A.0.4管樁常用樁型樁身配筋和力學性能表A.0.4-1預應力高強混凝土(PHC)管樁樁身配筋和力學性能見表A.0.4-1。代號外徑D壁厚t(mm)型號樁身配筋構造樁身軸心抗壓力學性能單節(jié)允許長度L(m)預應力鋼棒直徑與數(shù)量(mm)預應力鋼棒面積Aa(mm2)螺旋箍筋直徑和面積(mm)(mm2)管樁橫截面積Amm2x103配筋率(%)預應力鋼棒分布直徑dp(mm)保護層厚度mm管樁截面換算面積A0mm2x103換算截面抵抗矩Wo(mm3x106)理論重量kg/m混凝土有效預壓應力σceN/mm2樁身軸心受壓承載力設計值Rp≤(kN)樁身軸心受壓承載力特征值RVK≤(kN)樁身抱壓允許壓樁力pjmax≤(KN)抱壓式或錘擊式植入法施工抱壓式或錘擊式植入法施工PHC30070A7~116Φ7.1240412.5750.60.472302751.62.4811324.151271154494111441726AB6Φ9.03840.762652.22.5086.37B8Φ9.05121.012652.82.5328.19C8Φ10.77201.422553.62.57210.87PHC40095A7~127Φ9.0448412.57910.493083792.95.9162374.3022882778169520583104AB7Φ10.76300.693693.75.9625.87B7~1310Φ10.79000.993694.86.0308.03C13Φ10.711701.293696.06.10010.01PHC500100A7~1411Φ9.0704519.63125.70.5640637128.610.9233274.8431583835233928414286AB7~1511Φ10.79900.7936129.811.0246.59B11Φ12.613751.0935131.511.1608.75C13Φ12.616251.2935132.511.24710.06PHC500125A7~1412Φ9.0768519.63147.30.5240637150.511.7693834.5337014494274133295024AB7~1512Φ10.710800.7336151.811.8786.18B12Φ12.615001.0235153.612.0268.24C15Φ12.618751.2735155.212.1589.93表A.0.4-1PHC樁樁身配筋和力學性能表(1)代號外徑D壁厚t(mm)型號樁身配筋構造樁身軸心抗壓力學性能單節(jié)允許長度L(m)預應力鋼棒直徑與數(shù)量(mm)預應力鋼棒面積Aa(mm2)螺旋箍筋直徑和面積(mm)(mm2)管樁橫截面積Amm2x103配筋率(%)預應力鋼棒分布直徑dp(mm)保護層厚度mm管樁截面換算面積A0mm2x103換算截面抵抗矩Wo(mm3x106)理論重量kg/m混凝土有效預壓應力σceN/mm2樁身軸心受壓承載力設計值Rp≤(kN)樁身軸心受壓承載力特征值RVK≤(kN)樁身抱壓允許壓樁力pjmax≤(KN)抱壓式或錘擊式植入法施工抱壓式或錘擊式植入法施工PHC600110A7~1514Φ9.0896519.63169.30.5350637173.118.1924404.6042555167315138275775AB14Φ10.712600.7436174.618.3586.26B14Φ12.617501.0335176.718.5818.34C17Φ12.621251.2535178.318.7519.81PHC600130A7~1516Φ9.01024519.63192.00.5350637196.319.4754994.6348245857357343396546AB16Φ10.714400.7536198.019.6646.31B16Φ12.620001.0435200.419.9198.40C20Φ12.625001.3035202.520.14610.12備注:1.管樁混凝土強度等級為C80,?c=35.9N/mm2;預應力鋼筋抗拉強度設計值?py=1000N/mm2;箍筋采用乙級冷拔低碳鋼絲,抗剪計算時強度設計值?yV=320N/mm2;2.樁身軸心受壓承載力設計值未考慮壓屈影響;3.混凝土有效預壓應力計算值按《先張法預應力混凝土管樁》(GB13476)附錄計算;4.預應力鋼筋的有效拉應力=σce(A-Aa/Aa);5.樁身受彎承載力設計值按《混凝土結構設計規(guī)范》(GB50010)附錄計算;6.樁身軸心受壓承載力特征值按樁身軸心受壓承載力設計值除以1.35計算。表A.0.4-1PHC樁樁身配筋和力學性能表(1)(續(xù)表)代號外徑D壁厚t(mm)型號樁身抗彎力學性能樁身抗拉力學性能樁身抗剪力學性能等直徑實心圓截面樁身力學性能按標準組合計算的開裂彎矩Mk≤(kN.m)樁身受彎承載力設計值Rm≤(kN.m)樁身受彎承載力極限值Mu≤(kN.m)按標準組合計算的開裂拉力Rta≤(kN)樁身軸心受拉承載力設計值Qt≤(kN)按標準組合計算的開裂剪力RV≤(kN)樁身受剪承載力設計值RV≤(kN)樁身填芯受剪承載力設計值RV≤(kN)截樁部位受剪承載力設計值RV≤(kN)截樁部位填芯斜截面受剪承載力設計值RV≤(kN)截樁后樁端預應力傳遞長度Ltr(mm)樁身受剪承載力設計值[V]≤(kN)樁身受彎承載力設計值M≤(kN.m)N=0N=0.3fcAρ=1%ρ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表A.0.4-1PHC樁樁身配筋和力學性能表(2)代號外徑D壁厚t(mm)型號樁身抗彎力學性能樁身抗拉力學性能樁身抗剪力學性能等直徑實心圓截面樁身力學性能按標準組合計算的開裂彎矩Mk≤(kN.m)樁身受彎承載力設計值Rm≤(kN.m)樁身受彎承載力極限值Mu≤(kN.m)按標準組合計算的開裂拉力Rta≤(kN)樁身軸心受拉承載力設計值Qt≤(kN)按標準組合計算的開裂剪力RV≤(kN)樁身受剪承載力設計值RV≤(kN)樁身填芯受剪承載力設計值RV≤(kN)截樁部位受剪承載力設計值RV≤(kN)截樁部位填芯斜截面受剪承載力設計值RV≤(kN)截樁后樁端預應力傳遞長度Ltr(mm)樁身受剪承載力設計值[V]≤(kN)樁身受彎承載力設計值M≤(kN.m)N=0N=0.3fcAρ=1%ρ=1.5%PHC600110A191205277796762365311373226288352245330233332AB22427837510941071378337399230292405B26536549314741488394368430233295457C29542357117501806405388450238300443PHC600130A205225304909870414348398250300351245330233332AB24030641312491224429379429254304405B28540254316831700447414464258308457C32347764420502125462441491265315441備注:1.管樁混凝土強度等級為C80,?c=35.9N/mm2;預應力鋼筋抗拉強度設計值?py=1000N/mm2;箍筋采用乙級冷拔低碳鋼絲,抗剪計算時強度設計值?yV=320N/mm2;2.樁身軸心受壓承載力設計值未考慮壓屈影響;3.混凝土有效預壓應力計算值按《先張法預應力混凝土管樁》(GB13476)附錄計算;4.預應力鋼筋的有效拉應力=σce(A-Aa/Aa);5.樁身受彎承載力設計值按《混凝土結構設計規(guī)范》(GB50010)附錄計算;6.填芯混凝土強度等級C30;7.等直徑實心圓截面受剪承載力設計值按《混凝土結構設計規(guī)范》(GB50010)計算,λ=3;D=300mm時,箍筋采用6,其它采用8;箍筋間距S=200mm,混凝土取C30;8.等直徑實心圓截面樁身受彎承載力設計值按全截面配筋率均勻配筋計算,鋼筋抗拉強度設計值fy=360N/m2,混凝土取C30。表A.0.4-1PHC樁樁身配筋和力學性能表(2)(續(xù)表)A.0.4-2厚壁預應力高強混凝土(PHCtk)管樁樁身配筋和力學性能見表A.0.4-2。表A.0.4-2PHCtk樁樁身配筋和力學性能表代號外徑D壁厚t(mm)型號樁身配筋構造樁身軸心抗壓力學性能單節(jié)允許長度L(m)預應力鋼棒直徑與數(shù)量(mm)預應力鋼棒面積Aa(mm2)螺旋箍筋直徑和面積(mm)(mm2)管樁橫截面積Amm2x103配筋率(%)預應力鋼棒分布直徑dp(mm)保護層厚度mm管樁截面換算面積A0mm2x103換算截面抵抗矩Wo(mm3x106)理論重量kg/m混凝土有效預壓應力σceN/mm2樁身軸心受壓承載力設計值Rp≤(kN)樁身軸心受壓承載力特征值RVK≤(kN)樁身抱壓允許壓樁力pjmax≤(KN)抱壓式錘擊式植入法施工抱壓式或錘擊式植入法施工PHCtk400110A7~1210φ7.1400412.57100.170.4029047101.876.1122603.5425173057186422643416AB10φ9.06400.6946102.896.1665.45B7~1310φ10.79000.9045104.06.2247.38C13φ10.711701.1745105.156.2859.23PHCtk500145A7~1412φ9.0768519.63161.630.4838647164.912.1284204.1640624932300836535512AB7~1512φ10.710800.6746166.212.2275.68B12φ12.615000.9345168.012.3607.59C15φ12.618751.1645169.612.4799.18PHCtk600175A7~1516φ9.01024519.63233.540.4748647237.920.9866073.8658697126434752797965AB16φ10.714400.6246239.721.1605.28B16φ12.620000.8645242.121.3957.08C20φ12.625001.0745244.221.6058.58備注:1.管樁混凝土強度等級為C80,?c=35.9N/mm2;預應力鋼筋抗拉強度設計值?py=1000N/mm2;箍筋采用乙級冷拔低碳鋼絲,抗剪計算時強度設計值?yV=320N/mm22.樁身軸心受壓承載力設計值未考慮壓屈影響3.混凝土有效預壓應力計算值按《先張法預應力混凝土管樁》(GB13476)附錄計算4.預應力鋼筋的有效拉應力=σce(A-Aa/Aa)5.樁身受彎承載力設計值按《混凝土結構設計規(guī)范》(GB50010)附錄計算6.填芯混凝土強度等級C30表A.0.4-2PHCtk樁樁身配筋和力學性能表(續(xù)表)代號外徑D壁厚t(mm)型號樁身抗彎力學性能樁身抗拉力學性能樁身抗剪力學性能等直徑實心圓截面樁身力學性能按標準組合計算的開裂彎矩Mk≤(kN.m)樁身受彎承載力設計值Rm≤(kN.m)樁身受彎承載力極限值Mu≤(kN.m)按標準組合計算的開裂拉力Rta≤(kN)樁身軸心受拉承載力設計值Qt≤(kN)按標準組合計算的開裂剪力RV≤(kN)樁身受剪承載力設計值RV≤(kN)樁身填芯受剪承載力設計值RV≤(kN)截樁部位受剪承載力設計值RV≤(kN)截樁部位填芯斜截面受剪承載力設計值RV≤(kN)截樁后樁端預應力傳遞長度Ltr(mm)樁身受剪承載力設計值[V]≤(kN)樁身受彎承載力設計值M≤(kN.m)N=0N=0.3fcAρ=1%ρ=1.5%PHCtk400110A5855734383362111671811271412791281666693AB7086113604540220189203130144346B83115152835764229207221132146396C951411891053993237224238136150381PHCtk500145A122130172686653346295314216235355183241132188AB142178236944918357322341219238409B16723631512751275371352371222241464C18828237815571594382374393228247449PHCtk600175A205211281918870496406433296323357245330233332AB23729038612651224511441468300327412B27838952017141700530483510304331469C31346662620952125546515542312339455備注:1.管樁混凝土強度等級為C80,?c=35.9N/mm2;預應力鋼筋抗拉強度設計值?py=1000N/mm2;箍筋采用乙級冷拔低碳鋼絲,抗剪計算時強度設計值?yV=320N/mm22.樁身軸心受壓承載力設計值未考慮壓屈影響3.混凝土有效預壓應力計算值按《先張法預應力混凝土管樁》(GB13476)附錄計算4.預應力鋼筋的有效拉應力=σce(A-Aa/Aa)5.樁身受彎承載力設計值按《混凝土結構設計規(guī)范》(GB50010)附錄計算6.填芯混凝土強度等級C307.等直徑實心圓截面受剪承載力設計值按《混凝土結構設計規(guī)范》(GB50010)計算,λ=3;D=300mm時,箍筋采用6,其它采用8;箍筋間距S=200mm,混凝土取C30;8.等直徑實心圓截面樁身受彎承載力設計值按全截面配筋率均勻配筋計算,鋼筋抗拉強度設計值fy=360N/m2,混凝土取C30。A.0.4-3厚壁預應力超高強混凝土(PHCts)管樁樁身配筋和力學性能見表A.0.4-3。代號外徑D壁厚t(mm)型號樁身配筋構造樁身軸心抗壓力學性能單節(jié)允許長度L(m)預應力鋼棒直徑與數(shù)量(mm)預應力鋼棒面積Aa(mm2)螺旋箍筋直徑和面積(mm)(mm2)管樁橫截面積Amm2x103配筋率(%)預應力鋼棒分布直徑dp(mm)保護層厚度mm管樁截面換算面積A0mm2x103換算截面抵抗矩Wo(mm3x106)理論重量kg/m混凝土有效預壓應力σceN/mm2樁身軸心受壓承載力設計值Rp≤(kN)樁身軸心受壓承載力特征值RVK≤(kN)樁身抱壓允許壓樁力pjmax≤(KN)抱壓式錘擊式植入法施工抱壓式或錘擊式植入法施工PHCts400110A7~1210φ7.1400412.57100.170.4029047101.876.1082603.5132463942240429204406AB10φ9.06400.6946102.896.1595.45B7~1310φ10.79000.9045104.06.2157.43C13φ10.711701.1745105.156.2729.31PHCts500145A7~1412φ9.0768519.63161.630.4838647164.912.1164204.1552386360388047117109AB7~1512φ10.710800.6746166.212.2115.70B12φ12.615000.9345168.012.3387.63C15φ12.618751.1645169.612.4529.24PHCts600175A7~1516φ9.01024519.63233.540.4748647237.920.9666073.85586971264347527910272AB16φ10.714400.6246239.721.1325.30B16φ12.620000.8645242.121.3567.11C20φ12.625001.0745244.221.5568.63備注:1.管樁混凝土強度等級為C105,?c=46.3N/mm2;預應力鋼筋抗拉強度設計值?py=1000N/mm2;箍筋采用乙級冷拔低碳鋼絲,抗剪計算時強度設計值?yV=320N/mm22.樁身軸心受壓承載力設計值未考慮壓屈影響3.混凝土有效預壓應力計算值按《先張法預應力混凝土管樁》(GB13476)附錄計算4.預應力鋼筋的有效拉應力=σce(A-Aa/Aa)5.樁身受彎承載力設計值按《混凝土結構設計規(guī)范》(GB50010)附錄計算6.填芯混凝土強度等級C30表A.0.4-3PHCts樁樁身配筋和力學性能表代號外徑D壁厚t(mm)型號樁身抗彎力學性能樁身抗拉力學性能樁身抗剪力學性能等直徑實心圓截面樁身力學性能按標準組合計算的開裂彎矩Mk≤(kN.m)樁身受彎承載力設計值Rm≤(kN.m)樁身受彎承載力極限值Mu≤(kN.m)按標準組合計算的開裂拉力Rta≤(kN)樁身軸心受拉承載力設計值Qt≤(kN)按標準組合計算的開裂剪力RV≤(kN)樁身受剪承載力設計值RV≤(kN)樁身填芯受剪承載力設計值RV≤(kN)截樁部位受剪承載力設計值RV≤(kN)截樁部位填芯斜截面受剪承載力設計值RV≤(kN)截樁后樁端預應力傳遞長度Ltr(mm)樁身受剪承載力設計值[V]≤(kN)樁身受彎承載力設計值M≤(kN.m)N=0N=0.3fcAρ=1%ρ=1.5%PHCts400110A6556733573402521872011451592771281666693AB7887114560544260209223147161346B90118155771765269230244150164398C103147194977995278248262154168384PHCts500145A137131173684653411327346245264354183241132188AB157180239944918422356375248267411B18224232112751275436389408251270466C20429238915571594447413432257276452PHCts600175A230213283915870590452479339366356245330233332AB26329439112691224605492519343370414B30439652717181700624537564348375471C34048164121032125640571598355382457備注:1.管樁混凝土強度等級為C105,?c=46.3N/mm2;預應力鋼筋抗拉強度設計值?py=1000N/mm2;箍筋采用乙級冷拔低碳鋼絲,抗剪計算時強度設計值?yV=320N/mm22.樁身軸心受壓承載力設計值未考慮壓屈影響3.混凝土有效預壓應力計算值按《先張法預應力混凝土管樁》(GB13476)附錄計算4.預應力鋼筋的有效拉應力=σce(A-Aa/Aa)5.樁身受彎承載力設計值按《混凝土結構設計規(guī)范》(GB50010)附錄計算6.填芯混凝土強度等級C307.等直徑實心圓截面受剪承載力設計值按《混凝土結構設計規(guī)范》(GB50010)計算,λ=3;D=300mm時,箍筋采用6,其它采用8;箍筋間距S=200mm,混凝土取C30;8.等直徑實心圓截面樁身受彎承載力設計值按全截面配筋率均勻配筋計算,鋼筋抗拉強度設計值fy=360N/m2,混凝土取C30。表A.0.4-3PHCts樁樁身配筋和力學性能表(續(xù)表)A.0.4-4薄壁預應力高強混凝土(PHCtn)管樁樁身配筋和力學性能見表A.0.4-4。代號外徑D壁厚t(mm)型號樁身配筋構造樁身軸心抗壓力學性能單節(jié)允許長度L(m)預應力鋼棒直徑與數(shù)量(mm)預應力鋼棒面積Aa(mm2)螺旋箍筋直徑和面積(mm)(mm2)管樁橫截面積Amm2x103配筋率(%)預應力鋼棒分布直徑dp(mm)保護層厚度mm管樁截面換算面積A0mm2x103換算截面抵抗矩Wo(mm3x106)理論重量kg/m混凝土有效預壓應力σceN/mm2樁身軸心受壓承載力設計值Rp≤(kN)樁身軸心受壓承載力特征值RVK≤(kN)樁身抱壓允許壓樁力pjmax≤(KN)抱壓式錘擊式植入法施工抱壓式或錘擊式植入法施工PHCtn30055A≤95φ7.1200412.5742.30.472402243.162.2641104.11106312917879561443PHCtn40065A≤106φ7.1240412.5768.70.353302769.405.0461783.1117182086127215452332AB10-126φ9.03840.562670.015.0884.84PHCtn50065A<108φ7.1320412.5788.780.364302790.158.7142303.1922312709165220063028AB10-148φ9.05120.584402690.978.7904.96備注:1.管樁混凝土強度等級為C80,?c=35.6N/mm2;預應力鋼筋抗拉強度設計值?py=1000N/mm2;箍筋采用乙級冷拔低碳鋼絲,抗剪計算時強度設計值?yV=320N/mm22.樁身軸心受壓承載力設計值未考慮壓屈影響3.混凝土有效預壓應力計算值按《先張法預應力混凝土管樁》(GB13476)附錄計算4.預應力鋼筋的有效拉應力=σce(A-Aa/Aa)5.樁身受彎承載力設計值按《混凝土結構設計規(guī)范》(GB50010)附錄計算6.填芯混凝土強度等級C307.本樁型箍筋加密區(qū)長度500mm;箍筋加密區(qū)間距50±5mm;非加密區(qū)間距150±5mm表A.0.4-4PHCtn樁樁身配筋和力學性能表表A.0.4-4PHCtn樁樁身配筋和力學性能表(續(xù)表)代號外徑D壁厚t(mm)型號樁身抗彎力學性能樁身抗拉力學性能樁身抗剪力學性能等直徑實心圓截面樁身力學性能按標準組合計算的開裂彎矩Mk≤(kN.m)樁身受彎承載力設計值Rm≤(kN.m)樁身受彎承載力極限值Mu≤(kN.m)按標準組合計算的開裂拉力Rta≤(kN)樁身軸心受拉承載力設計值Qt≤(kN)按標準組合計算的開裂剪力RV≤(kN)樁身受剪承載力設計值RV≤(kN)樁身填芯受剪承載力設計值RV≤(kN)截樁部位受剪承載力設計值RV≤(kN)截樁部位填芯斜截面受剪承載力設計值RV≤(kN)截樁后樁端預應力傳遞長度Ltr(mm)樁身受剪承載力設計值[V]≤(kN)樁身受彎承載力設計值M≤(kN.m)N=0N=0.3fcAρ=1%ρ=1.5%PHCtn30055A232435177170908095627727864852839PHCtn40065A4640592162041431331641101412791281666693AB556291339326148146177111142349PHCtn50065A7969103288272186171230140199279183241132188AB96108157451435193187246142201348備注:1.管樁混凝土強度等級為C80,?c=35.6N/mm2;預應力鋼筋抗拉強度設計值?py=1000N/mm2;箍筋采用乙級冷拔低碳鋼絲,抗剪計算時強度設計值?yV=320N/mm22.樁身軸心受壓承載力設計值未考慮壓屈影響3.混凝土有效預壓應力計算值按《先張法預應力混凝土管樁》(GB13476)附錄計算4.預應力鋼筋的有效拉應力=σce(A-Aa/Aa)5.樁身受彎承載力設計值按《混凝土結構設計規(guī)范》(GB50010)附錄計算6.填芯混凝土強度等級C307.本樁型箍筋加密區(qū)長度500mm;箍筋加密區(qū)間距50±5mm;非加密區(qū)間距150±5mm8.等直徑實心圓截面受剪承載力設計值按《混凝土結構設計規(guī)范》(GB50010)計算,λ=3;D=300mm時,箍筋采用6,其它采用8;箍筋間距S=200mm,混凝土取C30;9.等直徑實心圓截面樁身受彎承載力設計值按全截面配筋率均勻配筋計算,鋼筋抗拉強度設計值fy=360N/m2,混凝土取C30。A.0.4-5預應力混凝土方箱形截面樁(PHS)樁身配筋和力學性能見表A.0.4.5。代號邊長B內徑D(mm)型號樁身配筋構造樁身軸心抗壓力學性能單節(jié)允許長度L(m)預應力鋼棒直徑與數(shù)量(mm)預應力鋼棒面積Aa(mm2)螺旋箍筋直徑和面積(mm)(mm2)方樁橫截面積Amm2x103配筋率(%)預應力鋼棒分布邊長Bp(mm)保護層厚度mm方樁截面換算面積A0mm2x103換算截面抵抗矩Wo(mm3x106)理論重量kg/m混凝土有效預壓應力σceN/mm2樁身軸心受壓承載力設計值Rp≤(kN)樁身軸心受壓承載力特征值RVK≤(kN)樁身抱壓允許壓樁力pjmax≤(KN)抱壓式或錘擊式植入法施工抱壓式或錘擊式植入法施工PHS300160A7~108Φ7.1320412.5769.90.462302771.34.3761793.8417562133130115802384AB8Φ9.05120.732672.14.4305.96B8Φ10.77201.032573.04.4898.12PHS350170A7~118Φ9.0512412.5799.80.5125738102.07.0662504.2825083045185822563404AB8Φ10.77200.7237102.97.1295.88B8Φ12.610001.0036104.17.2147.92PHS400220A7~128Φ9.0512412.57122.00.4230738124.210.2853053.5530663722227127574160AB8Φ10.77200.5937125.110.3634.90B8Φ12.610000.8236126.310.4696.64PHS450260A7~1312Φ9.0768412.57149.40.5135738152.714.5173744.3037554559278133775096AB12Φ10.710800.7237154.014.6505.91B12Φ12.615001.0036155.814.8287.97PHS500310A7~1312Φ9.0768519.63174.60.4440737177.819.4024363.7243865326324939455952AB12Φ10.710800.6236179.119.5575.13B12Φ12.615000.8635180.919.7666.94表A.0.4-5PHS樁樁身配筋和力學性能表(1)代號邊長B內徑D(mm)型號樁身配筋構造樁身軸心抗壓力學性能單節(jié)允許長度L(m)預應力鋼棒直徑與數(shù)量(mm)預應力鋼棒面積Aa(mm2)螺旋箍筋直徑和面積(mm)(mm2)方樁橫截面積Amm2x103配筋率(%)預應力鋼棒分布邊長Bp(mm)保護層厚度mm方樁截面換算面積A0mm2x103換算截面抵抗矩Wo(mm3x106)理論重量kg/m混凝土有效預壓應力σceN/mm2樁身軸心受壓承載力設計值Rp≤(kN)樁身軸心受壓承載力特征值RVK≤(kN)樁身抱壓允許壓樁力pjmax≤(KN)抱壓式或錘擊式植入法施工抱壓式或錘擊式植入法施工PHS550310A7~1416Φ9.01024519.63227.10.4545737231.426.6515683.8157056928422651327743AB16Φ10.714400.6336233.226.8825.25B16Φ12.620000.8835235.627.1947.10PHS600360A7~1520Φ9.01280519.63258.30.5050737263.734.0476464.1664897879480758378806AB20Φ10.718000.7036265.934.3705.73B20Φ12.625000.9735268.934.8057.73備注:1.管樁混凝土強度等級為C80,?c=35.6N/mm2;預應力鋼筋抗拉強度設計值?py=1000N/mm2;箍筋采用乙級冷拔低碳鋼絲,抗剪計算時強度設計值?yV=320N/mm22.樁身軸心受壓承載力設計值未考慮壓屈影響3.預應力損失及混凝土有效預壓應力計算值按《預應力混凝土空心方樁》(JG/T197)有關條文計算4.樁身軸心受壓承載力特征值RVK=樁身軸心受壓承載力設計值Rp/1.355.單節(jié)允許長度最大值為兩端勾吊法起吊控制值表A.0.4-5PHS樁樁身配筋和力學性能表(1)(續(xù)表)代號邊長B內徑D(mm)型號樁身抗彎力學性能樁身抗拉力學性能樁身抗剪力學性能等邊長實心方截面樁身力學性能按標準組合計算的開裂彎矩Mk≤(kN.m)樁身受彎承載力設計值Rm≤(kN.m)樁身受彎承載力極限值Mu≤(kN.m)按標準組合計算的開裂拉力Rta≤(kN)樁身軸心受拉承載力設計值Qt≤(kN)按標準組合計算的開裂剪力RV≤(kN)樁身受剪承載力設計值RV≤(kN)樁身填芯受剪承載力設計值RV≤(kN)截樁部位受剪承載力設計值RV≤(kN)填芯部位填芯斜截面受剪承載力設計值RV≤(kN)截樁后樁端預應力傳遞長度Ltr(mm)樁身受剪承載力設計值[V]≤(kN)樁身受彎承載力設計值M≤(kN.m)N=0N=0.3fcAρ=1%ρ=1.5%PHS300160A1738492742729376876576267851352341AB26607943043510084956677327B3686123593612109921036677376PHS350170A307092436435131107119881013361151844053AB429912960561214011512889101390B5713819782585015112613990102444PHS400220A37801064414351491211421021233411492396483AB51113148613612158130150103124397B69166206838850169141162104124455PHS450260A6213617365765318515017912715633718730198123AB87192243911918197163192129158391B11827439212421275214180209131160446PHS500310A72152193661653224186227162204341230370140176AB100214271919918237199240164205397B13729737612551275254215257166208454表A.0.4-5PHS樁樁身配筋和力學性能表(2)代號邊長B內徑D(mm)型號樁身抗彎力學性能樁身抗拉力學性能樁身抗剪力學性能等邊長實心方截面樁身力學性能按標準組合計算的開裂彎矩Mk≤(kN.m)樁身受彎承載力設計值Rm≤(kN.m)樁身受彎承載力極限值Mu≤(kN.m)按標準組合計算的開裂拉力Rta≤(kN)樁身軸心受拉承載力設計值Qt≤(kN)按標準組合計算的開裂剪力RV≤(kN)樁身受剪承載力設計值RV≤(kN)樁身填芯受剪承載力設計值RV≤(kN)截樁部位受剪承載力設計值RV≤(kN)填芯部位填芯斜截面受剪承載力設計值RV≤(kN)截樁后樁端預應力傳遞長度Ltr(mm)樁身受剪承載力設計值[V]≤(kN)樁身受彎承載力設計值M≤(kN.m)N=0N=0.3fcAρ=1%ρ=1.5%PHS550310A101224278881870295241283210252340277447159239AB14131539112231224312259300213254396B19345954216721700335281322216257453PHS600360A14230637810981088331272328233289339328530212267AB19743053115231530352293349236292393B26972173620782125380321376240296448備注:1.管樁混凝土強度等級為C80,?c=35.6N/mm2;預應力鋼筋抗拉強度設計值?py=1000N/mm2;箍筋采用乙級冷拔低碳鋼絲,抗剪計算時強度設計值?yV=320N/mm22.預應力損失及混凝土有效預壓應力計算值按《預應力混凝土空心方樁》(JG/T197)有關條文計算3.樁身填芯受剪承載力設計值=樁身受剪承載力設計值+填芯混凝土抗剪承載力設計值,按C30混凝土填芯計算4.按標準組合計算的開裂彎矩為裂縫控制等級一級時數(shù)值5.等邊長實心方樁混凝土強度等級為C406.填芯混凝土強度等級C307.等邊長實心方樁截面受剪承載力設計值按《混凝土結構設計規(guī)范》(GB50010)計算,λ=3;B=300mm時,箍筋采用6,其它采用8;箍筋間距S=200mm;8..等邊長實心方樁截面樁身受彎承載力設計值按全截面配筋率均勻配筋計算,鋼筋抗拉強度設計值fy=360N/m2。表A.0.4-5PHS樁樁身配筋和力學性能表(2)(續(xù)表)A.0.4-6厚壁式高強預應力混凝土方箱形截面樁(PHStk)樁身配筋和力學性能見表A.0.4.6。代號邊長B內徑D(mm)型號樁身配筋構造樁身軸心抗壓力學性能單節(jié)允許長度L(m)預應力鋼棒直徑與數(shù)量(mm)預應力鋼棒面積Aa(mm2)螺旋箍筋直徑和面積(mm)(mm2)方樁橫截面積Amm2x103配筋率(%)預應力鋼棒分布邊長Bp(mm)保護層厚度mm方樁截面換算面積A0mm2x103換算截面抵抗矩Wo(mm3x106)理論重量kg/m混凝土有效預壓應力σceN/mm2樁身軸心受壓承載力設計值Rp≤(kN)樁身軸心受壓承載力特征值RVK≤(kN)樁身抱壓允許壓樁力pjmax≤(KN)抱壓式或錘擊式植入法施工抱壓式或錘擊式植入法施工PHStk350160A7~118Φ9.0512412.57102.40.5024842104.67.1062664.1725733125190623143492AB8Φ10.77200.7041105.57.1655.74B8Φ12.610000.9840106.77.2447.74PHStk400195A7~118Φ9.0512412.57130.20.3928847132.310.4823393.3432703971242229424438AB8Φ10.77200.5546133.210.5514.61B8Φ12.610000.7745134.410.6446.26PHStk450220A7~1212Φ9.0768412.57164.50.4733847167.814.9694283.9341345019306237185610AB12Φ10.710800.6646169.115.0885.41B12Φ12.615000.9145170.915.2487.31PHStk500240A7~1212Φ9.0768519.63204.80.3838647208.020.5255333.1951466248381246286983AB12Φ10.710800.5346209.420.6654.42B12Φ12.615000.7345211.220.8536.00備注:1.管樁混凝土強度等級為C80,?c=35.6N/mm2;預應力鋼筋抗拉強度設計值?py=1000N/mm2;箍筋采用乙級冷拔低碳鋼絲,抗剪計算時強度設計值?yV=320N/mm22.樁身軸心受壓承載力設計值未考慮壓屈影響3.預應力損失及混凝土有效預壓應力計算值按《預應力混凝土空心方樁》(JG/T197)有關條文計算4.樁身軸心受壓承載力特征值RVK=樁身軸心受壓承載力設計值Rp/1.355.單節(jié)允許長度最大值為兩端勾吊法起吊控制值表A.0.4-6PHStk樁樁身配筋和力學性能表(1)代號邊長B內徑D(mm)型號樁身抗彎力學性能樁身抗拉力學性能樁身抗剪力學性能等邊長實心方截面樁身力學性能按標準組合計算的開裂彎矩Mk≤(kN.m)樁身受彎承載力設計值Rm≤(kN.m)樁身受彎承載力極限值Mu≤(kN.m)按標準組合計算的開裂拉力Rta≤(kN)樁身軸心受拉承載力設計值Qt≤(kN)按標準組合計算的開裂剪力RV≤(kN)樁身受剪承載力設計值RV≤(kN)樁身填芯受剪承載力設計值RV≤(kN)截樁部位受剪承載力設計值RV≤(kN)填芯部位填芯斜截面受剪承載力設計值RV≤(kN)截樁后樁端預應力傳遞長度Ltr(mm)樁身受剪承載力設計值[V]≤(kN)樁身受彎承載力設計值M≤(kN.m)N=0N=0.3fcAρ=1%ρ=1.5%PHStk350160A307091437435134109120901013371151844053AB4110512960561214311712891102391B5613719582685015412813992103445PHStk400195A35801054424351591281441091253421492396483AB49112147614612168137153110126399B67165204841850179148164111127458PHStk450220A5913517265965320616518614216333918730198123AB82190242915918218178199144165394B11127138712491275235195215146167451PHStk500240A66151192664653268217241193218344230370140176AB91212270924918281230254195220401B12529537412661275298247272197222461備注:1.管樁混凝土強度等級為C80,?c=35.6N/mm2;預應力鋼筋抗拉強度設計值?py=1000N/mm2;箍筋采用乙級冷拔低碳鋼絲,抗剪計算時強度設計值?yV=320N/mm22.預應力損失及混凝土有效預壓應力計算值按《預應力混凝土空心方樁》(JG/T197)有關條文計算3.樁身填芯受剪承載力設計值=樁身受剪承載力設計值+填芯混凝土抗剪承載力設計值,按C30混凝土填芯計算4.按標準組合計算的開裂彎矩為裂縫控制等級一級時數(shù)值5.等邊長實心方樁混凝土強度等級為C406.填芯混凝土強度等級C307.等邊長實心方樁截面受剪承載力設計值按《混凝土結構設計規(guī)范》(GB50010)計算,λ=3;B=300mm時,箍筋采用6,其它采用8;箍筋間距S=200mm;8..等邊長實心方樁截面樁身受彎承載力設計值按全截面配筋率均勻配筋計算,鋼筋抗拉強度設計值fy=360N/m2。表A.0.6-6PHStk樁樁身配筋和力學性能表(2)A.0.4-7厚壁式超高強預應力混凝土方箱形截面樁(PHSts)樁身配筋和力學性能見表A.0.4-7。代號邊長B內徑D(mm)型號樁身配筋構造樁身軸心抗壓力學性能單節(jié)允許長度L(m)預應力鋼棒直徑與數(shù)量(mm)預應力鋼棒面積Aa(mm2)螺旋箍筋直徑和面積(mm)(mm2)方樁橫截面積Amm2x103配筋率(%)預應力鋼棒分布邊長Bp(mm)保護層厚度mm方樁截面換算面積A0mm2x103換算截面抵抗矩Wo(mm3x106)理論重量kg/m混凝土有效預壓應力σceN/mm2樁身軸心受壓承載力設計值Rp≤(kN)樁身軸心受壓承載力特征值RVK≤(kN)樁身抱壓允許壓樁力pjmax≤(KN)抱壓式或錘擊式植入法施工抱壓式或錘擊式植入法施工PHSts350160A7~128Φ9.0512412.57102.40.5024842104.57.0992664.2233194030245829854504AB8Φ10.77200.7041105.37.1555.83B8Φ12.610000.9840106.57.2307.90PHSts400195A7~128Φ9.0512412.57130.20.3928847132.210.4743393.3742185121312437945724AB8Φ10.77200.5546133.110.5404.67B8Φ12.610000.7745134.210.6286.36PHSts450220A7~1312Φ9.0768412.57164.50.4733847167.614.9554283.9753316473394947957235AB12Φ10.710800.6646168.915.0695.49B12Φ12.615000.9145170.615.2217.45PHSts500240A7~1312Φ9.0768519.63204.80.3838647207.920.5095333.2266368058491659699006AB12Φ10.710800.5346209.120.6424.47B12Φ12.615000.7345210.920.8216.09備注:1.管樁混凝土強度等級為C105,?c=46.3N/mm2;預應力鋼筋抗拉強度設計值?py=1000N/mm2;箍筋采用乙級冷拔低碳鋼絲,抗剪計算時強度設計值?yV=320N/mm22.樁身軸心受壓承載力設計值未考慮壓屈影響3.預應力損失及混凝土有效預壓應力計算值按《預應力混凝土空心方樁》(JG/T197)有關條文計算4.樁身軸心受壓承載力特征值RVK=樁身軸心受壓承載力設計值Rp/1.355.單節(jié)允許長度最大值為兩端勾吊法起吊控制值表A.0.4-7PHSts樁樁身配筋和力學性能表(1)`代號邊長B內徑D(mm)型號樁身抗彎力學性能樁身抗拉力學性能樁身抗剪力學性能等邊長實心方截面樁身力學性能按標準組合計算的開裂彎矩Mk≤(kN.m)樁身受彎承載力設計值Rm≤(kN.m)樁身受彎承載力極限值Mu≤(kN.m)按標準組合計算的開裂拉力Rta≤(kN)樁身軸心受拉承載力設計值Qt≤(kN)按標準組合計算的開裂剪力RV≤(kN)樁身受剪承載力設計值RV≤(kN)樁身填芯受剪承載力設計值RV≤(kN)截樁部位受剪承載力設計值RV≤(kN)填芯部位填芯斜截面受剪承載力設計值RV≤(kN)截樁后樁端預應力傳遞長度Ltr(mm)樁身受剪承載力設計值[V]≤(kN)樁身受彎承載力設計值M≤(kN.m)N=0N=0.3fcAρ=1%ρ=1.5%PHSts350160A3072944414351531221331041152821151844053AB42107131614612161131142105116329B57142201841850173142153106117377PHSts400195A35821074454351821441611261422861492396483AB49115151621612191153170127143335B68169239853850203165181128144386PHSts450220A5913817766565323518620716518628418730198123AB83195248926918248199220167188332B11328039712711275265217237170191381PHSts500240A66154197669653305243268222246287230370140176AB92217277934918318257281224249336B12730138412841275336274299227251388備注:1.管樁混凝土強度等級為C105,?c=46.3N/mm2;預應力鋼筋抗拉強度設計值?py=1000N/mm2;箍筋采用乙級冷拔低碳鋼絲,抗剪計算時強度設計值?yV=320N/mm22.預應力損失及混凝土有效預壓應力計算值按《預應力混凝土空心方樁》(JG/T197)有關條文計算3.樁身填芯受剪承載力設計值=樁身受剪承載力設計值+填芯混凝土抗剪承載力設計值,按C30混凝土填芯計算4.按標準組合計算的開裂彎矩為裂縫控制等級一級時數(shù)值5.等邊長實心方樁混凝土強度等級為C406.填芯混凝土強度等級C307.等邊長實心方樁截面受剪承載力設計值按《混凝土結構設計規(guī)范》(GB50010)計算,λ=3;B=300mm時,箍筋采用6,其它采用8;箍筋間距S=200mm;8..等邊長實心方樁截面樁身受彎承載力設計值按全截面配筋率均勻配筋計算,鋼筋抗拉強度設計值fy=360N/m2。表A.0.4-7PHSts樁樁身配筋和力學性能表(2)A.0.4-8高強混凝土薄壁空心方箱形截面樁(PHStn)樁身配筋和力學性能見表A.0.4-8。代號邊長B內徑D(mm)型號樁身配筋構造樁身軸心抗壓力學性能單節(jié)允許長度L(m)預應力鋼棒直徑與數(shù)量(mm)預應力鋼棒面積Aa(mm2)螺旋箍筋直徑和面積(mm)(mm2)方樁橫截面積Amm2x103配筋率(%)預應力鋼棒分布邊長Bp(mm)保護層厚度mm方樁截面換算面積A0mm2x103換算截面抵抗矩Wo(mm3x106)理論重量kg/m混凝土有效預壓應力σceN/mm2樁身軸心受壓承載力設計值Rp≤(kN)樁身軸心受壓承載力特征值RVK≤(kN)樁身抱壓允許壓樁力pjmax≤(KN)抱壓式或錘擊式植入法施工抱壓式或錘擊式植入法施工PHStn300170A7~94Φ7.1160412.5767.30.242302768.04.2871752.0416912054125315212295AB4Φ9.02560.382668.44.3233.22備注:1.管樁混凝土強度等級為C80,?c=35.6N/mm2;預應力鋼筋抗拉強度設計值?py=1000N/mm2;箍筋采用乙級冷拔低碳鋼絲,抗剪計算時強度設計值?yV=320N/mm22.樁身軸心受壓承載力設計值未考慮壓屈影響3.預應力損失及混凝土有效預壓應力計算值按《預應力混凝土空心方樁》(JG/T197)有關條文計算4.樁身軸心受壓承載力特征值RVK=樁身軸心受壓承載力設計值Rp/1.355.單節(jié)允許長度最大值為兩端勾吊法起吊控制值表A.0.4-8PHStn樁樁身配筋和力學性能表(1)代號邊長B內徑D(mm)型號樁身抗彎力學性能樁身抗拉力學性能樁身抗剪力學性能等邊長實心方截面樁身力學性能按標準組合計算的開裂彎矩Mk≤(kN.m)樁身受彎承載力設計值Rm≤(kN.m)樁身受彎承載力極限值Mu≤(kN.m)按標準組合計算的開裂拉力Rta≤(kN)樁身軸心受拉承載力設計值Qt≤(kN)按標準組合計算的開裂剪力RV≤(kN)樁身受剪承載力設計值RV≤(kN)樁身填芯受剪承載力設計值RV≤(kN)截樁部位受剪承載力設計值RV≤(kN)填芯部位填芯斜截面受剪承載力設計值RV≤(kN)截樁后樁端預應力傳遞長度Ltr(mm)樁身受剪承載力設計值[V]≤(kN)樁身受彎承載力設計值M≤(kN.m)N=0N=0.3fcAρ=1%ρ=1.5%PHStn300170A918261391368267796173274851352341AB1430422202188671836174342備注:1.管樁混凝土強度等級為C80,?c=35.6N/mm2;預應力鋼筋抗拉強度設計值?py=1000N/mm2;箍筋采用乙級冷拔低碳鋼絲,抗剪計算時強度設計值?yV=320N/mm22.預應力損失及混凝土有效預壓應力計算值按《預應力混凝土空心方樁》(JG/T197)有關條文計算3.樁身填芯受剪承載力設計值=樁身受剪承載力設計值+填芯混凝土抗剪承載力設計值,按C30混凝土填芯計算4.按標準組合計算的開裂彎矩為裂縫控制等級一級時數(shù)值5.等邊長實心方樁混凝土強度等級為C406.填芯混凝土強度等級C307.等邊長實心方樁截面受剪承載力設計值按《混凝土結構設計規(guī)范》(GB50010)計算,λ=3;B=300mm時,箍筋采用6,其它采用8;箍筋間距S=200mm;8..等邊長實心方樁截面樁身受彎承載力設計值按全截面配筋率均勻配筋計算,鋼筋抗拉強度設計值fy=360N/m2。表A.0.4-8PHStn樁樁身配筋和力學性能表(2)PAGEPAGE0附錄B按樁頂水平位移控制的單樁水平承載力特征值計算表B.0.1當樁的水平承載力由水平位移控制時,PHC管樁可按表B.0.1估算單樁水平承載力特征值。表B.0.1PHC單樁水平承載力特征值估算表(樁頂位移10mm控制)m(MN/m4)α(l/m)樁頂約束情況樁換算埋深(αh)Rha(kN)m(MN/m4)α(l/m)樁頂約束情況樁換算埋深(αh)Rha(kN)PHC-300-AB-70PHC-400-AB-9520.676鉸接自由4.011.51020.552鉸接自由4.019.9413.010.3033.017.8502.47.9682.413.805固接4.029.890固接4.051.7833.027.3313.047.3502.425.6592.444.45340.776鉸接自由4.017.44640.634鉸接自由4.030.2253.015.6173.027.0552.412.0782.420.924固接4.045.304固接4.078.4883.041.4263.071.7692.438.8922.467.37860.842鉸接自由4.022.25160.688鉸接自由4.038.5503.019.9183.034.5062.415.4042.426.687固接4.057.782固接4.0100.1063.052.8363.091.5372.449.6032.485.936100.932鉸接自由4.030.232100.762鉸接自由4.052.3763.027.0613.046.8822.420.9292.436.259固接4.078.506固接4.0136.0093.071.7863.0124.3672.467.3942.4116.757151.011鉸接自由4.038.558150.826鉸接自由4.066.8013.034.5153.059.7952.426.6932.446.245固接4.0100.129固接4.0173.4703.091.5583.0158.6202.485.9552.4148.915201.071鉸接自由4.045.823200.875鉸接自由4.079.3873.041.0173.071.0612.431.7232.454.958固接4.0118.993*固接4.0206.152*3.0108.807*3.0188.504*2.4102.1502.4176.970*251.120鉸接自由4.052.398250.915鉸接自由4.090.7783.046.9033.081.2572.436.2742.462.844固接4.0136.068*固接4.0235.732*3.0124.420*3.0215.553*2.4116.807*2.4202.364*301.161鉸接自由4.058.455300.949鉸接自由4.0101.2723.052.3253.090.6502.440.4682.470.109固接4.0151.797*固接4.0262.983*3.0138.803*3.0240.471*2.4130.310*2.4225.757*351.197鉸接自由4.064.120350.979鉸接自由4.0111.0853.057.3953.099.4352.444.3892.476.903固接4.0166.507*固接4.0288.466*3.0152.253*3.0263.773*2.4142.937*2.4247.633*401.230鉸接自由4.069.468401.005鉸接自由4.0120.3513.062.1833.0107.7292.448.0922.483.317固接4.0180.396*固接4.0312.529*3.0164.953*3.0285.776*2.4154.860*2.4268.290*451.259鉸接自由4.074.555451.029鉸接自由4.0129.1643.066.7363.0115.6182.451.6142.489.419固接4.0193.606*固接4.0335.415*3.0177.032*3.0306.702*2.4166.200*2.4287.936*備注:1.m—樁側土水平抗力系數(shù)的比例系數(shù);α—樁的水平變形系數(shù);Rha—單樁水平承載力特征值。2.帶*號數(shù)值表示單樁水平承載力特征值已超過表A.0.4中樁身受剪承載力設計值。表B.0.1(續(xù)表)PHC單樁水平承載力特征值估算表(樁頂位移10mm控制)m(MN/m4)α(l/m)樁頂約束情況樁換算埋深(αh)Rha(kN)m(MN/m4)α(l/m)樁頂約束情況樁換算埋深(αh)Rha(kN)PHC-500-AB-100PHC-500-AB-12520.479鉸接自由4.030.10220.472鉸接自由4.031.0143.026.9453.027.7622.420.8392.421.471固`接4.078.169固接4.080.5393.071.4773.073.6442.467.1042.469.13840.550鉸接自由4.045.62640.542鉸接自由4.047.0093.040.8413.042.0792.431.5862.432.544固接4.0118.482固接4.0122.0743.0108.3393.0111.6242.4101.7102.4104.79460.597鉸接自由4.058.19260.588鉸接自由4.059.9573.052.0893.053.6692.440.2862.441.507固接4.0151.115固接4.0155.6963.0138.1793.0142.3682.4129.7242.4133.657100.661鉸接自由4.079.063100.651鉸接自由4.081.4603.070.7713.072.9172.454.7342.456.394固接4.0205.312固接4.0211.5373.0187.7373.0193.4292.4176.2502.4181.593150.717鉸接自由4.0100.839150.706鉸接自由4.0103.8973.090.2643.093.0002.469.8102.471.926固接4.0261.860固接4.0269.8003.0239.4443.0246.7042.4224.7932.4231.609200.760鉸接自由4.0119.838200.748鉸接自由4.0123.4713.0107.2693.0110.5222.482.9622.485.477固接4.0311.195*固接4.0320.630*3.0284.556*3.0293.1832.4267.145*2.4275.244250.794鉸接自由4.0137.033250.782鉸接自由4.0141.1873.0122.6613.0126.3802.494.8662.497.742固接4.0355.848*固接4.0366.637*3.0325.386*3.0335.251*2.4305.477*2.4314.738*300.824鉸接自由4.0152.874300.811鉸接自由4.0157.5093.0136.8413.0140.9902.4105.8322.4109.041固接4.0396.984*固接4.0409.020*3.0363.001*3.0374.007*2.4340.790*2.4351.122*350.849鉸接自由4.0167.688350.837鉸接自由4.0172.7723.0150.1013.0154.6522.4116.0882.4119.607固接4.0435.453*固接4.0448.655*3.0398.177*3.0410.249*2.4373.814*2.4385.147*400.872鉸接自由4.0181.676400.859鉸接自由4.0187.1843.0162.6223.0167.5522.4125.7712.4129.585固接4.0471.777*固接4.0486.080*3.0431.391*3.0444.470*2.4404.996*2.4417.274*450.893鉸接自由4.0194.979450.880鉸接自由4.0200.8903.0174.5303.0179.8222.4134.9812.4139.074固接4.0506.323*固接4.0521.674*3.0462.981*3.0477.017*2.4434.652*2.4447.830*備注:1.m—樁側土水平抗力系數(shù)的比例系數(shù);α—樁的水平變形系數(shù);Rha—單樁水平承載力特征值。2.帶*號數(shù)值表示單樁水平承載力特征值已超過表A.0.4中樁身受剪承載力設計值。表B.0.1(續(xù)表)PHC單樁水平承載力特征值估算表(樁頂位移10mm控制)m(MN/m4)α(l/m)樁頂約束情況樁換算埋深(αh)Rha(kN)m(MN/m4)α(l/m)樁頂約束情況樁換算埋深(αh)Rha(kN)PHC-600-AB-110PHC-600-AB-13020.427鉸接自由4.042.50020.421鉸接自由4.043.6853.038.0433.039.1042.429.4222.430.243固接4.0110.365固接4.0113.4433.0100.9183.0103.7322.494.7432.497.38440.490鉸接自由4.064.41940.484鉸接自由4.066.2153.057.6633.059.2702.444.5962.445.839固接4.0167.283固接4.0171.9473.0152.9633.0157.2282.4143.6032.4147.60760.532鉸接自由4.082.16160.524鉸接自由4.084.4523.073.5443.075.5952.456.8792.458.465固接4.0213.357固接4.0219.3053.0195.0933.0200.5322.4183.1552.4188.262100.589鉸接自由4.0111.629100.581鉸接自由4.0114.7413.099.9213.0102.7072.477.2792.479.433固接4.0289.878固接4.0297.9603.0265.0643.0272.4542.4248.8452.4255.783150.639鉸接自由4.0142.374150.630鉸接自由4.0146.3433.0127.4423.0130.9952.498.5632.4101.311固接4.0369.717固接4.0380.0253.0338.0693.0347.4942.4317.3832.4326.232200.676鉸接自由4.0169.197200.667鉸接自由4.0173.9153.0151.4523.0155.6752.4117.1332.4120.399固接4.0439.373*固接4.0451.623*3.0401.761*3.0412.963*2.
溫馨提示
- 1. 本站所有資源如無特殊說明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請下載最新的WinRAR軟件解壓。
- 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請聯(lián)系上傳者。文件的所有權益歸上傳用戶所有。
- 3. 本站RAR壓縮包中若帶圖紙,網(wǎng)頁內容里面會有圖紙預覽,若沒有圖紙預覽就沒有圖紙。
- 4. 未經(jīng)權益所有人同意不得將文件中的內容挪作商業(yè)或盈利用途。
- 5. 人人文庫網(wǎng)僅提供信息存儲空間,僅對用戶上傳內容的表現(xiàn)方式做保護處理,對用戶上傳分享的文檔內容本身不做任何修改或編輯,并不能對任何下載內容負責。
- 6. 下載文件中如有侵權或不適當內容,請與我們聯(lián)系,我們立即糾正。
- 7. 本站不保證下載資源的準確性、安全性和完整性, 同時也不承擔用戶因使用這些下載資源對自己和他人造成任何形式的傷害或損失。
最新文檔
- 中學學生心理輔導制度
- 養(yǎng)老院工作人員培訓考核制度
- 公共交通車輛維修質量控制制度
- 2026年數(shù)學基礎試題集初中代數(shù)應用題
- 2026年大學化學實驗教學知識競賽試題庫
- 2026年生物科技與健康知識題庫
- 2026年工程招投標代理合同(合規(guī)·中標版)
- 2026年東北大米購銷合同
- 護理帶教中的信息技術應用
- 2025年紅河衛(wèi)生職業(yè)學院單招職業(yè)技能考試模擬測試卷帶答案解析
- 2026年及未來5年市場數(shù)據(jù)中國集裝箱物流行業(yè)市場發(fā)展數(shù)據(jù)監(jiān)測及投資戰(zhàn)略規(guī)劃報告
- 中小學人工智能教育三年發(fā)展規(guī)劃(2026-2028)7500字完整方案目標務實真能落地
- 七年級地理下冊(人教版)東半球其他的國家和地區(qū)-歐洲西部自然環(huán)境教學設計
- 口腔現(xiàn)場義診培訓
- 學校中層管理崗位職責及分工明細(2026年版)
- 江蘇省南京市六校聯(lián)合體2026屆高一數(shù)學第一學期期末監(jiān)測試題含解析
- 就業(yè)部門內控制度
- 2026屆江蘇省徐州市侯集高級中學高一上數(shù)學期末復習檢測試題含解析
- 飛行固模課件
- 2026中國電信四川公司校園招聘備考題庫附答案
- 住院患者安全告知
評論
0/150
提交評論