版權(quán)說(shuō)明:本文檔由用戶提供并上傳,收益歸屬內(nèi)容提供方,若內(nèi)容存在侵權(quán),請(qǐng)進(jìn)行舉報(bào)或認(rèn)領(lǐng)
文檔簡(jiǎn)介
整機(jī)柜服務(wù)器解決方案技術(shù)規(guī)范PAGEPAGE3/17目錄TOC\o"1-2"\h\z\u一、概述 4二、技規(guī)范文 4機(jī)柜模(RackModule) 4網(wǎng)絡(luò)模(NetworkModule) 6供電模SupplyModule) 7散熱模(CoolingModule) 11服務(wù)器點(diǎn)(ServerNode) 13機(jī)柜管模塊(RMCModule) 14天蝎項(xiàng)目-天蝎項(xiàng)目-整機(jī)柜服務(wù)器解決方案-version1.0PAGEPAGE10/17一、概述天蝎整機(jī)柜服務(wù)器機(jī)架方案采用模塊化設(shè)計(jì),分為機(jī)柜模塊、網(wǎng)絡(luò)模塊、供電模塊、服務(wù)器節(jié)點(diǎn)、集中風(fēng)扇散熱模塊、集中管理模塊共六大部分組成。2100mm600mm、深度1200mm44U20U、最下20U1U1、1U2、1U31204UPSURMCPSU采用同平面部署的緊湊設(shè)計(jì)。PSU3UN+N7~12KVA、、240VDC12VDC600務(wù)器節(jié)點(diǎn)通過(guò)背板或母排直接取電。集中風(fēng)扇散熱模塊,采用了風(fēng)扇墻共享設(shè)計(jì),由RMC實(shí)現(xiàn)獨(dú)立風(fēng)扇控制。采用了N+1冗余設(shè)計(jì),可以實(shí)現(xiàn)獨(dú)立維護(hù),對(duì)節(jié)點(diǎn)透明。二、技術(shù)規(guī)范正文機(jī)柜模塊(RackModule)子項(xiàng)Spec描述機(jī)柜總高度Totalheight2100mm2100mm0.5%2100mmincludewheels,andthesamewheninfixedposition.Toleranceis0.5%.機(jī)柜內(nèi)部可用空間InternalUspace44U。要求采用標(biāo)準(zhǔn)高度,不能采用0.9U等非標(biāo)規(guī)格,下同。44U.MustusestandardUheight,nonon-standardUheight0.9U,thesameforallbelow.計(jì)算節(jié)點(diǎn)可用空間Computenode40U,機(jī)柜上下兩端各20U。40U.20Ueachfortopandbottomhalf.spaceNetworkequipmentspace21U~24U21U24U≥750mm,3U≥550mm后出的進(jìn)風(fēng)模式。4U.The21stUto24thUspaceusedforswitches.The21stor24thUshouldhavedepthmorethan750mm,other3Uhavedepthmorethan550mm.Supportfromtorearandsidetorearswitchesairflowmodes.電源可用空間Powermodulespace≤3U,21~24U同一平面,布局在機(jī)柜后方?!?U.Placedinthe21~24Upositioncountingfrombottomtotop.InthesameUspaceofswitches,attherearside.RMC可用空間RMCspace≤1U,布局在機(jī)柜由下至上第21~24U的空間之內(nèi)?!?U.Placedinthe21~24Upositioncountingfrombottomtotop.機(jī)柜外框尺寸Externalframesize機(jī)柜承重外框不含前門(mén)的尺寸是1200(深)*600(寬)。1200mm(D)*600mm(W),withoutthefrontdoor.機(jī)柜承重能力Rackweightbearing≥1200KG/機(jī)柜≥1200KGperrack滾輪規(guī)格Wheelspec承重≥600KGWeightbearing≥600kgperwheel計(jì)算節(jié)點(diǎn)機(jī)位標(biāo)識(shí)順序NodeIDnumbering節(jié)點(diǎn)編號(hào)為xxYxx01-40Y1U2N01B計(jì)算節(jié)點(diǎn)機(jī)位標(biāo)識(shí)方法Nodeidentification10應(yīng)采用粘貼標(biāo)簽紙等易脫落措施。Shouldbefixednexttothenode,ontherackstructurewhichisnotpartofthenode.Fontsizenotsmallerthan10.notusefacilitylikestickynotesthatareeasytolose.柜門(mén)要求Door開(kāi)孔率(開(kāi)孔面積的百分比)75%。Nodoorinstalledbydefault,butmustsupportinstalloffrontdoor.Openingholespace/doorsurfacerationshouldbe≥75%.機(jī)柜接地設(shè)計(jì)Grounding機(jī)柜門(mén)與主架構(gòu)要求具有接地端子。機(jī)柜上下都保留接地端子。Thedoorandthemainstructureshouldhavegroundingconnector,atbothtopandbottomside.理線槽Grooveforcabling前走線,機(jī)柜兩側(cè)預(yù)留理線槽,兼容電纜和光纖。Frontcabling. Shouldreserveroomforgrooveonthetwoinnersidesoftherack. Thegrooveshouldsupportbothcopperopticalfibercables.機(jī)柜移動(dòng)與固定依靠滾輪滑動(dòng)。固定方式為支腳固定加并柜結(jié)構(gòu)件并柜。Movingbythewheelatbottom.Fixingbypillarsatbottom,componentbetweenrackstofixseveralracksinrow.網(wǎng)絡(luò)模塊(NetworkModule)子項(xiàng)Spec描述交換機(jī)最大可用臺(tái)數(shù)Maximumnumberofswitch4交換機(jī)風(fēng)流管理Airflowforswitch前進(jìn)后出或側(cè)進(jìn)后出。Frontinrearout,orsideinrearout.交換機(jī)維護(hù)性Servicability一起順暢出入。Switchpull/plugshouldnotbeinterferedbynetworkcables,andthepowercableshoulebeabletofollowswitchinandsmoothly.網(wǎng)絡(luò)布線模式Cabling應(yīng)端口中。Allcablesfromnodeshouldberoutetothecablingroovetherack,thentothemiddleoftherack,thenintotheswitchports.交換機(jī)冗余性供電支持Redundantpowersupplyfor要求支持,但是否實(shí)際配置按用戶具體需求而定。Support,butconfigurableaccordingtoorder.switches供電模塊(Module)子項(xiàng)Spec描述組成Components由PDU、電源框、電源模塊、銅排(busbar)、背板組成。PDU,powerframe,power,busbar,backplane.機(jī)柜接入電路方式InputCircuitqty.inRACK12(32A)高壓直流。Dual-wayredundant(Including3kindsofpowersupply: 2-waythree-phaseAC,2-waysingle-phaseAC,1-waythree-phaseAC2-wayhighvoltageDC)PDU數(shù)量PDUquantity雙路交流時(shí)=2≤3(3PDU,一條給交流,剩余兩條給直流)。2for2-wayAC,lessthan4forACandDC(oneforACandtwoforDCifthreePDUsareused)PDU布局PDUPosition布局于機(jī)柜后方Rearofrack.PDUIDC'spowersupplyPDU,240V(32A)直流的接入。Supportthree-phase5-wireAC,single-phaseACand240VvoltageDC.PDU分配方式AssignmentofeveryPDUinterface不少于4個(gè)接口分配給電源,不少于4個(gè)分配給交換機(jī)。Nolessthan4interfaceassingedforpowersupply,noless4interfacesassignedforswitches.PDU接口標(biāo)準(zhǔn)StandardofPDUinterfaceIEC6030932A63A(其中高壓直流輸入必須采IEC320UL94-V0。Input:IEC60309seriesconnector32Aor63A,outputisIEC320seriesC13&10A,C19&16A;plasticsflammabilitystandard:UL94-V0.供電冗余模式Powershelfredundantmode2220VAC2N220VAC1240VDC2NSupport2redundantmodes:(1)2Nredundantofdual-way220VAC;(2)2Nredundantofone-way220VAC+one-way240VDC.單路供電能力Max.loadsupplyingcapabilityofPowersupplyframe7KW~12KW力,并使電源工作在最佳轉(zhuǎn)換效率。Byusingdifferentkindofpowersupplyprovidingdifferentpower,thesinglerackcanprovidesmax.7KVA~12KVApowertotally,withthebestconversionefficiencyofpower電源維護(hù)性Powermaintanence可熱拔插Hotpluggable電源均流能力Proportionofloadofpowersupply20%均流度≤5%。Thedefinationofproportionratioofpowersupplyonworkingstatus:ifloadofsinglepowersupply≥20%,thenpowersupplyproportionratio≤5%Electricityconversion兩類:(1)220VAC~12VDC;(2)240VDC~12VDC。220VAC~12VDCor240VDC~12VDC電源轉(zhuǎn)換效率Efficiencyofpowersupplyconversion240VDC負(fù)載負(fù)載≥94%,100%負(fù)載≥91%。Requirementofefficiencyofpowersupplyconversion: 220Vacor240Vdc,20%load≥91%;50%load≥94%,100%≥91%。電源PFPowersupplyPFPF:220Vac≥20%PF≥0.9750%PF0.99。PFrequirement:INPUT220Vac,load>20%,PF≥0.97;load>50%,PF≥0.99.電源電力質(zhì)量Qualityofelectricpower:VoltageTHD10%distortion源的正常工作;CurrentTHD:IEC61000-3-2≥50%時(shí),CurrentTHD≤5%;20%~50%之間時(shí),CurrentTHD≤10%。VoltageTHDrequirement:10%distortionofINPUTvoltagedoesn'taffectthefunctionofpowersupply;CurrentTHD:IEC61000-3-2,andifload≥50%,CurrentTHD≤5%;load20%~50%,CurrentTHD≤10%.PowerSupplyoperatingenvironmenttemperature10℃~50℃狀態(tài)指示燈StatusLED正常為綠色常亮,故障為紅色或橙色(可以選擇常亮或閃爍)。Greenconstantlightfornormalstatus,redororangelighterror.柜內(nèi)12V傳輸介質(zhì)12Vtransfermediainrack銅排(busbar)Copper(busbar)銅排數(shù)量Copperbusbarqty.2對(duì)2pair銅排額定電流Copperbusbarratingcurrent≥600A≥600A銅排絕緣要求CopperbusbarRequirementofinsulationGB/T17045-2008現(xiàn)完全絕緣隔離保護(hù)及與交流高壓的故障隔離保護(hù)。FollowingGB/T17045-2008,Generalsectionof"equipmentdeviceforprotectionagainstelectricshock";totallyinsulatedprotectionsforpositiveandnegativepoles,faultisolatedprotectionforhighvoltageAC.銅排供電質(zhì)量CopperbusbarPowersupplyquality插拔直接/間接由銅排供電的部件,和同一根銅排上所有節(jié)點(diǎn)同時(shí)或分開(kāi)上電/開(kāi)機(jī)/關(guān)機(jī)/下電時(shí),節(jié)點(diǎn)的接入電壓范圍在11.6~12.6V之間。Directly/indrectlypullingoutorpluginginthecomponentswhichpowerareprovidedbycopperbusbar,andpowerbeingconnected/disconnected/on/off/allthenodesonthecopperbusbar(atthesametimeorindividually),theinputvoltageofnodeisbetween11.6~12.6V.銅排耗能Powerconsumptionofcopperbusbar600Apowerloss≤0.5%;700A時(shí),powerloss≤0.6%;800A,powerloss≤0.7%。Maximumpowerlossofallthecopperbusbarinthewholerack:lessthan0.5%whenbelow600A,0.6%whenbelow700A,0.7%whenbelow800A.電源背板功能Backplanefunctionofsupplyframe用于實(shí)現(xiàn)電源冗余、電源管理,并與銅排(busbar)連接。Providingpowerredundant,powermanagement,andconnectiongtocopperbusbar.背板尺寸與位置Backplanesizeandpostion暫不定義Nodefinationcurrently節(jié)點(diǎn)供電保護(hù)等有害情況。ProtectionforNodefinationcurrently.VendordesignstheprotectionmethodPowersupplyingtoavoidthecrashorfaultofthenodebecauseofpowersupply,tonodese.g.shortcircuitduringpullingoutorpluginginnodes,inputsurgecurrent,overshootvoltage,theimpacttothepowersupplyofwholerackbecauseoftheshortcircuitofasinglenode.節(jié)點(diǎn)取電方式Nodeconnectingmethodtogetpower維護(hù)。Throughbackplanetosupporthotplugandgetpower,ordirectlygetpowerthroughcopperbusbar;individuallymaintenancebackplane.RMC取電方式RMCconnectingmethodtogetpower通過(guò)背板實(shí)現(xiàn)可熱拔插取電、或者從銅排直接取電。Throughbackplanetosupporthotplugandgetpower,orgetpowerthroughcopperbusbar.交換機(jī)供電PowersupplyforswitchPDU220VAC/240VDCConnectingtothePDU200VAC/240VDCpowersupplyinterfaceusingthecable.散熱模塊(CoolingModule)子項(xiàng)Spec描述組成Components由BMC、RMC、風(fēng)扇控制器、風(fēng)扇、背板等部件組成。BMC,RMC,fancontroller,fan,backplaneetc.制冷模式CoolingMode風(fēng)冷Aircooling風(fēng)流向Airflowdirection前進(jìn)后出Frontinrearout.可正常工作的入風(fēng)口環(huán)境溫度OperatingInletTemperature10℃~35℃采用風(fēng)扇墻UsingFanswall是Yes風(fēng)扇控制器功能FunctionsofFanController按RMC指令控制所管轄的風(fēng)扇的轉(zhuǎn)速。ControllingrotatingspeedofthefansaccrodingtotheRMCinstructions.RMC的風(fēng)扇轉(zhuǎn)速控制策略RMCPolicyofControllingrotatingspeedfansRMCBMC等部件溫度加權(quán)處理而自動(dòng)形成。Supportautomaticandmanualmodes.Theautomaticmodesoperatesbasedontheweightedtemperaturesofthecomponents(CPUetc.)collectedbyBMC.RMCcaseofRMCfancontrollerbroken風(fēng)扇高速運(yùn)轉(zhuǎn)Fansrunninginthehighrotatingspeed風(fēng)扇控制器與RMC連接ConnectionbetweenfancontrollerandRMCRMC通過(guò)專用信道與風(fēng)扇控制器進(jìn)行連接RMCconnectingtofancontrollerthroughadedicatedchannel散熱區(qū)數(shù)量Qtyofcoolingarea暫不定義Nodefinationcurrently風(fēng)扇規(guī)格Modeloffans暫不定義Nodefinationcurrently風(fēng)扇數(shù)量(個(gè))Qty.offans暫不定義Nodefinationcurrently制風(fēng)扇數(shù)量(個(gè)Qtyoffansperfancontroller暫不定義Nodefinationcurrently風(fēng)扇控制器取電方式Methodoffancontrollergetting暫不定義Nodefinationcurrently風(fēng)扇取電方式Methodofgetting在風(fēng)扇控制板上取電Gettingpowerthroughfancontrollerpanel風(fēng)扇電壓Voltageoffan12V每散熱區(qū)風(fēng)扇冗余性RedundantfansincoolingareaN+1風(fēng)扇維護(hù)性Fanmaintenance每個(gè)風(fēng)扇均可實(shí)現(xiàn)單獨(dú)、無(wú)需借助任何工具的拔插維護(hù)。Tool-less,hotpluggale,individualmaintenanceforeveryfan.狀態(tài)指示燈StatusLED風(fēng)扇等內(nèi)部必要部件,正常為綠色常亮,故障為紅色常亮。Forinternalnecessarycomponents:Greenconstantlightfornormalstatus,redconstantlightforerror.風(fēng)扇標(biāo)識(shí)IDID01順序暫不定義。Everyfanshouldhaveclearid. Nodefitionofsequencing防護(hù)ProtectionBackflowpreventiondesign.Onefaultfandoesn'timpactothers服務(wù)器節(jié)點(diǎn)(ServerNode)子項(xiàng)Spec描述組成Node由前面板、節(jié)點(diǎn)、節(jié)點(diǎn)中板,組成。Includefrontpanel,node,nodemidpanel.高度High標(biāo)準(zhǔn)UStanardUsize(1U,2U?,not1.5Uor2.5U)外框Chassis暫不定義Nodefinationcurrently集成口IntergratedInterfacve可選??芍辽俎D(zhuǎn)接為2個(gè)USB口和1個(gè)VGA口。Optional.Whensupported,shouldconvertto2xUSBand1xVGA.指示燈功能Healthstatus時(shí)紅色常亮。Displaycurrenthardwarehealthstatus.GreenwhenstatusisOK,redwhenhardwarefail.RequestUIDLED.UID指示燈需要,且支持本地點(diǎn)燈和遠(yuǎn)程點(diǎn)燈。Needtosupportlocalandremotesetting.節(jié)點(diǎn)尺寸規(guī)格Nodespecifaction暫不定義Nodefinationcurrently節(jié)點(diǎn)與前面板的靈活組合要求Nodeandfrontpanelshouldflexible(1U11U2格的前面板應(yīng)能靈活組合使用。allsizenodeandfrontpanelcombinationshouldbeworkcombination節(jié)點(diǎn)安裝與固定方向Nodelocation暫不定義Nodefinationcurrently節(jié)點(diǎn)維護(hù)方式Nodemaintain硬盤(pán)熱拔插都需要在前方完成。Frontmaintenance.Node,cableing,LED,HDDareallinthefront.節(jié)點(diǎn)管理NodemanagementBMCBMCNC-SIIPMI2.0SNMPtrapdedicateportforBMC,shouldsupportNC-SI,IPMI2.0,SNMPtrapsRMC式NodeandRMCcommnication節(jié)點(diǎn)通過(guò)專用信道與RMC進(jìn)行通信。NodecommicationwithRMCviadedicatedchannel節(jié)點(diǎn)中板的用途Nodemidplanefunction熱拔插連接,包括供電、IDOptional.Ifusenoncustomziedmotherboard,needusemidplanetoconnectbackplane,includepower,ID,signialtranfer.節(jié)點(diǎn)中板規(guī)格Nodemidplane暫不定義Nodefinationcurrently機(jī)柜管理模塊(RMCModule)子項(xiàng)Spec描述RMC管理接口RMCmanageInterfaceconsole1xconsoleforlocalmanage,1xRJ45forremotemanage.*Firmware版本信息監(jiān)控。*輸入電壓,電流監(jiān)控。*輸入總功耗監(jiān)控。*log動(dòng)上報(bào)。*輸出12VDC電壓,電流監(jiān)控。*輸出12VDC總功耗監(jiān)控。*log電源框監(jiān)控Powershelfmonitoring并主動(dòng)上報(bào)。FirmwaremanagementMonitorinputvoltage,currentMonitortotalinputpowerconsumption*Supportinputpowerconsumptionthresholdsetting,ifpowerconsumptionoverthreshold,logtheeventandsendalterautomaticly*Monitoroutput12VDCvoltage,current*Monitoroutput12VDCtotalpowerconsumption*MonitorpowerqualityandSupportinputpowerqualitythresholdsetting,ifpowerconsumptionthreshold,logtheeventandsendalterautomaticly*電源模塊ID信息*電源狀態(tài)監(jiān)控:absent,fail,OVP,OCP,OTP,ok*電源模塊輸入電壓,電流監(jiān)控。*電源模塊輸出電壓,電流監(jiān)控。*log,log電源模塊監(jiān)控監(jiān)控信息主動(dòng)上報(bào)。Powersupply*PowersupplyIDinformationmonitoring*Monitorpowersupplystatus:absent,fail,OVP,OCP,OTP,ok*MonitorpowersupplyinputPowerconsumption*Monitorpowersupplyoutputvoltage,current*AllpowersupplyautomaticworkifRMCfail*RMCLogeventandsendalterifpowersupplyfailorinsert/plug電源模塊休眠功能Powerhibernate可選。RMC故障后所有電源模塊必須開(kāi)啟。Optionalfunction風(fēng)扇控制板監(jiān)控Fancontrollermonitoring風(fēng)扇控制板識(shí)別firmwareRMCfirmwareFancontrolleridentificationFirmwaremanagement風(fēng)扇監(jiān)控FanmonitoringID風(fēng)扇轉(zhuǎn)速監(jiān)控風(fēng)扇轉(zhuǎn)速手動(dòng)控制風(fēng)扇狀態(tài)監(jiān)控:absent,fail,oklog,信息主動(dòng)上報(bào)。FANIDIDidentificationMonitoringfanspeedManualcontrolfanspeedMonitoringfanstatus:absent,fail,okSendalterandlogeventoffanfailure
溫馨提示
- 1. 本站所有資源如無(wú)特殊說(shuō)明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請(qǐng)下載最新的WinRAR軟件解壓。
- 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請(qǐng)聯(lián)系上傳者。文件的所有權(quán)益歸上傳用戶所有。
- 3. 本站RAR壓縮包中若帶圖紙,網(wǎng)頁(yè)內(nèi)容里面會(huì)有圖紙預(yù)覽,若沒(méi)有圖紙預(yù)覽就沒(méi)有圖紙。
- 4. 未經(jīng)權(quán)益所有人同意不得將文件中的內(nèi)容挪作商業(yè)或盈利用途。
- 5. 人人文庫(kù)網(wǎng)僅提供信息存儲(chǔ)空間,僅對(duì)用戶上傳內(nèi)容的表現(xiàn)方式做保護(hù)處理,對(duì)用戶上傳分享的文檔內(nèi)容本身不做任何修改或編輯,并不能對(duì)任何下載內(nèi)容負(fù)責(zé)。
- 6. 下載文件中如有侵權(quán)或不適當(dāng)內(nèi)容,請(qǐng)與我們聯(lián)系,我們立即糾正。
- 7. 本站不保證下載資源的準(zhǔn)確性、安全性和完整性, 同時(shí)也不承擔(dān)用戶因使用這些下載資源對(duì)自己和他人造成任何形式的傷害或損失。
最新文檔
- 沉井泵房施工方案(3篇)
- 2026江蘇無(wú)錫市錫山區(qū)教育系統(tǒng)招聘青年人才120人備考考試試題及答案解析
- 冬季主題策劃活動(dòng)方案(3篇)
- 超市晚場(chǎng)活動(dòng)方案策劃(3篇)
- 實(shí)體餐飲活動(dòng)策劃方案(3篇)
- 2026廣東省疾病預(yù)防控制中心招聘科研助理2人備考考試試題及答案解析
- 2026廣西來(lái)賓市第一中學(xué)招聘編外教師2人備考考試試題及答案解析
- 2026云南師范大學(xué)實(shí)驗(yàn)中學(xué)巫家壩校區(qū)招聘7人備考考試題庫(kù)及答案解析
- 2026年荊州市中心城區(qū)企業(yè)(民辦高校)引進(jìn)人才780人備考考試題庫(kù)及答案解析
- 2026河北省某省級(jí)三甲醫(yī)院現(xiàn)誠(chéng)招肝病科醫(yī)師備考考試題庫(kù)及答案解析
- 輸電線路巡視
- 2025至2030全球及中國(guó)變壓器監(jiān)測(cè)行業(yè)調(diào)研及市場(chǎng)前景預(yù)測(cè)評(píng)估報(bào)告
- 2025年世界職業(yè)院校技能大賽中職組“護(hù)理技能”賽項(xiàng)考試題庫(kù)(含答案)
- 中藥麥冬多糖的提取與免疫調(diào)節(jié)
- 產(chǎn)程中入量管理的研究進(jìn)展
- 08J02 彩色壓型鋼板外墻保溫隔熱建筑構(gòu)造
- 光伏發(fā)電安全管理制度匯編
- 國(guó)際發(fā)展合作署面試輔導(dǎo)
- 電力設(shè)備檢測(cè)方案
- 2020中國(guó)藥典無(wú)水乙醇輔料標(biāo)準(zhǔn)解讀
- 工程造價(jià)英語(yǔ)核心詞匯手冊(cè)
評(píng)論
0/150
提交評(píng)論