序號(hào),測(cè)點(diǎn)編碼,測(cè)點(diǎn)名稱(chēng),"I/O
類(lèi)型","電氣
特性",電源,"工程
單位",量程,"接點(diǎn)
特性",HH,H,L,LL,參考圖,備注
,,煙氣系統(tǒng),,,,,,,,,,,,
1,J0HTW03CT001,擋板密封風(fēng)總管溫度,AI,4-20mA,USER,,,,,,,,J0202-002,
2,J0HTW03CP001,擋板密封風(fēng)總管壓力,AI,4-20mA,USER,,,,,,,,J0202-002,
3,J0HTW01AN001YB01,啟動(dòng)#1機(jī)A密封風(fēng)機(jī),DO,220VAC,USER,,,,,,,,J0202-002,
4,J0HTW01AN001YB02,停止#1機(jī)A密封風(fēng)機(jī),DO,220VAC,USER,,,,,,,,J0202-002,
5,J0HTW01AN001XB01,#1機(jī)A密封風(fēng)機(jī)已運(yùn)行,DI,48VDC,DCS,,,,,,,,J0202-002,
6,J0HTW01AN001XB02,#1機(jī)A密封風(fēng)機(jī)已停止,DI,48VDC,DCS,,,,,,,,J0202-002,
7,J0HTW01AN001XB05,#1機(jī)A密封風(fēng)機(jī)故障,DI,48VDC,DCS,,,,,,,,J0202-002,
8,J0HTW02AN001YB01,啟動(dòng)#1機(jī)B密封風(fēng)機(jī),DO,220VAC,USER,,,,,,,,J0202-002,
9,J0HTW02AN001YB02,停止#1機(jī)B密封風(fēng)機(jī),DO,220VAC,USER,,,,,,,,J0202-002,
10,J0HTW02AN001XB01,#1機(jī)B密封風(fēng)機(jī)已運(yùn)行,DI,48VDC,DCS,,,,,,,,J0202-002,
11,J0HTW02AN001XB02,#1機(jī)B密封風(fēng)機(jī)已停止,DI,48VDC,DCS,,,,,,,,J0202-002,
12,J0HTW02AN001XB05,#1機(jī)B密封風(fēng)機(jī)故障,DI,48VDC,DCS,,,,,,,,J0202-002,
13,J0HTW03AC001YB01,啟動(dòng)擋板密封風(fēng)電加熱器,DO,220VAC,USER,,,,,,,,J0202-002,
14,J0HTW03AC001YB02,停止擋板密封風(fēng)電加熱器,DO,220VAC,USER,,,,,,,,J0202-002,
15,J0HTW03AC001XB01,擋板密封風(fēng)電加熱器已運(yùn)行,DI,48VDC,DCS,,,,,,,,J0202-002,
16,J0HTW03AC001XB02,擋板密封風(fēng)電加熱器已停止,DI,48VDC,DCS,,,,,,,,J0202-002,
17,J0HTW03AC001XB04,電加熱器遠(yuǎn)程控制狀態(tài)信號(hào),DI,48VDC,DCS,,,,,,,,J0202-002,
18,J0HTW03AC001XB05,擋板密封風(fēng)電加熱器超溫報(bào)警,DI,48VDC,DCS,,,,,,,,J0202-002,
19,J0HTW03AC001XB06,擋板密封風(fēng)電加熱器欠溫報(bào)警,DI,48VDC,DCS,,,,,,,,J0202-002,
,,石灰石粉倉(cāng)制漿箱系統(tǒng),,,,,,,,,,,,
20,J0HTM37AP001YQ01,#1機(jī)組#1粉倉(cāng)制漿泵轉(zhuǎn)速給定,AO,4~20mA,DCS,Hz,0-50,,,,,,J0202-008,
21,J0HTM37AP001XQ01,#1機(jī)組#1粉倉(cāng)制漿泵轉(zhuǎn)速反饋,AI,4~20mA,USER,Hz,0-50,,,,,,J0202-008,
22,J0HTM37AP001XQ02,#1機(jī)組#1粉倉(cāng)制漿泵電流,AI,4~20mA,USER,A,,,,,,,J0202-008,
23,J0HTM37AP001YB01,#1機(jī)組#1粉倉(cāng)制漿泵啟動(dòng),DO,,USER,,,"NO
220VAC",,,,,J0202-008,
24,J0HTM37AP001YB02,#1機(jī)組#1粉倉(cāng)制漿泵停止,DO,,USER,,,"NO
220VAC",,,,,J0202-008,
25,J0HTM37AP001YB03,#1機(jī)組#1粉倉(cāng)制漿泵變頻器風(fēng)機(jī)啟動(dòng),DO,,USER,,,"NO
220VAC",,,,,J0202-008,
26,J0HTM37AP001YB04,#1機(jī)組#1粉倉(cāng)制漿泵變頻器風(fēng)機(jī)停止,DO,,USER,,,"NO
220VAC",,,,,J0202-008,
27,J0HTM37AP001XB01,#1機(jī)組#1粉倉(cāng)制漿泵變頻器準(zhǔn)備就緒,DI,,DCS,,,,,,,,J0202-008,
28,J0HTM37AP001XB02,#1機(jī)組#1粉倉(cāng)制漿泵變頻器運(yùn)行狀態(tài),DI,,DCS,,,,,,,,J0202-008,
29,J0HTM37AP001XB03,#1機(jī)組#1粉倉(cāng)制漿泵遠(yuǎn)方/就地,DI,,DCS,,,,,,,,J0202-008,
30,J0HTM37AP001XB04,#1機(jī)組#1粉倉(cāng)制漿泵變頻器故障,DI,,DCS,,,,,,,,J0202-008,
31,J0HTM37AP002YQ01,#1機(jī)組#2粉倉(cāng)制漿泵轉(zhuǎn)速給定,AO,4~20mA,DCS,Hz,0-50,,,,,,J0202-008,
32,J0HTM37AP002XQ01,#1機(jī)組#2粉倉(cāng)制漿泵轉(zhuǎn)速反饋,AI,4~20mA,USER,Hz,0-50,,,,,,J0202-008,
33,J0HTM37AP002XQ02,#1機(jī)組#2粉倉(cāng)制漿泵電流,AI,4~20mA,USER,A,,,,,,,J0202-008,
34,J0HTM37AP002YB01,#1機(jī)組#2粉倉(cāng)制漿泵啟動(dòng),DO,,USER,,,"NO
220VAC",,,,,J0202-008,
35,J0HTM37AP002YB02,#1機(jī)組#2粉倉(cāng)制漿泵停止,DO,,USER,,,"NO
220VAC",,,,,J0202-008,
36,J0HTM37AP002YB03,#1機(jī)組#2粉倉(cāng)制漿泵變頻器風(fēng)機(jī)啟動(dòng),DO,,USER,,,"NO
220VAC",,,,,J0202-008,
37,J0HTM37AP002YB04,#1機(jī)組#2粉倉(cāng)制漿泵變頻器風(fēng)機(jī)停止,DO,,USER,,,"NO
220VAC",,,,,J0202-008,
38,J0HTM37AP002XB01,#1機(jī)組#2粉倉(cāng)制漿泵變頻器準(zhǔn)備就緒,DI,,DCS,,,,,,,,J0202-008,
39,J0HTM37AP002XB02,#1機(jī)組#2粉倉(cāng)制漿泵變頻器運(yùn)行狀態(tài),DI,,DCS,,,,,,,,J0202-008,
40,J0HTM37AP002XB03,#1機(jī)組#2粉倉(cāng)制漿泵遠(yuǎn)方/就地,DI,,DCS,,,,,,,,J0202-008,
41,J0HTM37AP002XB04,#1機(jī)組#2粉倉(cāng)制漿泵變頻器故障,DI,,DCS,,,,,,,,J0202-008,
42,J0HTM38AP001YQ01,#2機(jī)組#1粉倉(cāng)制漿泵轉(zhuǎn)速給定,AO,4~20mA,DCS,Hz,0-50,,,,,,J0202-008,
43,J0HTM38AP001XQ01,#2機(jī)組#1粉倉(cāng)制漿泵轉(zhuǎn)速反饋,AI,4~20mA,USER,Hz,0-50,,,,,,J0202-008,
44,J0HTM38AP001XQ02,#2機(jī)組#1粉倉(cāng)制漿泵電流,AI,4~20mA,USER,A,,,,,,,J0202-008,
45,J0HTM38AP001YB01,#2機(jī)組#1粉倉(cāng)制漿泵啟動(dòng),DO,,USER,,,"NO
220VAC",,,,,J0202-008,
46,J0HTM38AP001YB02,#2機(jī)組#1粉倉(cāng)制漿泵停止,DO,,USER,,,"NO
220VAC",,,,,J0202-008,
47,J0HTM38AP001YB03,#2機(jī)組#1粉倉(cāng)制漿泵變頻器風(fēng)機(jī)啟動(dòng),DO,,USER,,,"NO
220VAC",,,,,J0202-008,
48,J0HTM38AP001YB04,#2機(jī)組#1粉倉(cāng)制漿泵變頻器風(fēng)機(jī)停止,DO,,USER,,,"NO
220VAC",,,,,J0202-008,
49,J0HTM38AP001XB01,#2機(jī)組#1粉倉(cāng)制漿泵變頻器準(zhǔn)備就緒,DI,,DCS,,,,,,,,J0202-008,
50,J0HTM38AP001XB02,#2機(jī)組#1粉倉(cāng)制漿泵變頻器運(yùn)行狀態(tài),DI,,DCS,,,,,,,,J0202-008,
51,J0HTM38AP001XB03,#2機(jī)組#1粉倉(cāng)制漿泵遠(yuǎn)方/就地,DI,,DCS,,,,,,,,J0202-008,
52,J0HTM38AP001XB04,#2機(jī)組#1粉倉(cāng)制漿泵變頻器故障,DI,,DCS,,,,,,,,J0202-008,
53,J0HTM38AP002YQ01,#2機(jī)組#2粉倉(cāng)制漿泵轉(zhuǎn)速給定,AO,4~20mA,DCS,Hz,0-50,,,,,,J0202-008,
54,J0HTM38AP002XQ01,#2機(jī)組#2粉倉(cāng)制漿泵轉(zhuǎn)速反饋,AI,4~20mA,USER,Hz,0-50,,,,,,J0202-008,
55,J0HTM38AP002XQ02,#2機(jī)組#2粉倉(cāng)制漿泵電流,AI,4~20mA,USER,A,,,,,,,J0202-008,
56,J0HTM38AP002YB01,#2機(jī)組#2粉倉(cāng)制漿泵啟動(dòng),DO,,USER,,,"NO
220VAC",,,,,J0202-008,
57,J0HTM38AP002YB02,#2機(jī)組#2粉倉(cāng)制漿泵停止,DO,,USER,,,"NO
220VAC",,,,,J0202-008,
58,J0HTM38AP002YB03,#2機(jī)組#2粉倉(cāng)制漿泵變頻器風(fēng)機(jī)啟動(dòng),DO,,USER,,,"NO
220VAC",,,,,J0202-008,
59,J0HTM38AP002YB04,#2機(jī)組#2粉倉(cāng)制漿泵變頻器風(fēng)機(jī)停止,DO,,USER,,,"NO
220VAC",,,,,J0202-008,
60,J0HTM38AP002XB01,#2機(jī)組#2粉倉(cāng)制漿泵變頻器準(zhǔn)備就緒,DI,,DCS,,,,,,,,J0202-008,
61,J0HTM38AP002XB02,#2機(jī)組#2粉倉(cāng)制漿泵變頻器運(yùn)行狀態(tài),DI,,DCS,,,,,,,,J0202-008,
62,J0HTM38AP002XB03,#2機(jī)組#2粉倉(cāng)制漿泵遠(yuǎn)方/就地,DI,,DCS,,,,,,,,J0202-008,
63,J0HTM38AP002XB04,#2機(jī)組#2粉倉(cāng)制漿泵變頻器故障,DI,,DCS,,,,,,,,J0202-008,
,,石灰石漿液輸送系統(tǒng),,,,,,,,,,,,
64,J0THM30AA012YB01,#1機(jī)石灰石漿液至#1吸收塔閥開(kāi)指令,DO,,USER,,,NO,,,,,J0202-009,
65,J0THM30AA012YB02,#1機(jī)石灰石漿液至#1吸收塔閥關(guān)指令,DO,,USER,,,NO,,,,,J0202-009,
66,J0THM30AA012XB01,#1機(jī)石灰石漿液至#1吸收塔閥已開(kāi),DI,,DCS,,,NO,,,,,J0202-009,
67,J0THM30AA012XB02,#1機(jī)石灰石漿液至#1吸收塔閥已關(guān),DI,,DCS,,,NO,,,,,J0202-009,
68,J0THM30AA013YB01,#1機(jī)石灰石漿液至事故漿液箱閥開(kāi)指令,DO,,USER,,,NO,,,,,J0202-009,
69,J0THM30AA013YB02,#1機(jī)石灰石漿液至事故漿液箱閥關(guān)指令,DO,,USER,,,NO,,,,,J0202-009,
70,J0THM30AA013XB01,#1機(jī)石灰石漿液至事故漿液箱閥已開(kāi),DI,,DCS,,,NO,,,,,J0202-009,
71,J0THM30AA013XB02,#1機(jī)石灰石漿液至事故漿液箱閥已關(guān),DI,,DCS,,,NO,,,,,J0202-009,
,,工藝水系統(tǒng),,,,,,,,,,,,
72,J0HTQ10AA105YQ01,工藝水箱來(lái)水調(diào)節(jié)閥調(diào)節(jié)指令,AO,4~20mA,DCS,%,0-100,,,,,,J0202-010,
73,J0HTQ10AA105XQ01,工藝水箱來(lái)水調(diào)節(jié)閥調(diào)節(jié)反饋,AI,4~20mA,USER,%,0-100,,,,,,J0202-010,
74,J0HTQ10CF101,工藝水箱來(lái)水流量,AI,4~20mA,USER,m3/h,0-200,,,,,,J0202-010,
,,密封冷卻水系統(tǒng),,,,,,,,,,,,
75,00HTQ60AP001YB01,冷卻水增壓泵合閘,DO,,USER,,,"NO
220VAC",,,,,J0202-011,
76,00HTQ60AP001YB02,冷卻水增壓泵分閘,DO,,USER,,,"NO
220VAC",,,,,J0202-011,
77,00HTQ60AP001XB01,冷卻水增壓泵合閘位置,DI,,DCS,,,,,,,,J0202-011,
78,00HTQ60AP001XB02,冷卻水增壓泵分閘位置,DI,,DCS,,,,,,,,J0202-011,
79,00HTQ60AP001XB03,冷卻水增壓泵遠(yuǎn)方/就地,DI,,DCS,,,,,,,,J0202-011,
80,00HTQ60AP001XB04,冷卻水增壓泵故障跳閘,DI,,DCS,,,,,,,,J0202-011,
,,廢水系統(tǒng),,,,,,,,,,,,
80,J0HTM09AP001YQ01,廢水出水泵A轉(zhuǎn)速給定,AO,4~20mA,DCS,Hz,0-50,,,,,,J0202-012,
81,J0HTM09AP001XQ01,廢水出水泵A轉(zhuǎn)速反饋,AI,4~20mA,USER,Hz,0-50,,,,,,J0202-012,
82,J0HTM09AP001XQ02,廢水出水泵A電流,AI,4~20mA,USER,A,,,,,,,J0202-012,
83,J0HTM09AP001YB01,廢水出水泵A啟動(dòng),DO,,USER,,,"NO
220VAC",,,,,J0202-012,
84,J0HTM09AP001YB02,廢水出水泵A停止,DO,,USER,,,"NO
220VAC",,,,,J0202-012,
85,J0HTM09AP001YB03,廢水出水泵A變頻器風(fēng)機(jī)啟動(dòng),DO,,USER,,,"NO
220VAC",,,,,J0202-012,
86,J0HTM09AP001YB04,廢水出水泵A變頻器風(fēng)機(jī)停止,DO,,USER,,,"NO
220VAC",,,,,J0202-012,
87,J0HTM09AP001XB01,廢水出水泵A變頻器準(zhǔn)備就緒,DI,,DCS,,,,,,,,J0202-012,
88,J0HTM09AP001XB02,廢水出水泵A變頻器運(yùn)行狀態(tài),DI,,DCS,,,,,,,,J0202-012,
89,J0HTM09AP001XB03,廢水出水泵A遠(yuǎn)方/就地,DI,,DCS,,,,,,,,J0202-012,
90,J0HTM09AP001XB04,廢水出水泵A變頻器故障,DI,,DCS,,,,,,,,J0202-012,
91,J0HTM10AP001YQ01,廢水出水泵B轉(zhuǎn)速給定,AO,4~20mA,DCS,Hz,0-50,,,,,,J0202-012,
92,J0HTM10AP001XQ01,廢水出水泵B轉(zhuǎn)速反饋,AI,4~20mA,USER,Hz,0-50,,,,,,J0202-012,
93,J0HTM10AP001XQ02,廢水出水泵B電流,AI,4~20mA,USER,A,,,,,,,J0202-012,
94,J0HTM10AP001YB01,廢水出水泵B啟動(dòng),DO,,USER,,,"NO
220VAC",,,,,J0202-012,
95,J0HTM10AP001YB02,廢水出水泵B停止,DO,,USER,,,"NO
220VAC",,,,,J0202-012,
96,J0HTM10AP001YB03,廢水出水泵B變頻器風(fēng)機(jī)啟動(dòng),DO,,USER,,,"NO
220VAC",,,,,J0202-012,
97,J0HTM10AP001YB04,廢水出水泵B變頻器風(fēng)機(jī)停止,DO,,USER,,,"NO
220VAC",,,,,J0202-012,
98,J0HTM10AP001XB01,廢水出水泵B變頻器準(zhǔn)備就緒,DI,,DCS,,,,,,,,J0202-012,
99,J0HTM10AP001XB02,廢水出水泵B變頻器運(yùn)行狀態(tài),DI,,DCS,,,,,,,,J0202-012,
100,J0HTM10AP001XB03,廢水出水泵B遠(yuǎn)方/就地,DI,,DCS,,,,,,,,J0202-012,
101,J0HTM10AP001XB04,廢水出水泵B
溫馨提示
- 1. 本站所有資源如無(wú)特殊說(shuō)明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請(qǐng)下載最新的WinRAR軟件解壓。
- 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請(qǐng)聯(lián)系上傳者。文件的所有權(quán)益歸上傳用戶(hù)所有。
- 3. 本站RAR壓縮包中若帶圖紙,網(wǎng)頁(yè)內(nèi)容里面會(huì)有圖紙預(yù)覽,若沒(méi)有圖紙預(yù)覽就沒(méi)有圖紙。
- 4. 未經(jīng)權(quán)益所有人同意不得將文件中的內(nèi)容挪作商業(yè)或盈利用途。
- 5. 人人文庫(kù)網(wǎng)僅提供信息存儲(chǔ)空間,僅對(duì)用戶(hù)上傳內(nèi)容的表現(xiàn)方式做保護(hù)處理,對(duì)用戶(hù)上傳分享的文檔內(nèi)容本身不做任何修改或編輯,并不能對(duì)任何下載內(nèi)容負(fù)責(zé)。
- 6. 下載文件中如有侵權(quán)或不適當(dāng)內(nèi)容,請(qǐng)與我們聯(lián)系,我們立即糾正。
- 7. 本站不保證下載資源的準(zhǔn)確性、安全性和完整性, 同時(shí)也不承擔(dān)用戶(hù)因使用這些下載資源對(duì)自己和他人造成任何形式的傷害或損失。
最新文檔
- 2025江蘇揚(yáng)州市高郵市農(nóng)文旅產(chǎn)業(yè)投資集團(tuán)有限公司招聘2人參考筆試題庫(kù)及答案解析
- 2026廣西梧州市中小學(xué)(幼兒園)公開(kāi)招聘專(zhuān)任教師321人(梧州學(xué)院專(zhuān)場(chǎng))參考考試題庫(kù)及答案解析
- 江西數(shù)引網(wǎng)絡(luò)科技有限公司招聘參考筆試題庫(kù)及答案解析
- 2025福建廈門(mén)外代航運(yùn)發(fā)展有限公司船務(wù)部社會(huì)招聘參考筆試題庫(kù)及答案解析
- 2025深圳九州光電子技術(shù)有限公司招聘包裝工程師1人備考筆試題庫(kù)及答案解析
- 2025甘肅平?jīng)鍪兄写罂萍技脊W(xué)校招聘20人備考筆試試題及答案解析
- 2025浙江海正藥業(yè)招聘?jìng)淇脊P試題庫(kù)及答案解析
- 2025廣西來(lái)賓市忻城縣城鎮(zhèn)公益性崗位人員招聘1人備考考試題庫(kù)及答案解析
- 2026年住宅小區(qū)消防管理協(xié)議
- 2026年紅河州開(kāi)遠(yuǎn)市教體系統(tǒng)事業(yè)單位校園招聘(23人)參考考試題庫(kù)及答案解析
- 《鈉離子電池原理與應(yīng)用》課件
- 資產(chǎn)管理 文化數(shù)字資產(chǎn)交易實(shí)施指南 征求意見(jiàn)稿
- 14-1《促織》(說(shuō)課稿)-2024-2025學(xué)年高一語(yǔ)文下學(xué)期同步教學(xué)說(shuō)課稿專(zhuān)輯(統(tǒng)編版必修下冊(cè))
- 【蘇教版】2023-2024學(xué)年一年級(jí)上冊(cè)科學(xué)期末測(cè)試卷5
- 【不詳】品類(lèi)創(chuàng)新:成為第一的終極戰(zhàn)略
- 《大中型無(wú)刷勵(lì)磁發(fā)電機(jī)組主勵(lì)磁機(jī)保護(hù)技術(shù)導(dǎo)則》
- 內(nèi)蒙古包頭市昆都侖區(qū)2023-2024學(xué)年七年級(jí)上學(xué)期期末調(diào)研檢測(cè)數(shù)學(xué)試卷(含解析)
- 數(shù)字經(jīng)濟(jì)學(xué)-教案全套 唐要家
- DB11T 1613-2019 非居民用燃?xì)庥?jì)量系統(tǒng)設(shè)計(jì)施工驗(yàn)收規(guī)范
- 廣州數(shù)控GSK 980TDc車(chē)床CNC使用手冊(cè)
- 《進(jìn)一步規(guī)范管理燃煤自備電廠工作方案》發(fā)改體改〔2021〕1624號(hào)
評(píng)論
0/150
提交評(píng)論