已閱讀5頁,還剩1頁未讀, 繼續(xù)免費閱讀
版權說明:本文檔由用戶提供并上傳,收益歸屬內容提供方,若內容存在侵權,請進行舉報或認領
文檔簡介
Ultrasonic Level Meter USER MANUAL Ultrasonic Level Meter Receipt Acknowledgement of Warranty Card for Ultrasonic Level MeterUsers nameContact addressContact personTel.Product typeProduct No.Date of acceptance checkSetter in-chargeNotes on Warranty Card for Dual Point Ultrasonic Level MeterProduct typeProduct No.Date of acceptance checkSetter in-chargeWarranty policies:l The user shall show the warranty card when the meter is repaired. If any fault arises because of normal using during the warranty period, the meter will be repaired for free by virtue of the warranty card.l Warranty period: The warranty period of products of the company shall last twelve months since the date of acceptance check. Following cases are beyond the scope of free warranty:l The product or its part is beyond the period of free warranty.l Hardware fault caused by that the application environment does not meet the products application requirements.l Faults or damage caused by bad power supply environment or by foreign matters entering the equipment.l Faults caused by the operation that is not carried out according to application methods and points for attention stated in the using and operation manual. l Faults caused by natural factors and force majeure, such as thunder, flood, and water.Faults or damage caused by dismounting or repair without permission, by unauthorized refit, or by abuse Points on restriction:l The warranty card should be properly kept by the user to be as the warranty certificate. If lost, it wont be reissued.The company shall own the warranty cards interpretation power and have the right to amend the cards contents without advance notice. 7 Ultrasonic Level Meter Catalogue1 Overview .12 Technical targets13 Installation of meter 23.1 Meters overall size .2 3.2 Meters wiring 2 3.3 The meaning of installation parameters .33.4 Installation principles of meter3 3.5 Points for attention on installation44 Debugging of meter4 4.1 Keyboard directive .4 4.2 Password directive . 5 4.3 Setting of parameters . 5 4.3.1 Demarcating of liquid level【P01 】 5 4.3.2 Setting of 20mA【P02 】 5 4.3.3 Display mode settings【P03 】 5 4.3.4 Probe height【P04 】 6 4.3.5 Reaction rate is set【P05 】 6 4.3.6 Blind spot Set【P06】 .6 4.3.7 Test 420mA【P09 】 .6 Ultrasonic Level Meter 1、OverviewSincerely thank you for buying our ultrasonic level meter.The meter includes several proprietary technologies, is safe and clean, with high precision and long service life, stable and reliable, and convenient to install and maintain, and is applicable to various fields of acid, alkali, salt, anticorrosion, and high temperature. The meter is with following features:l For circuit design, high-quality power modules are selected to be as power supply parts and highly stable and reliably imported devices are used as components of the meter. It can fully replace imported foreign meters of the same type. l Patent sonic-wave intelligent technology software can make intelligentized echo analysis. It needs neither debugging nor other special steps. This technology has functions of dynamic thinking and dynamic analysis. l Our sonic-wave intelligent patent technology greatly improves the meters precision, and the precision of liquid level is up to 0.3%, which is enough to resist various interference waves. l The meter is a non-contact one and does not directly contact liquid, so the fault rate is low. The meter can be installed in several different ways, and the user can make meter calibration according to the Manual. l The meters all input and output lines must be with such protection functions as lightning protection and short circuit prevention. 2、Technical targetsMeasuring range: 015m(Chosen based on actual measuring range)Blind area: 0.25m0.6mRanging accuracy: 0.3%(Standard condition)Ranging resolution: 1mmPressure: Less than four atmospheric pressureMeter display: With LCD to display liquid levels.Analog output: 420mADigital output: RS485, Agreement Modbus or customization agreementPower supply voltage: DC24V/AC220V, lightningproof device installed insideAmbient temperature: 20 60Protection grade: IP651 Ultrasonic Level Meter 4.3.4 Probe height(P04)P04 menus can be displayed probe height, can see whether the height can Meet the situation on the ground, Can also be used for Calibration of the liquid level. In accordance with the situation on the ground to change the value of the probe height4.3.5 Reaction rate is set(P05)(P05)Reaction rate is set “00 ”is the fastest; “01”is faster ; “02”is medium-speed; “03”is slow. 4.3.6 Blind spot Set(P06)Can change the instruments blind spot to accommodate to complex working conditions. For example, the protruding material impact on the instrument can be avoided near the transducers.4.3.7 Test 420mA (P09)(P09) Test 420mA current. 6 Ultrasonic Level Meter 【OK】:Confirmation key. Choose menu or confirm option and data. 4.2 Password directivePress key Mode, the password interface will appear: “0000”; press key 【】to change the first place into 1, and press key 【OK】to enter the interface of parameter setting menu.4.3 parameter setti4.3.1 Level Calibration(P01)Finished Meter installed, power-on. The LCD will show the level value, but the data are often inconsistent with the actual level, so it need level calibration.Level calibration steps are as follows: press 【Mode】and enter password then press 【OK】and enter the parameter setting menu. P01 is level calibration menu, Press OK button to P01 level calibration with (shift), and (numbers change) will be replaced by the actual level value of the number(as 2.100), Press OK button to confirm, then press Mode key to exit the parameter setting menu, LCD will be displayed at this time.4.3.2 Set 20mA(P02) Instrument Normal working hours press Mode key to enter the parameter setting menu, press choose menu P02, The second line corresponds to number shall be 20mA level, press OK key to set。For example: Range is 0 10 meter ultrasonic level gauge, the actual maximum level in the field is 6.5 meters, 6.5m can be set to 20mA, When the liquid level reaches 6.5 meters, the output current is 20mA. 20mA can also be set to 7.0 meters, then when the level reached 7.0 meters, the output current is 20mA4.3.3 Display mode settings(P03)Menu P03 can change the display mode, a total of three display modes to choose1. “00”Liquid level and relay status display2. “01” Display space distance3. “02”Display space distance and temperature , Press key to select the desired mode and then press the OK button to confirm.5 Ultrasonic Level Meter3、Installation of meter3.1 Meters overall sizeInstallation way: Open environment commonly used stent installation method, using a fixed flange own instrument.3.2 Meters wiring 2Ultrasonic Level Meter 3.3 The meaning of installation parametersAs shown, instruments transducers made after the wave hit the level reflected back to transducer, the transducer receives income calculated after the hair waves to waves of time, are measured from the L, meter installation height minus the measurement of TH the distance L will be the current level H. Meter range means the instrument can measure the distance, the installation should be less than a high degree of TH range. Instrument blind means measuring instruments in the vicinity of the transducer can not be measured in the region, the highest level with the transducer spacing should be greater than the blind, for example: blind spot for the 0.3m, the highest level with the transducer spacing must be greater than 0.3m.3.4 Instrumentation Principles1. The distance of transducer launching surface to the lowest level should be less than the purchase instrument range2. The distance of the transducer launching surface to the highest liquid level should be greater than the purchase of the blind instrument3. The launch surface of the transducer should be keep parallel to the liquid surface. 4. Transducer installation location should be as far as possible avoid these liquid surface fluctuations position that just under the inlet, outlet ,if It is impossible to avoid, 3 Ultrasonic Level Meterplease install guided-wave tube to aid in measuring.5. If the pool wall or tank wall is not smooth, meter installation location should at least more than 0.5m from the pool wall or tank wall. The specific distance from the pool wall or the tank wall determined according to the actual situation.6. If the distance of the transducer launching surface to the highest level is less than the blind area of the purchase instrument is required to install an extension tube, that diameter is greater than 200mm, and the length is 0.35m0.50m.3.6 Installation Notes1. The instrument used outdoors, it is best to install awning or the protecting housing, so as to avoid the LCD screen ageing affected by sunlight. 2. Wire, cable protection pipes, pay attention to sealing to prevent water, and prevent mice and other rodents Bite.3. Although the instrum
溫馨提示
- 1. 本站所有資源如無特殊說明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請下載最新的WinRAR軟件解壓。
- 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請聯(lián)系上傳者。文件的所有權益歸上傳用戶所有。
- 3. 本站RAR壓縮包中若帶圖紙,網頁內容里面會有圖紙預覽,若沒有圖紙預覽就沒有圖紙。
- 4. 未經權益所有人同意不得將文件中的內容挪作商業(yè)或盈利用途。
- 5. 人人文庫網僅提供信息存儲空間,僅對用戶上傳內容的表現(xiàn)方式做保護處理,對用戶上傳分享的文檔內容本身不做任何修改或編輯,并不能對任何下載內容負責。
- 6. 下載文件中如有侵權或不適當內容,請與我們聯(lián)系,我們立即糾正。
- 7. 本站不保證下載資源的準確性、安全性和完整性, 同時也不承擔用戶因使用這些下載資源對自己和他人造成任何形式的傷害或損失。
最新文檔
- 企業(yè)品牌形象推廣及宣傳方案
- 海洋漁業(yè)捕撈作業(yè)聯(lián)營合同
- 客戶服務高效售后承諾書5篇
- 環(huán)境保護與公益體驗活動方案
- 教育事業(yè)優(yōu)先支持承諾書7篇
- 線上交易確保完成承諾函(6篇)
- 遙感技術應用于農業(yè)種植合同
- 2025年福建省事業(yè)編面試題庫及答案
- 2025年團支書競選筆試和面試及答案
- 2025年濰坊科技學院招聘筆試題及答案
- 學校中層管理崗位職責及分工明細(2026年版)
- 莆田春節(jié)習俗介紹
- 江蘇省南京市2025屆中考化學試卷(含答案)
- 飛行固模課件
- 2026年短視頻合作合同
- 建筑臨時設施設計方案
- 污水廠春節(jié)復工安全培訓課件
- 生活化課程培訓
- 教科版九年級物理上冊專項突破提升檢測(四)電磁學實驗及作圖含答案
- GB/T 32399-2024信息技術云計算參考架構
- 高速公路收費站QC小組成果如何降低入口發(fā)卡差錯率
評論
0/150
提交評論