懷柔區(qū)老舊小區(qū)抗震加固及綜合整治/r/n工程/r/n臨時用電施工/r/n組織設計/r/n/r/n編/r/n/r/n制/r/n/r/n人:/r/n/r/n/r/n/r/n/r/n/r/n/r/n審/r/n/r/n核/r/n/r/n人:/r/n/r/n/r/n/r/n/r/n/r/n/r/n審/r/n/r/n批/r/n/r/n人:/r/n/r/n/r/n/r/n/r/n/r/n編制日期:/r/n20/r/n1/r/n2/r/n年/r/n9/r/n月/r/n6/r/n日/r/n/r/n/r/n/r/n/r/n編制單位:/r/n/r/n北京/r/n城建十公司/r/n懷柔/r/n項目部/r/n/r/n/r/n/r/n

/r/n臨電施工/r/n組織設計/r/n審批表/r/n工程名稱/r/n懷柔區(qū)老舊小區(qū)抗震加固及綜合整治工程/r/n結構型式/r/n磚混/r/n面/r/n/r/n/r/n/r/n/r/n/r/n/r/n積/r/n106127/r/n平方米/r/n層/r/n/r/n/r/n/r/n/r/n/r/n/r/n/r/n數(shù)/r/n地上/r/n六/r/n層/r/n建設單位/r/n北京/r/n懷柔區(qū)住房和城鄉(xiāng)建設委員會/r/n施工單位/r/n北京城建/r/n十建設工程有限公司/r/n編制部門/r/n北京城建/r/n十/r/n公司/r/n懷柔/r/n項目部/r/n編/r/n/r/n/r/n制/r/n/r/n/r/n人/r/n編制時間/r/n報審時間/r/n審批部門/r/n北京城建十公司技術/r/n質量/r/n部/r/n審批時間/r/n審/r/n/r/n/r/n批/r/n/r/n/r/n人/r/n/r/n/r/n/r/n/r/n審批意見:(填寫討論的主要結論、包括應修改的部分)/r/n臨電/r/n施工組織設計/r/n會簽表/r/n工程名稱/r/n懷柔區(qū)老舊小區(qū)抗震加固及綜合整治工程/r/n結構形式/r/n/r/n磚混/r/n建筑面積/r/n106127/r/n平方米/r/n層/r/n/r/n數(shù)/r/n地上/r/n六/r/n層/r/n建設單位/r/n北京/r/n懷柔區(qū)住房和城鄉(xiāng)建設委員會/r/n施工單位/r/n北京城建/r/n十建設工程有限公司/r/n設計單位/r/n泛華建設集團有限公司/r/n北京國科天創(chuàng)建筑設計院/r/n編制單位/r/n北京/r/n城建十公司懷柔/r/n項目部/r/n編制人/r/n編制時間/r/n20/r/n1/r/n2/r/n年/r/n9/r/n月/r/n6/r/n日/r/n會簽部門/r/n項目經(jīng)理/r/n會簽部門/r/n技術/r/n質量/r/n部/r/n會簽意見:/r/n會簽人:/r/n/r/n年/r/n/r/n月/r/n/r/n日/r/n會簽意見:/r/n會簽人:/r/n/r/n年/r/n/r/n月/r/n/r/n日/r/n會簽部門/r/n安全/r/n生產(chǎn)/r/n部/r/n會簽部門/r/n會簽意見:/r/n會簽人:/r/n/r/n年/r/n/r/n月/r/n/r/n日/r/n會簽意見:/r/n會簽人:/r/n/r/n年/r/n/r/n月/r/n/r/n日/r/n會簽部門/r/n會簽部門/r/n會簽意見:/r/n會簽人:/r/n/r/n年/r/n/r/n月/r/n/r/n日/r/n會簽意見:/r/n會簽人:/r/n/r/n年/r/n/r/n月/r/n/r/n日/r/n會簽部門/r/n會簽部門/r/n會簽意見:/r/n會簽人:/r/n/r/n年/r/n/r/n月/r/n/r/n日/r/n會簽意見:/r/n會簽人:/r/n/r/n年/r/n/r/n月/r/n/r/n日/r/n

/r/n/r/n目/r/n/r/n錄/r/n一、編制依據(jù)/r/n/r/n/r/n二、/r/n現(xiàn)場勘查/r/n及/r/n工程概況/r/n和/r/n工程特點/r/n/r/n三、施工布署/r/n/r/n四、主要施工機具用電設備負荷/r/n/r/n五、負荷計算/r/n/r/n六、現(xiàn)場臨電規(guī)劃及設備選擇/r/n/r/n七、防雷/r/n及/r/n保護接零/r/n(地)措施/r/n/r/n八、/r/n安全技術檔案/r/n/r/n九、/r/n安全用電措施和注意事項/r/n/r/n十、/r/n腳手架防電保護措施/r/n/r/n十/r/n一/r/n、/r/n電氣防火措施/r/n/r/n十/r/n二/r/n、/r/n事故應急預案/r/n/r/n十/r/n三/r/n、/r/n說/r/n/r/n明/r/n/r/n附:臨時用電平面圖/r/n/r/n臨時用電系統(tǒng)圖/r/n

/r/n編制依據(jù)/r/n1./r/n/r/n《施工/r/n現(xiàn)場臨時/r/n用/r/n電/r/n安全技/r/n術規(guī)/r/n范》/r/nJGJ46-2005/r/n2/r/n./r/n施工組織設計/r/n提/r/n供的機械/r/n設備/r/n及/r/n現(xiàn)場/r/n平面/r/n圖/r/n二、/r/n現(xiàn)場勘查/r/n及/r/n工程概況工程特點:/r/n1.現(xiàn)場勘查:/r/n本工程/r/n為老舊小區(qū)改造/r/n,場地狹小,/r/n居民集中/r/n,/r/n小區(qū)道路平坦,為了居民出行方便,/r/n電纜/r/n采用/r/n明敷卡設方式。/r/n2./r/n工程概況:/r/n北京/r/n懷柔區(qū)老舊小區(qū)抗震加固及綜合整治/r/n工程/r/n,位于/r/n北京市/r/n懷柔/r/n區(qū)/r/n青春路9號院、濱湖小區(qū)、興懷大街及迎賓中路/r/n。/r/n建筑面/r/n積為/r/n106127/r/n平方米,/r/n結/r/n構形式/r/n磚混/r/n結構/r/n。/r/n3./r/n工程特點:/r/n該工程/r/n施工時間緊,/r/n施工量大/r/n且施工區(qū)域分散/r/n,/r/n主要/r/n使用/r/n小型電焊機及電/r/n錘等設備/r/n。根據(jù)現(xiàn)場實際情況,目前供電局為青春路9#院/r/n提供/r/n三個配電點/r/n、濱湖小區(qū)/r/n提供/r/n五個配電點/r/n,(額定電流100A)/r/n。/r/n根據(jù)本工程用電設備多,容量/r/n小/r/n,同期使用電氣設備可能性較大等特點,做如下安排:/r/n現(xiàn)場電源/r/n由供電公司從小區(qū)桿上380V外線/r/n配電點/r/n分別/r/n提供,/r/n根據(jù)現(xiàn)場實際情況/r/n總配電箱/r/nZXA/r/n設在/r/n配電點旁邊/r/n,控制現(xiàn)場/r/nFXB/r/n固定配電箱電源。現(xiàn)場內(nèi)臨電設施嚴格按照/r/n規(guī)范/r/n規(guī)定,實行三級配電、兩極以上漏電保護的要求。/r/n三、施工部署:/r/n本工程臨電系統(tǒng)采用三相五線供電方式,/r/nTN/r/n—/r/nS/r/n保護接零系統(tǒng)。/r/n系統(tǒng)配置詳見后面臨電規(guī)劃有關內(nèi)容。整個施工現(xiàn)場的生產(chǎn)、生活臨設;器具、材料堆放位置;用電設備位置及現(xiàn)場環(huán)境,詳見施工用電平面圖。/r/n1/r/n./r/n本方案依照綜合施工機具負荷計劃進行。/r/n施工/r/n階段/r/n按/r/n現(xiàn)場/r/n樓座位置/r/n每隔兩/r/n樓/r/n設一個/r/n固定配電箱/r/n,位置盡量靠近各區(qū)用電負荷中心,/r/n上樓/r/n電纜敷設充分利用/r/n腳手架/r/n垂直敷設,/r/n由于/r/n腳手架為鋼制,所以上樓電纜/r/n和鋼腳手架進行絕緣包扎,并將包扎好的電線與包扎好的鋼腳手架通過絕緣物綁扎牢固,以免晃動摩擦。/r/n現(xiàn)場/r/n根據(jù)施工需要,分步實施本方案內(nèi)容。現(xiàn)場若有變化,按照本公司《現(xiàn)場臨時用電管理辦法》中有關規(guī)定,及時辦理變更及審批手續(xù)。/r/n2/r/n./r/n本工程現(xiàn)場配電系統(tǒng)分為三級,即總配電箱/r/nZXA/r/n、配電箱/r/nFXB/r/n、開關箱/r/nKXC/r/n。/r/n配電點/r/n至/r/n總配電箱/r/nZXA/r/n出線/r/n我/r/n方提供配置,/r/n本設計包括/r/n總配電箱/r/n至固定配電箱及其之間的連接導線,不考慮工地/r/nKXC/r/n開關箱/r/n下口出線/r/n。工地/r/nKXC/r/n開關箱/r/n下口出線/r/n由項目部臨電電工根據(jù)現(xiàn)場情況自行考慮,但要遵循/r/n“/r/n一機/r/n、/r/n一閘/r/n、一漏、一箱/r/n”/r/n的原則,并保證直接分斷設備的最后一級開關為漏電保護開關。/r/n3/r/n./r/n現(xiàn)場臨時用電工作由公司技術/r/n質量/r/n部和公司安全/r/n生產(chǎn)/r/n部共同監(jiān)督實施。按照本公司《現(xiàn)場臨時用電管理辦法》中有關規(guī)定,項目部設置專人進行管理。/r/n4/r/n./r/n現(xiàn)場臨電工程按照本施組施工完畢,項目部自檢合格后,上報公司,由公司技術/r/n質量/r/n部、安全/r/n生產(chǎn)/r/n部共同驗收,合格后方可投入使用。不得擅自更改本施組內(nèi)容。/r/n5/r/n./r/n本施組在該工程項目竣工,臨電設施拆除后自行廢止。/r/n四、主要施工設備/r/n用電設備負荷/r/n序號/r/n名/r/n/r/n稱/r/n型/r/n/r/n號/r/n額/r/n/r/n定/r/n/r/n功/r/n/r/n率/r/n數(shù)量/r/n設備容量/r/n1/r/n電/r/n/r/n焊/r/n/r/n機/r/n3/r/nKVA380V/r/n4/r/n0/r/n12/r/n0/r/nKVA/r/n2/r/n電錘/r/n1/r/nKW/r/n3/r/n0/r/n30/r/nK/r/nW/r/n3/r/n水鉆/r/n2KW/r/n6/r/n12KW/r/n4/r/n電/r/n/r/n開/r/n/r/n水/r/n/r/n器/r/n12KW/r/n1/r/n12/r/nKW/r/n5/r/n空/r/n/r/n調(diào)/r/n2/r/nKW/r/n1/r/n0/r/n2/r/n0/r/nKW/r/n6/r/n照/r/n/r/n明/r/n1/r/n0KW/r/n1/r/n0/r/nKW/r/n五、負荷計算/r/n根據(jù)施工現(xiàn)場各用電設備使用情況/r/n,/r/n采用需要系數(shù)/r/n(Kx)/r/n法/r/n,/r/n將用電設備分組進行計算/r/n,/r/n計算公式如下:/r/nP/r/nj/r/n=Kx×/r/n∑/r/nPe/r/n————/r/n有功功率/r/nQ/r/nj/r/n=P/r/nj/r/n×tg/r/n————/r/n無功功率/r/nS/r/nj/r/n=/r/n————/r/n視在功率/r/n1/r/n、分組負荷計算:/r/n(1)/r/n/r/n電焊機組:/r/n/r/n將焊機負荷由暫載率/r/n60%/r/n換算成/r/n100%/r/n的負荷為/r/nP/r/ne/r/n=S/r/ne/r/n’/r/n××=/r/n3/r/n××0.58=/r/n1/r/n./r/n3/r/nKW/r/n/r/n∑/r/nP/r/ne/r/n=/r/n×/r/n1/r/n./r/n3/r/n×/r/n4/r/n0/r/n=/r/n90/r/nKW/r/n/r/n取/r/nK/r/nx/r/n=0./r/n7/r/n=0./r/n5/r/n/r/n即/r/ntg=/r/n1/r/n./r/n1/r/nP/r/nj/r/n1/r/n=0./r/n7/r/n×/r/n90/r/n=/r/n63/r/nKW/r/nQ/r/nj/r/n1/r/n=/r/n63/r/n×/r/n1/r/n./r/n1/r/n=/r/n69/r/nKVR/r/nS/r/nj/r/n1/r/n==/r/n/r/n=/r/n93/r/nKVA/r/n(/r/n2/r/n)/r/n機械設備組:/r/n/r/nSYMBOL83\f"Symbol"/r/nP/r/ne/r/n=/r/n∑/r/nP/r/ne/r/n’/r/n=/r/n30/r/n+/r/n12/r/n=/r/n42/r/nKW/r/n/r/n取/r/nK/r/nx/r/n=0.7=0.75/r/n即/r/ntg=0.88/r/nP/r/nj/r/n3/r/n=0.7×/r/n42/r/n=/r/n30/r/n/r/nKW/r/nQ/r/nj/r/n3/r/n=/r/n30/r/n×0.88=/r/n27/r/nKVR/r/nS/r/nj/r/n3/r/n==/r/n/r/n=/r/n41/r/nKVA/r/n(/r/n3/r/n)/r/n生活辦公及其它負荷:/r/n/r/nSYMBOL83\f"Symbol"/r/nP/r/ne/r/n=/r/n∑/r/nP/r/ne/r/n’/r/n=/r/n3/r/n0/r/n+/r/n1/r/n2/r/n=/r/n4/r/n2/r/nKW/r/n/r/n取/r/nK/r/nx/r/n=0./r/n9/r/n/r/n/r/n=/r/n1/r/n/r/n即/r/ntg=/r/n0/r/nP/r/nj/r/n6/r/n=0./r/n9/r/n×/r/n4/r/n2/r/n=/r/n38/r/nKW/r/nQ/r/nj/r/n6/r/n=/r/n26/r/n×/r/n0/r/n=/r/n0/r/nKVR/r/nS/r/nj/r/n6/r/n==/r/n/r/n=/r/n38/r/nKVA/r/n/r/n2/r/n、現(xiàn)場總負荷:/r/n/r/n取同期系數(shù)/r/nK/r/np/r/n=0.7/r/n/r/n有功功率:/r/nP/r/nj/r/n=K/r/np/r/n×/r/n=/r/n0.7×(/r/n63/r/n+/r/n30/r/n+/r/n38/r/n)/r/n=0.7×/r/n131/r/n=/r/n92/r/nKW/r/n/r/n無功功率:/r/nQ/r/nj/r/n=K/r/nq/r/n×/r/n=/r/n0.7×(/r/n69/r/n+/r/n27/r/n+/r/n0/r/n)/r/n=0.7×/r/n96/r/n=/r/n6/r/n7/r/nKVR/r/n/r/n整個施工現(xiàn)場的計算容量:/r/nS/r/nj/r/n==/r/n/r/n/r/n=/r/n114/r/nKVA/r/n/r/n/r/nI/r/nj/r/n=/r/nS/r/nj/r/n/(×U)=/r/n114/r/n/0.65=/r/n175/r/n/r/nA/r/n按需用系數(shù)/r/n0.7/r/n算,/r/n濱湖小區(qū)/r/n目前/r/n供電公司/r/n提供/r/n的/r/n八/r/n個配電點/r/n(每個100A)/r/n,/r/n能/r/n滿足設備使用和運行要求。/r/n六、現(xiàn)場臨電規(guī)劃及設備選擇:/r/n1/r/n、/r/n從/r/n每個/r/n100A/r/n(/r/n八/r/n個)/r/n電源/r/n配電點旁邊(桿下)設一級配電箱/r/nZ/r/nX/r/nA/r/n再由/r/nZ/r/nX/r/nA/r/n箱分兩/r/n路到施工現(xiàn)場/r/n設/r/n置的/r/n兩/r/n臺/r/nFXB/r/n(二級)/r/n配電箱/r/n,/r/n配電箱位置及線路布置、走向/r/n,/r/n詳見施工用電平面圖。/r/n2/r/n、現(xiàn)場臨電系統(tǒng)為/r/nTN/r/n—/r/nS/r/n保護接零系統(tǒng)?,F(xiàn)場變壓器工作接地裝置,接地電阻值/r/n≤/r/n4/r/nΩ/r/n;場內(nèi)固定配電箱要設重復接地裝置/r/n,/r/n接地電阻值/r/n≤/r/n10/r/nΩ/r/n。詳細要求見后面有關內(nèi)容。/r/n3/r/n、由總配電箱出線至各固定配電箱全部采用鎧裝電纜,/r/n桿上明/r/n敷設,并做好相應防護措施。/r/n/r/n上樓電纜敷設充分利用腳手架垂直敷設,由于腳手架為鋼制,所以上樓電纜/r/n和鋼腳手架進行絕緣包扎,并將包扎好的電線與包扎好的鋼腳手架通過絕緣物綁扎牢固,以免晃動摩擦。/r/n4/r/n、/r/n場內(nèi)所有配電箱均要進行編號/r/n,/r/n統(tǒng)一進行管理。編號如下:/r/n/r/n總配電箱/r/n————/r/n/r/nZXA/r/n/r/n分配電箱/r/n————/r/n/r/nFXB1/r/n、/r/nFXB2/r/n/r/n……/r/n/r/n開/r/n/r/n關/r/n/r/n箱/r/n————/r/n/r/nKXC1/r/n、/r/nKXC2/r/n/r/n……/r/n5/r/n、負荷計算及設備選擇:/r/n</r/n1/r/n>/r/n第/r/n一/r/n配電支/r/n路:/r/n(/r/n現(xiàn)場/r/n東/r/n北/r/n側/r/nF/r/nX/r/nB/r/n1/r/n箱/r/n)/r/n/r/n主要控制:/r/n東/r/n北側/r/n上樓電源/r/n及/r/n辦公區(qū)/r/n等負荷;/r/n/r/n主要負荷有:/r/n電焊機/r/n2/r/n臺/r/n6/r/nKW/r/n辦公區(qū)負荷/r/n32KW/r/n總負荷計算:/r/n/r/n取/r/nK/r/nx/r/n=0./r/n6/r/n=0.7/r/n即/r/ntg=/r/n0.95/r/nP/r/nj/r/n=0./r/n6/r/n×(/r/n6/r/n+/r/n3/r/n2/r/n)=/r/n23/r/nKW/r/nQ/r/nj/r/n=/r/n23/r/n×/r/n0.95/r/n=/r/n2/r/n2/r/nKVR/r/nS/r/nj/r/n=/r/n/r/n=/r/n3/r/n2/r/nKVA/r/nI/r/nj/r/n=S/r/nj/r/n/(×U)=/r/n3/r/n2/r/n/(×0.38)=/r/n49/r/nA/r/nI/r/nz/r/n=1./r/n3/r/n×I/r/nj/r/n=1./r/n3/r/n×/r/n49/r/n=/r/n64/r/nA/r/n第/r/n一/r/n配電支/r/n路電源由/r/nZXA1/r/n內(nèi)整定電流/r/n63/r/nA/r/n的自動空氣開關控制,進入/r/nF/r/nX/r/nB/r/n1/r/n配電箱電源一次線選用/r/nYJ/r/nL/r/nV/r/n22/r/n—/r/n5/r/n×/r/n1/r/n6/r/n型聚氯乙烯絕緣/r/n鋼帶鎧裝/r/n鋁/r/n芯/r/n電力電纜,由/r/n桿下/r/nZXA1/r/n架空明/r/n敷設至/r/nF/r/nX/r/nB/r/n1/r/n配電箱,并做好防護措施。/r/nF/r/nX/r/nB1/r/n配電箱總開關選用整定電流/r/n63/r/nA/r/n的自動空氣開關/r/n,下口分設四路出線開關,分別為:/r/n1)、整定電流63/r/nA/r/n的漏電保護開關(辦公區(qū)電源箱);/r/n2)、整定電流40/r/nA/r/n的漏電保護開關(電焊機電源箱);/r/n3)、整定電流40/r/nA/r/n的漏電保護開關(電焊機電源箱);/r/n4)、整定電流40/r/nA/r/n的漏電保護開關(/r/n機械設備/r/n電源/r/n箱/r/n);/r/n</r/n2/r/n>/r/n第/r/n二/r/n配電支/r/n路:/r/n(/r/n現(xiàn)場/r/n北/r/n側/r/nF/r/nX/r/nB/r/n2/r/n箱/r/n)/r/n/r/n主要控制:/r/n北/r/n側上樓/r/n等負荷;/r/n/r/n主要負荷有:/r/n電焊機/r/n6/r/n臺/r/n18/r/nKW/r/n機械設備/r/n10臺/r/n20/r/nKW/r/n總負荷計算:/r/n/r/n取/r/nK/r/nx/r/n=0./r/n6/r/n=0.7/r/n即/r/ntg=/r/n0.95/r/nP/r/nj/r/n=0./r/n6/r/n×(/r/n18/r/n+/r/n2/r/n0)=/r/n23/r/nKW/r/nQ/r/nj/r/n=/r/n23/r/n×/r/n0.95/r/n=/r/n22/r/nKVR/r/nS/r/nj/r/n=/r/n/r/n=/r/n32/r/nKVA/r/nI/r/nj/r/n=S/r/nj/r/n/(×U)=/r/n32/r/n/(×0.38)=/r/n49/r/nA/r/nI/r/nz/r/n=1./r/n3/r/n×I/r/nj/r/n=1./r/n3/r/n×/r/n49/r/n=/r/n6/r/n4/r/nA/r/n第/r/n二/r/n配電支/r/n路電源由/r/nZXA1/r/n內(nèi)整定電流/r/n63/r/nA/r/n的自動空氣開關控制,進入/r/nF/r/nX/r/nB/r/n2/r/n配電箱電源一次線選用/r/nYJ/r/nL/r/nV/r/n22/r/n—/r/n5*16/r/n型聚氯乙烯絕緣/r/n鋼帶鎧裝/r/n鋁/r/n芯/r/n電力電纜,由/r/n桿下/r/nZXA1/r/n架空明/r/n敷設至/r/nF/r/nX/r/nB/r/n2/r/n配電箱,并做好防護措施。/r/n/r/nF/r/nX/r/nB2/r/n配電箱/r/n總開關選用/r/n整定電流/r/n63/r/nA/r/n的自動空氣開關/r/n。/r/n下口分設四路出線開關,分別為:/r/n1)、整定電流63/r/nA/r/n的漏電保護開關(/r/n電焊機/r/n電源箱);/r/n2)、整定電流40/r/nA/r/n的漏電保護開關(電焊機電源箱);/r/n3)、整定電流40/r/nA/r/n的漏電保護開關(/r/n機械設備電/r/n源箱);/r/n4)、整定電流40/r/nA/r/n的漏電保護開關(/r/n機械設備/r/n電源/r/n箱/r/n);/r/n注:FXB3、FXB4、FXB5、FXB6、FXB7、FXB8、FXB9、FXB10、FXB12、FXB13、FXB14共11個/r/n二/r/n級配電箱配置與FXB2/r/n二/r/n級配電箱配置/r/n、容量/r/n一致/r/n,不在重復計算/r/n。/r/n</r/n3/r/n>/r/n第/r/n七/r/n配電支/r/n路:(/r/n現(xiàn)場/r/n西南/r/n側/r/nFXB/r/n11/r/n箱/r/n)/r/n/r/n主要控制:/r/n東北側/r/n上樓電源/r/n及辦公區(qū)/r/n等負荷;/r/n/r/n主要負荷有:/r/n電焊機/r/n2/r/n臺/r/n6/r/nKW/r/n辦公區(qū)負荷/r/n10/r/nKW/r/n機械設備/r/n5臺/r/n20KW/r/n總負荷計算:/r/n/r/n取/r/nK/r/nx/r/n=0./r/n6/r/n=0.7/r/n即/r/ntg=/r/n0.95/r/nP/r/nj/r/n=0./r/n6/r/n×(/r/n6/r/n+/r/n10+20/r/n)=/r/n22/r/nKW/r/nQ/r/nj/r/n=/r/n22/r/n×/r/n0.95/r/n=/r/n21/r/nKVR/r/nS/r/nj/r/n=/r/n/r/n=/r/n31/r/nKVA/r/nI/r/nj/r/n=S/r/nj/r/n/(×U)=/r/n31/r/n/(×0.38)=/r/n47/r/nA/r/nI/r/nz/r/n=1./r/n3/r/n×I/r/nj/r/n=1./r/n3/r/n×/r/n4/r/n7/r/n=/r/n6/r/n1/r/nA/r/n第/r/n一配電支/r/n路電源由/r/nZXA/r/n7/r/n內(nèi)整定電流/r/n63/r/nA/r/n的自動空氣開關控制,進入/r/nF/r/nX/r/nB/r/n11/r/n配電箱電源一次線選用/r/nYJLV/r/n22/r/n—/r/n5/r/n×/r/n16/r/n型聚氯乙烯絕緣/r/n鋼帶鎧裝/r/n鋁/r/n芯/r/n電力電纜,由/r/n桿下/r/nZXA/r/n7/r/n架空明/r/n敷設至/r/nF/r/nX/r/nB/r/n11/r/n配電箱,并做好防護措施。/r/nF/r/nX/r/nB/r/n11/r/n配電箱總開關選用整定電流63/r/nA/r/n的自動空氣開關,下口分設四路出線開關,分別為:/r/n1)、整定電流63/r/nA/r/n的漏電保護開關(辦公區(qū)電源箱);/r/n2/r/n)、整定電流63/r/nA/r/n的漏電保護開關(/r/n電焊機/r/n電源箱);/r/n3/r/n)、整定電流40/r/nA/r/n的漏電保護開關(電焊機電源箱);/r/n4/r/n)、整定電流40/r/nA/r/n的漏電保護開關(/r/n機械設備/r/n電源/r/n箱/r/n);/r/n</r/n3/r/n>/r/n施工現(xiàn)場消防系統(tǒng)采用小區(qū)外線消防/r/n管網(wǎng),故此次方案中/r/n無/r/n設計消防/r/n。/r/n七、防雷/r/n及/r/n保護接零/r/n(/r/n地/r/n)/r/n措施/r/n1、/r/n避雷針主要是由主樓防雷引下線、屋頂防雷接閃器和接地裝置。/r/n2、施工現(xiàn)場避雷的安裝對象主要為腳手架。腳手架體頂部四角采用/r/nΦ/r/n10鍍鋅圓鋼與主樓先有的避雷引下線或者屋頂避雷接閃器進行連接,腳手架頂部四角采用接地專用卡進行連接;與主樓避雷引下線或者屋頂避雷接閃器連接時,采用焊接方式并進行防腐處理。/r/n3/r/n、本工程施工用電設計采用三相五線/r/nTN/r/n—/r/nS/r/n供電系統(tǒng),設專用保護零線,現(xiàn)場達到三級配電,兩級以上漏電保護?,F(xiàn)場施工時要本著/r/n“/r/n一機、一閘、一漏、一箱/r/n”/r/n的原則進行細化的臨電配置。/r/n4/r/n、配電箱、開關箱內(nèi)均分設工作零線端子和保護零線端子,工作零與保護零要分開。/r/n5/r/n、配電箱和開關箱的金屬箱體,金屬電器安裝板以及箱內(nèi)電器的不應帶電金屬底座外殼等必須作保護接零?,F(xiàn)場配電箱必須按照公司安全監(jiān)督部要求設圍欄,圍欄也要做保護接零。保護零線應通過接線端子板連接。/r/n6/r/n、與電氣設備相連的保護零線截面,/r/n/r/n應為不小于/r/n/r/n2.5mm/r/n2/r/n/r/n的多股絕緣銅線。手持用電設備的保護零線,應在絕緣良好的多股銅芯橡皮電纜內(nèi),截面不小于/r/n1.5mm/r/n2/r/n,顏色為黃/r/n//r/n綠雙色線。保護零線截面應不小于相線截面的/r/n1/2/r/n。/r/n相線截面小于/r/n16mm/r/n2/r/n時,保護零線截面與相線相同;相線截面大于/r/n16mm/r/n2/r/n小于/r/n35mm/r/n2/r/n時,保護零線截面為/r/n16mm/r/n2/r/n;相線截面大于/r/n35mm/r/n2/r/n時,保護零線截面為相線截面的/r/n1/2/r/n。/r/n10/r/n、保護零線不得經(jīng)過開關、熔斷器,不得做工作零線用,要做到專線專用。正常情況下,保護零線不得有工作電流通過。/r/n1/r/n1/r/n、對產(chǎn)生振動較大的設備,其保護零線連接點不得少于兩處。/r/n八/r/n、安全技術檔案/r/n:/r/n/r/n現(xiàn)場設專職電氣負責人,對現(xiàn)場用電安全及安全技術檔案進行管理。現(xiàn)場施工用電必須建立安全技術檔案。主要內(nèi)容包括/r/n:/r/n1./r/n臨時用電施工組織設計的全部數(shù)據(jù);/r/n2./r/n修改臨時用電施工組織設計的數(shù)據(jù);/r/n3./r/n臨時用電施工技術交底資料;/r/n4./r/n臨時用電檢查驗收記錄;/r/n5./r/n電氣設備的合格證,試驗、檢驗憑證和調(diào)試記錄;/r/n6./r/n臨時用電接地電阻測試記錄;/r/n7./r/n臨時用電定期檢查復查表;/r/n8./r/n臨時用電電工維修記錄;/r/n9./r/n停、送電操作記錄。/r/n10./r/n絕緣電阻測試記錄、檢查復查記錄;/r/n11./r/n安全用電管理制度;/r/n12./r/n電工值班制度及值班名冊;/r/n13./r/n材料合格證、說明書等。/r/n/r/n以上資料依照公司/r/n“/r/n施工用電內(nèi)業(yè)資料檢查評分表/r/n”/r/n要求,及時積累,專人負責收集、整理、歸檔。/r/n/r/n臨時用電工程定期安全檢查和數(shù)據(jù)檢查由安全、技術部門規(guī)定并具體實施。具體獎罰辦法詳見本公司《現(xiàn)場臨時用電管理辦法》。/r/n九/r/n、安全用電措施和注意事項/r/n:/r/n1/r/n、施工現(xiàn)場的臨時用電一定要按電氣施工驗收規(guī)程認真施工,不能因其是臨時用電就敷衍了事。它關系到施工人員的生命安全,要給予足夠的重視。/r/n2/r/n、保證接地裝置的可靠性,正確處理工作零線和保護零線,嚴禁混用。所有需要接地處,必須與保護零線作可靠的電氣連接。保護零線必須采用黃/r/n//r/n綠雙色線,嚴格與相線、工作零線相區(qū)別,杜絕混用?,F(xiàn)場內(nèi)采用接零保護方式,不得有一部分電氣設備接零保護,而另一部分設備接地保護。保護零線不得經(jīng)過開關、熔斷器,正常情況下保護零線不得有電流通過。/r/n3/r/n、所有電氣設備除做保護接零外,還必須實現(xiàn)兩級以上漏電保護,且要保證漏電開關使用靈敏可靠。所有開關箱內(nèi)直接分斷設備電源的開關必須用漏電保護開關。/r/n4/r/n、配電箱或配電線路維修時,應懸掛停電檢修標志牌,嚴格按照操作規(guī)程進行。停、送電必須有專人負責。停、送電操作順序如下/r/n:/r/n<1>/r/n、停電操作順序為/r/n:/r/n/r/n用電設備/r/n/r/n——/r/n/r/n開關箱/r/n/r/n——/r/n/r/n配電箱/r/n/r/n——/r/n箱式變壓器/r/n<2>/r/n、送電操作順序為/r/n:/r/n/r/n/r/n箱式變壓器/r/n/r/n——/r/n/r/n配電箱/r/n/r/n——/r/n/r/n開關箱/r/n/r/n——/r/n/r/n用電設備/r/n5/r/n、配電箱、開關箱內(nèi)所有電器均要有明顯標志,進出線口均在下底面,進出線口加套管。分路敷設,排列整齊不得受力。配電箱、開關箱應作名稱、用途和分路標記并應加鎖,設專人負責。開關箱實行一機一閘制。/r/n6/r/n、施工現(xiàn)場停止作業(yè)/r/n1/r/n小時以上時,應將動力開關箱、配電箱斷電上鎖。/r/n7/r/n、配電箱、開關箱內(nèi)的電器必須可靠完好,不準使用破損的電器。電器設備之間距離應不小于安全用電距離。所有臨時用電的材料,不允許用不合格產(chǎn)品。/r/n8/r/n、帶電導體必須絕緣良好,其上嚴禁搭、掛、壓其它物體。保持與外電的安全距離或采取相應的防護措施。/r/n9/r/n、/r/n配電箱、開關箱周圍,圍護欄周圍按電工規(guī)則,應有工作的空間(前后不于/r/n1米/r/n,左右不于/r/n0.7m/r/n),不得堆放物品。移動式配電箱、開關箱應裝設在固定的支架上,箱體中心線與地面的垂直距離應在/r/n0/r/n.8m/r/n/r/n-1./r/n6/r/nm/r/n之間。固定式配電箱的箱體中心線與地面的垂直距離應在/r/n1./r/n4/r/nm/r/n-1./r/n6/r/nm/r/n1/r/n0/r/n、配電箱和開關箱內(nèi)裝有漏電開關,其額定動作電流/r/n及動作時間/r/n應符合/r/n規(guī)范/r/n規(guī)定/r/n。/r/n1/r/n1/r/n、接地裝置/r/n:接地極采用/r/n一/r/n根/r/n長2.5m/r/n的/r/nΦ/r/n50鍍鋅圓/r/n鋼/r/n。接地體采/r/n用/r/nBV-16mm/r/n2/r/n銅線/r/n與接地極連接,接地體埋深為0.8m。/r/n阻值為重復/r/n接地電阻不得大于/r/n4/r/nΩ/r/n保護/r/n接地電阻不得大于/r/n10/r/nΩ/r/n。/r/n當接地電阻達不到要求時,應增加接地極。/r/n1/r/n2/r/n、行燈電壓不得超過/r/n36V;/r/n隧道、人防工程、高溫、導電灰塵或燈具離地面高度低于/r/n2./r/n5/r/nM/r/n等場所的照明電壓不大于/r/n36V;/r/n潮濕、易觸及帶電體場所照明電壓不大于/r/n24V;/r/n特別潮濕的場所、導電良好的地面、鍋爐或金屬容器內(nèi)照明電壓不大于/r/n1/r/n3/r/n、辦公生活區(qū)臨時用電要求:/r/n⑴/r/n辦公生活區(qū)必須設有專用開關箱,每條回路有單獨開關控制。/r/n⑵/r/n現(xiàn)場臨時辦公室用電時,過墻導線需穿管敷設,室外配線使用風雨線或橡套電纜。使用三孔插座且保護零線到位。/r/n⑶/r/n宿舍內(nèi)燈具高度不能保證達到/r/n2./r/n5/r/n⑷/r/n食堂內(nèi)燈具、開關用防水型,用電設備要有保護零,配備專門開關箱,箱內(nèi)單相與三相回路分開。/r/n⑸/r/n倉庫內(nèi)存有易燃物品時需裝設防爆燈。/r/n1/r/n4/r/n、配電箱與開關箱分開設置,配電箱內(nèi)嚴禁直接接設備。機具電源線進出地面做好防護,進入接線盒也要有保護。電機鐵殼開關都要接保護零。照明回路要單獨設置。/r/n1/r/n5/r/n、建立臨電工程設備、材料安全檢測和材質把關制度,凡是不合格的設備材料一律不得使用。臨電工程設備材料的合格證、說明書、材質證明等要建立技術檔案,妥善保存。導線、漏電保護開關等設備材料器具要進行測試,并記錄測試結果,不符合安全要求堅決不用。/r/n/r/n1/r/n6/r/n、建立安全技術交底制度。向專業(yè)電工及各類用電人員介紹臨時用電施工組織設計和安全用電技術措施的總體意圖、技術內(nèi)容和注意事項,并應在技術交底文字數(shù)據(jù)上履行交底人和被交底人的簽字手續(xù),注明交底日期。/r/n1/r/n7/r/n、建立安全檢測制度。從臨時用電工程完工開始,定期對臨時用電設施進行檢測,主要內(nèi)容有:電纜導線絕緣電阻值、接地電阻值、電氣設備絕緣電阻值、漏電保護器動作參數(shù)等,并作好檢測記錄,以監(jiān)視臨時用電工程是否安全可靠。發(fā)現(xiàn)問題立即檢修。/r/n1/r/n8/r/n、建立電氣維修制度。加強日常和定期維修工作,及時發(fā)現(xiàn)和消除隱患,并建立維修工作記錄,記載維修時間、地點、設備、內(nèi)容、技術措施、處理結果、維修人員、驗收人員等。/r/n19/r/n、建筑工程竣工后,臨時用電設施的拆除,應有統(tǒng)一的組織和指揮,制定周密的拆除計劃。要規(guī)定拆除時間、人員、程序、方法、注意事項和防護措施等。/r/n20/r/n、建立用電安全責任制。對臨時用電工程各部位的操作、監(jiān)護、維修,分片、分塊、分機落實到人,并輔以必要的獎懲。/r/n2/r/n1/r/n、建立安全教育和培訓制度。定期對專業(yè)電工和各類用電人員進行用電安全教育和培訓,經(jīng)考核合格,持證上崗。嚴禁無證上崗。/r/n2/r/n2/r/n、安裝、維修或拆除臨時用電工程,必須由電工完成,嚴禁非電工操作。電工等級應與工程難易程度和技術復雜性相適應。/r/n2/r/n3/r/n、對現(xiàn)場用電設備及電氣裝置、線路要設置防護設施,現(xiàn)場用電設施必須定期進行檢查且要及時維修。電氣設備的設置、安裝、防護、使用、維修、操作及維修人員,必須符合/r/nJGJ46-2005/r/n《施工現(xiàn)場臨時用電安全技術規(guī)范》的要求。/r/n2/r/n4/r/n、建立安全檢查制度和評估制度。按照/r/nJGJ59-99/r/n《建筑施工安全檢查評分標準》定期對現(xiàn)場用電安全情況進行檢查評估。/r/n2/r/n5/r/n、外電防護,應按/r/nJGJ46-2005/r/n《施工現(xiàn)場臨時用電安全技術規(guī)范》的要求,保證和外電線路的安全距離或采取相應的防護措施。/r/n2/r/n6/r/n、高壓電氣設備的操作人員必須具有高壓電工操作本。/r/n2/r/n7/r/n、強化安全用電領導體制,提高電氣技術隊伍素質。/r/n/r/n2/r/n8/r/n、現(xiàn)場人員必須按照《施工現(xiàn)場臨時用電安全技術規(guī)范》的要求,制定各項管理制度,盡職盡責的落實,切實保障施工現(xiàn)場臨時用電的安全。/r/n29/r/n/r/n、/r/n項目部派/r/n陳西金和向愛平/r/n同志為臨電負責人。/r/n3/r/n0/r/n、與所有工程內(nèi)部下屬施工隊及進場分包單位簽定/r/n</r/n安全用電協(xié)議書/r/n>/r/n指定專職電工負責臨電工作。/r/n3/r/n1/r/n、一些警示部位如安全道口、消防栓等,要設置醒目的紅色信號指示燈。/r/n/r/n3/r/n2/r/n、/r/n電焊工應持證上崗,并開具項目專門安全員認可的用火證,用火證上應注明具體工作位置。焊接操作時應穿絕緣鞋和絕緣手套,在潮濕場所和隧洞焊接,應二個同時工作,尤其注意焊接處期產(chǎn)生危險電壓。/r/n十、腳手架防電保護措施/r/n:/r/n腳手架需要穿過或者靠近380V以內(nèi)的/r/n電力線路/r/n時,距離/r/n電力線路/r/n2米以內(nèi)的,在搭設和使用期間,應采取斷電或者拆除措施,如不能不能拆除時,應采取以下防電措施:/r/n1、對/r/n電力線路/r/n和腳手架進行絕緣包扎或在/r/n電力線路/r/n每根線外加/r/n二次/r/n絕緣防護套管,并將做完防電措施的/r/n電力線路/r/n與包扎好的腳手架通過絕緣物綁扎牢固,以免晃動摩擦。/r/n2、腳手架采取接地處理/r/n,如電力線路垂直穿過或靠近腳手架時,應將電力電路周圍至少2米以內(nèi)的腳手架水平連接,并將線路下方的腳手架垂直連接進行接地;如電力線路和腳手架平行靠近時,應將靠近的一斷腳手架在水平/r/n方向進行連接,并在每隔/r/n25/r/n米處進行一次重復接地。/r/n3、/r/n腳手架穿過或靠近電力線路時,有垂直段線路情況的,應搭設防護措施,防止施工時,掉落物損壞電力線路。/r/n4、腳手架內(nèi)有電力線路時,除采用對電力線路進行絕緣包扎措施和穿絕緣防護套管外,還應當/r/n在有電力線路的腳手架處設置防觸電提示;同時施工時,應該注意電力線路的絕緣保護,防止絕緣保護措施被破壞,造成觸電事故。/r/n十/r/n一/r/n、電氣防火措施/r/n:/r/n1/r/n、按設計合理配置、整定各種電氣設備,對電路和設備的超載、短路故障進行可靠的保護。電氣設備損壞后,應及時更換,嚴禁帶病運行。/r/n2/r/n、在電氣裝置和線路周圍,不準堆放易燃、易爆和強腐蝕介質。建立易燃易爆物品和強腐蝕介質管理制度。/r/n3/r/n、加強電氣設備相間和相地間絕緣,防止閃爍。/r/n4/r/n、加強防雷接地保護措施/r/n。/r/n在施工過程中應注意外腳手架的防雷設施的保護,防止被破壞。/r/n5/r/n、加強電氣防火教育,建立電氣防火檢查制度。/r/n6/r/n、建立電氣防火責任制,加強電氣防火重點場所煙火管制,并設置禁止煙火標志。/r/n7/r/n、施工現(xiàn)場/r/n箱式變壓器、總配電/r/n箱、固定配電箱、固定開關箱、電氣設施及電氣材料處,須配備一到兩支干粉滅火器等消防器材,并設專人負責。/r/n8/r/n、強化電氣防火領導制度,建立電氣防火隊伍。/r/n9/r/n、/r/n定期檢查用電設備、線路,保護配電箱及導線清潔,性能可靠、動作靈活。導線絕緣層不殘破、不老化,導線導體不得裸露。/r/n十/r/n二/r/n、/r/n事故應急預案/r/n:/r/n/r/n/r/n在本/r/n工地/r/n臨時用電中,由于電器設備、電纜反復移動,臨時用電的作業(yè)人員多、環(huán)境在不斷變化,工地臨電事故隨時可能發(fā)生。所以本工地編制臨電應急預案具體如下:/r/n1、假設險情:假設工地用電人員由于誤動作發(fā)生低壓臨電事故;電纜被砸斷發(fā)生低壓臨電事故/r/n2、應急準備/r/n1)臨電搶險指揮組即項目部的安全搶險領導組,/r/n/r/n組長:/r/n彭雷/r/n副組長:/r/n張世海/r/n/r/n/r/n李文有/r/n竇金平/r/n組員:/r/n向愛平陳西金/r/n馮友東張廣欽陳正國/r/n2)搶救備用器材:/r/n5m絕緣桿1根/r/n項目部/r/n備用的短路接地極兩處,用/r/nφ/r/n50/r/n×/r/n1500鋼筋打入地下/r/n1.5m/r/n,焊好接電線的螺桿,擰上螺帽M12(不擰緊)。/r/n備兩根/r/n70mm/r/n2鋁芯線各長/r/n50m/r/n。/r/n備一根/r/nφ/r/n20綜繩長/r/n30m/r/n。/r/n備一根/r/nφ/r/n12尼龍繩長/r/n30m/r/n(存項目部)。/r/n急救藥箱2個/r/n手電6個(電工、搶險組、經(jīng)理、副經(jīng)理各1個)。/r/n對講機6部。/r/n符合安全的電工工具由電工自帶。/r/n3)應急聯(lián)系電話/r/n市急救中心:120/r/n4)本應急預案只能模擬演練,要求搶險組、救護組的每一個同志熟知。/r/n3、事故險情內(nèi)部快速通報/r/n如遇臨電事故時,在現(xiàn)場的項目人員要立即用對講機/手機向/r/n項目經(jīng)理匯報險情;在保證自身安全的情況下,現(xiàn)場人員迅速進行搶救臨電者脫離電源。/r/n 項目經(jīng)理立即帶領搶救指揮組成員趕赴出事現(xiàn)場。搶救、救護、防護組成員攜帶著各自的搶險工具,趕赴出事現(xiàn)場。/r/n4.搶救組到達出事地點,在項目經(jīng)理指揮下分頭進行工作。/r/n1)首先搶救組和項目經(jīng)理一起查明險情:確定臨電者的電源是高壓電還是低壓電;臨電電源是否被切斷;是否還有發(fā)生/r/n觸/r/n電的可能和危險物;搶救組提出救護方案;項目經(jīng)理主持商定搶救方案。對低壓臨電事故的處理,采取邊搶救邊匯報的處理方式。對高壓臨電事故采取邊準備邊匯報的處理方式,項目經(jīng)理向公司主管副總經(jīng)理請示匯報批準后組織實施。/r/n2)防護組負責把出事地點附近的作業(yè)人員疏散到安全地帶,并進行警戒不準閑人靠近,對外注意禮貌用語。/r/n3)搶救組電工負責快速使臨電者脫離低壓電氣線路的電源。其方法:/r/n如果事故離電源開關較近,應立即切斷電源開關;如果事故離電源開關太遠,不即立即斷開,救護人員可用干燥的衣服、手套、繩索、木板、木棒等、絕緣桿等絕緣物作為工具,拉開臨電者或挑開電源線使之脫離電源;如果臨電者因抽筋而緊握電線,可用干燥的木柄斧、膠把鉗等工具切斷電線;或用干木板、干膠木板等絕緣物插入臨電者身下,以隔斷電流。/r/n4)脫離電源后的救護。臨電者脫離電源后,應盡量在現(xiàn)場救護,先救后搬;搬運中也要注意臨電者的變化,按傷勢輕重采取不同的救護方法:/r/n如臨電者呈一定的昏迷狀態(tài),還未失去知覺,或臨電時間較長,則應讓他靜臥,保持安靜,再旁看護,并召請醫(yī)生。/r/n如臨電者已失去知覺,但還有呼吸和心臟跳動,應使他舒適地靜臥解開衣服,讓他聞些氨水,或在他身上灑些冷水,摩擦全身,使他發(fā)熱。如天冷還要注意保溫。同時,迅速請醫(yī)生診治如發(fā)現(xiàn)呼吸困難,或逐漸衰弱,并有痙攣現(xiàn)象,則應立即進行人工氧合------即用人工的方法,以起到恢復心臟跳動和人工呼吸互相配合的作用。/r/n如臨電者呼吸、脈搏、心臟均已停止,也不能認為已經(jīng)死亡必須立即進行人工氧合,進行緊急救護。同時迅速請醫(yī)生搶救。/r/n5)人工氧合基本內(nèi)容和步驟/r/n工人氧合是臨電急救行之有效的科學方法。工人氧合包括人工呼吸和心臟擠壓(即心臟按摩兩種方法)。根據(jù)臨電者的具體情況,這兩種方法可單獨應用,也可以配合應用。/r/n(1)口對口(鼻)式人工呼吸法的步驟:使臨

溫馨提示

  • 1. 本站所有資源如無特殊說明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請下載最新的WinRAR軟件解壓。
  • 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請聯(lián)系上傳者。文件的所有權益歸上傳用戶所有。
  • 3. 本站RAR壓縮包中若帶圖紙,網(wǎng)頁內(nèi)容里面會有圖紙預覽,若沒有圖紙預覽就沒有圖紙。
  • 4. 未經(jīng)權益所有人同意不得將文件中的內(nèi)容挪作商業(yè)或盈利用途。
  • 5. 人人文庫網(wǎng)僅提供信息存儲空間,僅對用戶上傳內(nèi)容的表現(xiàn)方式做保護處理,對用戶上傳分享的文檔內(nèi)容本身不做任何修改或編輯,并不能對任何下載內(nèi)容負責。
  • 6. 下載文件中如有侵權或不適當內(nèi)容,請與我們聯(lián)系,我們立即糾正。
  • 7. 本站不保證下載資源的準確性、安全性和完整性, 同時也不承擔用戶因使用這些下載資源對自己和他人造成任何形式的傷害或損失。

最新文檔

評論

0/150

提交評論