版權(quán)說明:本文檔由用戶提供并上傳,收益歸屬內(nèi)容提供方,若內(nèi)容存在侵權(quán),請進(jìn)行舉報(bào)或認(rèn)領(lǐng)
文檔簡介
DB42Technicalspecificationforbuildingcurtainwall湖北省住房和城鄉(xiāng)建設(shè)廳湖北省市場監(jiān)督管理局I 1.3鋁合金材料 1.1鋼材、鋼制品 1.6金屬板材 1.8人造板材 1.9連接件與緊固件 8.1石材面板 l1.i一般規(guī)定 lt.1一般規(guī)定 III I7.i一般規(guī)定 I7.3鋼構(gòu)件加工 I7.5金屬面板加工 I7.7構(gòu)件組裝 I8.3構(gòu)件式幕墻安裝 I8.1單元式幕墻安裝 I8.5全玻璃幕墻安裝 I8.6點(diǎn)支承玻璃幕墻安裝 I8.7索結(jié)構(gòu)幕墻安裝 I8.8采光頂、雨篷、欄板 I8.10安全規(guī)定 V請注意本文件的某些內(nèi)容可能涉及專利。本文件的發(fā)布機(jī)構(gòu)不承擔(dān)識別專利的責(zé)任。鋒、鐘建軍、吳金濤、孫洋、周奎平、張小付曉、廖先彬、韓宇琪、傅義鐵、付軍濤、1建筑幕墻工程技術(shù)規(guī)程2345全玻璃幕墻fullglasscurtainwall肋板及其支承的面板均為玻璃的幕墻。又稱玻璃肋支承玻璃幕墻,glassribsupportedglasscurtainwall。其面板與肋板僅以結(jié)構(gòu)膠連接。3.34.1.1建筑幕墻所選用的材料應(yīng)符合國家標(biāo)準(zhǔn)、行業(yè)標(biāo)準(zhǔn)和本省有關(guān)標(biāo)準(zhǔn)的規(guī)定。64.1.2幕墻材料應(yīng)滿足安全性、耐久性、環(huán)境保護(hù)和防火要求。4.1.3幕墻主要材料應(yīng)具有產(chǎn)品合格證、質(zhì)量保證書及相關(guān)性能檢測報(bào)告。4.2.1玻璃的強(qiáng)度設(shè)計(jì)值應(yīng)按JGJ113的規(guī)定采用,部分?jǐn)?shù)表1玻璃的強(qiáng)度設(shè)計(jì)值fg976765和抗彎f抗剪fv抗壓和抗彎fu,haz抗剪fv,haz局部承壓fcb≤10≤10抗拉、抗壓、抗彎f抗剪fv端面承壓(刨平頂緊)fced≤16d≤1672抗拉、抗壓、抗彎f抗剪fv端面承壓(磨平頂緊)fce4.2.5耐候鋼的強(qiáng)度設(shè)計(jì)值可按表5采用。2抗拉強(qiáng)度f抗剪強(qiáng)度fv承壓強(qiáng)度fce≤16≤16≤16≤16>60≤6>6≤6>6≤6>6≤6>6≤6>6≤2.5≤2.5≤2.584.2.6張拉桿、索的抗拉強(qiáng)度設(shè)計(jì)值按下列規(guī)定采用:a)高強(qiáng)鋼絞線或不銹鋼絞線的抗拉強(qiáng)度設(shè)計(jì)值應(yīng)按其極限抗拉承載力標(biāo)準(zhǔn)值除以系數(shù)2.0c)拉桿的抗拉強(qiáng)度設(shè)計(jì)值應(yīng)按其極限抗拉承載力標(biāo)準(zhǔn)值除以系數(shù)1.7采用。4.2.7不銹鋼抗拉、抗壓強(qiáng)度設(shè)計(jì)值fs可按其屈服強(qiáng)度標(biāo)準(zhǔn)值σ0.2除以系數(shù)1.15采用,抗剪強(qiáng)度設(shè)計(jì)值fvs可按抗拉強(qiáng)度設(shè)計(jì)值的0.58倍采用,部分?jǐn)?shù)據(jù)摘錄如下,見表6。2縱向/橫向應(yīng)變標(biāo)準(zhǔn)值f0.2強(qiáng)度fu抗彎強(qiáng)度f強(qiáng)度fv強(qiáng)度fce采用,抗剪強(qiáng)度設(shè)計(jì)值fva1可按抗拉強(qiáng)度設(shè)計(jì)值的0.58倍采用,部分?jǐn)?shù)據(jù)摘錄如下,見表7。2規(guī)定非比例延伸應(yīng)力σp0.2抗拉強(qiáng)度fat1抗剪強(qiáng)度fav1OO4.2.9石材面板的抗彎、抗剪強(qiáng)度設(shè)計(jì)值可根據(jù)其彎曲強(qiáng)度試驗(yàn)的平均值fgm按照表8所規(guī)定的安全fg1=fgm/Kbm········································································(1)9fg1——Kbm——石材抗彎設(shè)計(jì)材料安全系數(shù)。fg2=fgm/Kcm·········································································(2)Kcm——石材抗剪設(shè)計(jì)材料安全系數(shù)。材料強(qiáng)度安全系數(shù)Kbm材料強(qiáng)度安全系數(shù)Kcm2.154.303.607.104.308.605.704.2.10陶板抗彎、抗剪強(qiáng)度設(shè)計(jì)值可按下列公式(3)、公式(4)計(jì)算。?p1=?pm/2.00·····································?p2=?pm/10.00·······························································4.2.12硅酮結(jié)構(gòu)膠強(qiáng)度設(shè)計(jì)值按表9采用。強(qiáng)度設(shè)計(jì)值f1強(qiáng)度設(shè)計(jì)值f20.200.01ftbfvbfcbftbfvbfcbftaftbfvbfcb4.6、4.8級————————5.6級————————8.8級————————8.8級—————————————————————————————————————抗剪fvr承壓fcr———厚度或直徑d抗壓fcw抗拉和抗彎受拉ftwfvw、抗剪ffwd≤16d≤16d≤16d≤164.2.14材料的物理力學(xué)性能指標(biāo)線膨脹系數(shù)α(1/℃)0.72×1050.80×10-5~1.00×10-50.70×1052.35×10-52.06×1051.20×10-51.80×10-51.20×105~1.50×1051.80×10-52.05×1050.80×105~1.00×1050.80×1050.80×10-50.20×1050.70×10-50.81×1050.61×10-50.60×1050.60×10-50.20×1051.0×10-5~1.5×10-5ygyg25.678.50.8~2.528.026.028.020.0~24.04.3鋁合金材料厚度t≥40≥34≥65≥55≥25≥20氟碳/聚酯≥40≥15≥12≥20≥16≥25≥20厚度t—A≥9≥12≥21B≥9≥7≥16S≥6≥15≥21II級隔熱膠的規(guī)定。4.3.5與幕墻配套用鋁合金門窗型材的外觀質(zhì)量、性能要求應(yīng)符合鋁合金門窗相關(guān)標(biāo)準(zhǔn)規(guī)定。4.4鋼材、鋼制品4.4.1鋼材、鋼制品的表面不應(yīng)有裂紋、氣泡、結(jié)疤、泛銹、夾渣等,其牌號、規(guī)格、化學(xué)成分、力接承重結(jié)構(gòu)以及重要的非焊接承重結(jié)構(gòu)所采用的鋼材還應(yīng)具有彎曲試驗(yàn)的合格保證。4.4.5鋼型材表面除銹等級不應(yīng)低于Sa2.5級,并采取有效的防腐蝕措施。采用熱浸鍍鋅防腐蝕處理4.4.7不銹鋼材料宜采用奧氏體不銹鋼或奧氏體-鐵素體型雙相不銹鋼,不銹鋼材料均應(yīng)經(jīng)固溶處理。4.5玻璃4.5.1玻璃的外觀質(zhì)量和性能指標(biāo)應(yīng)符合國家標(biāo)準(zhǔn)的規(guī)定。e)中空玻璃的間隔鋁框可采用連續(xù)折彎型或插角4.5.4玻璃幕墻采用夾層玻璃時(shí),夾層玻璃宜采4.6金屬板材4.6.2鋁單板表面處理層的厚度應(yīng)滿厚度t≥32≥30≥16≥14≥40≥34≥65≥55≥25≥20氟碳/聚酯≥40≥15≥12≥20≥16≥25≥20≥2×104≥7.0≥22.0滾筒剝離強(qiáng)度下降率/%≤1010熱膨脹系數(shù)/℃-1≤4.0×10-5熱變形溫度/℃≥954.7石材板材4.7.2石材面板宜選用花崗巖,其物理性能應(yīng)滿足表20的要求。≥25≥28≥2.56≤0.40≥8.3不宜大于1.54.B人造板材7.56.24.52.00.94.9.1緊固件宜選用不銹鋼或鋁合金材料,應(yīng)符合國家標(biāo)準(zhǔn)的規(guī)定。4.9.2室外環(huán)境使用的不銹鋼緊固件4.10結(jié)構(gòu)膠與密封材料4.11防火封堵材料4.12保溫隔熱材料。4.13其他材料4.13.1玻璃支承墊塊宜采用邵氏硬4.13.2不同金屬材料接觸面設(shè)置的絕緣隔離墊片,宜采用尼龍12、耐熱的環(huán)氧樹脂玻璃纖4.13.3與單組份硅酮結(jié)構(gòu)密封膠配合使用的低發(fā)泡間隔雙面膠帶,宜具有透氣性。5.1.1建筑幕墻類型及構(gòu)造應(yīng)根據(jù)建筑物的使用功能、所處環(huán)境、立面設(shè)計(jì)、節(jié)能環(huán)保、施工技術(shù)等5.1.2建筑幕墻材料應(yīng)根據(jù)湖北省的氣候特點(diǎn)、圍護(hù)結(jié)構(gòu)耐久性、綠色環(huán)保、節(jié)能等要求確定,避免5.1.3建筑幕墻設(shè)計(jì)應(yīng)與相關(guān)專業(yè)進(jìn)行一體化設(shè)計(jì)。5.1.4建筑幕墻的分格宜與室內(nèi)布局和防火分區(qū)相協(xié)調(diào),同一塊面板不應(yīng)跨越兩個(gè)防火分區(qū)。5.1.5建筑幕墻開啟窗和通風(fēng)換氣裝置的設(shè)置及選用應(yīng)結(jié)合建筑立面、使用功能、建筑節(jié)能等要求確5.1.6開啟窗的布置和面積應(yīng)按通風(fēng)設(shè)計(jì)要求計(jì)算確定。當(dāng)開啟窗面積不滿足要求時(shí),宜采用其他的5.2.1建筑幕墻的性能等級建筑幕墻的性能等級應(yīng)根據(jù)建筑類別、使用功能、所在地的地理氣候及環(huán)境等條5.2.2建筑幕墻的抗風(fēng)壓性能抗風(fēng)壓性能應(yīng)根據(jù)幕墻工程所受的風(fēng)荷載標(biāo)準(zhǔn)值wk確定。計(jì)算風(fēng)荷載標(biāo)5.2.3建筑幕墻的層間變形性能建筑幕墻層間性能指標(biāo)值不應(yīng)小于主體結(jié)構(gòu)彈性層間位移角控5.2.4建筑幕墻的水密性能5.2.4.1水密性能設(shè)計(jì)取值按公式(5)計(jì)算。P=0.75×1000μzμswo················································μs——風(fēng)荷載體型系數(shù),取1.2;w0——),5.2.5建筑幕墻的氣密性能5.2.6建筑幕墻的熱工性能5.2.6.1建筑幕墻及采光頂?shù)臒峁ば阅軕?yīng)符合主體建筑節(jié)能設(shè)計(jì)和相關(guān)標(biāo)準(zhǔn)的要求,熱工性能指標(biāo)應(yīng)5.2.6.2非透光幕墻的傳熱系數(shù)按照其構(gòu)造組成,由各材料層熱阻相加的方法計(jì)算,并應(yīng)考慮幕墻框程冬季計(jì)算條件下幕墻型材和玻璃內(nèi)表面溫度是否低于露點(diǎn)溫度為判定依5.2.6.5玻璃幕墻層間陰影盒的玻璃面板宜采用中空玻璃。如釆用非中空玻璃,應(yīng)有防止層間玻璃及5.2.6.8幕墻與主體結(jié)構(gòu)間(除結(jié)構(gòu)連接部位外)不應(yīng)形成熱橋,并應(yīng)對跨越室內(nèi)外的金屬構(gòu)件或連接等密封。幕墻的透光與非透光部位之間的保溫構(gòu)5.2.6.9非透光開啟扇的傳熱系數(shù)應(yīng)符合透光幕墻的傳熱系數(shù)要求,并按透光面積計(jì)入窗墻比。5.2.7建筑幕墻耐撞擊性能人員流動密度大或者青少年、幼兒及老人活動的公共建筑的建筑幕墻,耐撞擊性能不應(yīng)低于GB/T5.2.8建筑幕墻光學(xué)性能5.2.8.1建筑幕墻在滿足采光、隔熱和保溫要求的同時(shí),不應(yīng)對周圍環(huán)境產(chǎn)生有害反射光的影響,并5.2.9建筑幕墻隔聲性能幕墻的隔聲性能設(shè)計(jì)應(yīng)根據(jù)建筑物的使用功能和環(huán)境條件進(jìn)行設(shè)計(jì),并應(yīng)符合GB/T31433、GB5.3.1樓層外緣無實(shí)體墻的玻璃部位應(yīng)設(shè)置防撞設(shè)施或醒目的警示標(biāo)志。設(shè)計(jì)固定護(hù)欄時(shí),護(hù)欄應(yīng)符5.3.2室內(nèi)護(hù)欄可利用幕墻立柱作為支撐結(jié)構(gòu),且應(yīng)與幕墻進(jìn)行一體化設(shè)計(jì)。5.3.4吊頂、斜幕墻朝向地面一側(cè)的脆性面板材料應(yīng)有防止破裂后整體墜落的安全措施。5.4構(gòu)造設(shè)計(jì)5.4.1建筑幕墻應(yīng)在建筑主體變形縫位置設(shè)置對應(yīng)的幕墻變形縫,需滿足防水、抗風(fēng)、隔熱保溫、氣5.4.3建筑幕墻應(yīng)采取措施防止產(chǎn)生噪聲。幕墻結(jié)構(gòu)的立柱與橫梁以螺栓連接時(shí),可設(shè)置柔性墊片,5.5幕墻防火設(shè)計(jì)5.5.2玻璃幕墻與其周邊防火分隔構(gòu)件間的縫隙、與樓板或防火隔墻外沿間的縫隙、與實(shí)體墻洞口邊5.5.3建筑幕墻的層間封堵應(yīng)符合下列規(guī)定:b)幕墻與防火墻或防火隔墻之間的空腔應(yīng)采用礦物棉等背襯材料填塞,填塞厚度不應(yīng)小于防火墻或防火隔墻的厚度;礦物棉等背襯材料表面應(yīng)覆蓋具有彈性的防火封堵材料或采用鋼質(zhì)封板進(jìn)行封堵,封板之間的縫隙應(yīng)采用具有彈性的防火封堵材料進(jìn)行5.5.4幕墻與建筑實(shí)體墻的間隙或裝飾性構(gòu)造的空腔,應(yīng)每三層設(shè)置一道水平防火封堵。當(dāng)外墻設(shè)置5.5.5幕墻面板及板后的填充材料應(yīng)釆用A級不燃材料。5.6幕墻防雷設(shè)計(jì)5.7幕墻防滲漏設(shè)計(jì)5.7.2檐口、封口板、窗臺、裝飾線條等外露構(gòu)造的水平面和采光頂、雨篷,應(yīng)設(shè)置有足夠的排水坡5.7.3女兒墻上封口為石材或金屬板時(shí),內(nèi)側(cè)宜設(shè)第二道防水層。5.7.4幕墻高出屋面的部分,宜在適當(dāng)?shù)牟课辉O(shè)置連續(xù)的防水構(gòu)造層進(jìn)行斷水,避免直接將滲漏水排6.1.1幕墻應(yīng)按照圍護(hù)結(jié)構(gòu)設(shè)計(jì)。結(jié)構(gòu)設(shè)計(jì)使用年限25年。6.1.2幕墻的支承結(jié)構(gòu)、面板與框架之間,需有一定的變形能力,以適應(yīng)主體結(jié)構(gòu)的位移;幕墻只承6.1.3結(jié)構(gòu)應(yīng)具有足夠的承載能力、剛度、穩(wěn)定性和適應(yīng)主體結(jié)構(gòu)變形的能力。應(yīng)根據(jù)傳力途徑對幕墻面板、支承結(jié)構(gòu)、連接件與錨固件等依次設(shè)計(jì)和驗(yàn)算,確保幕墻安全6.1.4幕墻結(jié)構(gòu)采用以概率理論為基礎(chǔ)的極限狀態(tài)設(shè)計(jì)方法,用分項(xiàng)系數(shù)設(shè)計(jì)表達(dá)式計(jì)算,按承載能6.1.5雙向受彎的桿件,兩個(gè)方向的撓度應(yīng)分別滿足撓度容許值要求。6.2.1風(fēng)荷載標(biāo)準(zhǔn)值應(yīng)按公式(6)計(jì)算。wk=βμzw0·········································w0——6.2.3體型復(fù)雜、周邊干擾效應(yīng)明顯或風(fēng)敏感等重要結(jié)構(gòu)宜進(jìn)行風(fēng)洞試驗(yàn)。當(dāng)風(fēng)洞試驗(yàn)結(jié)果與6.2.16.2.4建筑體型不規(guī)則,有較大凸出或凹口時(shí),應(yīng)按不規(guī)則程度將立面劃分為多個(gè)大面區(qū)和角部區(qū),6.2.5雙層面板的幕墻局部體型系數(shù)宜按下列規(guī)定采用。a)外層幕墻為封閉式的,內(nèi)層幕墻局部體型系數(shù)可按內(nèi)壓采用,外層幕墻宜按本文件6.2.1條采墻局部體型系數(shù)折減系數(shù)不宜小于0.8或通過風(fēng)洞條采用,內(nèi)層幕墻局部體型系數(shù)可按與外層幕墻相3)外層幕墻透風(fēng)率大于30%時(shí),內(nèi)層幕墻局部體型系數(shù)宜按本文件6.2.1條采用,外層幕墻局部體型系數(shù)折減系數(shù)不宜小于0.9或通過風(fēng)6.2.6樓梯、看臺、陽臺和上人屋面等的欄桿活荷載標(biāo)準(zhǔn)值,不應(yīng)小于下列規(guī)定值:6.2.7立面幕墻垂直于幕墻面的均布水平地震作用標(biāo)準(zhǔn)值可按公式(7)計(jì)算。qEk=βEαmaxGk/A····································································(7)βE——動力放大系數(shù),可取5.0;αmax——水平地震影響系數(shù)最大值,見表26.2.8平行于幕墻面的集中水平地震作用標(biāo)準(zhǔn)值可按公式(8)計(jì)算。PEk=βEαmaxGk········································································(8)βE——動力放大系數(shù),可取5.0;αmax——水平地震影響系數(shù)最大值,見表26度7度8度多遇地震αmax0.046.3作用效應(yīng)組合6.3.1幕墻支承結(jié)構(gòu)可按彈性方法計(jì)算,計(jì)算模型應(yīng)與實(shí)際受力狀況一致。6.3.3幕墻構(gòu)件承載力極限狀態(tài)設(shè)計(jì)基本組合的效應(yīng)設(shè)計(jì)值按公式(9)中最不利值確定。(9)Sd——作用效應(yīng)組合的設(shè)計(jì)值;S(*)——作用組合的效應(yīng)函數(shù);P——預(yù)應(yīng)力作用的有關(guān)代表值;YQj——第j個(gè)可變作用的分項(xiàng)系數(shù);6.3.4當(dāng)作用和作用效應(yīng)按線彈性方法計(jì)算時(shí),幕墻構(gòu)件承載力極限狀態(tài)設(shè)計(jì)的作用效應(yīng)設(shè)計(jì)值可按a)非地震設(shè)計(jì)狀況。Sd——作用效應(yīng)組合的設(shè)計(jì)值;YQj——第j個(gè)可變作用的分項(xiàng)系數(shù);k··············································Sd——作用效應(yīng)組合的設(shè)計(jì)值;SGE——重力荷載代表值的效應(yīng);Yw——風(fēng)荷載分項(xiàng)系數(shù);6.3.5幕墻構(gòu)件的承載力設(shè)計(jì),作用(效應(yīng))分項(xiàng)系數(shù)按下列規(guī)定取值:不利時(shí)取值1.3;當(dāng)其作用效應(yīng)對承載力有利時(shí)取值1.0;G,當(dāng)其作用效應(yīng)對承載力不利時(shí)取值1.3;當(dāng)其作用效應(yīng)對承載力有利時(shí)取值不應(yīng)大于1.0。地震作用分項(xiàng)系數(shù)YE,取值1.4,風(fēng)荷載分項(xiàng)系數(shù),取值1.5。6.3.6可變作用的組合值系數(shù)按下列規(guī)定采用:a)非地震設(shè)計(jì)狀況下,當(dāng)風(fēng)荷載效應(yīng)起控制作用時(shí),風(fēng)荷載組合值系數(shù)Ψw取1.0,活荷載或雪荷載作用組合值系數(shù)ΨL取0.7,溫度作用組合值系數(shù)ΨT取0.6;當(dāng)活荷載或雪荷載效應(yīng)起控值系數(shù)ΨL取0.7,風(fēng)荷載組合值系數(shù)Ψw取0.6;b)地震設(shè)計(jì)狀況下,風(fēng)荷載組合值系數(shù)Ψw取0.2。6.4支承結(jié)構(gòu)的撓度容許值6.4.1幕墻結(jié)構(gòu)受彎構(gòu)件的撓度應(yīng)按照荷載的標(biāo)準(zhǔn)組合計(jì)算,最大撓度值不應(yīng)超過表23規(guī)定的撓度———L/45————6.5連接設(shè)計(jì)6.5.1幕墻支承結(jié)構(gòu)構(gòu)件采用螺栓、螺釘、自攻螺釘或銷釘連接的,每個(gè)節(jié)點(diǎn)的緊固件數(shù)量不應(yīng)少于6.5.2支承結(jié)構(gòu)構(gòu)件的受拉連接不應(yīng)采用自攻螺釘和鉚釘。6.5.3主要受力構(gòu)件的連接不應(yīng)采用鋁質(zhì)抽芯鉚釘。6.5.4受力的鋼墊片應(yīng)采用焊接形式進(jìn)行固定,墊片厚度及焊縫應(yīng)經(jīng)計(jì)算確定。6.5.5采用螺紋受力連接時(shí),應(yīng)進(jìn)行承載力計(jì)算。螺紋連接部位的鋁型材截面厚度不宜小于螺釘公稱6.6埋件的設(shè)計(jì)與構(gòu)造6.6.4幕墻用后置埋件設(shè)計(jì)計(jì)算宜采用開裂混凝土的假定。6.6.5對于幕墻雨篷、抗風(fēng)柱等重要構(gòu)件,宜采用預(yù)埋件,無預(yù)埋件時(shí),后置埋件應(yīng)采用機(jī)械自擴(kuò)底6.6.6群錨錨栓應(yīng)采用同品牌、同類型和同規(guī)格的錨栓。6.6.7后錨固連接除按規(guī)定計(jì)算外,尚應(yīng)經(jīng)現(xiàn)場拉拔試驗(yàn)確定其承載能力。6.6.8平板埋件、槽式埋件、板槽埋件、后置埋件的設(shè)計(jì)與構(gòu)造等詳見附錄A。6.7硅酮結(jié)構(gòu)密封膠密封膠的拉應(yīng)力或剪應(yīng)力設(shè)計(jì)值不應(yīng)大于其長期荷載作用下的強(qiáng)度設(shè)6.7.3四邊支承的隱框、半隱框玻璃幕墻中,玻璃和鋁框之間硅酮結(jié)構(gòu)密封膠的粘接寬度cs,應(yīng)根據(jù)a)在風(fēng)荷載作用下,粘接寬度cs應(yīng)按公式(12)計(jì)算。············································b)在風(fēng)荷載和地震作用下,粘接寬度應(yīng)按公式(13)計(jì)算。6.7.4外傾或倒掛的半隱框幕墻,隱框邊玻璃和鋁框之間硅酮結(jié)構(gòu)密封膠的粘接寬度cs應(yīng)分別按照下a)在永久作用和風(fēng)荷載作用下,粘接寬度cs應(yīng)按公式(14)計(jì)算?!ぁぁぁぁぁぁぁぁぁぁぁぁぁぁぁぁぁぁぁぁぁぁぁぁぁぁぁぁぁぁぁぁぁぁぁぁぁぁぁぁぁぁぃ?;b)在永久作用下,粘接寬度應(yīng)按公式(15)計(jì)算?!ぁぁぁぁぁぁぁぁぁぁぁぁぁぁぁぁぁぁぁぁぁぁぁぁぁぁぁぁぁぁぁぁぁぁぁぁぁぁぁぁぁぁぁぃ?;6.7.5結(jié)構(gòu)膠的厚度可按照6.7.6和6.7.7分別計(jì)算吸收熱膨脹位移需要的厚度和吸收結(jié)構(gòu)層間位移6.7.6幕墻面板通過硅酮結(jié)構(gòu)密封膠與型材粘接時(shí),硅酮結(jié)構(gòu)密封膠吸收熱膨脹位移需要的厚度不應(yīng)αc——金屬框的線膨脹系數(shù)(1/℃);αv——面板的線膨脹系數(shù)(1/℃);ΔT——面板和金屬框相對結(jié)構(gòu)膠施工時(shí)的溫度差,取面板和金屬框相對溫差的較大值(℃);6.7.7依靠結(jié)構(gòu)膠變位能力來適應(yīng)層間位移的玻璃幕墻,硅酮結(jié)構(gòu)密封膠的厚度(圖1)應(yīng)按下列公··············································η——位移折減系數(shù),取值0.60;=ηη1——位移折減系數(shù),取值0.80;θ——主體結(jié)構(gòu)側(cè)移時(shí),面板的轉(zhuǎn)動角;),6.7.8隱框玻璃幕墻玻璃面板的結(jié)構(gòu)膠寬度cs和厚度ts尺寸及配合尺寸見圖2和圖3。隱框中空玻璃的結(jié)構(gòu)膠寬度cs1應(yīng)按中空玻璃外片所受荷載計(jì)算確定。···············································7.2.1構(gòu)件設(shè)計(jì)框支承結(jié)構(gòu)構(gòu)件截面寬厚比不滿足本文件10.2.1.1條時(shí)應(yīng)進(jìn)行截面局部穩(wěn)定性驗(yàn)算。7.2.2橫梁結(jié)構(gòu)設(shè)計(jì)7.2.2.1橫梁截面受彎承載力應(yīng)符合公式(22)。f——型材的強(qiáng)度設(shè)計(jì)值fa或fs(N/mm2)。7.2.2.2橫梁截面受剪承載力應(yīng)符合公式(23公式(24)?!躥v···········································································(23)≤fv···········································································(24)7.2.2.3當(dāng)面板偏置或外挑裝飾件等原因使橫梁產(chǎn)生較大扭矩時(shí),應(yīng)進(jìn)行橫梁抗扭承載力計(jì)算。7.2.2.4橫梁撓度驗(yàn)算時(shí),水平荷載與豎向荷載應(yīng)分別計(jì)算,并滿足限值要求。7.2.3立柱結(jié)構(gòu)設(shè)計(jì)7.2.3.1承受軸向拉力和彎矩作用的立柱,其承載力應(yīng)符合公式(25)。 N+M≤f·······································································(25)AnYWnW);············································λ——立柱長細(xì)比;E——立柱彈性模量;β——材料系數(shù),鋁型材取1.2,鋼材取1.1。λ=································································λ——立柱長細(xì)比;式立柱l=2L,L為立柱支承長度;ff2400.900.950.970.960.950.940.730.820.900.860.890.870.510.580.810.730.820.780.340.380.690.580.720.630.280.310.620.500.660.550.230.250.560.430.590.480.200.210.490.370.520.410.170.180.440.320.450.35表24軸心受壓柱的穩(wěn)定系數(shù)φ(續(xù))0.150.130.110.160.140.120.390.350.310.280.250.210.400.350.310.300.260.23注:f0.2——鋁合金材料的規(guī)定非比例伸長應(yīng)力,也稱名義屈服強(qiáng)度。7.2.3.3框支承幕墻立柱長細(xì)比λ應(yīng)滿足下列規(guī)定:a)承受軸向壓力和彎矩作用時(shí),鋁型材長細(xì)比λ不宜大于150;單根型7.2.3.4框支承幕墻立柱為組合構(gòu)件時(shí),立柱的荷載分配原則如下?!ぁぁぁぁぁぁぁぁぁぁぁぁぁぁぁぁぁぁぁぁぁぁぁぁぁぁぁぁぁぁぁぁぁぁぁぁぁぁぁぁぁぁぁぁぁぁぁぁぁぁぁぁぁぁぁぁぁぁぁぁぁぁぁぁぁぁぁぁぁぁぁぁぁぁぁぁぁぁぁぁぁぁぁぁぁ2k——b)無確保左、右立柱協(xié)同變形的構(gòu)造措施時(shí),應(yīng)根據(jù)各自承擔(dān)的荷載及作用計(jì)算。7.2.3.5鋼鋁組合截面立柱設(shè)計(jì)原則如下。a)鋼鋁共同工作的組合截面可按剛度分配原理,分別按公式(31公式(32)計(jì)算F——調(diào)整系數(shù),取1.05。7.3玻璃肋···········································7.3.2全玻璃幕墻玻璃肋在風(fēng)荷載標(biāo)準(zhǔn)值作用下的撓度df可按公式(34)計(jì)算。df——風(fēng)荷載標(biāo)準(zhǔn)值作用引起的幕墻構(gòu)件撓度值;7.3.4玻璃肋采用玻璃孔內(nèi)螺栓傳遞荷載時(shí),應(yīng)計(jì)算螺栓受剪和玻璃孔壁承壓,同時(shí)應(yīng)驗(yàn)算孔內(nèi)填充7.3.5玻璃孔壁承壓應(yīng)按公式(35)驗(yàn)算。N≤η1η2Dtfgd·······································································(35)),ηη2——孔加工及合片精度折減系數(shù),雙7.3.6玻璃孔內(nèi)填充材料應(yīng)按公式(35)驗(yàn)算抗擠壓強(qiáng)度,fgd取填充材料抗擠壓強(qiáng)度設(shè)計(jì)值,D取螺7.3.7玻璃肋采用植入金屬連接件的夾層玻璃時(shí),金屬植入連接節(jié)點(diǎn)宜進(jìn)行試驗(yàn)驗(yàn)證或有限元分析,有限元分析中玻璃的最大主拉應(yīng)力值不應(yīng)超過玻璃強(qiáng)度7.4.6索結(jié)構(gòu)節(jié)點(diǎn)應(yīng)滿足其承載力設(shè)計(jì)值不小于拉索內(nèi)力設(shè)計(jì)值1.25倍的要求。7.4.7索結(jié)構(gòu)應(yīng)分別對初始預(yù)應(yīng)力及荷載作用做計(jì)算分析,計(jì)算應(yīng)考慮幾何非線性影響。在任何荷載7.4.8荷載狀態(tài)分析應(yīng)在初始預(yù)應(yīng)力狀態(tài)的基礎(chǔ)上,考慮永久荷載、風(fēng)荷載、地震作用、溫度作用、7.4.9索結(jié)構(gòu)計(jì)算模型宜考慮與主體支承結(jié)構(gòu)的相互影響。7.4.11索桿桁架受壓桿件長細(xì)比λ不宜大于17.4.12單索支承的邊跨玻璃面板與主體結(jié)構(gòu)之間的連接構(gòu)造應(yīng)能適應(yīng)風(fēng)荷載作用下索及玻璃的變形7.4.13拉索和拉桿的抗拉力設(shè)計(jì)值按公式(36)計(jì)算。F=Ftk/YR·········································································(36)FR——抗力分項(xiàng)系數(shù),拉索取2.0,拉桿取1.7。Y0Nd<F········································································0——結(jié)構(gòu)重要性系數(shù),一般取1.0。8.1一般規(guī)定8.1.1面板與幕墻支承結(jié)構(gòu)的連接,應(yīng)能滿足荷載作用所產(chǎn)生的幕墻平面內(nèi)和平面外的變形要求。8.1.2面板設(shè)計(jì)應(yīng)考慮加工制作、運(yùn)輸、安裝、維護(hù)和更換的要求。8.1.3面板的撓度限值應(yīng)符合表25的規(guī)定。表25面板的撓度限值df,lim表25面板的撓度限值df,lim(續(xù))———8.2.1幕墻所用玻璃應(yīng)選用鋼化玻璃、夾層玻璃及其制品;鋼化玻璃宜采用超白鋼化玻璃或經(jīng)均質(zhì)處8.2.3中空玻璃各層玻璃分配到的荷載應(yīng)按照各自等效剛度的比例進(jìn)行分配。在進(jìn)行強(qiáng)度校核時(shí),中··········································),8.2.4由多片玻璃組成的玻璃面板,計(jì)算玻璃平面外剛度時(shí),等效厚度計(jì)算方法如下?!ぁぁぁぁぁぁぁぁぁぁぁぁぁぁぁぁぁぁぁぁぁぁぁぁぁぁぁぁぁぁぁぁぁぁぁぁぁぁぁぁぁぁぁぁ)離子型膠片夾層玻璃在計(jì)算撓度時(shí),等效厚度te,w可按公式Γ——離子型夾膠片的剪力傳遞系數(shù)。tΓ——離子型夾膠片的剪力傳遞系數(shù)。tΓ——離子型夾膠片的剪力傳遞系數(shù)。t,1·········································································································v······································);8.2.5四邊支承玻璃在垂直于玻璃幕墻平面的風(fēng)荷載和地震作用下的最大應(yīng)力標(biāo)準(zhǔn)值。跨中最大應(yīng)力設(shè)計(jì)值不應(yīng)超過玻璃中部強(qiáng)度a/b0.010.250.330.400.500.550.600.65ma/b0.700.750.800.850.900.95—m—表27折減系數(shù)ηθ≤5η0.960.920.840.780.730.68θη0.650.610.570.540.520.510.50b)最大應(yīng)力設(shè)計(jì)值應(yīng)按本文件6.3節(jié)的規(guī)定組合。c)跨中最大應(yīng)力設(shè)計(jì)值不應(yīng)超過玻璃中部強(qiáng)度設(shè)計(jì)值。8.2.6四邊支承玻璃在風(fēng)荷載作用下的跨中撓度,可按公·········································),a/b0.000.200.250.330.50μa/b0.550.600.650.700.75μa/b0.800.850.900.95μ8.2.7在垂直于幕墻平面的風(fēng)荷載和地震作用下,四點(diǎn)支承玻璃面板的應(yīng)力和撓度可按本文件8.2.5~8.2.6條文中的公式計(jì)算,但此處應(yīng)注意其字符含義。η——折減系數(shù),按本文件表27采用,計(jì)算θ時(shí),此處公式中的a取支承點(diǎn)間玻璃面板長邊邊長;孔邊最大應(yīng)力設(shè)計(jì)值不應(yīng)超過玻璃邊緣強(qiáng)度設(shè)計(jì)值,跨中最大應(yīng)力設(shè)計(jì)值不應(yīng)超過玻璃中部強(qiáng)度φ0.000.200.300.400.500.550.600.65mφ0.700.750.800.850.900.95—m—φ0.000.200.300.400.500.550.600.65μφ0.700.750.800.850.900.95—μ—8.2.8玻璃面板也可采用非線性有限元方法分析計(jì)算。8.2.10玻璃上開孔時(shí),孔邊至玻璃邊距離不應(yīng)小于單片玻璃厚度的4倍和孔徑的8.3.1面板的厚度應(yīng)通過計(jì)算確定,弧形及異型板宜采用幾何非線性的有限元方法計(jì)算確定;單層鋁8.3.2金屬平板四邊支承面板彎曲應(yīng)力可按下列規(guī)定進(jìn)行計(jì)算。a)折邊和肋所形成的面板區(qū)格,沿板材四周邊緣按簡支邊計(jì)算,中肋支承線按固定邊計(jì)算。)~·····················································································c)中肋支承線上的彎曲應(yīng)力標(biāo)準(zhǔn)值,取板格兩側(cè)固端彎矩的平均值計(jì)算。η(η按表31采用)。表31折減系數(shù)ηθ5η0.950.900.810.740.690.64θη0.610.540.500.460.430.410.408.3.3金屬平板在組合荷載作用下,單向肋面板區(qū)格的跨中撓度可采用幾何非線性有限元方法計(jì)算,··················································································8.3.4金屬平板采用雙向肋面板區(qū)格形式時(shí),按實(shí)際受力形式計(jì)算;宜采用有限元分析計(jì)算。8.3.5中肋應(yīng)有足夠的剛度。在組合荷載標(biāo)準(zhǔn)值作用下,中肋與面板撓度的限值df,lim宜按板的短邊8.3.6金屬面板加勁肋的設(shè)置和連接構(gòu)造應(yīng)經(jīng)計(jì)算確定,并符合下列規(guī)定:a)采用8.3.3中的公式(56)~公式(57)進(jìn)行計(jì)算時(shí),面板折邊與加勁肋端部應(yīng)可b)加勁肋與金屬面板背面連接可采用焊接螺柱固定或硅酮結(jié)構(gòu)密封膠粘接,焊接螺柱相鄰間距8.4石材面板8.4.3面板與支承結(jié)構(gòu)的連接應(yīng)便于更換,不應(yīng)采用鋼銷、T形插板、蝶8.4.4面板采用短槽支承、背栓支承連接時(shí),應(yīng)按四點(diǎn)支承板設(shè)計(jì)及計(jì)算,并符合下列要求:8.4.5面板采用對邊通槽連接時(shí),按對邊簡支板模型計(jì)算,面板跨度為兩支承邊之間的距離。8.4.6異形板或多點(diǎn)支承面板按有限元方法計(jì)算。8.4.7面板抗彎設(shè)計(jì)應(yīng)符合下列規(guī)定。)~··················································································)~···························································································································(v=0.125)a/b0.500.550.600.650.700.75ma/b0.800.850.900.95—m—d)面板中最大彎曲應(yīng)力標(biāo)準(zhǔn)值按本文件6.3節(jié)規(guī)定組合,所得的最大彎曲應(yīng)力設(shè)計(jì)值不應(yīng)超過8.4.8通槽支承面板的槽口抗彎設(shè)計(jì)應(yīng)符合下列規(guī)定。············································σk——c)面板槽口處最大彎曲應(yīng)力設(shè)計(jì)值σ滿足下列公式(65)要求。σ≤0.7fg1··········································································(65)fg1——8.4.9短槽和通槽面板抗剪設(shè)計(jì)應(yīng)符合下列規(guī)定。a)短槽面板在風(fēng)荷載或垂直于板面方向地震作用下,掛鉤在槽口邊產(chǎn)生的剪應(yīng)力標(biāo)準(zhǔn)值按公式)~τk——τk——·············································τk——c)由各種載荷和作用產(chǎn)生的剪應(yīng)力標(biāo)準(zhǔn)值按本文件6.3節(jié)規(guī)定組合,剪應(yīng)力設(shè)計(jì)值468β8.4.10背栓面板抗拉設(shè)計(jì)應(yīng)符合下列規(guī)定。a)在風(fēng)荷載或垂直于板面方向地震作用下,單個(gè)背栓螺栓所受拉力按下列公式(69)計(jì)算。·········································c)受拉時(shí)單個(gè)背栓螺栓承載力設(shè)計(jì)值Rt應(yīng)通過荷載試驗(yàn)確定,材料強(qiáng)度系數(shù)取2.5~3.0,所得···········································);d)小尺寸面板或條狀面板,背栓位置不滿足8.4.16條要求時(shí),背栓中心線至面板邊緣距離不宜e)背栓螺栓應(yīng)按凈面積驗(yàn)算抗拉承載力并滿足強(qiáng)度要求。8.4.11背栓面板抗剪設(shè)計(jì)應(yīng)符合下列規(guī)定。τk——負(fù)壓時(shí))···············τk——);τ≤fg2············································································(73)c)背栓螺栓處于本文件8.4.10條d)款所述位8.4.12面板的支承連接構(gòu)造,可采用短槽、通槽和背栓形式,同一塊面板上可有不同的連接構(gòu)造。8.4.13應(yīng)根據(jù)面板的尺寸、材質(zhì)、厚度、形狀和所在位置等合理選擇連接方式。8.4.14石材掛件材質(zhì)應(yīng)采用不銹鋼和鋁合金,不應(yīng)采用碳鋼。8.4.15短槽/通槽連接構(gòu)造應(yīng)滿足下列要求:8.4.16背栓孔切入的有效深度不宜小于面板厚度1/2,也不宜大于石8.5人造面板8.5.1幕墻用人造面板的適用高度見表34。高度(≤)8.5.2人造面板應(yīng)按實(shí)際受力模型計(jì)算。8.5.3空心陶板的最大彎曲應(yīng)力標(biāo)準(zhǔn)值宜采用有限元方法分析計(jì)算,也可通過均布靜態(tài)荷載彎曲試驗(yàn)··············································q——垂直于空心陶板板面方向的風(fēng)荷載標(biāo)準(zhǔn)值和地震作用標(biāo)準(zhǔn)值,按本文件6.3節(jié)規(guī)定進(jìn)行組合r——陶板的材料性能分項(xiàng)系數(shù),可取1.8。8.5.4異型面板可采用有限元方法計(jì)算。8.5.6人造面板最小厚度應(yīng)符合表35規(guī)定。面板材料選用應(yīng)符合相關(guān)規(guī)范要求。88.5.7面板的計(jì)算厚度分別為:按公稱厚度減去背紋厚度和表面凸起高度或凹陷8.6復(fù)合面板8.6.1鋁塑復(fù)合板和構(gòu)造相似的其他金屬復(fù)合板可采用刻槽折邊,刻槽不應(yīng)觸及面層金屬板,刻槽后8.6.4石材蜂窩復(fù)合板的錨固螺栓應(yīng)在工廠制作板材時(shí)埋入,不應(yīng)現(xiàn)場埋置。粘結(jié)填嵌的材料應(yīng)與粘8.6.7復(fù)合面板的加勁肋的設(shè)置和連接應(yīng)經(jīng)計(jì)算確定。加勁肋應(yīng)與面板和邊框可靠連結(jié)。8.6.8復(fù)合面板的面板計(jì)算應(yīng)符合下列規(guī)定。b)復(fù)合金屬板的抗彎強(qiáng)度設(shè)計(jì)值可根據(jù)面板與背板的鋁板牌號及合金狀態(tài)確定。)~),·········································),wkte——面板的折算厚度,鋁塑復(fù)合板可取0.8t,蜂窩鋁板可取0.6t;45622.02.7456De2.4×1054.0×1055.9×105表38鋁蜂窩復(fù)合板的等效截面模量We24.524.0表39鋁蜂窩復(fù)合板的等效彎曲剛度DeDe0.2×1070.7×1071.3×1072.2×1078.6.9垂直于面板風(fēng)荷載、地震作用下,金屬和鋁蜂窩復(fù)合板的面板跨中撓度可采用幾何非線性有限···········································););2.0m2,外開窗應(yīng)有防止窗扇脫落的措施。通風(fēng)換氣用幕墻開啟窗不應(yīng)采用外平開窗。9.1.4開啟窗框、窗扇、五金件及連接,應(yīng)進(jìn)行承載力的驗(yàn)算。9.1.5開啟窗窗扇不應(yīng)采用全隱框形式。必要時(shí)窗扇應(yīng)增加安全連接構(gòu)造,并進(jìn)行單獨(dú)承載驗(yàn)算。對容易滲入雨水或形成冷凝水的部位,宜在構(gòu)造上設(shè)置導(dǎo)排水措9.2.2開啟窗的窗框、窗扇的角部接縫處應(yīng)采用可靠的密封措施。窗膠條周圈宜連續(xù),轉(zhuǎn)角部位宜連9.2.3開啟窗周邊用密封條應(yīng)采用氯丁橡膠、三元乙丙橡膠條或硅橡膠密封條等制品,其性能應(yīng)符合9.2.5上懸窗采用懸掛式連接時(shí),窗扇擠角組角連接應(yīng)進(jìn)行承載力驗(yàn)算。9.2.6開啟窗五金件型號應(yīng)根據(jù)設(shè)計(jì)荷載選定,其連接承載力應(yīng)滿足使用要求。9.2.7開啟窗采用不銹鋼滑撐時(shí),滑撐應(yīng)按開啟窗的自重和要求確定型號、規(guī)格,其性能應(yīng)符合9.2.8開啟窗采用不銹鋼撐檔時(shí),撐檔應(yīng)按開啟扇的面積和要求確定型號、規(guī)格,其性能應(yīng)符合9.2.9開啟窗采用執(zhí)手、鎖閉器時(shí),應(yīng)按開啟窗的面積、功能及要求確定型號、規(guī)格,其性能應(yīng)符合本文件10.1.6條規(guī)定。夾層玻璃、中空玻璃外露端面宜有防護(hù)措施。10.1一般規(guī)定10.1.3起密封作用的明框玻璃外壓板應(yīng)與接縫等長。面板厚度tabc6≥3.5≥15≥5≥4.5≥16≥5≥5.5≥18≥5面板總厚度tabct≤24≥5≥17≥7≥5≥5≥6≥18≥7≥5≥510.2構(gòu)造設(shè)計(jì)10.2.1橫梁構(gòu)造設(shè)計(jì)10.2.1.1橫梁截面主要受力部位的厚度應(yīng)符合下列規(guī)定:10.2.2立柱構(gòu)造設(shè)計(jì)10.2.2.1立柱截面主要受力部位的厚度應(yīng)符合下列規(guī)定:10.2.3單元式幕墻構(gòu)造設(shè)計(jì)10.2.3.1單元式幕墻的構(gòu)造應(yīng)形成2道或以上連續(xù)的密封線,保證水密、氣密性能。10.2.3.2單元式幕墻板塊間的對插部位,鋁型材宜有導(dǎo)插構(gòu)造。10.2.3.4單元式幕墻面材與框架及框架與框架連接處,應(yīng)有可靠的t——幕墻的年溫度變化(K10.3連接設(shè)計(jì)10.3.4構(gòu)件式幕墻上、下立柱的連接構(gòu)造應(yīng)符合下列要求:10.3.5單元式幕墻框架立柱和橫梁的連接,應(yīng)采用不銹鋼自攻螺釘或機(jī)制螺釘,且應(yīng)采取密封11.1.1玻璃肋應(yīng)采用夾層玻璃,開孔玻璃肋應(yīng)采用鋼化夾層玻璃。11.2構(gòu)造設(shè)計(jì)12.1一般規(guī)定構(gòu)的一部分;復(fù)雜的支承結(jié)構(gòu)宜采用有限元方法12.1.2穿孔式點(diǎn)支承裝置的駁接頭應(yīng)能適應(yīng)玻璃面板在支承點(diǎn)處的轉(zhuǎn)動變形。夾板式點(diǎn)支承裝置的12.2支承裝置構(gòu)造設(shè)計(jì)13.1.3采光頂上有消防要求的開啟天窗應(yīng)與消防系統(tǒng)聯(lián)動。13.1.4傾斜面采光頂檐口直接臨街或下方為人流聚集區(qū)時(shí),應(yīng)設(shè)置融雪、擋冰裝置。13.1.5采光頂應(yīng)有防止玻璃墜落的構(gòu)造措施。排水時(shí),雨水主水管應(yīng)采取暗藏形式;無組織排水時(shí),應(yīng)避免主要出入口出現(xiàn)水簾現(xiàn)象。13.1.7倒置式玻璃雨篷不應(yīng)采用隱框或點(diǎn)支承的構(gòu)造設(shè)計(jì)。13.1.9出入口、人行通道的雨篷應(yīng)有防止玻璃墜落的構(gòu)造措施。13.2結(jié)構(gòu)設(shè)計(jì)a)懸挑雨篷負(fù)風(fēng)壓體型系數(shù)取-2.0;13.2.5釆光頂、雨篷支承構(gòu)件及面板的最大撓度應(yīng)13.3.2采光頂宜有冷凝水和滲漏水的收集導(dǎo)排系統(tǒng)。13.3.3面積較大的采光頂宜采用有組織排水系統(tǒng)。13.4構(gòu)造設(shè)計(jì)13.4.1附著于采光頂?shù)木坝^照明裝置及清洗維護(hù)裝置應(yīng)與采光頂一體化設(shè)計(jì)。14.1一般規(guī)定14.1.1光伏組件選用及電氣線路的設(shè)計(jì),應(yīng)符合國家及行業(yè)有關(guān)標(biāo)準(zhǔn)的規(guī)定。14.1.2規(guī)劃設(shè)計(jì)應(yīng)綜合考慮建筑功能、周邊環(huán)境、地區(qū)氣候及太陽能資源等因素。光伏幕墻的布局、14.1.5光伏幕墻設(shè)計(jì)應(yīng)預(yù)留光伏輸配電和控制用纜線及電氣設(shè)備的布局空間,統(tǒng)籌安排、集中布置,14.1.6光伏組件的選型和設(shè)計(jì)應(yīng)與建筑設(shè)計(jì)相協(xié)調(diào),不應(yīng)對安裝部位的建筑及幕墻造成不利影響。14.3運(yùn)行與維護(hù)15.1.2幕墻信息模型可按幕墻工程不同階段的需求進(jìn)行創(chuàng)建,并基于模型輸出相關(guān)數(shù)據(jù)信息,如二維15.2.1建模范圍應(yīng)與工程項(xiàng)目幕墻設(shè)計(jì)建造合同中約定的工作范圍一致。模型的創(chuàng)建及維護(hù)應(yīng)與幕15.2.3建模流程一般包含建模準(zhǔn)備、模型創(chuàng)建、模型校核、模型優(yōu)化及深化四個(gè)階段。15.2.5模型創(chuàng)建一般根據(jù)前期收集整理的數(shù)據(jù)材料進(jìn)行模型創(chuàng)建,模型項(xiàng)目地理位置信息、坐標(biāo)系、單位與公差等應(yīng)與設(shè)計(jì)文件一致,宜采用經(jīng)濟(jì)、便捷的建模細(xì)度準(zhǔn)確建模,精確反映幕墻構(gòu)件及相關(guān)信15.2.6幕墻設(shè)計(jì)建造不同階段對模型成果的幾何精度和信息精度的最低要求應(yīng)符合I2I3I4I515.2.6.1幕墻信息模型的規(guī)劃標(biāo)準(zhǔn)應(yīng)符合所在工程項(xiàng)目總的建筑信息模型建模規(guī)劃標(biāo)準(zhǔn)的規(guī)定。無a)單位及坐標(biāo):);2)采用建模軟件自帶的通用坐標(biāo)系,以相對標(biāo)高±0.000為坐標(biāo)原點(diǎn)的Z軸坐標(biāo)點(diǎn)。b)幕墻信息模型的拆分標(biāo)準(zhǔn)可選劃分方法:2)按幕墻系統(tǒng)類型劃分;4)按建筑立面劃分;6)按模型構(gòu)件材料劃分。c)模型及構(gòu)件命名規(guī)則:1)模型與構(gòu)件命名應(yīng)由英文字母、數(shù)字、下劃線組成;2)模型命名應(yīng)以拆分先后順序逐級命名,以體現(xiàn)模型之間的從屬關(guān)系;3)模型文件的一般命名方式為項(xiàng)目編號或項(xiàng)目簡稱__設(shè)計(jì)建造階段__建筑樓體號__幕墻系統(tǒng)編號__所在樓層號/立面號__施工區(qū)域或批次號__八位數(shù)字日期。1)對模型中的構(gòu)件依據(jù)材料的不同賦予不同顏色;e)文件夾及文件命名規(guī)則:2)除模型文件外,其他文件的命名應(yīng)按約定的規(guī)則保持文件名稱的唯一性。15.2.7模型校核主要包括以下內(nèi)容:a)模型與建模標(biāo)準(zhǔn)的匹配度校核;b)模型精度校核。應(yīng)對模型的幾何精度和信息精度分別校核;c)模型與圖紙的匹配度校核。模型碰撞問題校核。15.2.8模型優(yōu)化及深化主要包括以下內(nèi)容:d)幕墻曲面優(yōu)化應(yīng)使異形曲面幕墻的表皮分格合理,在保證圓滑過渡效果的前提下盡量減少雙f)深化模型材質(zhì)設(shè)置應(yīng)符合相關(guān)標(biāo)準(zhǔn)指定的統(tǒng)一材質(zhì)命名規(guī)則;g)構(gòu)件宜有唯一的標(biāo)識編碼,以方便確認(rèn)具體信息;h)深化模型除應(yīng)包括施工圖設(shè)計(jì)模型元素外,還應(yīng)包括節(jié)點(diǎn)、預(yù)埋件等模型元素。15.3模型應(yīng)用15.3.1基本要求15.3.2模型可視化15.3.2.1模型可視化應(yīng)簡單直接,貫穿幕墻建造的各個(gè)階段,如外15.3.2.2模型可視化宜選擇可使模型輕量化的軟件。15.3.3模型碰撞檢查15.3.3.1在方案設(shè)計(jì)階段,碰撞檢查可用于幕墻系統(tǒng)與建筑主體空間尺寸的初步確認(rèn)。15.3.3.2在深化設(shè)計(jì)階段,可通過幕墻信息模型與建筑主體設(shè)計(jì)信15.3.3.3在施工建造階段,可通過幕墻信息模型與建筑主體現(xiàn)場信15.3.4模型數(shù)據(jù)統(tǒng)計(jì)15.3.4.1在幕墻方案設(shè)計(jì)階段,可基于模型作初步工程量統(tǒng)計(jì),并15.3.4.2在幕墻深化設(shè)計(jì)階段,可基于模型作精準(zhǔn)工程量統(tǒng)計(jì),對15.3.4.3在幕墻加工組裝階段,可基于模型中輸入的加工組裝信息,對加工組裝計(jì)劃作合理安排。15.3.4.4在幕墻施工建造階段,可基于模型中輸入的安裝信息,實(shí)施資金流量分析。15.3.5施工進(jìn)度模擬15.3.5.1在方案設(shè)計(jì)階段,可基于信息模型中的施工進(jìn)度要求來選擇合理的幕墻系統(tǒng)。15.3.5.2在深化設(shè)計(jì)階段,可基于信息模型進(jìn)行幕墻及相關(guān)專業(yè)交接口的合理設(shè)計(jì)。協(xié)調(diào)施工機(jī)具及設(shè)備設(shè)施的綜合利用,以節(jié)約施工成本、提高施15.3.6施工工藝模擬15.3.7施工現(xiàn)場問題預(yù)判與協(xié)調(diào)15.3.8模型評估15.3.8.1幕墻施工完成后宜根據(jù)模型進(jìn)行評估。15.3.8.2對照實(shí)際工程完工時(shí)間與幕墻模型施工模擬進(jìn)度計(jì)劃,評15.3.8.3對照工程完工發(fā)生的實(shí)際成本與幕墻模型的預(yù)算成本,評15.3.8.4巡查完工后幕墻質(zhì)量狀態(tài),對存在的水密、氣密等質(zhì)量缺15.3.8.5對照實(shí)際完工效果與幕墻設(shè)計(jì)模型,評估幕墻建筑效果實(shí)現(xiàn)程度。15.4模型交付15.4.1模型應(yīng)滿足幕墻建造合同中約定的交付標(biāo)準(zhǔn)。不同階段所交付的成果可按15.2.5條的建模規(guī)劃標(biāo)準(zhǔn)創(chuàng)建,并符合15.5節(jié)規(guī)定的精度要15.4.2幕墻設(shè)計(jì)建造各階段交付的模型包括可編輯的源模型、可被輕量化軟件讀取的模型。15.4.3幕墻信息模型宜作為技術(shù)資料的一項(xiàng)內(nèi)容在幕墻竣工驗(yàn)收時(shí)一并交付。15.5模型精度15.5.1幕墻信息模型精度包括模型幾何精度和模型信息精度。無無無無無準(zhǔn)確外輪廓:要求構(gòu)件模型有準(zhǔn)確的外輪廓邊界,以表現(xiàn)不同構(gòu)件之間的空間關(guān)系,對構(gòu)件內(nèi)部尺寸無細(xì)節(jié)精度等級/信息類別I1I2I3I4I5有有有有有無有有有有無無有有有無無無有有無無無無有方式見表47。模型/圖紙模型/附件16.1一般規(guī)定內(nèi)同一企業(yè)同類幕墻的型式試驗(yàn)結(jié)果,但型式試驗(yàn)結(jié)16.1.2建筑幕墻工程竣工驗(yàn)收后,其可靠16.1.4雨篷、采光頂、欄桿等檢驗(yàn)檢測應(yīng)按照相應(yīng)標(biāo)準(zhǔn)執(zhí)行。16.2.1所有進(jìn)場材料均需要提供產(chǎn)品合格證、出廠檢驗(yàn)報(bào)告。16.2.4鋼材的檢驗(yàn)項(xiàng)目包括力學(xué)性能、幾何尺寸、表面質(zhì)量和防腐蝕處理等,必要時(shí)檢測化學(xué)成分。16.2.8蜂窩板的檢驗(yàn)項(xiàng)目包括正、背面金屬板厚度和剝離強(qiáng)度等。16.2.9硅酮結(jié)構(gòu)密封膠、硅酮建筑密封膠及密封材料檢驗(yàn)包括以下項(xiàng)目:16.2.11保溫材料及防火材料的檢驗(yàn)包括以下項(xiàng)目:a)保溫材料的吸水率、密度、導(dǎo)熱系數(shù);16.2.12幕墻工程應(yīng)對下列材料及其性能指標(biāo)進(jìn)行復(fù)驗(yàn):f)主受力桿件的力學(xué)性能。16.3現(xiàn)場檢測16.4性能檢測16.4.1幕墻性能相關(guān)標(biāo)準(zhǔn)規(guī)定程序檢測16.4.2對試件的技術(shù)要求16.4.2.1試件應(yīng)有足夠的尺寸和配置,且應(yīng)包括典型的垂直接縫、水平接縫和可開啟部分,試件上可開啟部分占試件總面積的比例與實(shí)際工程接近,試件應(yīng)能代表建筑幕墻典型部分的性能。16.4.2.2試件材料、規(guī)格和型號等應(yīng)與生產(chǎn)廠家所提供圖樣一致。16.4.2.3試件寬度至少應(yīng)包括一個(gè)承受設(shè)計(jì)荷載的垂直承力構(gòu)件。試件高度至少應(yīng)包括一個(gè)層高,并16.4.2.4抗風(fēng)壓性能檢測需要對面板變形進(jìn)行測量時(shí),幕墻試件至少應(yīng)包括2個(gè)承受設(shè)計(jì)荷載的垂直承力構(gòu)件和3個(gè)橫向分格,所測量撓度的面板應(yīng)能模擬實(shí)際狀態(tài)。16.4.2.5全玻璃幕墻試件應(yīng)有一個(gè)完整跨距高度,寬度應(yīng)至少有3個(gè)玻璃橫向分格或4個(gè)玻璃肋。16.4.2.6單元式幕墻至少應(yīng)有一個(gè)單元的四邊與鄰近單元形成的接縫與實(shí)際工程相同,且高度應(yīng)大于17.1一般規(guī)定17.1.1幕墻構(gòu)件的加工制作,應(yīng)以依照審查合格的施工圖或模型繪制的加工圖為依據(jù)。17.1.2構(gòu)件加工所采用的機(jī)具、設(shè)備應(yīng)滿足加工精度的要求,量具應(yīng)定期檢定校準(zhǔn)。17.1.3幕墻構(gòu)件的原材料應(yīng)滿足設(shè)計(jì)要求并符合相關(guān)規(guī)范。17.1.4幕墻構(gòu)件、組件和配件均應(yīng)按工藝要求在工廠完成加工。17.2.1鋁合金構(gòu)件加工應(yīng)符合以下要求:b)加工時(shí)應(yīng)保護(hù)型材表面,半成品應(yīng)在明顯處貼標(biāo)識;c)經(jīng)沖孔、銑切等工序后的型材切口應(yīng)平整、光滑;d)加工工序完成后應(yīng)進(jìn)行檢驗(yàn),并進(jìn)行成品保護(hù);17.2.3型材鉆孔應(yīng)符合以下要求:e)螺孔加工應(yīng)符合設(shè)計(jì)要求。17.3.1預(yù)埋件加工17.3.1.1錨板及錨筋的材質(zhì)應(yīng)符合設(shè)計(jì)要求。17.3.1.2預(yù)埋件的錨筋與錨板之間的焊縫應(yīng)符合國家相關(guān)規(guī)范和設(shè)計(jì)要求。17.3.2平板型預(yù)埋件加工精度17.3.2.4錨筋與錨板面的垂直度允許偏差為ls/30(ls為錨筋長度)。17.3.3槽式預(yù)埋件加工精度17.3.4連接件、支承件加工精度17.3.4.1連接件、支承件外觀應(yīng)平整,不應(yīng)有裂紋、毛刺、凹凸、翹曲、變形等缺陷。17.3.4.2連接件、支承件外形加工尺寸允許偏差見表48?!?.0±2°17.3.5鋼型材加工17.3.6鋼構(gòu)件焊接17.4玻璃面板加工6,8,10,12±1.0±1.5±1.5±2.06,8,10,12≤1.5≤2.0≤2.0≤2.5±1.0±1.5L≥2000±2.0L≤2000≤1.5≤2.0±1.0±1.5t≥22±2.0±2.0±3.0±4.0L≥4000±6.0L≤2000±2.0±2.5L≤2000≤2.5≤3.5±2.0±3.0±4.0L≥4000±6.017.4.4彎曲加工成型后的玻璃板塊應(yīng)符合以下要求:a)溶劑應(yīng)存放在干凈的容器中,保存和使用溶劑應(yīng)遵守各項(xiàng)溶劑注意事項(xiàng);b)應(yīng)將溶劑傾倒在擦布上,不應(yīng)用擦布蘸溶劑,不應(yīng)將擦布浸泡在溶劑中;c)每清潔一個(gè)構(gòu)件或一塊面板,應(yīng)換用清潔的干擦布;17.4.7采用雙組份硅酮結(jié)構(gòu)密封膠時(shí),應(yīng)進(jìn)行混勻性試驗(yàn)和拉斷試驗(yàn)。17.4.10注膠應(yīng)飽滿,不應(yīng)出現(xiàn)氣泡,表面應(yīng)平整光滑。17.4.12夾層玻璃中的膠片不宜接觸硅酮密封膠,注膠前可對其端面密封處理。a)夾板粘結(jié)部位玻璃表面處理應(yīng)符合本文件17.4.6條的規(guī)定;b)楔形夾板和襯墊材料應(yīng)滿涂專用強(qiáng)力膠粘劑,玻璃雙面粘貼夾緊后靜置養(yǎng)護(hù)至膠粘劑完全固17.5金屬面板加工17.5.1金屬板材的品種、規(guī)格、材質(zhì)、表面處理及色澤應(yīng)符合設(shè)計(jì)要求。17.5.2單層金屬板加工應(yīng)符合下列要求:a)金屬板折彎加工時(shí),折彎外圓弧半徑不應(yīng)小于板厚的1.5倍;b)金屬板加強(qiáng)肋的固定采用焊接螺柱時(shí),金屬板外表面不應(yīng)變形、變色。17.5.3金屬復(fù)合板加工應(yīng)符合下列要求:b)鉆孔、切口等處的外露芯材及角縫,應(yīng)采用中性硅酮耐候密封膠密封;c)在加工過程中鋁復(fù)合板不應(yīng)與水接觸;±1.0±1.5≤1.5≤2.0≤1.5≤2.5≤1±1.517.6石材及其他板材加工17.6.1石板加工應(yīng)符合下列要求:a)石材的品種、石板的外形尺寸、色澤、紋理應(yīng)符合設(shè)計(jì)要求;d)加工后的石材表面應(yīng)清理干凈,不應(yīng)采用溶劑型的化學(xué)清潔劑清洗;e)石板應(yīng)進(jìn)行各面防護(hù)處理;f)石板的槽口寬度、深度尺寸按設(shè)計(jì)要求加工。17.6.2通槽式、短槽式的石板加工應(yīng)符合下列要求:c)石材開槽后不應(yīng)有損壞或崩裂,槽內(nèi)應(yīng)光滑、潔凈。17.6.3石材及其他板材的背栓式鉆孔應(yīng)符合設(shè)計(jì)要求。17.6.4背栓孔加工應(yīng)符合下列要求:-0.2~+0.4±0.3-0.1~+0.4±0.3-1.0~+5.017.7構(gòu)件組裝17.7.1開啟扇組裝17.7.1.1采用帶掛鉤的開啟扇,應(yīng)按加工圖設(shè)置防滑和防脫落裝置。17.7.1.3裝配五金件的孔應(yīng)攻絲,絲孔應(yīng)符合設(shè)計(jì)要求。17.7.1.4開啟窗安裝附件處的型材壁厚小于螺釘?shù)墓Q直徑時(shí),扇框內(nèi)壁宜加襯板。17.7.1.5開啟窗四周的橡膠條轉(zhuǎn)角和接頭部位應(yīng)采用粘結(jié)劑粘結(jié)牢固,鑲嵌平整。17.7.1.6開啟窗應(yīng)保證拼接處密封性能,框、扇宜采用組角方式組裝。17.7.1.7開啟窗的組件加工尺寸偏差應(yīng)符合表55的1±1.02±1.53≤0.34≤1.0≤2.05≤0.5678≤1.517.7.2石板背栓組裝17.7.2.1石材背栓組裝應(yīng)按設(shè)計(jì)和產(chǎn)品加工組裝要求執(zhí)行。玻璃幕墻組件裝配尺寸偏差應(yīng)符合表56L≤2000≤1.0≤2≤1.5≤2.5L≤2000≤1.5≤3≤2.0≤3.5L≤2000≤0.5≤1≤0.5≤1.5L≤2000≤0.5≤1≤0.5≤1.517.7.3單元板組裝17.7.3.1單元板塊應(yīng)按加工圖和工藝要求加工組裝。17.7.3.2單元板塊的硅酮結(jié)構(gòu)密封膠不應(yīng)直接外露在室外。17.7.3.3型材螺釘孔內(nèi)徑和擰入扭矩應(yīng)符合表57的4.24.44.66.35.56.317.7.3.4單元板塊組裝完成后,工藝孔宜封堵,通氣孔及排水孔應(yīng)暢通。17.7.3.5單元板組裝應(yīng)質(zhì)量符合表58的規(guī)定。1±1.0±1.52≤1.5≤2.03≤0.54≤0.55≤3處且總長≤10062708090≤1.5±1.0±1.0±1.0(可上、下調(diào)節(jié)時(shí)±2.0)±1.0±1.0±0.5±1.017.E構(gòu)件檢驗(yàn)17.8.2產(chǎn)品應(yīng)附有檢驗(yàn)合格證書。18.1一般規(guī)定18.1.1幕墻安裝施工應(yīng)符合國家和地方相關(guān)規(guī)范和管理文件的要求。18.1.2幕墻安裝施工前,主體結(jié)構(gòu)應(yīng)驗(yàn)收合格。18.1.3幕墻安裝施工前,設(shè)計(jì)圖紙及資料應(yīng)經(jīng)審核批準(zhǔn)。18.1.4典型幕墻系統(tǒng)宜制作樣板,經(jīng)相關(guān)單位認(rèn)可后再批量施工。18.1.6進(jìn)場安裝的幕墻構(gòu)件及附件產(chǎn)品材料的品種、規(guī)格、顏色和性能,應(yīng)符合設(shè)計(jì)要求。18.1.7幕墻安裝施工全過程應(yīng)做好產(chǎn)品保護(hù)。18.1.8防火、防雷及隱蔽設(shè)施安裝施工應(yīng)符合設(shè)計(jì)要求。18.1.10隱框、半隱框玻璃幕墻組件不應(yīng)在施工現(xiàn)場打注硅酮結(jié)構(gòu)密封膠。18.1.11進(jìn)行焊接作業(yè)時(shí),應(yīng)對受其影響的幕墻部件采取有效的保護(hù)措施。施焊后應(yīng)對受到焊接影響18.2.1安裝施工前首先應(yīng)對幕墻施工圖進(jìn)行熟悉和理解,掌握項(xiàng)目幕墻系統(tǒng)分類和主要特征。18.2.2安裝施工前應(yīng)進(jìn)行安裝施工技術(shù)交底。18.2.4安裝施工前應(yīng)進(jìn)行幕墻測量放線,測量放線應(yīng)符合下列要求:c)幕墻施工,應(yīng)對主體結(jié)構(gòu)施工過程中的垂直度和樓層外輪廓進(jìn)行測量、監(jiān)控;d)測量放線工作應(yīng)在確保作業(yè)安全的條件下進(jìn)行。18.2.5構(gòu)件臨時(shí)存放應(yīng)依照安裝順序排列。室外存儲時(shí)應(yīng)采取保護(hù)措施。18.2.7預(yù)埋件安裝應(yīng)符合下列要求:b)澆筑混凝土?xí)r應(yīng)采取措施防止埋件發(fā)生位移,保持埋件位置準(zhǔn)確;e)安裝連接件前應(yīng)清理預(yù)埋件,使埋板露出金屬面。18.2.8偏位預(yù)埋件的處理應(yīng)符合下列要求:a)偏差過大不滿足設(shè)計(jì)要求的預(yù)埋件應(yīng)補(bǔ)充后置埋件;c)后置埋件鉆孔時(shí),鉆孔深度應(yīng)滿足后置埋件的有效埋設(shè)長度,并清理鉆孔。18.2.9索結(jié)構(gòu)預(yù)埋件應(yīng)隨主體結(jié)構(gòu)施工同步實(shí)施,應(yīng)盡量避免使用后置埋件。18.3構(gòu)件式幕墻安裝18.3.1立柱安裝應(yīng)符合下列要求:18.3.2橫梁安裝應(yīng)符合下列要求:a)橫梁應(yīng)安裝牢固,符合設(shè)計(jì)要求;c)一層橫梁安裝完成后,應(yīng)及時(shí)檢查、校正和固定。18.3.3幕墻主要附件安裝應(yīng)符合下列要求:c)現(xiàn)場焊接或高強(qiáng)螺栓緊固的構(gòu)件,焊接或緊固后應(yīng)及時(shí)防銹處理;d)幕墻安裝時(shí)用的臨時(shí)襯墊、固定材料,應(yīng)在構(gòu)件緊固后拆除;e)膠條安裝應(yīng)符合設(shè)計(jì)要求。18.3.5裝飾構(gòu)件應(yīng)順直平整、接縫均勻。18.3.6構(gòu)件式石材幕墻安裝允許偏差除應(yīng)符合本節(jié)的相關(guān)規(guī)定外,其石材幕墻掛件安裝允許偏差尚1≤1.02±1.03≤1.04≤2.05±2.06±1.07±1.018.3.7硅酮建筑密封膠施工應(yīng)符合下列要求:c)接縫內(nèi)的硅酮密封膠應(yīng)與接縫兩側(cè)端面粘結(jié),不應(yīng)三面粘結(jié)。18.3.8明框幕墻組件的透氣孔和排水孔設(shè)置應(yīng)符合設(shè)計(jì)要求,并保持通暢。18.3.9明框幕墻安裝時(shí),應(yīng)控制面板與框料之間的間隙。18.4單元式幕墻安裝18.4.1單元板塊的運(yùn)輸和存放應(yīng)符合下列要求:a)單元板塊應(yīng)做好成品保護(hù);b)現(xiàn)場宜設(shè)置專用堆放場地,單元板塊應(yīng)存放在周轉(zhuǎn)架上。18.4.2單元式幕墻的吊裝應(yīng)符合下列要求:a)安裝單元板塊的吊裝機(jī)具應(yīng)進(jìn)行專門設(shè)計(jì);18.4.3單元板塊的安裝應(yīng)符合下列規(guī)定:a)板塊安裝應(yīng)按照施工組織設(shè)計(jì)的要求進(jìn)行,并按設(shè)計(jì)要求做好板塊接縫的防水密封處理;c)應(yīng)按設(shè)計(jì)要求安裝防雷裝置、保溫層、防火層;1H≤30m20.025.022.532.542.55±2.06L≤20m3.06.0783.05.09±1.0±1.018.5全玻璃幕墻安裝18.5.1全玻璃幕墻安裝前,應(yīng)清潔鑲嵌槽;中途暫停施工時(shí),槽口應(yīng)采取保護(hù)措施。18.5.2全玻璃幕墻宜采用機(jī)械吸盤安裝,并應(yīng)采取必要的安全措施。18.5.3全玻璃幕墻安裝完成后,玻璃嵌入槽口深度及預(yù)留空隙應(yīng)符合本文件第1幕墻高度H/mH≤30m20.025.022.532.542.55±2.067≤1°18.6點(diǎn)支承玻璃幕墻安裝a)支承結(jié)構(gòu)安裝過程中,組裝、焊接和涂裝修補(bǔ)等,應(yīng)符合相關(guān)標(biāo)準(zhǔn)的規(guī)定;b)支承結(jié)構(gòu)安裝就位,經(jīng)調(diào)整后應(yīng)及時(shí)緊固定位,并對隱蔽工程驗(yàn)收。18.6.2拉桿、拉索施加預(yù)拉力的要求:a)拉桿、拉索應(yīng)按設(shè)計(jì)要求施加預(yù)拉力,設(shè)置預(yù)拉力調(diào)節(jié)裝置并測定預(yù)拉力;c)在張拉過程中,應(yīng)分批、分次對稱張拉,隨時(shí)調(diào)整預(yù)拉力,并做好張拉記錄。18.6.3點(diǎn)支承幕墻玻璃與金屬連接件不應(yīng)直接接觸。±2.5L/1000
溫馨提示
- 1. 本站所有資源如無特殊說明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請下載最新的WinRAR軟件解壓。
- 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請聯(lián)系上傳者。文件的所有權(quán)益歸上傳用戶所有。
- 3. 本站RAR壓縮包中若帶圖紙,網(wǎng)頁內(nèi)容里面會有圖紙預(yù)覽,若沒有圖紙預(yù)覽就沒有圖紙。
- 4. 未經(jīng)權(quán)益所有人同意不得將文件中的內(nèi)容挪作商業(yè)或盈利用途。
- 5. 人人文庫網(wǎng)僅提供信息存儲空間,僅對用戶上傳內(nèi)容的表現(xiàn)方式做保護(hù)處理,對用戶上傳分享的文檔內(nèi)容本身不做任何修改或編輯,并不能對任何下載內(nèi)容負(fù)責(zé)。
- 6. 下載文件中如有侵權(quán)或不適當(dāng)內(nèi)容,請與我們聯(lián)系,我們立即糾正。
- 7. 本站不保證下載資源的準(zhǔn)確性、安全性和完整性, 同時(shí)也不承擔(dān)用戶因使用這些下載資源對自己和他人造成任何形式的傷害或損失。
最新文檔
- 人工智能智能語音翻譯系統(tǒng)在智能翻譯行業(yè)發(fā)展趨勢中的應(yīng)用開發(fā)可行性研究報(bào)告
- 2025年制造業(yè)工業(yè)互聯(lián)網(wǎng)發(fā)展現(xiàn)狀與創(chuàng)新趨勢報(bào)告
- 咳喘門診應(yīng)急預(yù)案(3篇)
- 戲劇表演在心理輔導(dǎo)中的應(yīng)用劇本
- 早餐店施工方案(3篇)
- 地坪恢復(fù)施工方案(3篇)
- 水面屏障施工方案(3篇)
- 天河花園施工方案(3篇)
- 醫(yī)院急診室管理規(guī)范及操作流程
- 爬山秋游活動策劃方案(3篇)
- DB32-T 4111-2021 預(yù)應(yīng)力混凝土實(shí)心方樁基礎(chǔ)技術(shù)規(guī)程
- 不同時(shí)代的流行音樂
- 醫(yī)療衛(wèi)生機(jī)構(gòu)6S常態(tài)化管理打分表
- 幾種常用潛流人工濕地剖面圖
- vpap iv st說明總體操作界面
- 2023人事年度工作計(jì)劃七篇
- LY/T 1692-2007轉(zhuǎn)基因森林植物及其產(chǎn)品安全性評價(jià)技術(shù)規(guī)程
- GB/T 20145-2006燈和燈系統(tǒng)的光生物安全性
- 長興中學(xué)提前招生試卷
- 螺紋的基礎(chǔ)知識
- 蜂窩煤成型機(jī)課程設(shè)計(jì)說明書
評論
0/150
提交評論