平行面內(nèi);在廠礦、城鎮(zhèn)等人口密集地區(qū),架空電力線路保護(hù)區(qū)的區(qū)域可略小于上述規(guī)定,的水平距離和風(fēng)偏后距建筑物的安全距離之和。5.4.2運(yùn)行單位需清除可能影響供電安全的物體時(shí),如:修剪樹枝、砍伐樹木及清理構(gòu)筑物等,應(yīng)按有關(guān)規(guī)定和程序進(jìn)行;修剪樹木,應(yīng)保證在修剪周期內(nèi)樹枝與導(dǎo)線的距離符合附錄B規(guī)定的數(shù)值。5.4.3運(yùn)行單位的工作人員對(duì)下列事項(xiàng)可先行處理,但事后應(yīng)及時(shí)通知有關(guān)單位:a)為避免觸電人身傷害及消除有可能造成嚴(yán)重后果的危急缺陷所采取的必要措施;b)為處理電力線路事故,砍伐林區(qū)個(gè)別樹木;c)消除影響供電安全的電視機(jī)天線、鐵煙囪、腳手架或其它凸出物等。5.4.4格按規(guī)定驗(yàn)收,并簽訂通道協(xié)議。5.4.5當(dāng)線路跨越主要通航江河時(shí),應(yīng)采取措施,設(shè)立標(biāo)志,防止船桅碰線。5.4.6在以下區(qū)域應(yīng)按規(guī)定設(shè)置明顯的警示標(biāo)志:a)架空電力線路穿越人口密集、人員活動(dòng)頻繁的地區(qū);b)車輛、機(jī)械頻繁穿越架空電力線路的地段;c)電力線路上的變壓器平臺(tái);d)臨近道路的拉線;e)電力線路附近的魚塘;f)桿塔腳釘、爬梯等。5.5電纜線路的巡視5.5.1通道的巡視a)路徑周邊有無挖掘、打樁、拉管、頂管等施工跡象,檢查路徑沿線各種標(biāo)識(shí)標(biāo)志是否齊全;b)電纜通道上方有無違章建筑物,是否堆置可燃物、雜物、重物、腐蝕物等;c)地面是否存在沉降;d)電纜工作井蓋是否丟失、破損、被掩埋;10e)電纜溝蓋板是否齊全完整并排列緊密;f)隧道進(jìn)出口設(shè)施是否完好,巡視和檢修通道是否暢通,沿線通風(fēng)口是否完好。5.5.2電纜管溝、隧道內(nèi)部的巡視a)結(jié)構(gòu)本體有無形變,支架、爬梯、樓梯等附屬設(shè)施及標(biāo)識(shí)、標(biāo)志是否完好;b)是否存在火災(zāi)、坍塌、盜竊、積水等隱患;c)是否存在溫度超標(biāo)、通風(fēng)不良、雜物堆積等缺陷,纜線孔洞的封堵是否完好;d)電纜固定金具是否齊全,隧道內(nèi)接地箱、交叉互聯(lián)箱的固定、外觀情況是否良好;e)機(jī)械通風(fēng)、照明、排水、消防、通訊、監(jiān)控、測(cè)溫等系統(tǒng)或設(shè)備是否運(yùn)行正常,是否存在隱患和缺陷;f)測(cè)量并記錄氧氣和可燃、有害氣體的成分和含量;g)是否存在未經(jīng)批準(zhǔn)的穿管施工。5.5.3電纜終端頭的巡視a)連接部位是否良好,有無過熱現(xiàn)象;bc)電纜終端頭和避雷器固定是否牢固;d)電纜上桿部分保護(hù)管及其封口是否完整。e)電纜終端有無放電現(xiàn)象;f)充油終端瓷套管是否完整、有無滲漏油,交聯(lián)電纜終端熱縮、冷縮或預(yù)制件有無開裂、積灰、電蝕或放電痕跡;g)相色是否清晰齊全;h)接地是否良好。5.5.4電纜中間接頭的巡視a)密封是否良好;b)是否有積水現(xiàn)象;c)標(biāo)志是否清晰齊全;d)連接部位是否良好,有無過熱變色、變形等現(xiàn)象。5.5.5電纜線路本體的巡視a)電纜線路的標(biāo)識(shí)、編號(hào)是否齊全、清晰;b)電纜線路排列是否整齊規(guī)范,是否按電壓等級(jí)的高低從下向上分層排列;通信光纜與電力電纜同溝時(shí)是否采取有效的隔離措施;c)電纜線路防火措施是否完備。5.5.6電纜分支箱的巡視a)基礎(chǔ)有無損壞、下沉,周圍土壤有無挖掘或沉陷,電纜有無外露,固定螺栓是否松動(dòng);b)殼體銹蝕損壞情況,外殼油漆是否剝落,內(nèi)裝式鉸鏈門開合是否靈活;c)箱內(nèi)有無進(jìn)水,有無小動(dòng)物、雜物、灰塵;d)電纜搭頭接觸是否良好,有無發(fā)熱、氧化、變色現(xiàn)象,電纜搭頭相間和對(duì)殼體、地面距離是否符合要求;e)有無異常聲音或氣味;f)箱內(nèi)其它設(shè)備運(yùn)行是否良好;g)名稱、銘牌、警告標(biāo)識(shí)、一次接線圖等是否清晰、正確;h)箱體內(nèi)電纜進(jìn)出線牌號(hào)與對(duì)側(cè)端標(biāo)牌是否對(duì)應(yīng),電纜命名牌是否齊全,肘頭相色是否齊全;i)電纜洞封口是否嚴(yán)密,箱內(nèi)底部填沙與基座是否齊平。5.5.7電纜溫度的檢測(cè)11a)多條并聯(lián)運(yùn)行的電纜以及電纜線路靠近熱力管或其它熱源、電纜排列密集處,應(yīng)進(jìn)行土壤溫度和電纜表面溫度監(jiān)視測(cè)量,以防電纜過熱;b)測(cè)量電纜的溫度,應(yīng)在夏季或電纜最大負(fù)荷時(shí)進(jìn)行;c)測(cè)量直埋電纜溫度時(shí),應(yīng)測(cè)量同地段的土壤溫度,測(cè)量土壤溫度的熱偶溫度計(jì)的裝置點(diǎn)與電纜間的距離不小于3m,離土壤測(cè)量點(diǎn)3m半徑范圍內(nèi)應(yīng)無其它熱源;d)電纜同地下熱力管交叉或接近敷設(shè)時(shí),電纜周圍的土壤溫度在任何時(shí)候不應(yīng)超過本地段其它地方同樣深度的土壤溫度10℃以上。5.6電纜線路的防護(hù)5.6.1電纜線路保護(hù)區(qū):地下電纜為電纜線路地面標(biāo)樁兩側(cè)各0.75m所形成的兩平行線內(nèi)的區(qū)域,保護(hù)區(qū)的寬度應(yīng)在地下電纜線路地面標(biāo)識(shí)樁(牌、磚)中注明;海底電纜一般為線路兩側(cè)各2海里(港內(nèi)為兩側(cè)各100m),江河電纜一般不小于線路兩側(cè)各100m(中、小河流一般不小于各50m)所形成的兩平行線內(nèi)的水域。5.6.2在電纜線路保護(hù)區(qū)內(nèi)不得堆放垃圾、礦渣、易燃物,傾倒酸、堿、鹽及其它有害化學(xué)物品,不得新建建筑物、開挖道路及種植樹木。5.6.3況時(shí),應(yīng)設(shè)置臨時(shí)防護(hù)措施,同時(shí)向管理部門報(bào)告。5.6.4直埋電纜在拐彎、中間接頭、終端和建筑物等地段,應(yīng)裝設(shè)明顯的方位標(biāo)志。5.6.5對(duì)處于施工區(qū)域的電纜線路,應(yīng)設(shè)置警告標(biāo)志牌,標(biāo)明保護(hù)范圍。5.6.6凡因施工必須挖掘而暴露的電纜,應(yīng)由運(yùn)行人員在場(chǎng)監(jiān)護(hù),并應(yīng)告知施工人員有關(guān)施工注意事項(xiàng)和保護(hù)措施;對(duì)于被挖掘而露出的電纜應(yīng)加裝保護(hù)罩,需要懸吊時(shí),懸吊間距應(yīng)不大于1.5m。5.6.7待恢復(fù)原狀后,方可離開現(xiàn)場(chǎng)。5.6.8水底電纜防護(hù)區(qū)域內(nèi),禁止船只拋錨,并按船只往來頻繁情況,必要時(shí)設(shè)置瞭望崗哨,配置能引起船只注意的設(shè)施;在水底電纜線路防護(hù)區(qū)域內(nèi)發(fā)生違反航行規(guī)定的事件,應(yīng)通知水域管轄的有關(guān)部門。5.7柱上開關(guān)設(shè)備的巡視5.7.1斷路器和負(fù)荷開關(guān)的巡視a)外殼有無滲、漏油和銹蝕現(xiàn)象;b)套管有無破損、裂紋和嚴(yán)重污染或放電閃絡(luò)的痕跡;c線間和對(duì)地距離是否滿足要求;d)氣體絕緣開關(guān)的壓力指示是否在允許范圍內(nèi),油絕緣開關(guān)油位是否正常;e)開關(guān)的命名、編號(hào),分、合和儲(chǔ)能位置指示,警示標(biāo)志等是否完好、正確、清晰;f)各個(gè)電氣連接點(diǎn)連接是否可靠,銅鋁過渡是否可靠,有無銹蝕、過熱和燒損現(xiàn)象。5.7.2隔離負(fù)荷開關(guān)、隔離開關(guān)、跌落式熔斷器的巡視a)絕緣件有無裂紋、閃絡(luò)、破損及嚴(yán)重污穢;b)熔絲管有無彎曲、變形;c)觸頭間接觸是否良好,有無過熱、燒損、熔化現(xiàn)象;d)各部件的組裝是否良好,有無松動(dòng)、脫落;e)引下線接點(diǎn)是否良好,與各部件間距是否合適;f)安裝是否牢固,相間距離、傾角是否符合規(guī)定;12g)操作機(jī)構(gòu)有無銹蝕現(xiàn)象;h)隔離負(fù)荷開關(guān)的滅弧室是否完好。5.8開關(guān)柜、環(huán)網(wǎng)柜的巡視a)各種儀表、保護(hù)裝置、信號(hào)裝置是否正常;b)開關(guān)分、合閘位置是否正確,與實(shí)際運(yùn)行方式是否相符,控制把手與指示燈位置對(duì)應(yīng),真空泡表面有無裂紋,SF6開關(guān)氣體壓力是否正常;c)開關(guān)防誤閉鎖是否完好,柜門關(guān)閉是否正常,油漆有無剝落;d)設(shè)備的各部件連接點(diǎn)接觸是否良好,有無放電聲,有無過熱變色、燒熔現(xiàn)象,示溫片是否熔化脫落;e)開關(guān)柜內(nèi)電纜終端是否接觸良好,電纜終端相間和對(duì)地距離是否符合要求;f)設(shè)備有無凝露,加熱器或除濕裝置是否處于良好狀態(tài);g)接地裝置是否良好,有無嚴(yán)重銹蝕、損壞;h)母線排有無變色變形現(xiàn)象,絕緣件有無裂紋、損傷、放電痕跡;i)模擬圖板或一次接線圖與現(xiàn)場(chǎng)是否一致;j)銘牌及各種標(biāo)志是否齊全、清晰;5.9配電變壓器的巡視ab)變壓器套管是否清潔,有無裂紋、擊穿、燒損和嚴(yán)重污穢,瓷套裙邊損傷面積不應(yīng)超過100mm;c)變壓器油溫、油色、油面是否正常,有無異聲、異味,在正常情況下,上層油溫不超過85℃,最高不得超過95℃;d)各部位密封圈(墊)有無老化、開裂,縫隙有無滲、漏油現(xiàn)象,配變外殼(箱式變電站箱體)有無脫漆、銹蝕,焊口有無裂紋、滲油;e)有載調(diào)壓配變分接開關(guān)指示位置是否正確;f全密封變壓器的壓力釋放裝置是否完好;g)變壓器有無異常的聲音,是否存在重載、超載現(xiàn)象;h)各種標(biāo)志是否齊全、清晰,銘牌及其警告牌和編號(hào)等其它標(biāo)識(shí)是否完好;i)變壓器臺(tái)架高度是否符合規(guī)定,有無銹蝕、傾斜、下沉,木構(gòu)件有無腐朽,磚、石結(jié)構(gòu)臺(tái)架有無裂縫和倒塌的可能;j)地面安裝變壓器的圍欄是否完好,平臺(tái)坡度不應(yīng)大于1/100;k)引線是否松弛,絕緣是否良好,相間或?qū)?gòu)件的距離是否符合規(guī)定,對(duì)工作人員有無觸電危險(xiǎn);l)溫度控制器(如有)顯示是否異常,巡視中應(yīng)對(duì)溫控裝置進(jìn)行自動(dòng)和手動(dòng)切換,觀察風(fēng)扇啟停是否正常等。5.10站所類建(構(gòu))筑物的巡視ab)建筑物的門、窗、鋼網(wǎng)有無損壞,房屋、設(shè)備基礎(chǔ)有無下沉、開裂,屋頂有無漏水、積水,沿溝有無堵塞;c)戶外環(huán)網(wǎng)單元、箱式變電站等設(shè)備的箱體有無銹蝕、變形;d)建筑物、戶外箱體的門鎖是否完好;e)電纜蓋板有無破損、缺失,進(jìn)出管溝封堵是否良好,防小動(dòng)物設(shè)施是否完好;f)室內(nèi)是否清潔,周圍有無威脅安全的堆積物,大門口是否暢通、是否影響檢修車輛通行;g)室內(nèi)溫度是否正常,有無異聲、異味;13h)室內(nèi)消防、照明設(shè)備、常用工器具完好齊備、擺放整齊,除濕、通風(fēng)、排水設(shè)施是否完好。5.11柱上電容器的巡視5.11.1巡視內(nèi)容a)絕緣件有無閃絡(luò)、裂紋、破損和嚴(yán)重臟污;b)有無滲、漏油;c)外殼有無膨脹、銹蝕;d)接地是否良好;e)放電回路及各引線接線是否良好;f)帶電導(dǎo)體與各部的間距是否合適;g)熔絲是否熔斷;5.11.2柱上電容器運(yùn)行中的最高溫度不應(yīng)超過制造廠規(guī)定值。5.12防雷和接地裝置的巡視5.12.1防雷裝置應(yīng)在雷季之前投入運(yùn)行。5.12.2接地電阻的測(cè)量周期:柱上變壓器、配電室、柱上開關(guān)設(shè)備、柱上電容器設(shè)備的接地電阻測(cè)量每?jī)赡赀M(jìn)行一次,其他設(shè)備的接地電阻測(cè)量每四年進(jìn)行一次,接地電阻測(cè)量應(yīng)在干燥天氣進(jìn)行。5.12.3總?cè)萘?00kVA及以上的變壓器其接地裝置的接地電阻不應(yīng)大于4復(fù)接地裝置的接地電阻不應(yīng)大于10;總?cè)萘繛?00kVA以下的變壓器,其接地裝置的接地電阻不應(yīng)大于10。5.12.4柱上開關(guān)、隔離開關(guān)和熔斷器防雷裝置的接地電阻,不應(yīng)大于10。5.12.5配電室接地裝置的接地電阻不應(yīng)大于4。5.12.6有避雷線的配電線路,其桿塔接地電阻不宜大于表2所列數(shù)值。表2電桿的接地電阻100500500100015205.12.7巡視內(nèi)容a)避雷器外觀有無破損、開裂,有無閃絡(luò)痕跡,表面是否臟污;b)避雷器上、下引線連接是否良好,引線與構(gòu)架、導(dǎo)線的距離是否符合規(guī)定;c)避雷器支架是否歪斜,鐵件有無銹蝕,固定是否牢固;d)帶脫離裝置的避雷器是否已動(dòng)作;e)防雷金具等保護(hù)間隙有無燒損,銹蝕或被外物短接,間隙距離是否符合規(guī)定;f)接地線和接地體的連接是否可靠,接地線絕緣護(hù)套是否破損,接地體有無外露、嚴(yán)重銹蝕,在埋設(shè)范圍內(nèi)有無土方工程;g)接地電阻是否滿足要求。5.13其它設(shè)備的巡視5.13.1配電終端設(shè)備(饋線終端、站所終端、配變終端等)的巡視14a)設(shè)備表面是否清潔,有無裂紋和缺損;b)二次端子排接線部分有無松動(dòng);c)交直流電源是否正常;d)柜門關(guān)閉是否良好,有無銹蝕、積灰,電纜進(jìn)出孔封堵是否完好;e)終端設(shè)備運(yùn)行工況是否正常,各指示燈信號(hào)是否正常;f)通信是否正常,能否接收主站發(fā)下來的報(bào)文;g)遙測(cè)數(shù)據(jù)是否正常,遙信位置是否正確;h)設(shè)備的接地是否牢固可靠,終端裝置電纜線頭的標(biāo)號(hào)是否清晰正確、有無松動(dòng);i)對(duì)終端裝置參數(shù)定值等進(jìn)行核實(shí)及時(shí)鐘校對(duì),做好相關(guān)數(shù)據(jù)的常態(tài)備份工作;j)檢查相關(guān)二次安全防護(hù)設(shè)備運(yùn)行是否正常;k)檢查有無工況退出站點(diǎn),有無遙測(cè)、遙信信息異常情況。5.13.2直流電源設(shè)備的巡視a)蓄電池是否滲液、老化;b)箱體有無銹蝕及滲漏;c)檢查蓄電池電壓是否正常,浮充電流是否正常;d)檢查直流電源箱、直流屏各項(xiàng)指示燈信號(hào)是否正常,開關(guān)位置是否正確,液晶屏顯是否正常。6.1缺陷及隱患管理6.1.1運(yùn)行單位應(yīng)制定缺陷及隱患管理流程,對(duì)缺陷及隱患的上報(bào)、定性、處理和驗(yàn)收等環(huán)節(jié)實(shí)行閉環(huán)管理。6.1.2運(yùn)行單位應(yīng)建立缺陷及隱患管理臺(tái)賬,及時(shí)更新核對(duì),保證臺(tái)賬與實(shí)際相符。6.1.3缺陷的分類原則:a)一般缺陷:設(shè)備本身及周圍環(huán)境出現(xiàn)不正常情況,一般不威脅設(shè)備的安全運(yùn)行,可列入小修計(jì)劃進(jìn)行處理的缺陷;b)重大(嚴(yán)重)缺陷:設(shè)備處于異常狀態(tài),可能發(fā)展為事故,但設(shè)備仍可在一定時(shí)間內(nèi)繼續(xù)運(yùn)行,須加強(qiáng)監(jiān)視并進(jìn)行大修處理的缺陷;c)緊急(危急)缺陷:嚴(yán)重威脅設(shè)備的安全運(yùn)行,不及時(shí)處理,隨時(shí)有可能導(dǎo)致事故的發(fā)生,必須盡快消除或采取必要的安全技術(shù)措施進(jìn)行處理的缺陷。6.1.4-上報(bào)管理部門-安排檢修計(jì)劃-檢修消缺-運(yùn)行驗(yàn)收,形成閉環(huán)管理,缺陷管理資料應(yīng)歸檔保存;缺陷管理實(shí)行網(wǎng)上流轉(zhuǎn)的,也應(yīng)按以上閉環(huán)管理流程從網(wǎng)上進(jìn)行流轉(zhuǎn)管理。6.1.5緊急(危急)缺陷消除時(shí)間不得超過24小時(shí),重大(嚴(yán)重)缺陷應(yīng)在7天內(nèi)消除,一般缺陷可結(jié)合檢修計(jì)劃盡早消除,但應(yīng)處于可控狀態(tài)。6.1.6設(shè)備帶缺陷運(yùn)行期間,運(yùn)行單位應(yīng)加強(qiáng)監(jiān)視,必要時(shí)制定相應(yīng)應(yīng)急措施。6.1.7運(yùn)行單位定期開展缺陷統(tǒng)計(jì)分析工作,及時(shí)掌握缺陷消除情況和缺陷產(chǎn)生的原因,有針對(duì)性采取相應(yīng)措施。6.1.8發(fā)現(xiàn)-評(píng)估-報(bào)告-治理(控制)-驗(yàn)收-銷號(hào)”的流程形成閉環(huán)管理。6.1.9根據(jù)可能造成的事故后果,事故隱患分為重大事故隱患和一般事故隱患兩級(jí)。a)重大事故隱患:是指可能造成人身死亡事故,重大及以上電網(wǎng)、設(shè)備事故,由于供電原因可能導(dǎo)致重要電力用戶嚴(yán)重生產(chǎn)事故的事故隱患;15b)一般事故隱患:是指可能造成人身重傷事故,一般電網(wǎng)和設(shè)備事故的事故隱患。6.2運(yùn)行分析6.2.1根據(jù)配電網(wǎng)管理工作、運(yùn)行情況、巡視結(jié)果、狀態(tài)評(píng)價(jià)等信息對(duì)配電網(wǎng)進(jìn)行運(yùn)行分析,對(duì)運(yùn)行工作中出現(xiàn)的帶有共性的問題進(jìn)行有針對(duì)性地分析,提出解決辦法,提高運(yùn)行管理水平。6.2.2通過運(yùn)行分析,運(yùn)行單位應(yīng)對(duì)存在的問題進(jìn)行分類,并結(jié)合配電網(wǎng)基建、技改、大修項(xiàng)目制定整改計(jì)劃。6.2.3配電網(wǎng)運(yùn)行分析內(nèi)容應(yīng)包括:運(yùn)行管理工作分析、運(yùn)行情況分析、缺陷及故障分析以及負(fù)荷分析等。6.2.4配電網(wǎng)運(yùn)行分析周期為每季度一次。6.2.5運(yùn)行管理工作分析內(nèi)容a)配電網(wǎng)運(yùn)行管理方面是否存在薄弱環(huán)節(jié);b)規(guī)章制度是否齊全,現(xiàn)場(chǎng)標(biāo)識(shí)、標(biāo)志,警示是否齊全、醒目;c)圖紙資料與現(xiàn)場(chǎng)是否相符;d)倒閘操作是否符合規(guī)定;e)巡視工作是否到位;f)試驗(yàn)工作是否按規(guī)定開展;g)負(fù)荷測(cè)試、紅外測(cè)溫等工作是否符合要求;h)運(yùn)行資料記錄是否齊全、完整。6.2.6運(yùn)行情況分析內(nèi)容包括但不限于:a)是否存在供電“瓶頸”的情況;b)是否存在設(shè)備老化、設(shè)備不滿足規(guī)范要求的情況;c)是否存在公用配變布點(diǎn)不合理、超載情況;d)是否存在設(shè)備家族性缺陷情況;e)是否存在外部環(huán)境、施工影響配電網(wǎng)安全運(yùn)行的情況;f)特殊天氣條件下的設(shè)備運(yùn)行情況;g)是否存在電壓質(zhì)量不合格、無功補(bǔ)償不足的情況。6.2.7缺陷及故障分析a)配網(wǎng)缺陷應(yīng)分類統(tǒng)計(jì)、分析,找出缺陷產(chǎn)生的原因,分析是否存在設(shè)備質(zhì)量、施工質(zhì)量、運(yùn)行維護(hù)缺失、管理漏洞等因素;b)分析故障發(fā)生原因、發(fā)展的過程,可能造成的危害,提出今后重點(diǎn)預(yù)防的措施;c)通過缺陷和故障分析,找出配電網(wǎng)存在的問題與薄弱環(huán)節(jié)。6.3標(biāo)志標(biāo)識(shí)6.3.1配電網(wǎng)設(shè)備設(shè)施的標(biāo)志標(biāo)識(shí),應(yīng)符合電力安全工作規(guī)程要求,保證電力安全運(yùn)行需要。6.3.2所有已投運(yùn)的配電設(shè)備應(yīng)具有正確齊全的設(shè)備標(biāo)識(shí),同一調(diào)度權(quán)限范圍內(nèi),設(shè)備名稱及編號(hào)應(yīng)唯一。6.3.3標(biāo)識(shí)規(guī)范應(yīng)按照國(guó)家電網(wǎng)公司統(tǒng)一的技術(shù)規(guī)范要求執(zhí)行。6.3.4配電線路及設(shè)備的現(xiàn)場(chǎng)標(biāo)識(shí)牌、警示牌應(yīng)完好、齊全、清晰、規(guī)范,裝設(shè)位置明顯、直觀,缺損時(shí)應(yīng)及時(shí)補(bǔ)充和恢復(fù)。6.3.5新建和改造的配電設(shè)備應(yīng)在投運(yùn)前完善相關(guān)的標(biāo)志標(biāo)識(shí)。6.3.6需要進(jìn)行標(biāo)識(shí)主要設(shè)備設(shè)施有:16a)架空線路桿塔上的線路名稱、編號(hào)、桿塔編號(hào)、特殊編碼,同桿架設(shè)的多回線路的不同色標(biāo);b)柱上變、柱上開關(guān)設(shè)備、中壓開關(guān)站、環(huán)網(wǎng)單元、配電室、箱式變電站等設(shè)備的名稱、編碼及適當(dāng)?shù)木九疲籧)聯(lián)絡(luò)開關(guān)的警告標(biāo)志;d)終端懸掛的電纜桿上部分、電纜井內(nèi)的電纜本體的名稱、型號(hào)及相關(guān)信息;e)直埋電纜的地面標(biāo)志樁;f)電纜工作井、電纜隧道的名稱、編碼;g)靠近道口及較有可能發(fā)生車輛撞擊或外力事故的電桿、拉線、戶外環(huán)網(wǎng)單元、電纜分支箱等的反光漆標(biāo)志;h)同桿架設(shè)的不同電源警告牌;i)出線桿、分支桿、轉(zhuǎn)角桿、電纜桿反映導(dǎo)線相位的相色標(biāo)志;j)電纜終端頭、設(shè)備接線端子的相色標(biāo)志;k)其它存在安全隱患而應(yīng)設(shè)置警示標(biāo)識(shí)的。17附錄(規(guī)范性附錄)架空電力線路污穢分級(jí)標(biāo)準(zhǔn)架空電力線路污穢分級(jí)標(biāo)準(zhǔn)見表。表A.1架空電力線路污穢分級(jí)標(biāo)準(zhǔn)cm/kV直接接地a大氣清潔地區(qū)及離海岸鹽場(chǎng)50km以上無明顯污染地區(qū)場(chǎng)~50km地區(qū)。在污閃季節(jié)中干燥少霧(含毛毛雨)或雨量較多時(shí)b場(chǎng)~10km地區(qū)。在污閃季節(jié)中潮濕多霧(含毛毛雨)但雨量較少時(shí)c注:本表格根據(jù)GB/T16434《高壓架空線路和發(fā)電廠、變電所環(huán)境污區(qū)分級(jí)及外絕緣選擇標(biāo)準(zhǔn)》而定。18供電公司配電網(wǎng)運(yùn)行規(guī)程
溫馨提示
- 1. 本站所有資源如無特殊說明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請(qǐng)下載最新的WinRAR軟件解壓。
- 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請(qǐng)聯(lián)系上傳者。文件的所有權(quán)益歸上傳用戶所有。
- 3. 本站RAR壓縮包中若帶圖紙,網(wǎng)頁內(nèi)容里面會(huì)有圖紙預(yù)覽,若沒有圖紙預(yù)覽就沒有圖紙。
- 4. 未經(jīng)權(quán)益所有人同意不得將文件中的內(nèi)容挪作商業(yè)或盈利用途。
- 5. 人人文庫(kù)網(wǎng)僅提供信息存儲(chǔ)空間,僅對(duì)用戶上傳內(nèi)容的表現(xiàn)方式做保護(hù)處理,對(duì)用戶上傳分享的文檔內(nèi)容本身不做任何修改或編輯,并不能對(duì)任何下載內(nèi)容負(fù)責(zé)。
- 6. 下載文件中如有侵權(quán)或不適當(dāng)內(nèi)容,請(qǐng)與我們聯(lián)系,我們立即糾正。
- 7. 本站不保證下載資源的準(zhǔn)確性、安全性和完整性, 同時(shí)也不承擔(dān)用戶因使用這些下載資源對(duì)自己和他人造成任何形式的傷害或損失。
最新文檔
- 2025-2030葡萄酒莊企業(yè)經(jīng)營(yíng)模式市場(chǎng)分析評(píng)估發(fā)展大綱
- 2025-2030葡萄牙葡萄酒酒莊有機(jī)認(rèn)證覆蓋率深究及箱式烘焙設(shè)備改造方案與法國(guó)南部的市場(chǎng)接受程度分析提案報(bào)告
- 2022年燃?xì)獍踩a(chǎn)管理人員模擬100題(含答案)真題題庫(kù)
- 2025年安全生產(chǎn)管理工程師安全隱患排查與整改試題及答案
- 2025能源管理試題及答案解析
- 2026年廢臭氧污染易發(fā)區(qū)保護(hù)保險(xiǎn)合同中
- 2026年車主會(huì)員服務(wù)合同
- 2026年物流管理理論與實(shí)踐案例分析題
- 2026年入門學(xué)習(xí)手冊(cè)初級(jí)專業(yè)考試題目
- 2025年煤礦安全生產(chǎn)知識(shí)試題庫(kù)(含答案)
- 2026海南安保控股有限責(zé)任公司招聘11人筆試模擬試題及答案解析
- 2026年張家界航空工業(yè)職業(yè)技術(shù)學(xué)院?jiǎn)握新殬I(yè)傾向性考試模擬測(cè)試卷新版
- 2026遼寧機(jī)場(chǎng)管理集團(tuán)校招面筆試題及答案
- 2025徽銀金融租賃有限公司社會(huì)招聘筆試歷年典型考題及考點(diǎn)剖析附帶答案詳解
- 2026年遼寧軌道交通職業(yè)學(xué)院?jiǎn)握芯C合素質(zhì)筆試備考題庫(kù)帶答案解析
- DB44-T 2771-2025 全域土地綜合整治技術(shù)導(dǎo)則
- 碳排放核算及企業(yè)減排策略
- 冬季電氣設(shè)備安全培訓(xùn)課件
- 安徽省滁州市天長(zhǎng)市2025年小學(xué)六年級(jí)期末數(shù)學(xué)試卷及答案
- 高密度聚乙烯(HDPE)排水管(八角雙密封)
- 高速公路通信設(shè)備維護(hù)手冊(cè)
評(píng)論
0/150
提交評(píng)論