leawin領(lǐng)域S14K. PRI E1 Adapter 2013-0911A說明書用戶手冊(cè)_第1頁
leawin領(lǐng)域S14K. PRI E1 Adapter 2013-0911A說明書用戶手冊(cè)_第2頁
leawin領(lǐng)域S14K. PRI E1 Adapter 2013-0911A說明書用戶手冊(cè)_第3頁
leawin領(lǐng)域S14K. PRI E1 Adapter 2013-0911A說明書用戶手冊(cè)_第4頁
leawin領(lǐng)域S14K. PRI E1 Adapter 2013-0911A說明書用戶手冊(cè)_第5頁
已閱讀5頁,還剩54頁未讀, 繼續(xù)免費(fèi)閱讀

下載本文檔

版權(quán)說明:本文檔由用戶提供并上傳,收益歸屬內(nèi)容提供方,若內(nèi)容存在侵權(quán),請(qǐng)進(jìn)行舉報(bào)或認(rèn)領(lǐng)

文檔簡(jiǎn)介

Panasonic

System

NetworksPBX

SE

teamKX-NS1000

Step

by

Step

GuideE1

Adapter

/

PRI

AdapterKX-NS8188

/

KX-NS8290September

11,

2013When

customers

want

to

use

IP-Phone

mainly

for

extension

and

theywant

to

use

E1

or

more

than

2

PRI

as

trunk,

KX-NS1000

version

2

withtrunk

adapter

is

recommended.Activation

key

for

IP

trunk

is

not

required

to

connect

E1

/

PRI

adapter.Trunk

adapter

cannot

be

connected

withother

PBX

using

SIP.1.

IntroductionModelSpecificationsKX-NS8188XE1

adapter

on

SIP

trunkKX-NS8290CEPRI30

adapter

on

SIP

trunkKX-NS8290XPRI23

adapter

on

SIP

trunkTrunk

AdaptorSIP

Trunk

(30-ch)PRI30SIP

ExtensionPanasonicKX-NS8290PRI30PRI

CardSIPSoftphoneKX-NT

KX-UT

OtherSIP

PhoneKX-NS1000KX-NCS0290IP

Network215

mm

(W)44

mm(H)200

mm

(D)500gIP

Trunk

AK2Before

adding

KX-NS10002.

Stacking

CardAnalogCOKX-TDECO

CardKX-DT

w/DSS

ConsoleSLTEXT

CardMPR

CardAfter

adding

KX-NS1000AnalogCOKX-TDECO

CardOtherSIP

PhoneSIPSoftphoneKX-NTKX-UTSLTEXT

CardSC

CardDirect

Connectionlike

TDE600

to

TDE620IP

NetworkKX-DT

w/DSS

ConsoleKX-NS1000SC

CardKX-NCS0130When

customer

has

Panasonic

PBX

now,

they

can

add

IP

capacity

andbuilt-in

solution

using

KX-NS1000

version

2

with

stacking

card

KX-NS0130

with

keeping

current

PBX.KX-TDA0131/0132

is

installed

instead

of

MPR

card.This

configuration

is

useful

for

new

customeralso

to

increase

SLT

and

so

on.KX-NS0130Stacking

card

for

NS100KX-NS0131Stacking

card

for

NCPKX-NS0132Stacking

card

for

TDA/TDE100

%

FeatureTransparencylike

TDE600and

TDE620Reference33.

Table

ofContents4ChapterExplanation1Overview2Specifications3Concept

of

programming

for

Public

mode4Step

by

step

programming

for

the

trunk

adapter5Step

by

step

programming

for

KX-NS10006Programming

hint

for

Private

mode

(QSIG)7Demonstration

guideChapter

1Overview5Also

useful

to

provide

PRI/E1with

2-ch

Analog

CO

or

4

BRI.PRI30E1Trunk

AdaptorAnalogSIP

Trunk

CO(30-ch)Maximum

256

ch

is

available

for

E1

/

PRI

by

adapter

and

IP

trunk.SIP

Trunk(30-ch)Max.

256ch

can

be

registered

to

SIP

provider

or

the

adapter.PRI30PRI

CardSIP

Trunk(30-ch)PRI30E1Trunk

AdaptorSIPProviderCO

CardSIP

Trunk(xx-ch)11.

Capacity256chPRI30E1Trunk

AdaptorLineNS1000x

1NS1000x

2NS1000x

3NS1000x

4

or

moreTrunk256256

x

2600Legacy256256

x

2600IP

incl

E1/PRI

adapter256256SIP256256H.3234848x2=

966Fractional

service

is

also

available.<Stand

alone>12.

PRI

Adapter

-

Fractional

Service20chKX-NS10001st

KX-NS1000in

Fukuoka20ch30ch10ch20chE1/PRITrunk

AdaptorTrunk

AdaptorTotal

256ch<One-look

network>20chE1/PRITrunk

Adaptor2ndKX-NS1000in

Tokyo16th

KX-NS1000in

Niseko30ch60chE1/PRITrunk

Adaptor

Trunk

Adaptor710chE1/PRI13.

PRI

Adapter

-

QSIGIP

Network(VPN)KX-NS1000Ext1xxExt

2xxExt

4xx192.168.0.101192.168.30.101Ext

3xx192.168.40.101192.168.0.151Trunk

AdaptorISDN

QSIGDN2IP

table

(Dial

to

IP)Dial

2xx

to

51Dial

3xx

to

01Dial

4xx

to

01H.323IP

Trunk

AKP

RI8PRI

adapter

supports

ISDN

QSIG

also

to

connect

with

other

PBX.Activation

key

forIP

trunk

isnot

required

for

PRI

adapter.Trunk

adapter

cannot

be

connected

withother

PBX

using

H.323.KX-TDA/TDE/NCP

orPBX

by

other

makerH.323

is

used

for

thisconfiguration

instead

of

SIP.FeaturesNS8290TDA0290(Reference)QSIGserviceCLIP/CLIRYesYesCNIP/CNIRYesYesCallForwarding(CF)YesYesCall

Transfer

(CT)YesYesCompletion

of

Calls

to

Busy

Subscriber(CCBS)YesYesNetwork

Direct

Station

Selection

(NDSS)YesYesCentralized

Voice

MailYesYesNetwork

ICD

GroupYesYesLineNS1000x

1NS1000x

2NS1000IPincl

E1/PRI

adapter256225566SIP

+

PRI

Adapter

for

Public256256H.323

+

PRI

Adapter

for

QSIG4848x2=

9614.

PRI

QSIG

Capacity

&

SpecificationNTSr1u0n0k

0AdaptorKX-NS8290x

3

KX-NSx0249o0r

morePRI

Card9KX-NS1000Chapter

2Specifications1021.

Hardware

AppearanceNo.Description1System

LED2E1

/

PRI

line

LED3DC

Jack4LAN

Port5LAN

LED

(Link)6LAN

LED

(Transmission

Speed)7E1

/

PRI

line

port8Initialize

button

(Not

slide

switch)Hardware

Appearance

is

as

follows.Front11BackWall

MountainUnpack

the

box

and

check

the

itemsbelow:MainUnitx

1Screw

x

2Washer

x

2KX-NS8188

/

KX-NS8290

supports

PoE.If

PoE

is

not

supported

by

network,

AC

adapter

is

required.KX-A420

for

BrazilKX-A239

for

others*)

These

are

same

model

of

AC

adapter

for

KX-UT

phone.1222.

PoE

(Power

over

Ethernet)KX-NS8188

E1

adapter

supports

following

features.23.

KX-NS8188

E1

AdapterFeaturesNS8188TDA0188(Reference)SignalingDR2YesYesE&M-CNoYesE&M-PNoYesDial

TypeMFC-R2YesYesDTMFYesYesPulseNoYesCaller

Number

Notification

(ANI)YesYesCharge

/

Meter

PulseNoYesDeny

collect

call

for

BrazilYesYesOutgoing

call

auto

disconnectYesYesKX-TDEKX-TDA0188KX-NS8188Trunk

AdaptorE113KX-NS100024.

KX-NS8290

PRI

AdapterFeaturesNS8290NS0290(Reference)ModeCO

(Public)YesYesExtensionNoYesQSIG-master/slave

(Private)YesYesISDNCarrier

Service(Public)CLIP

/

CLIRYesYesCOLP

/

COLRNoYesCNIP

/CNIRYesYesCONP

/

CONRNoYesAdvice

of

chargeYesYesCall

ForwardingNoYesCall

HoldNoYesCall

Transfer

(incl.

ISDN

Centrex)NoYesTree-party

conferenceNoYesMalicious

call

identificationNoYesGeneric

keypad

protocolNoYesCCBSNoYesISDN

-

Virtual

Private

NetworkNoYesE-911

(for

PRI23)YesYesKX-NS8290

PRI

adapter

supports

following

features.“No”

because

theseservices

by

ISDNprovider

arenotpopularand

PBX

can

supportsame

feature

basically.KX-NS8290Trunk

AdaptorKX-NS0290PRI

CardISDNConfbyPBX14ConfbyISDNKX-NS1000Back-up

is

available

automatically

for

SIP

trunk

incl

E1

/

PRIadapter,

KX-NT/UT

IP-phone.SIP

TrunkKX-NS1000

(1st)MasterPRI/E1

or

SIP

ProviderTrunk

AdaptorKX-NS1000(2nd)KX-NTKX-UTTrunk

AdaptorKX-NS1000MasterKX-NS1000Back-up

MasterKX-NTKX-UTAfter

master

PBX

stops

working,SIP

TrunkOne-Look

AKBack-up

MasterOne-Look

AKBack-up

master

PBXworks

as

slave

PBXusually.But

it

works

asmaster

PBX

aftermaster

PBX

stopsworking.KX-NTKX-UTKX-NTKX-UTOne-Look

AKOne-Look

AKPRI/E1

or

SIP

Provider25.

Solution

with

“Back-up

Master”15Chapter

3Concept

of

Programmingfor

Public

Connection1631.

Concept

of

Programming

-

AdapterThe

trunk

adapter

is

PBX

with

E1

/

PRI

trunk

and

SIP

extension.SIP

trunk

of

KX-NS1000

is

registered

to

SIP

extension

of

the

adapter.<Programming

for

the

trunk

adapter>Software

of

the

adapter

is

basically

same

as

KX-NS1000.

Features

exceptE1

/

PRI

and

SIP

extension

are

removed.

Therefore

programming

methodE1

/

PRITrunk

AdaptorSIP

Extension401-430PRIKX-NS100030ch

or

23chKX-NS0290is

very

similar

to

KX-NS1000.-

PRI

configuration

is

same

as

programmingfor

KX-NS1000

PRI

card

(KX-NS0290).E1

configuration

is

same

as

KX-TDE

E1card

(KX-TDA0188).-

SIP

extension

configuration

is

same

asKX-NS1000.But

SIP

extension

is

programmedby

default.401

to

430

for

E1

/

PRI30401

to

423

for

PRI23PRI

CardID

401-430SIP

TrunkKX-TDEKX-TDA018817E1/

ISDN32.

Concept

of

Programming

NS1000<Programming

for

KX-NS1000>The

trunk

adapter

is

basically

SIP

provider

for

KX-NS1000.Following

has

to

be

programmed.IP

address

of

theadapteras

SIP

server

destinationSIP

registration

User

ID

(Password

is

not

required.)Connection

Attribute

:

SIP

Provider

/

Trunk

AdapterE1/

ISDN18E1

/

PRITrunk

AdaptorSIP

Extension401-43030ch

or

23chID

401-430SIP

TrunkKX-NS100040140243033.

Concept

of

Programming

-

Call<Programming

for

KX-NS1000

-

CONT>Programming

of

the

trunk

adapter

is

notrequired

for

DDI

/

DIL

incoming

call

fromE1/PRI

to

SIP

extension.

It

works

like

DIL1:1

without

programming

and

DDInumber

and

caller

ID

are

informed

fromthe

trunk

adapter

to

KX-NS1000.Programming

of

KX-NS1000

is

requiredfor

DDI

/

DIL.Outgoing

call

is

also

programmed

forKX-NS1000

instead

of

the

trunk

adapter.Therefore

administrator

has

to

accessonly

KX-NS1000

to

change

extensionnumber,

DDI

and

so

on

after

dealerinstalled.SIP

ExtensionKX-NS1000E1

/

ISDNSIP

TrunkCH1CH2

CH30Trunk

AdapterE1

/

PRIDDICaller

ID19Chapter

4Step

by

Step

Programmingfor

Trunk

AdapterTrunk

AdaptorKX-NS100020Operation

and

“SYSTEM”

LED

display

is

as

follows.1.

Power

On

(Connect

AC

adapter

or

connect

LAN

with

PoE)(a)

Amber

On

(5

sec)(b)

Amber

rapid

flash

(5

sec)During

(b),

keep

pressing

Initialize

button

for

1s.Off

(2

sec)Amber

On

(30

sec)Amber

slow

flash

(120

sec)Green

slow

flashDisplay

of

(b)

finishes

before

5

sec

after

operation

of

(2).Display

of

(f)

means

success

of

initialization

and

awaiting“Easy

set-up”

of

webmaintenance

console.System

LEDInitialize

Button41.

InitializeTrunk

AdaptorKX-NS100021LED

indication

is

as

follows.42.

LED

IndicationTrunk

AdaptorKX-NS100022Set

IP

address

9

for

example

to

your

PC

likefirst

connection

of

KX-TDE

or

KX-NCP.Trunk

adapter

does

not

have

maintenance

port

withDHCP

server.Sub-net

mask

should

be

Connect

51

by

Firefox.Default

IP

address

of

trunk

adapter

is

51.43.

PC

Connection

-

151by

default9for

exampleTrunk

AdapterKX-NS1000DHCP

Server01by

defaultFor

demo,

NS1000

withDHCP

server

functionis

useful

to

assign

IPaddress

of

PCautomatically.Trunk

AdaptorKX-NS100023In

10

seconds

from

step

in

previous

page,log-in

menu

is

displayed.Input

“INSTALLER”

as

user

and

“1234”

as

password.43.

PC

Connection

-

2Trunk

AdaptorKX-NS10002444.

Easy

setup

-

Language

selection(1)

Select

language.Trunk

AdaptorKX-NS10002544.

Easy

setup

-

1(1)

Select

Suffix

of

KX-NS1000

and

area.No

needto

changeIf

Suffix

is

changed,

system

restartsagain

after

click

[OK].Wait

3

min

and

connect

PC

again.Amber

slow

flash

(30

sec)Amber

On

(10

sec)Amber

rapid

flash

(5

sec)Amber

On

(30

sec)Amber

slow

flash

(120

sec)Green

slow

flashTrunk

AdaptorKX-NS10002644.

Easy

setup

-

2No

need

tochange.Adapter

name

is

only

for

reference.Time

is

used

only

for

error

log.Trunk

AdaptorKX-NS10002744.

Easy

setup

-

3(1)

Input

IP

address

of

trunk

adapter

in

actual

customer’snetwork.

Get

the

IP

address

from

IT

manager.*)

For

demo,

default

is

OK.Trunk

AdaptorKX-NS10002844.

Easy

setup

-

4No

need

tochange.-

Time

is

used

only

for

error

log.Trunk

AdaptorKX-NS10002944.

Easy

setup

-

5Input

password

as

you

hope,

click

[Finish].Wait

for

30

seconds.If

LAN

setting

is

changed,

systemrestarts

again

after

click

[OK].Wait

3

min

and

connect

PC

again.Amber

slow

flash

(30

sec)Amber

On

(10

sec)Amber

rapid

flash

(5

sec)Amber

On

(30

sec)Amber

slow

flash

(120

sec)Green

slow

flashTrunk

AdaptorKX-NS10003045.

Maintenance

Console

-

Top

menuIf

LAN

setting

is

changed,Remove

the

trunk

adapter

from

LANConnect

it

to

actual

customer’s

network.Connect

PC

to

IP

address

of

trunk

adapter

using

Firefox.After

log-in,

following

top

menu

is

displayed.If

LAN

setting

is

not

changed,

following

Top

menu

is

displayed.Trunk

AdaptorKX-NS10003145.

Maintenance

Console

-

1Software

version

can

be

confirmed

as

follows.Trunk

AdaptorKX-NS10003245.

Maintenance

Console

-

2Parameter

for

PRI

can

be

modified

as

follows.(Same

as

“PRI

+

2

SLT”

card)Trunk

AdaptorKX-NS10003345.

Maintenance

Console

-

3IP

address

of

adaptercanbe

changed.(No

need

to

change

usually.)Trunk

AdaptorKX-NS10003445.

Maintenance

Console

-

4Software

can

be

updated

by

one

step.(Not

same

as

KX-NS1000)-

Wait

15

minutes

after

clicking

[Execute].(Same

as

KX-NS1000.)Trunk

AdaptorKX-NS10003545.

Maintenance

Console

-

5E1/

PRI

Card

diagnosis

is

supported.Out

of

service

can

be

assigned.This

is

required

for

software

update

also.Trunk

AdaptorKX-NS100036Chapter

5Step

by

Step

Programmingfor

KX-NS10003751.

KX-NS1000

-

Out

of

ServiceInstall

virtual

SIP

trunk

card.Out

of

service

is

required

for

port

or

card

beforeprogramming

in

following

pages.Trunk

AdaptorKX-NS1000Trunk

Adaptor3852.

KX-NS1000

-

Connection

AttributeTrunk

AdaptorKX-NS1000Trunk

AdaptorChange

connection

attribute

from

“SIP

provider”to

“Trunk

Adapter”

for

each

channels

or

click[Trunk

Adapter]

button

to

change

max.

30

chat

the

same

time.Use

this.No

need

to

program

each

ch.39Max.

16

Adapter*)

If

program

manually

not

using

“trunk

adapter”,

more

than

16

adaptercan

be

programmed.53.

KX-NS1000

-

Trunk

Adapter

button

-

1Input

IP

address

of

trunk

adapter

and

click

[Next].-

Trunk

adapter

name

is

for

reference.Web

maintenance

console

forthe

trunk

adapter

is

opened.For

referenceKX-NS100051

52Trunk

Adaptor Trunk

Adaptor40Select

range

to

connect

the

trunkadapter

instead

of

SIP

provider.Select

IP

address

and

click

[Finish].If

fractional

service

is

used,

set

“20”

forexample.

Otherwise

NS1000

tries

makingcall

using

21ch

to

30ch

of

PRI.KX-NS1000SIPProvider4151

52Trunk

Adaptor Trunk

Adaptor54.

KX-NS1000

-

Trunk

Adapter

button

-

255.

KX-NS1000

-

Registration

toSIP

ServerConnection

attribute

were

programmed

by

previousstep.

Parameters

for

registration

to

SIP

server(E1/PRI

adapter)

were

also

programmed.KX-NS100051

52Trunk

Adaptor Trunk

Adaptor4256.

KX-NS1000

-

CLIP“PBX

CLIP”

has

to

be

selected

as

follows

tosend

CLIP

on

extension

for

outgoing

call.Trunk

AdaptorKX-NS1000Trunk

Adaptor4357.

KX-NS1000

-

In

ServiceSet

In

Service.Other

programming

such

as

ARS,

TRS

isbasically

same

as

PRI

for

KX-TDE/NCP.However

it

is

required

to

program

as

next

2

pagesadditionally

because

I/F

with

trunk

adapter

is

SIP.Trunk

AdaptorE1

/ISDNKX-NS1000When

E1/PRI

line

of

trunk

adapter

is

fault,trunk

adapter

stops

communication

withKX-NS1000.

Therefore

the

SIP

trunk

chof

KX-NS1000

becomes

fault.This

specification

is

useful

not

to

use

theSIP

ch

automatically

for

ARS

and

so

on.4458.

KX-NS1000

-

Dialing

PlanDialing

plan

has

to

be

programmed

for

outgoing

callbecause

I/F

with

trunk

adapter

is

SIP

en-block

dial.Otherwise

extension

caller

has

to

wait

for

10

secondsto

hear

ring

back

tone

after

dial

to

E1/PRI

trunkadapter.Trunk

AdaptorKX-NS1000Trunk

Adaptor4559.

KX-NS1000

-

DDI

ModificationDDI

first

3

digits

has

to

be

removed

because

I/F

with

trunk

adapter

isSIP.

ID

such

as

“401”

+

real

DDI

number

is

informed

as

DDI

numberfrom

E1/PRI

adapter

to

KX-NS1000.Trunk

AdaptorE1

/

ISDNKX-NS1000DDI

5101DDI

4015101DDI

4025101DDI

5101Program

DDI

table.4660.

KX-NS1000

-

DDI

DestinationDDI

destination

programmed

is

also

required.(Same

as

PRI+SLT2

card

in

KX-NS1000

or

PRI

card

through

stackingcard

)47Chapter

6Programming

Hint

forPrivate

Mode

(QSIG)4861.

EasySetup

for

Adapter“Private”

has

to

be

selected

byeasysetup

mode.KX-NS1000Ext

1xxExt

2xx192.168.0.151Trunk

AdaptorISDN

QSIG192.168.0.101H.3234962.

PRI

QSIG

mode

for

AdapterQSIG

(Slave)

is

assigned

automatically

aftereasysetup.KX-NS1000Ext

1xxExt

2xx192.168.0.151Trunk

AdaptorISDN

QSIG192.168.0.101H.323500163.

H.323

programming

for

AdapterH.323

destination

programming

of

adapter

is

also

required.Common

IP

address

is

assigned

for

any

dial.

(Not

each

dial)KX-NS1000Ext

1xxExt

2xx192.168.0.151Trunk

AdaptorISDN

QSIG192.168.0.101H.323IP

address

of

Back-upmaster

PBX5164.

H.323

programming

for

KX-NS1000H.323

destination

programming

of

KX-NS1000

is

required

for

adapteras

well

as

other

PBXs.Sole

d

溫馨提示

  • 1. 本站所有資源如無特殊說明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請(qǐng)下載最新的WinRAR軟件解壓。
  • 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請(qǐng)聯(lián)系上傳者。文件的所有權(quán)益歸上傳用戶所有。
  • 3. 本站RAR壓縮包中若帶圖紙,網(wǎng)頁內(nèi)容里面會(huì)有圖紙預(yù)覽,若沒有圖紙預(yù)覽就沒有圖紙。
  • 4. 未經(jīng)權(quán)益所有人同意不得將文件中的內(nèi)容挪作商業(yè)或盈利用途。
  • 5. 人人文庫網(wǎng)僅提供信息存儲(chǔ)空間,僅對(duì)用戶上傳內(nèi)容的表現(xiàn)方式做保護(hù)處理,對(duì)用戶上傳分享的文檔內(nèi)容本身不做任何修改或編輯,并不能對(duì)任何下載內(nèi)容負(fù)責(zé)。
  • 6. 下載文件中如有侵權(quán)或不適當(dāng)內(nèi)容,請(qǐng)與我們聯(lián)系,我們立即糾正。
  • 7. 本站不保證下載資源的準(zhǔn)確性、安全性和完整性, 同時(shí)也不承擔(dān)用戶因使用這些下載資源對(duì)自己和他人造成任何形式的傷害或損失。

評(píng)論

0/150

提交評(píng)論