版權(quán)說明:本文檔由用戶提供并上傳,收益歸屬內(nèi)容提供方,若內(nèi)容存在侵權(quán),請(qǐng)進(jìn)行舉報(bào)或認(rèn)領(lǐng)
文檔簡(jiǎn)介
RCT INDEX RCT操作單目錄 REV:A0 QSR PAGEYJNP KIC/BUP 1/1
RCT單
頁數(shù)
N°00-VERIFICATIONS-DIAGNOSISOFSTATE
10
N°01-SURVEILLANCEEAS
2
N°02-DELAYEDACTIONS
1
N°301-RESTORATIONOFSI
1
N°302-RESTORATIONOFASG
1
N°303-RESTORATIONOFEAS
1
N°304-RESTORATIONOFPTRTANK
1
N°305-RESTORATIONOFBOOSTING
3
N°306-NXSTACKACTIVITY
1
N°307-SUMPSACTIVITY
1
N°308-CONTAINMENTACTIVITY
1
N°309-EARLYSURVEILLANCEOFCONFINEMENT
1
N°310-ISOLATIONOFSUMPSREINJECTIONTORX
4
N°311-REINJECTIONOFRENPRIMARYTORX
2
N°312-LEAKATRISANDEASCIRCULATION
1
RCT
T00
VERIFICATIONS-DIAGNOSISOFSTATE
REV:A0
QSR
PAGE
1/10
YJNP
KIC/BUP
THEPERFORMANCEOFTHISOPERATIONSHOULDNOTBEINTERRUPTED
START
ECT1inprogress
ECTR1inprogress
AtleastoneSIindicatorlit
ECTR1inprogress ECT1inprogress
AdministrationlockouttypeChasnotbeenimpletmented
Page2 Page7 Page3 Page8
RCT
T00
VERIFICATIONS-DIAGNOSISOFSTATE
REV:A0
QSR
PAGE
2/10
YJNP
KIC/BUP
THEPERFORMANCE
FROMPAGE 1 OFTHISOPERATION
SHOULDNOTBE
SISEQUENCEVERIFICATION INTERRUPTED
SIhasbeenConfirmedbyRPA058TOandRPB058TO
VerifythattheOP1hasnotedthetimeoftheSIintheRMC
TheCIAhasConfirmedbyRPA062TOandRPB062TO
RIS001POand002POIS
RIS077VPand078VPopen RCR100YST
RCV002POor003POandtheassociatedoilliftpumpIS
RCV001POandtheassociatedoilliftpumpIS
VerifyclosingofCIAvalves 25 RIS001MD
VerifymemorizethecontainmentisolationphaseAvalves m3/h
notinconformityontheRMC RIS100YFU
TheventilationofDVHIS
TheventilationoniodinefilterofDVWIS
Theextractionofairatreducedflowrateandtransitionto
25 RIS099MD
3
m/h
iodinefilteroftheventilationofDVKIS AtleastoneRCV
OneRRIandoneSECpumpstaruppertrain pumpIS
DieselgeneratorsetLHPIS RCVpumprackedouttickedunusable
LHAenergized
–Verifytickunusable:
RIS032VPopen
DieselgeneratorsetLHQIS
VerifyLHPISbylocalstarting
LHBenergized
HHSIviaBITbypass RIS033VPopen
HHSIHL
HHSIviaRIS020VP RIS034VPopen
Verifyrack-inthebreakerofthe
thirdRCVpump RIS035VPopen
–VerifytickHHSIunusable
ImplementtheRCTsheetN0301
–VerifyLHQISbylocalstarting (RestorationofSI,forrestoration
ofatleastoneRCVpump)
VerifytheSItypeAactuatorsinsafetyposition
VerifytheSItypeBactuatorsinnormalposition
RIS032VP,033VP,034VPand035VPopen
RIS061VPand062VPopen
VerifytheSImemoriesofdieselgeneratorsetslit
VerifytheSIrecirculationmemorylit
ImplementtheRCTsheetN°301(RestorationofSI,forrestorationofHHSI)
t>tSI+5min
VerifySIsignalhasreset
VerifyCIAsignalhasreset
ECT1inprogress
FIRE
Fireconfirmed
AnapplicablesheetRFI
TheRFIhasbeenimplemented
Confirmimplement:theRFIsheetN°FR00“Fireinitialorientation”
RETURN Page3
REV:A0 QSR PAGE
THEPERFORMANCE
OFTHISOPERATIONSHOULDNOTBEINTERRUPTED
RCT T00 VERIFICATIONS-DIAGNOSISOFSTATE YJNP KIC/BUP 3/10
FROMPAGE1OR 2DIAGNOSISSTATE
CoherenceofRCPpsstatebetweenCCMSandindicationsonKIC
AskOP1to:
RCR100YST
RCPp
IS OS
L.Vessel
S
–ConsiderthoseCCMSfalseindictions
–UsethecorrelativeL.vessel/?TsatonRMC
P.Containmentalways
<1.2bar
A3*10-5
10-8
IRC
RT+20min t
S=THL S=ToV
saturation sub-saturation
140 ?Tsat
Page4
P.containmenthaseverbeen>1.2bar.a
KRT099KA/AAticked
Activityofcont.
KRT022/023MA
mGy/h
20
AtleastoneSGradioactivetickedunusable
AtleastoneSGusableAtleastoneSGradioactive
ThereSGusable
HHSIIS
25
AtleastoneRCVpumpIS
RIS032VPopen
25
RIS099MD
m3/h
KRT099KA/AA
present
OneSGwithpressure10barlowerthantwoothers
RIS001MD
m3/h
Confirmimplement:
ECP2/ECT2
InformOP2
–Cleaningofalarms
–Cleaningofalarms
–Cleaningofalarms
Confirmimplement:
ECP3/ECT3
InformOP2
RIS033VPopen
RIS034VPopenRIS035VPopen
SIblockedunderP11
?Tsat
°C
30
Page6
–Cleaningofalarms
Confirmimplement:
ECP2/ECT2
InformOP2
–Cleaningofalarms
Confirmimplement:
ECP2/ECT2
InformOP2
Confirmimplement:
ECP4/ECT4
InformOP2
RETURN
RCT
T00
VERIFICATIONS-DIAGNOSISOFSTATE
REV:A0
QSR
PAGE
4/10
YJNP
KIC/BUP
FROMPAGE3OR5 THEPERFORMANCE
OFTHISOPERATION
DIAGNOSISSTATE SHOULDNOTBE
INTERRUPTED
L.Vessel
THL
BoC
overheating saturation sub-saturation ?Tsat
AtleastoneRCPpIS
–Cleaningofalarms
Confirmimplement:
ECP4/ECT4
InformOP2 –ThreeRCPpsOS
ContainmentActivity
–VerifytickunusablethenormalspraybyRCP001VPand002VP 20 KRT22/23MA
mGy/h
SIrecirculationmemory
–Coolingat56°C/h
SIrecirculationmemory
signaltrainApresent KIC RPA/B369KS
signaltrainBpresent BUP RPA/B369LA
25 RIS001MD
m3/h AtleastoneSGradioactivetickedunusable
25 RIS099MD
m3/h
AtleastoneSGusable
AtleastoneRCVpumpIS
RIS032VPopen AtleastoneSGradioactive
RIS033VPopen
RIS034VPopen –Cleaningofalarms
RIS035VPopen
–Cleaningofalarms –Cleaningofalarms
PutSIinservicebyRPA
RIS001and002POIS
Confirmimplement: Confirmimplement: Confirmimplement:
ECP3/ECT3 ECP2/ECT2 ECP4/ECT4
058TOandRPB058TO
RCV001POIS InformOP2 InformOP2 InformOP2
RCV002POor003POIS
Page5 –Waitfor2minbeforereadingtheCCMS
RCT
T00
VERIFICATIONS-DIAGNOSISOFSTATE
REV:A0
QSR
PAGE
5/10
YJNP
KIC/BUP
FROMPAGE 4
SISEQUENCEVERIFICATION
THEPERFORMANCEOFTHISOPERATIONSHOULDNOTBEINTERRUPTED
SIhasbeenConfirmedbyRPA058TOandRPB058TO
VerifythattheOP1hasnotedthetimeoftheSIintheRMC
TheCIAhasConfirmedbyRPA062TOandRPB062TO
RIS001POand002POIS
RIS077VPand078VPopen
RCV002POor003POandtheassociatedoilliftpumpIS
RCV001POandtheassociatedoilliftpumpIS
VerifyclosingofCIAvalves 25 RIS001MD
VerifymemorizethecontainmentisolationphaseAvalves m3/h
notinconformityontheRMC
TheventilationofDVHIS
TheventilationoniodinefilterofDVWIS 25 RIS099MD
Theextractionofairatreducedflowrateandtransitionto m3/h
iodinefilteroftheventilationofDVKIS
OneRRIandoneSECpumpstaruppertrain AtleastoneRCV
pumpIS
DieselgeneratorsetLHPIS RCVpumprackedouttickedunusable
LHAenergized –Verifytickunusable:
RIS032VPopen
HHSIviaBITbypass RIS033VPopen
VerifyLHPISbylocalstarting ?HHSIHL
HHSIviaRIS020VP RIS034VPopen
Verifyrack-inthebreakerofthe
DieselgeneratorsetLHQIS thirdRCVpump RIS035VPopenLHBenergized
ImplementtheRCTsheetN0301 –VerifytickHHSIunusable
–VerifyLHQISbylocalstarting (RestorationofSI,forrestoration
ofatleastoneRCVpump)
–ImplementtheRCTsheetN°301
VerifytheSItypeAactuatorsinsafetyposition (RestorationofSI,forrestorationofHHSI)
VerifytheSItypeBactuatorsinnormalposition
RIS032VP,033VP,034VPand035VPopen
RIS061VPand062VPopen
VerifytheSImemoriesofdieselgeneratorsetslit
VerifytheSIrecirculationmemorylit t>tSI+5min
VerifySIsignalhasreset
VerifyCIAsignalhasreset
Page4
RCT
T00
VERIFICATIONS-DIAGNOSISOFSTATE
REV:A0
QSR
PAGE
6/10
YJNP
KIC/BUP
THEPERFORMANCE
FROMPAGE 3 OFTHISOPERATION
CONTROLTHESPRAYOFPZR SHOULDNOTBE
INTERRUPTED
ClosingRCP001VPand CONTROLPZRRELIEFLINES
002VPsuccess
–SetRCP001VPand002VPon AtleastonePRL
MANUat0% openvoluntarily
Reactorcoolantpumps: 159 P.RCP
RCP001POand002POOS(Unit1) bar
OrRCP001POand003POOS(Unit2)
Verifytickdefinitivelyunusable –ProtectionvalvesofPZRrelieflines:
RCP001POand002PO(Unit1) ?RCP520CVonpositionNEU
OrRCP001POand003PO(Unit2) ?RCP521CVonpositionNEU
RCP522CVonpositionNEU
Verifytickunusablethenormal
sprayRCP001VPand002VP 138 P.RCP
–Fallbackmode:NS/RRA bar
Launchfallbacktime:Immediate –Isolationofpressurizerreliefvalves
RCP017VPonpositionCLOSED
VerifynotethefallbackmodeintheRMC ?RCP018VPonpositionCLOSED
RCP019VPonpositionCLOSED
ECT1inprogressRCP020VPseenopen
RCP021VPseenopenRCP022VPseenopen
–Fallbackmode:NS/RRA
–Launchfallbacktime:Immediate
–verifynotethefallbackmodeintheRMC
138 P.RCP
bar
30 ?Tsat
°C
–Cleaningofalarms
Confirmimplement:
ECP2/ECT2 RETURN
InformOP2
RCT
T00
VERIFICATIONS-DIAGNOSISOFSTATE
REV:A0
QSR
PAGE
7/10
YJNP
KIC/BUP
FROMPAGE 1
THEPERFORMANCE
SISEQUENCEVERIFICATION OFTHISOPERATION
SHOULDNOTBE
SIhasbeenConfirmedbyRPA058TOandRPB058TO INTERRUPTED
VerifythattheOP1hasnotedthetimeoftheSIintheRMC
TheCIAhasConfirmedbyRPA062TOandRPB062TO
RIS001POand002POIS
RIS077VPand078VPopen
RCV002POor003POandtheassociatedoilliftpumpIS
RCV001POandtheassociatedoilliftpumpIS
VerifyclosingofCIAvalves
VerifymemorizethecontainmentisolationphaseAvalvesnotinconformityontheRMC
TheventilationofDVHIS
TheventilationoniodinefilterofDVWIS
TheextractionofairatreducedflowrateandtransitiontoiodinefilteroftheventilationofDVKIS
OneRRIandoneSECpumpstaruppertrain
DieselgeneratorsetLHPIS
DieselgeneratorsetLHQIS
LHAenergized –VerifySItypeAinsafetyposition
ExceptRCV222VPand223VP,RIS032VP,033VP,034VPand035VP
VerifyLHPISbylocalstarting –VerifySItypeBinnormalpositionExceptRIS001VP,002VPand003VP
RIS061VPand062VPopen
VerifytheSImemoriesofdieselgeneratorsetslit
VerifytheSIrecirculationmemorylit
LHBenergized
–VerifyLHQISbylocalstarting
t>tSI+5min
VerifySIsignalhasreset
VerifyCIphaseAsignalhasreset
ECTR1inprogress
FIRE
Fireconfirmed
AnapplicablesheetRFI
TheRFIhasbeenimplemented
Confirmimplement:theRFIsheetN°FR00“Fireinitialorientation”
RETURN Page8
RCT
T00
VERIFICATIONS-DIAGNOSISOFSTATE
REV:A0
QSR
PAGE
8/10
YJNP
KIC/BUP
FROMPAGE 7DIAGNOSISSTATE
THEPERFORMANCEOFTHISOPERATIONSHOULDNOTBEINTERRUPTED
CoherenceofRCPpsstatebetweenCCMSandindicationsonKIC
AskOP1to:
ConsiderthoseCCMSfalseindictions
UsethecorrelativeL.vessel/?TsatonRMC IRCA
SIrecirculationmemorysignaltrainApresent 10-8
SIrecirculationmemorysignaltrainBpresent ?Tsat
°C
P.conthaseverbeen>1.2bar.a P.RCP 140
RCPp L.Vessel bar
29
IS OS P.Containment
S=THL S=ToV bar.a
?Tsat
saturation sub-saturation
1.2
AtleastoneRCPpIS
T.RIC
°C
KRT099KAticked
–ThreeRCPpsOS
Page9
98 KRT099KApresent –RCP001VPand002VPclosedonMANU
–Verifytickedunusablenormalsprayby
AtleastoneSG RCP001VPand002VPondrylayup
TheotherSGareusable
ThethereSGareusable
P.RCP P.RCP
bar bar
2.5 2.5
–Cleaningofalarms –Cleaningofalarms
Confirmimplement:
RETURN
Confirmimplement:
ECPR2/ECTR2
ECPR2/ECTR2
InformOP2
InformOP2
RCT
T00
VERIFICATIONS-DIAGNOSISOFSTATE
REV:A0
QSR
PAGE
9/10
YJNP
KIC/BUP
THEPERFORMANCEOFTHISOPERATION
FROMPAGE8OR10 SHOULDNOTBE
INTERRUPTED
DIAGNOSISSTATE
CoherenceofRCPpsstatebetweenCCMSandindicationsonKIC
AskOP1to:
ConsiderthoseCCMSfalseindictions
UsethecorrelativeL.vessel/?TsatonRMC
RPA369KSpresent THL
RPB369KSpresent BoC
L.Vessel
overheating saturation sub-saturation ?Tsat
–ThreeRCPpsOS
–Rack-inofBITisolationsandRISaccus
–PutSIinservicebyRPA
–Rack-inofBITisolationsandRISaccus AtleastoneRCPpIS –CloseRCP001VPand002VP
058TOandRPB058TO RPA369KSpresent –VerifytickunusablethenormalspraybyRCP001VPand002VP
Page10 RPB369KSpresent
?Tsat RPA369KSpresent
saturation sub-saturation –POSthreeRCPps
–CloseRCP001VP
T.RIC and002VP RPB369KSpresent
°C
190
–OpenonePRLvalve –Verifytickunusablethenormal
spraybyRCP001VPand002VP
Verifytick: –Rack-inofBITisolationsandRISaccus –VerifySIsignalhasreset
OpenPRLbeforeRRAISOLATION –VerifyCIphaseAsignalhasreset
RPA369KSpresent
VerifyimplementRCEsheetN°14 –PutSIinserviceby
(IsolationofRRA) RPB369KS RPA058TOandRPB058TO
Verifytickdefinitivelyunusable: –PutSIinserviceby present Confirmimplement:
RRA RPA058TOandRPB058TO ECPR2/ECTR2 Page10
TheRRA/RCVlink InformOP2
–PutSIinserviceby
–Cleaningofalarms RPA058TOandRPB058TO
Confirmimplement: –Waitfor2minbeforereadingtheCCMS
ECP4/ECT4
InformOP2
Page10
RCT
T00
VERIFICATIONS-DIAGNOSISOFSTATE
REV:A0
QSR
PAGE
10/10
YJNP
KIC/BUP
THEPERFORMANCEOFTHISOPERATIONSHOULDNOTBEINTERRUPTED
FROMPAGE 9SISEQUENCEVERIFICATION
SIhasbeenConfirmedbyRPA058TOandRPB058TO
VerifythattheOP1hasnotedthetimeoftheSIintheRMC
TheCIAhasConfirmedbyRPA062TOandRPB062TO
RIS001POand002POIS
RIS077VPand078VPopen
RCV002POor003POandtheassociatedoilliftpumpIS
RCV001POandtheassociatedoilliftpumpIS
VerifyclosingofCIAvalves
VerifymemorizethecontainmentisolationphaseAvalvesnotinconformityontheRMC
TheventilationofDVHIS
TheventilationoniodinefilterofDVWIS
TheextractionofairatreducedflowrateandtransitiontoiodinefilteroftheventilationofDVKIS
OneRRIandoneSECpumpstaruppertrain
DieselgeneratorsetLHPIS
LHAenergized –VerifySItypeAinsafetyposition
ExceptRCV222VPand223VP,RIS032VP,033VP,034VPand035VP
–VerifyLHPISbylocalstarting –VerifySItypeBinnormalpositionExceptRIS001VP,002VPand003VP
–RIS061VPand062VPopen
DieselgeneratorsetLHQIS –VerifytheSImemoriesofdieselgeneratorsetslit
–VerifytheSIrecirculationmemorylit
LHBenergized
–VerifyLHQISbylocalstarting
t>tSI+5min
VerifySIsignalhasreset
VerifyCIphaseAsignalhasreset
Page9
RCT
T01
SURVEILLANCEEAS
REV:A0
QSR
PAGE
1/2
YJNP
KIC/BUP
THEPERFORMANCEOFTHISOPERATIONSHOULDNOTBE
START INTERRUPTED
MONITORINGEASTRAINA
EAS009VBopen
EAS001POIS
EAS007VBopen
EAStrainAtickedunusable
AskOP1toopenEAS007VB EAS001POstoppedand009VB voluntarily
EAS007VBopen
EAS009VBopen
EAS131VBclosed
EAS133VBclosed
EASTrainA
m3/h
800
LNC503KA/AAticked
AskOP1totickEAStrainAunusable
–ImplementRCTsheetN°303(RestorationEAS)forrestorationEAStrainA
Page2
RCT
T01
SURVEILLANCEEAS
REV:A0
QSR
PAGE
2/2
YJNP
KIC/BUP
THEPERFORMANCEOFTHISOPERATIONSHOULDNOTBE
FROMPAGE1 INTERRUPTED
MONITORINGEASTRAINB
EAStrainBtickedunusable
EAS002POIS
EAS010VBopen
AskOP1toopenEAS008VBand010VB
EAS008VBopen
EAS008VBopen
EAS002POstoppedvoluntarily
EAS010VBopen
EAS132VBclosed
EAS134VBclosed
EASTrainB
m3/h
800
LND503KA/AAticked
AskOP1totickEAStrainBunusable
–ImplementRCTsheetN°303(RestorationofEAS)forrestorationEAStrainB
RETURN
RCT
T02
DELAYEDACTIONS
REV:A0
QSR
PAGE
1/1
YJNP
KIC/BUP
THEPERFORMANCE
START OFTHISOPERATION
SHOULDNOTBE
DELAYEDACTIONS INTERRUPTED
RRItrainBcoolingbyPTR(viaEASexchanger)
RRItrainAcoolingbyPTR(viaEASexchanger)
MSIVclosed
MSIVupstreamdrainvalveopen
OnlyoneRCPpIS,ifpossibleRCP001PO
Normalsprayvalve(correspondingtoRCPpOS)closed
Verifytickunusable:
RCPpOS
Correspondingnormalsprayvalve
SAP007KA/AAticked
SAR001KA/AAticked
P.airstabilizedat5.8bar.a
OnlyoneRCPpIS,ifpossibleRCP001PO
Normalsprayvalve(correspondingtoRCPpOS)closed
Verifytickunusable:
RCPpOS
SAP065VAclosed
Correspondingnormalsprayvalve
–CloseSAP065VAlocally
KRT046KA/AAticked
OnlyoneRCPpIS,ifpossibleRCP001PO
Normalsprayvalve(correspondingtoRCPpOS)closed
Verifytickunusable:
RCPpOS
Correspondingnormalsprayvalve
RETURN
RCT
T301
RESTORATIONOFSI
REV:A0
QSR
PAGE
1/1
YJNP
KIC/BUP
START
THEPERFORMANCEOFTHISOPERATIONSHOULDNOTBEINTERRUPTED
RestorationLHSIrequested
RestorationofAtleastoneRCVpumprequested
–VerifythetickingLHSItrainAand(or)Bunusable
–VerifythetickingRCVpumpunusable
RestorationHHSIrequested
RestorationHHSIviaRIS020VPrequested
–VerifythetickingHHSIunusable
RestorationHHSIinHLrequested
–VerifythetickingHHSIviaRIS020VPunusable
RestorationHHSIviatheBITbypassrequested
–VerifythetickingHHSIHLunusable
RestorationSimultaneousinjectionrequested
–VerifythetickingHHSIBITbypassunusable
–Verifythetickingsimultaneousinjectionunusable
AskSSorSTAtotickonthechange-oversupportnote-bookthesheetN°301(RestorationofSI)whileprecisingtherestorationrequested
-AskSS/STAtonotifytheIEPorganizationtorepairandrestoreequipmentswithfault
RETURN
RCT
T302
RESTORATIONOFASG
REV:A0
QSR
PAGE
1/1
YJNP
KIC/BUP
START THEPERFORMANCE
OFTHISOPERATION
TwoMAFPASGIS SHOULDNOTBE
AskSSorSTAtotickonthechange-oversupport INTERRUPTED
note-bookthesheetN°302(RestorationofASG:ASGMotor-drivenpumpschannelAand/orB)
RESTORATIONASG001PO
ASG001POIS
Tickon support
AskSSorSTA LHA001ID=0
thechange-over
note-bookthesheetN°302 LBA002KA/AAticked
(RestorationofASG:ASGTurbine-drivenpumpschannelAand/orB)
RESTORATIONOFASG001POIMPOSSIBLE
AsktoimplementRCEsheetN°302(RestorationofASG)whileprecisingtorestoreASG001PO
AskSSorSTAtotickonthechange-oversupport
note-bookASG001PO“failed”
RESTORATIONASG002PO
ASG002POIS
LBB002KA/AAticked
LHB001ID=0
RESTORATIONOFASG002POIMPOSSIBLE
AsktoimplementRCEsheetN°302(RestorationofASG)whileprecisingtorestoreASG002PO
AskSSorSTAtotickonthechange-oversupport
note-bookASG002PO“failed”
RESTORATIONASG003PO RESTORATIONASG004PO
ASG003POIS ASG004POIS
AsktoimplementRCEsheetN°302 AsktoimplementRCEsheetN°302
(RestorationofASG)whileprecising (RestorationofASG)whileprecising
torestoreASG003PO torestoreASG004PO
RETURN
RCT
T303
RESTORATIONOFEAS
REV:A0
QSR
PAGE
1/1
YJNP
KIC/BUP
THEPERFORMANCEOFTHISOPERATIONSHOULDNOTBE
START INTERRUPTED
RestorationEAStrainArequested
EAS001POIS
EAS002POIS
-AskSS/STAtonotifytheIEPorganizationtorepairandrestoreequipmentswithfault
-AskSS/STAtonotifytheIEPorganizationtorepairandrestoreequipmentswithfault
EAS007VBopen
EAS008VBopen
EAS009VBopen
AsktoimplementRFLLsheetN°LL241(OpenEAS007and009VB)
EAS010VBopen
AsktoimplementRFLLsheetN°LL242(OpenEAS008and010VB)
EAS131VBclosed
EAS132VBclosed
EAS133VBclosed
EAS134VBclosed
AsktoimplementRFLLsheetN°LL109(CloseEAS131and133VB)
AsktoimplementRFLLsheetN°LL078(CloseEAS132and134VB)
AskSS/STAtotickonthechange-oversupportnote-book AskSS/STAtotickonthechange-oversupportnote-bookthesheetRCTN°T303(RestorationofEAS) thesheetRCTN°T303(RestorationofEAS)
-AskSS/STAtonotifytheIEPorganizationtorepair -AskSS/STAtonotifytheIEPorganizationtorepairandrestoreequipmentswithfault andrestoreequipmentswithfault
RETURN RETURN
RCT
T304
RESTORATIONOFPTRTANK
REV:A0
QSR
PAGE
1/1
YJNP
KIC/BUP
THEPERFORMANCEOFTHISOPERATIONSHOULDNOTBEINTERRUPTED
START
RestorationPTRtankrequested
AskSSorSTAtotickonthechange-oversupportnote-bookthesheetN°304(RestorationPTRtank)
-AskSS/STAtonotifytheIEPorganizationtorepairandrestoreequipmentswithfault
RETURN
RCT
T305
RESTORATIONOFBOOSTING
REV:A0
QSR
PAGE
1/3
YJNP
KIC/BUP
THEPERFORMANCEOFTHISOPERATIONSHOULDNOTBEINTERRUPTED
START
RIS001POIS
RIS077VPopen
ReportofRIS077VPopen
RIS002POIS
RIS078VPopen
ReportofRIS078VPopen
REABoronflowrate
6 REA059MD
m3/h
AsktoimplementRCRsheetN°305 REABoronflowrate
(Restorationboosting) 6 REA060MD
m3/h
AsktoimplementRCRsheetN°305(Restorationboosting)
Page3 Page2
RETURN
RCT
T305
RESTORATIONOFBOOSTING
REV:A0
QSR
PAGE
2/3
YJNP
KIC/BUP
FROMPAGE 1
THEPERFORMANCE
RESTORATIONRISBOOSTING OFTHISOPERATION
SHOULDNOTBE
AskSS/STAtotickonthechange-oversupportnote-book INTERRUPTED
thesheetRCTN°T305(Restorationofboosting)
RIS001POISRIS002POIS
PutRIS001POand002POISlocally
RIS077VPopenRIS078VPopen
OpenRIS077VPand078VPlocally
L.PTR001BA
m5.9
1.1
RIS012VPopen
Verifytickingunusable:
Thedirectboration
Theemergencyboration
HHSI
RFLLsheetN°061hasbeen
RIS013VPopen
HHSIBITbypass
HHSIviaRIS020VP
HHSItohotleg
RCV033VPopenRCV034VPopen
implemented
–VerifyuntickRCVpumpunusable
–PutoneRCVpumpIS –PutRCVpumpsOS
–Line-upRCVchargingsuctionfromPTR
VerifytickthosethreeRCVpumpsunusable
RCV033VPopenRCV034VPopen
Verifytickingunusable:
RCVcharging –CloseRIS020VP,021VP,
Normalboration 023VP,032VPand033VP
RCPpinj.
Auxiliaryspray –Verifytickingunusable:
HHSI
HHSItohotleg
HHSIviaRIS020VP
AskSS/STAtotickonthechange-oversupportnote-bookthesheetRCTN°T305(Restorationofboosting)"failed"
RETURN
RCT
T305
RESTORATIONOFBOOSTING
REV:A0
QSR
PAGE
3/3
YJNP
KIC/BUP
THEPERFORMANCEOFTHISOPERATION
FROMPAGE1 SHOULDNOTBE
INTERRUPTED
UNTICKUNUSABLEFUNCTIONS
L.PTR001BA
m5.9
1.1
–Verifyunticking:
Verifyunticking: ?HHSI
HHSI
HHSIviahotlegs
HHSIviaBITbypass ?HHSIviaRIS020VP
HHSIviahotlegs ?ThreeRCVpumps
HHSIviaRIS020VP
Normalboration
Directboration
Emergencyboration
RCVcharging AskSSorSTAtotickonthechange-oversupport
RCPpinj. note-booksheet305(Restorationofboosting)
Auxiliaryspray “successful”
AskSSorSTAtotickonthechange-oversupportnote-booksheet305(Restorationofboosting)“successful”
–VerifyuntickingrequiredRestorationofboosting
RETURN
RCT
T306
NXSTACKACTIVITY
REV:A0
QSR
PAGE
1/1
YJNP
KIC/BUP
THEPERFORMANCEOFTHISOPERATIONSHOULDNOTBEINTERRUPTED
START
INITIATETHEI.E.P.
RequesttheSStoconfirmemergencyclassificationandnotifytheSTA
NXSTACKACTIVITY
AskSSorSTAtotickonthechange-oversupportnote-bookthesheetN°306(NXstackactivity)
AsktoimplementRCEsheetN°306(StackactivityofNX)
TRANSITIONOFVENTILATIONSTOIODINEFILTER
TransitionofventilationsDVN,DVK,DVWtoiodinefilter
DETECTIONOFLOCALCONTAMINATED
DeterminationthecontaminatedzonewiththeaidofthemonitoringchannelKRT036MA
RETURN
RCT
T307
SUMPSACTIVITY
REV:A0
QSR
PAGE
1/1
YJNP
KIC/BUP
START THEPERFORMANCE
OFTHISOPERATION
SHOULDNOTBE
activity)
ReportofRFLLsheetN°LL307(sump INTERRUPTED
–InformSS/STA
9KRT501or502MA>200mGy/h
Or
KRT051,052,053,054or055MA>100mGy/h
INITIATETHEI.E.P.
CONFIRMATIONDIAGNOSIS
KRT048AApresent
RETURN
RequesttheSStoconfirmemergencyclassificationandnotifytheSTA
SUMPSACTIVITY
MemorizetheKRTchannel>200mGy/hbelow
9KRT501MAsumpfloordrainsofNXRPE001PS9KRT502MAsumpresidualdrainofNXRPE002PS
MemorizetheKRTchannel>100mGy/hbelow
KRT051MAsumpfloordrainsEASRPE008PSKRT052MAsumpfloordrainsRIS/LHSIRPE009PSKRT053MAsumpfloordrainsofKXRPE012PSKRT054MAsumpfloordrainsofKXRPE013PSKRT055MAsumpfloordrainsofKXRPE014PS
AskSSorSTAtotickonthechange-oversupportNOTE-BookthesheetN°307(Sumpactivity)Andprecisetohimthesump(s)havinganactivityhigherthan200mGy/h(9KRT501/502MA)
Or
havinganactivityhigherthan100mGy/h(KRT051/052/053/054/055MA)
AsktoimplementRCRsheetN°307
(Sumpactivity)andprecisetohimthesump(s)havinganactivityhigherthan200mGy/h(9KRT501/502MA)
Or
havinganactivityhigherthan100mGy/h(KRT051/052/053/054/055MA)
–Transitiontoreinjectionofsumpuponexceedingtheactivity>200mGy/h(9KRT501/502MA)
Or
exceedingtheactivity>100mGy/h(KRT051/052/053/054/055MA)
toRX,ThereinjectionphaseofsumpwillbefollowedupbytheSS/STAviahissurveillancesystem
RETURN
AsktoimplementRFLLsheetN°LL307(Sumpactivity)
RETURN
9KRT512AApresent
RCT
T308
CONTAINMENTACTIVITY
REV:A0
QSR
PAGE
1/1
YJNP
KIC/BUP
THEPERFORMANCE
START OFTHISOPERATION
SHOULDNOTBE
INITIATETHEI.E.P. INTERRUPTED
RequesttheSStoconfirmemergencyclassificationandnotifytheSTA
CONTAINMENTACTIVITY
AskSSorSTAtotickonthechange-oversupportnote-bookthesheetN°308(Containmentactivity)
AsktoimplementRCRsheetN°308(Containmentactivity)
TRANSITIONOFVENTILATIONSTOIODINEFILTER
–TransitionofventilationsDVN,DVK,DVWtoiodinefilter
DETECTIONOFLOCALCONTAMINATED
ClosethecontainmentisolationvalvesphaseAandB,excepttheRPEvalvesreinjectingtoRXifasumpisinreinjection
THESEVALVESSHOULDNOTBERE-OPENEDWITHOUTADVICEOFTHENATIONALEMERGENCYRESPONSETEAM.
VerifythatOP1hasnotedtheisolationvalvesCIAandCIB,notinconformity,intheRMC
informSS/STA
UNUSABLFUNCTIONS
Verifytickingdefinitivelyunusableof:
RENprimary
Excessletdown
RCVletdown
RRA/RCVlink
REN/APG
APG
RETURN
RCT
T309
EARLYSURVEILLANCEOFCONFINEMENT
REV:A0
QSR
PAGE
1/1
YJNP
KIC/BUP
START
THEPERFORMANCEOFTHISOPERATIONSHOULDNOTBE
INITIATETHEI.E.P. INTERRUPTED
RequesttheSStoconfirmemergencyclassificationandnotifytheSTA
EARLYSURVEILLANCEOFCONTAINMENT
AskSSorSTAtotickonthechange-oversupportnote-bookthesheetN°309(Earlysurveillanceoftheconfinement)
AsktoimplementRCRsheetN°R309(Earlysurveillanceofconfinement)
TRANSITIONOFVENTILATIONSTOIODINEFILTER
CONTAINMENTCONFINEMENT –TransitionofventilationsDVN,DVK,DVWtoiodinefilter
–ClosethecontainmentisolationvalvesphaseAandB,excepttheRPEvalvesreinjectingtoRXifasumpisinreinjection
THESEVALVESSHOULDNOTBERE-OPENEDWITHOUT REN/APGSURVEILLANCE
ADVICEOFTHENATIONALEMERGENCYRESPONSETEAM.
–VerifythatOP1hasnotedtheisolationvalvesCIAand AtleastoneSGmeasureactivity
CIB,notinconformity,intheRMC REN/APG>highlimitofmeasurement
informSS/STA
UNUSABLFUNCTIONS 5000
2000
ContainmentActivity
mGy/h KRT022/023MA
Verifytickingdefinitelyunusableof: 500 TimescinceRT
RCVletdown 200 –PutAPGOS
RRA/RCVlink 6H 5D 1M
Excessletdown –PutREN/APGOS
–Verifytickingdefinitivelyunusableof:
-VerifytheimplementationofRCEsheetN°E309 ?APG
(Earlysurveillanceofcontainmentconfinement) ?REN/APG
informSS/STA
RETURN
RCT
T310
ISOLATIONOFSUMPSREINJECTIONTORX
REV:A0
QSR
PAGE
1/4
YJNP
KIC/BUP
THEPERFORMANCE
START
OFTHISOPERATIONSHOULDNOTBEINTERRUPTED
AsktoimplementRCRsheetN°310(Isolationof
sumpsreinjectiontoRX)
9RPE001PS(FloordrainsofNX)onreinjectionintheRX
ISOLATIONREINJECTIONSUMP9RPE001
溫馨提示
- 1. 本站所有資源如無特殊說明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請(qǐng)下載最新的WinRAR軟件解壓。
- 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請(qǐng)聯(lián)系上傳者。文件的所有權(quán)益歸上傳用戶所有。
- 3. 本站RAR壓縮包中若帶圖紙,網(wǎng)頁內(nèi)容里面會(huì)有圖紙預(yù)覽,若沒有圖紙預(yù)覽就沒有圖紙。
- 4. 未經(jīng)權(quán)益所有人同意不得將文件中的內(nèi)容挪作商業(yè)或盈利用途。
- 5. 人人文庫(kù)網(wǎng)僅提供信息存儲(chǔ)空間,僅對(duì)用戶上傳內(nèi)容的表現(xiàn)方式做保護(hù)處理,對(duì)用戶上傳分享的文檔內(nèi)容本身不做任何修改或編輯,并不能對(duì)任何下載內(nèi)容負(fù)責(zé)。
- 6. 下載文件中如有侵權(quán)或不適當(dāng)內(nèi)容,請(qǐng)與我們聯(lián)系,我們立即糾正。
- 7. 本站不保證下載資源的準(zhǔn)確性、安全性和完整性, 同時(shí)也不承擔(dān)用戶因使用這些下載資源對(duì)自己和他人造成任何形式的傷害或損失。
最新文檔
- 2025年江山市交投人力資源有限公司招聘市場(chǎng)營(yíng)銷專員備考題庫(kù)帶答案詳解
- 2025年湖南蓉園集團(tuán)有限公司公開招聘?jìng)淇碱}庫(kù)及一套參考答案詳解
- 2025年河南省地質(zhì)局所屬事業(yè)單位招聘40人備考題庫(kù)及參考答案詳解1套
- 2025年共享單車區(qū)域差異化管理報(bào)告
- 2025河北廊坊大廠回族自治縣殯儀館招聘2人考試重點(diǎn)題庫(kù)及答案解析
- 2025年上海市同濟(jì)口腔醫(yī)院(同濟(jì)大學(xué)附屬口腔醫(yī)院)實(shí)驗(yàn)技術(shù)員招聘?jìng)淇碱}庫(kù)及完整答案詳解一套
- 2026年常州市衛(wèi)生健康委員會(huì)直屬事業(yè)單位公開招聘高層次、緊缺專業(yè)人才備考題庫(kù)及答案詳解參考
- 2025云南臨滄市臨翔區(qū)搬遷安置辦公室公益性崗位招聘1人筆試重點(diǎn)題庫(kù)及答案解析
- 反重力醫(yī)療設(shè)備協(xié)議
- 2025廣東廣州市勞動(dòng)人事爭(zhēng)議仲裁委員會(huì)招聘兼職仲裁員考試核心題庫(kù)及答案解析
- 產(chǎn)品質(zhì)量檢驗(yàn)標(biāo)準(zhǔn)化操作規(guī)程及模板
- 2025年江蘇省《保安員資格證考試》考試題庫(kù)含答案
- 陰陽五行與人體課件
- 發(fā)展心理學(xué)-終結(jié)性考核-國(guó)開(GS)-參考資料
- 2025年秋季學(xué)期國(guó)家開放大學(xué)《憲法學(xué)》形考任務(wù)1-4答案
- 員工喝酒合同協(xié)議書
- 2025陜西三秦環(huán)??萍脊煞萦邢薰窘?jīng)理層成員市場(chǎng)化選聘工作5人考試筆試參考題庫(kù)附答案解析
- 2025年采購(gòu)人員個(gè)人年終總結(jié)6篇
- 白蛋白肽的課件
- 2026民航華北空管局招聘44人考試筆試參考題庫(kù)附答案解析
- 2025-2026學(xué)年人教版(新教材)小學(xué)數(shù)學(xué)三年級(jí)上冊(cè)期末考試模擬試卷及答案(三套)
評(píng)論
0/150
提交評(píng)論