PAGE1JGJGJGJGJGJ中華人民共和國行業(yè)標(biāo)準(zhǔn)PJGJ113-20建筑玻璃應(yīng)用技術(shù)規(guī)程Technicalspecificationforapplicationofarchitecturalglass(征求意見稿)20--發(fā)布20--實(shí)施中華人民共和國住房和城鄉(xiāng)建設(shè)部發(fā)布中華人民共和國行業(yè)標(biāo)準(zhǔn)建筑玻璃應(yīng)用技術(shù)規(guī)程TechnicalspecificationforapplicationofarchitecturalglassJGJ113-20批準(zhǔn)部門:中華人民共和國住房和城鄉(xiāng)建設(shè)部施行日期:20年月日中國建筑工業(yè)出版社20北京PAGE1PAGE50前言根據(jù)住房和城鄉(xiāng)建設(shè)部《關(guān)于印發(fā)2014年工程建設(shè)標(biāo)準(zhǔn)規(guī)范制訂修訂計劃的通知》(建標(biāo)[2013]169號文)的要求,規(guī)程編制組經(jīng)廣泛調(diào)查研究,認(rèn)真總結(jié)實(shí)踐經(jīng)驗(yàn),參考有關(guān)國際標(biāo)準(zhǔn)和國外先進(jìn)標(biāo)準(zhǔn),并在廣泛征求意見基礎(chǔ)上,修訂了本規(guī)程。本規(guī)程主要技術(shù)內(nèi)容是:1.總則;2.術(shù)語;3.基本規(guī)定;4.材料;5.建筑玻璃抗風(fēng)壓設(shè)計;6.建筑玻璃防熱炸裂設(shè)計;7.建筑玻璃防人體沖擊規(guī)定;8.百頁窗玻璃和屋面玻璃設(shè)計;9.地板玻璃設(shè)計;10.水下用玻璃設(shè)計;11.U型玻璃設(shè)計與施工;12.安裝。本規(guī)程修訂主要技術(shù)內(nèi)容是:本規(guī)程中以黑體字標(biāo)志的條文為強(qiáng)制性條文,必須嚴(yán)格執(zhí)行。本規(guī)程由住房和城鄉(xiāng)建設(shè)部負(fù)責(zé)管理和對強(qiáng)制性條文的解釋,由中國建筑材料科學(xué)研究總院負(fù)責(zé)具體技術(shù)內(nèi)容的解釋。執(zhí)行過程中如有意見或建議,請寄送中國建筑材料科學(xué)研究總院(地址:北京市朝陽區(qū)管莊東里一號;郵政編碼:100024)。本規(guī)程主編單位:本規(guī)程參編單位:本規(guī)程主要起草人員:目次1總則2術(shù)語3基本規(guī)定3.1荷載及其效應(yīng)3.2設(shè)計準(zhǔn)則4材料4.1玻璃4.2玻璃安裝材料5建筑玻璃抗風(fēng)壓設(shè)計5.1風(fēng)荷載計算5.2抗風(fēng)壓設(shè)計6建筑玻璃防熱炸裂設(shè)計與措施6.1防熱炸裂設(shè)計6.2防熱炸裂措施7建筑玻璃防人體沖擊規(guī)定7.1一般規(guī)定7.2玻璃的選擇7.3保護(hù)措施8百葉窗玻璃和屋面玻璃設(shè)計8.1百葉窗玻璃8.2屋面玻璃9地板玻璃設(shè)計9.1一般規(guī)定9.2框支承地板玻璃設(shè)計計算9.3四點(diǎn)支承地板玻璃設(shè)計計算10水下用玻璃設(shè)計10.1水下用玻璃性能要求10.2水下用玻璃設(shè)計計算11U形玻璃設(shè)計與施工11.1一般規(guī)定11.2U型玻璃設(shè)計與計算11.3安裝及配套材料12安裝12.1安裝尺寸要求12.2玻璃安裝材料的使用12.3玻璃抗側(cè)移的安裝要求附錄A玻璃傳熱系數(shù)的計算方法附錄B建筑玻璃結(jié)露點(diǎn)計算方法附錄C玻璃抗風(fēng)壓設(shè)計計算參數(shù)附錄D玻璃板中心溫度和邊框溫度的計算方法本規(guī)程用詞說明引用標(biāo)準(zhǔn)名錄條文說明

Contents1GeneralProvisions2Terms3BasicRequirement3.1Loads3.2DesignCriteria4Materials4.1Glass4.2OtherGlazingMaterials5DesignforWindLoadingonBuildingGlass5.1WindPressure5.2DesignAgainstWindPressure6DesignforThermalStressonBuildingGlass6.1CalculationofThermalStress6.2MeasureagainstGlassThermalStressCracking7CriteriaforHumanImpactSafety7.1GeneralRequirement7.2GlassChoice7.3SafetyMeasure8DesignforLouverBladeandRoofGlass8.1LouverBlade8.2RoofGlass9DesignforFloorGlass9.1GeneralRequirement9.2RectanglesofGlassSupportedalongAllFourEdges9.3RectanglesofGlassSupportedFourPoints10DesignforUnderwaterGlass10.1CriteriaforUnderwaterGlass10.2CalculationofUnderwaterGlass11.DesignandSettingofUGlass11.1GeneralRequirement11.2Design11.3InstallationandMaterials12Installation12.1SettingDemensions12.2DirectionofGlazingMaterials12.3MeasureforGlassFreeinFrameAppendixACalculationofUValueofGlassAPPENDIXBCalculationofDewPointonGlassAPPENDIXCCalculationofParametersforWindLoadAPPENDIXDCalculationofTconCenterofGlassandTExplanationofWordinginthisSpecificationNormativeStandardsExplanationoftheSpeccification1總則1.0.1為使建筑玻璃在建筑工程中的1.0.21.0.3建筑玻璃的

2術(shù)語2.0.1建筑玻璃architecturalglass應(yīng)用于建筑物上的玻璃的統(tǒng)稱。2.0.2荷載垂直玻璃板面,玻璃中部的斷裂強(qiáng)度。2.0.3荷載垂直玻璃板面,玻璃邊緣的斷裂強(qiáng)度。2.0.4荷載垂直玻璃斷面,玻璃端面的抗拉強(qiáng)度。2.0.5平板玻璃、鍍膜玻璃、著色玻璃、半鋼化玻璃和鋼化玻璃等的統(tǒng)稱。2.0.6有框玻璃被具有足夠剛度的支承部件連續(xù)地包住所有邊的玻璃。2.0.7玻璃板自由邊沒有被具有足夠剛度支承部件包住的玻璃邊。2.0.8飾面玻璃室內(nèi)固定在裝飾基層上的建筑裝飾玻璃。2.0.9屋面玻璃roofglass安裝在建筑物屋頂,且與水平面夾角小于75°的玻璃。2.0.10斜面玻璃安裝在建筑物立面,與水平面夾角小于90°且大于75°的玻璃。2.0.11地板玻璃floorandstairwayglazing作為地面使用的玻璃,包括玻璃地板、玻璃通道和玻璃樓梯踏板用玻璃。2.0.12U型玻璃墻由U型玻璃構(gòu)成的墻體。2.0.13前部余隙frontc1earance玻璃外側(cè)表面與壓條或凹槽前端豎直面之間的距離。2.0.14后部余隙backc1earance玻璃內(nèi)側(cè)表面與凹槽后端豎直面之間的距離。2.0.15邊緣間隙edgec1earance玻璃邊緣與凹槽底面之間的距離。2.0.16嵌入深度edgecover玻璃邊緣到可見線之間的距離。2.0.17暖邊間隔條采用低傳導(dǎo)材料制作而成,用于均勻支撐周邊并分隔形成干燥氣體空間層的間隔條,其綜合熱導(dǎo)系數(shù)W/K。3基本規(guī)定3.1荷載及其效應(yīng)3.13.1.2γ0S≤R(3.1.2)式中:γ0—結(jié)構(gòu)重要性系數(shù),取值不應(yīng)小于1.0;S—荷載效應(yīng)基本組合設(shè)計值;R—玻璃抗力設(shè)計值。3.1.3玻璃板在荷載按標(biāo)準(zhǔn)組合作用下產(chǎn)生的df≤[d](3.1.3)式中:df—玻璃板在荷載按標(biāo)準(zhǔn)組合作用下產(chǎn)生的最大撓度值;[d]——玻璃板撓度限值。3.2設(shè)計準(zhǔn)則3.2.13.2.2用于建筑外圍護(hù)結(jié)構(gòu)上的建筑玻璃應(yīng)進(jìn)行玻璃熱工性能計算。玻璃傳熱系數(shù)計算方法可按本規(guī)程附錄A執(zhí)行,玻璃遮陽系數(shù)可按現(xiàn)行國家標(biāo)準(zhǔn)《建筑玻璃可見光透射比、太陽光直接透射比、太陽能總透射比、紫外線透射比及有關(guān)窗玻璃參數(shù)的測定》GB/T2680執(zhí)行。3.2.3設(shè)計使用中空玻璃時,宜進(jìn)行玻璃結(jié)露點(diǎn)計算,計算方法可按本規(guī)程附錄B執(zhí)行。3.2.4當(dāng)考慮地震作用時,風(fēng)荷載和地震作用應(yīng)按荷載效應(yīng)基本組合進(jìn)行荷載(效應(yīng))組合,且建筑玻璃的最大許用跨度可按照本規(guī)程第5.2節(jié)的方法進(jìn)行計算。

4材料

4.1玻璃4.1.1建筑物可根據(jù)功能要求選用平板玻璃、中空玻璃、真空玻璃、鋼化玻璃、半鋼化玻璃、夾層玻璃、光伏玻璃、夾絲玻璃、著色玻璃、鍍膜玻璃、壓花玻璃、U型玻璃等。

4.11《平板玻璃》GB116142《建筑用安全玻璃第2部分:鋼化玻璃》GB15763.23《建筑用安全玻璃第3部分:夾層玻璃》GB15763.34《建筑用安全玻璃第4部分:均質(zhì)鋼化玻璃》GB15763.45《半鋼化玻璃》GB178416《中空玻璃》GB/T119447《著色玻璃》GB/T187018《鍍膜玻璃第一部分陽光控制鍍膜玻璃》GB/T18915.19《鍍膜玻璃第二部分低輻射鍍膜玻璃》GB/T18915.210《建筑用太陽能光伏夾層玻璃》GB2955111《建筑用太陽能光伏中空玻璃》GB/T2975912《建筑門窗幕墻用鋼化玻璃》JG/T45512《真空玻璃》JC/T107913《夾絲玻璃》JC43314《壓花玻璃》JC/51115《U型玻璃》JC/T8674.1.3用于門窗幕墻的鋼化玻璃必須符合《建筑門窗幕墻用鋼化玻璃》JG/T455標(biāo)準(zhǔn)規(guī)定。4.1.4建筑玻璃強(qiáng)度設(shè)計值可按下式計算:(4.1.4)式中:——建筑玻璃強(qiáng)度設(shè)計值;——玻璃種類系數(shù);——玻璃強(qiáng)度位置系數(shù);——荷載類型系數(shù);——玻璃厚度系數(shù);——短期荷載作用下,平板玻璃中部強(qiáng)度設(shè)計值,取28MPa。4.1.5玻璃種類系數(shù)應(yīng)按表4.1.5取值。表4.1.5玻璃種類系數(shù)玻璃種類平板玻璃半鋼化玻璃鋼化玻璃夾絲玻璃壓花玻璃1.01.6~2.02.5~3.00.50.64.1.6玻璃強(qiáng)度位置系數(shù)應(yīng)按表4.1.6取值。表4.1.6玻璃強(qiáng)度位置系數(shù)強(qiáng)度位置中部強(qiáng)度邊緣強(qiáng)度端面強(qiáng)度1.00.80.74.1.7荷載類型系數(shù)應(yīng)按表4.1.7取值。表4.1.7荷載類型系數(shù)荷載類型平板玻璃半鋼化玻璃鋼化玻璃短期荷載1.01.01.0長期荷載0.310.500.504.1.8玻璃厚度系數(shù)應(yīng)按表4.1.8取值。表4.1.8玻璃厚度系數(shù)玻璃厚度4mm~12mm15mm~≥20mm1.000.850.704.1.9在短期荷載下,平板玻璃、半鋼化玻璃和鋼化玻璃強(qiáng)度設(shè)計值可按表4.1.9取值。表4.1.9短期荷載下玻璃強(qiáng)度設(shè)計值fg(N/mm2)種類厚度(mm)中部強(qiáng)度邊緣強(qiáng)度端面強(qiáng)度平板玻璃4~1228222015~19241917≥20201614半鋼化玻璃4~1256444015~19483834≥20403228鋼化玻璃4~1284675915~19725851≥205947424.1.10在長期荷載作用下,平板玻璃、半鋼化玻璃和鋼化玻璃強(qiáng)度設(shè)計值可按表4.1.10取值。表4.1.10長期荷載作用下玻璃強(qiáng)度設(shè)計值fg(N/mm2)種類厚度(mm)中部強(qiáng)度邊緣強(qiáng)度端面強(qiáng)度平板玻璃4~1297615~19765≥20654半鋼化玻璃4~1228222015~19241917≥20201614鋼化玻璃4~1242343015~19362926≥20302421注:1.鋼化玻璃強(qiáng)度設(shè)計值可達(dá)平板玻璃強(qiáng)度設(shè)計值的2.5~3.0倍,表中數(shù)值是按3倍取的;如實(shí)測達(dá)不到3倍,可按2.5倍取值,也可根據(jù)實(shí)測結(jié)果予以調(diào)整。2.半鋼化玻璃強(qiáng)度設(shè)計值可達(dá)平板玻璃強(qiáng)度設(shè)計值的1.6~2.0倍,表中數(shù)值是按2倍取的;如達(dá)不到2倍,可按1.6倍取值,也可根據(jù)實(shí)測結(jié)果予以調(diào)整。4.1.11夾層玻璃和中空玻璃強(qiáng)度設(shè)計值應(yīng)按所采用玻璃類型確定。4.1.12對建筑玻璃有熱工性能要求時應(yīng)選用中空玻璃,對玻璃熱工性能要求較高時,可采取下列措施:1可采用三玻兩空玻璃,內(nèi)外片每片玻璃厚度不應(yīng)小于4mm,玻璃厚度差不宜超過3mm,空氣間隔層厚度不宜小于9mm。2.可采用Low-e玻璃,其鍍膜面應(yīng)位于中空玻璃空氣腔中。當(dāng)另外一片采用在線low-e玻璃,其鍍膜面應(yīng)位于室內(nèi)側(cè)。3.可以充惰性氣體,但中空玻璃間隔條應(yīng)采用連續(xù)折彎且對接縫處做密封處理。4.可采用暖邊間隔條。5.當(dāng)中空玻璃制作與使用地理位置有較大氣壓變化時,宜采用呼吸管平衡裝置,且在使用地對呼吸管做封閉密封處理。6.當(dāng)設(shè)計要求中空玻璃避免由于溫度變化產(chǎn)生表面變形時,中空玻璃可采用毛細(xì)管技術(shù)。4.1.13光伏構(gòu)件用玻璃宜采用超白平板玻璃、超白半鋼化玻璃或超白鋼化玻璃。采用超白鋼化玻璃應(yīng)進(jìn)行均質(zhì)處理。光伏玻璃的厚度應(yīng)經(jīng)計算在3mm—5mm范圍內(nèi)選取,其設(shè)計許用強(qiáng)度可按式(4.1.4)計算,玻璃厚度系數(shù)取1.0。4.2玻璃組裝材料4.2.1《聚氨酯建筑密封膠》JC/T4822《聚硫建筑密封膠》JC/T4833《丙烯酸酯建筑密封膠》JC/T4844《建筑窗用彈性密封膠》JC/T4855《硅酮建筑密封膠》GB/T146836《塑料門窗用密封條》GB120027《建筑橡膠密封墊預(yù)成型實(shí)心硫化的結(jié)構(gòu)密封墊用材料規(guī)范》HG/T30998《建筑用硅酮結(jié)構(gòu)密封膠》GB167769《玻璃幕墻璃接縫用密封膠》JC/T88210《建筑物隔熱用硬質(zhì)聚氨酯泡沫塑料》GB108004.2.4.2.34.2.4玻璃安裝材料應(yīng)與玻璃及周邊材料相容。

5建筑玻璃抗風(fēng)壓設(shè)計

5.1風(fēng)荷載計算5.1.1作用在建筑玻璃上的風(fēng)荷載設(shè)計值應(yīng)按下式計算:

式中:w——風(fēng)荷載設(shè)計值,kPa;——風(fēng)荷載標(biāo)準(zhǔn)值,kPa;——風(fēng)荷載分項(xiàng)系數(shù),取1.4。5.1.25.2抗風(fēng)壓設(shè)計5.2.1用于室外的建筑玻璃應(yīng)進(jìn)行抗風(fēng)壓設(shè)計,并應(yīng)同時滿足承載力極限狀態(tài)和正常使用極限狀態(tài)的要求。幕墻玻璃抗風(fēng)壓設(shè)計應(yīng)按5.2.2除中空玻璃以外的建筑玻璃承載力極限狀態(tài)設(shè)計,可采用考慮幾何非線性的有限元法進(jìn)行計算,且最大應(yīng)力設(shè)計值不應(yīng)超過短期荷載作用下玻璃強(qiáng)度設(shè)計值1最大許用跨度可按下式計算:(5.2.2)式中:w——風(fēng)荷載設(shè)計值,kPa;L——玻璃最大許用跨度,mm;、、、——常數(shù),根據(jù)玻璃的長寬比進(jìn)行取值。2、、、的取值應(yīng)符合下列規(guī)定:1)對于四邊支承和兩對邊支承的單片平板矩形玻璃、單片半鋼化矩形玻璃、單片鋼化矩形玻璃和普通夾層矩形玻璃,其、、、可按本規(guī)程附錄C取值。夾層玻璃的厚度應(yīng)為去除膠片后玻璃凈厚度和。三邊支撐可按兩對邊支撐取值。2)對于夾絲玻璃和壓花玻璃,其、、、可按本規(guī)程附錄C中平板玻璃的、、、取值。按本規(guī)程式5.2.2計算玻璃最大許用跨度時,風(fēng)荷載設(shè)計值應(yīng)按本規(guī)程式5.1.1的計算值除以玻璃種類系數(shù)取值。3)對于真空玻璃,其、、、可按本規(guī)程附錄C中普通夾層玻璃的、、、取值。4)對于半鋼化夾層玻璃和鋼化夾層玻璃,其、、、可按本規(guī)程附錄C中普通夾層玻璃的、、、取值。按本規(guī)程式5.2.2計算玻璃最大許用跨度時,風(fēng)荷載設(shè)計值應(yīng)按本規(guī)程式5.1.1的計算值除以玻璃種類系數(shù)取值。5)當(dāng)玻璃的長寬比超過5時,玻璃的、、、應(yīng)按長寬比等于5進(jìn)行取值。6)當(dāng)玻璃的長寬比不包含在本規(guī)程附錄C中時,可先分別計算玻璃相鄰兩長寬比條件下的最大許用跨度,再采用線性插值法計算其最大許用跨度。5.2.3除中空玻璃以外的建筑玻璃正常使用極限狀態(tài)設(shè)計,可采用考慮幾何非線性的有限元法計算,且撓度限值([d])應(yīng)小于跨度(a)的1/60。四邊支承和兩對邊支承矩形玻璃正常使用極限狀態(tài)也可按下列規(guī)定設(shè)計:1四邊支承和兩對邊支承矩形玻璃單位厚度跨度限值應(yīng)按下式計算:(5.2.3)式中:——玻璃單位厚度跨度限值;——風(fēng)荷載標(biāo)準(zhǔn)值,kPa;、、、——常數(shù),可按本規(guī)程附錄C取值。2設(shè)計玻璃跨度(a)除以玻璃厚度(t),不應(yīng)大于玻璃單位厚度跨度限值。如果大于,就增加玻璃厚度,直至小于。5.1直接承受風(fēng)荷載作用的單片玻璃:(5.2.4-1)式中:——荷載分配系數(shù);——外片玻璃厚度,mm;——內(nèi)片玻璃厚度,mm。2不直接承受風(fēng)荷載作用的單片玻璃:(5.2.4-2)式中:——荷載分配系數(shù);——外片玻璃厚度,mm;——內(nèi)片玻璃厚度,mm。5.2.5中空玻璃的承載力極限狀態(tài)設(shè)計和正常使用極限狀態(tài)設(shè)計,可根據(jù)分配到每片玻璃上的風(fēng)荷載,采用本規(guī)程第5.2.2條~第5.2.3條的方法進(jìn)行計算。

6建筑玻璃防熱炸裂設(shè)計與措施6.1防熱炸裂設(shè)計6.1.1當(dāng)平板玻璃、著色玻璃、鍍膜玻璃、壓花玻璃和夾絲玻璃明框安裝且位于向陽面時,應(yīng)進(jìn)行熱應(yīng)力計算,且玻璃邊部承受的最大應(yīng)力值不應(yīng)超過半鋼化玻璃和鋼化玻璃可不進(jìn)行熱應(yīng)力計算。6.1.2玻璃端面強(qiáng)度設(shè)計值可按本規(guī)程式4.1.3計算,也可按表6.1.2取值。表6.1.2玻璃端品種厚度(mm)端面設(shè)計值(MPa)平板玻璃著色玻璃鍍膜玻璃3~122015~1917壓花玻璃6,8,1012夾絲玻璃6,8,1010注:夾層玻璃、真空玻璃和中空玻璃端面強(qiáng)度設(shè)計值與單片玻璃的相同。6.1.3σh=0.74Eμ1μ2μ3μ4(Tc-Ts)(6.1.3式中:σh——玻璃端面應(yīng)力,MPa;E——玻璃彈性模量,可按0.72MPa取值;——玻璃線膨脹系數(shù),可按/℃取值;μ1——陰影系數(shù),按表6.1.3-1取值μ2——窗簾系數(shù),按表6.1.3-2取值μ3——玻璃面積系數(shù),按表6.1.3-3取值μ4——邊緣溫度系數(shù),按表6.1.3-4取值Tc——玻璃中部溫度,其計算方法應(yīng)符合本規(guī)程附錄D的規(guī)定;Ts——窗框溫度,其計算方法應(yīng)符合本規(guī)程附錄D的規(guī)定。表6.1.3-1表6.1.3-2窗簾形式薄的絲織品厚絲織品百葉窗窗簾與玻璃的距離(mm)<100≥100<100≥100系數(shù)1.31.11.51.3表6.1.3-3面積(m2)0.51.01.52.02.53.04.05.06.0系數(shù)0.951.001.041.071.091.101.121.141.16表6.1.3-4安裝形式固定窗開啟扇油灰、非結(jié)構(gòu)密封墊0.950.75實(shí)心條+彈性密封膠0.800.65泡沫條+彈性密封膠0.650.50結(jié)構(gòu)密封墊0.550.486.2防熱炸裂措施6.2.1建筑玻璃安裝時,不得6.2.2建筑玻璃內(nèi)側(cè)窗簾、百葉窗及其他遮蔽物與玻璃之間

7建筑玻璃防人體沖擊規(guī)定7.1一般規(guī)定7.1.1安全玻璃的最大許用面積應(yīng)符合表7.1.1-1的規(guī)定;有框平板玻璃、真空玻璃和表7.1.1玻璃種類公稱厚度(mm)最大許用面積(m2)鋼化玻璃456810122.02.03.04.05.06.0夾層玻璃6.386.767.528.388.769.5210.3810.7611.5212.3812.7613.523.05.07.08.0表7.1.1-2有框平板玻璃、真空玻璃玻璃種類公稱厚度(mm)最大許用面積(m2)有框平板玻璃真空玻璃3456810120.10.30.50.91.82.74.5夾絲玻璃67100.91.82.47.1.2

7.2玻璃的選擇7.2.1活動門1有框玻璃應(yīng)使用符合本規(guī)程表7.1.2無框玻璃應(yīng)使用公稱厚度不小于12mm7.2.2室內(nèi)隔斷應(yīng)使用安全玻璃,且最大使用面積應(yīng)符合本規(guī)程表7.1.1-1的規(guī)定7.2.31有框玻璃應(yīng)使用符合本規(guī)程表7.1.1-1的規(guī)定、且公稱厚度不小于2無框玻璃應(yīng)使用符合本規(guī)程表7.1.1-1的規(guī)定、7.1浴室內(nèi)有框玻璃應(yīng)使用符合本規(guī)程表7.1.1-1規(guī)定、且公稱厚度不小于2浴室內(nèi)無框玻璃應(yīng)使用符合本規(guī)程表7.1.1-1規(guī)定、且公稱厚度不小于7.2.51有立柱和扶手,欄板玻璃作為鑲嵌面板安裝在護(hù)欄系統(tǒng)中,欄板玻璃應(yīng)使用符合本規(guī)程表7.1.1-1的規(guī)定、且公稱厚度不小于5mm的鋼化玻璃,或公稱厚度不小于2護(hù)欄系統(tǒng)中,沒有立柱和扶手,欄板玻璃直接生根在地面上;或沒有立柱,扶手生根在欄板玻璃上,欄板玻璃直接生根在地面上;或有立柱,但沒有扶手,欄板玻璃應(yīng)使用符合本規(guī)程表7.1.1-1的規(guī)定、且公稱厚度不小于12mm的鋼化玻璃或公稱厚度不小于16.76mm鋼化夾層玻璃。當(dāng)欄板玻璃最低點(diǎn)離一側(cè)樓地面高度在3m或3m以上、5m或5m以下時,應(yīng)使用公稱厚度不小于16.76mm鋼化夾層玻璃。7.2.6室外欄板玻璃應(yīng)進(jìn)行玻璃抗風(fēng)壓設(shè)計。7.2.7室內(nèi)飾面玻璃應(yīng)符合下列規(guī)定:1室內(nèi)飾面玻璃可采用平板玻璃、釉面玻璃、鏡面玻璃、夾絲玻璃、鋼化玻璃和夾層玻璃等,其許用面積應(yīng)分別符合本規(guī)程表7.1.1-1和表7.1.1-2的規(guī)定。2當(dāng)室內(nèi)飾面玻璃最高點(diǎn)離樓地面高度在3m或3m以上時,應(yīng)使用夾層玻璃。3室內(nèi)飾面玻璃邊部應(yīng)進(jìn)行精磨和倒角處理,自由邊應(yīng)進(jìn)行拋光處理。4室內(nèi)消防通道墻面不宜采用飾面玻璃。5室內(nèi)飾面玻璃可采用點(diǎn)式幕墻和隱框幕墻安裝方式。龍骨應(yīng)與結(jié)構(gòu)樓板、梁或墻體連接牢固。龍骨和結(jié)構(gòu)膠應(yīng)通過結(jié)構(gòu)計算確定。7.3保護(hù)措施7.37.3.2根據(jù)易發(fā)生碰撞的建筑玻璃所處的具體部位,可采取在視線高度設(shè)醒目標(biāo)志或設(shè)置護(hù)欄等防碰撞措施。

8百葉窗玻璃和屋面玻璃設(shè)計8.1百葉窗玻璃

8.1.1當(dāng)風(fēng)荷載標(biāo)準(zhǔn)值不大于1.0kPa時,百葉窗使用的平板玻璃最大許用表8.1.1百葉窗使用的平板公稱厚度(mm)玻璃寬度aa≤100100<a≤150150<a≤2254500600不允許使用560075075067509009008.1.2當(dāng)風(fēng)荷載標(biāo)準(zhǔn)值大于1.0kPa時,百葉窗玻璃最大許用跨度應(yīng)按本規(guī)程第5章進(jìn)行驗(yàn)算。

8.1.3安裝在易受人體沖擊位置時,百葉窗玻璃除應(yīng)符合本規(guī)程第8.1.1條或第8.18.2屋面玻璃8.2.18.2.2屋面玻璃或雨蓬玻璃必須使用夾層玻璃,8.2.3當(dāng)夾層玻璃采用PVB膠片且有裸露邊時,其自由邊應(yīng)作封邊處理。8.2.4上人屋面玻璃應(yīng)按地板玻璃進(jìn)行設(shè)計。8.2.5不上人屋面的活荷載除應(yīng)符合現(xiàn)行國家標(biāo)準(zhǔn)《建筑結(jié)構(gòu)荷載規(guī)范》GB50009的規(guī)定外,尚應(yīng)符合下列規(guī)定:1與水平面夾角小于30°的屋面玻璃,在玻璃板中心點(diǎn)直徑為150mm的區(qū)域內(nèi),應(yīng)能承受垂直于玻璃為1.1kN的活荷載標(biāo)準(zhǔn)值;2與水平面夾角大于或等于30°的屋面玻璃,在玻璃板中心直徑為150mm的區(qū)域內(nèi),應(yīng)能承受垂直玻璃為0.5kN的活荷載標(biāo)準(zhǔn)值。8.2.6當(dāng)屋面玻璃采用中空玻璃時,集中活荷載應(yīng)只作用中空玻璃上片玻璃。8.2.7屋面玻璃或雨蓬的最大應(yīng)力設(shè)計值應(yīng)按彈性力學(xué)計算,且最大應(yīng)力不得超過長期荷載作用下的強(qiáng)度設(shè)計值。8.2.8屋面玻璃或雨蓬的強(qiáng)度設(shè)計值可按本規(guī)程式4.1.3計算,也可按本規(guī)程表4.1.9取值。8.2.9屋面玻璃或雨篷玻璃應(yīng)有適當(dāng)?shù)呐潘露?,其自重下的變形?yīng)不影響排水。8.3其他8.3.1斜面玻璃宜采用夾層玻璃。8.3.2吊頂玻璃應(yīng)符合下列規(guī)定:1吊頂玻璃應(yīng)采用夾層玻璃。2玻璃吊頂可采用四邊支承方式,也可采用點(diǎn)支承倒掛方式。3吊頂玻璃宜采用磨砂玻璃、彩繪玻璃和彩釉玻璃等非透明玻璃。4吊頂玻璃應(yīng)進(jìn)行自身重力荷載下的變形設(shè)計計算,可采用彈性力學(xué)方法進(jìn)行計算。對于四邊支承玻璃板,其撓度限值不應(yīng)超過其跨度的1/300和2mm兩者中的最小值。對于點(diǎn)支承玻璃板,其撓度限值不應(yīng)超過其支承點(diǎn)間長邊邊長的1/300和2mm兩者中的最小值。

9地板玻璃設(shè)計9.1一般規(guī)定9.1.19.1.2地板玻璃必須采用夾層玻璃,點(diǎn)支承地板玻璃必須采用鋼化夾層玻璃9.1.9.1.49.1.5地板夾層玻璃的單片厚度相差不宜大于3mm9.1.6框支承地板玻璃單片厚度不宜小于9.1.7地板玻璃之間的接縫不應(yīng)小于6mm,9.9.1.9地板玻璃承受的風(fēng)荷載和活荷載應(yīng)符合現(xiàn)行國家標(biāo)準(zhǔn)《建筑結(jié)構(gòu)荷載規(guī)范》GB50009的規(guī)定9.1.10地板玻璃板面撓度不應(yīng)9.1.11地板玻璃最大應(yīng)力不得超過長期荷載作用下的強(qiáng)度設(shè)計值,玻璃在長期荷載作用下的強(qiáng)度設(shè)計值可按本規(guī)程式4.1.3計算,也可按本規(guī)程9.2框支承地板玻璃設(shè)計計算9.2.1框支承地板玻璃強(qiáng)度計算時,9.2.(9.2.2式中:—分配到第i片玻璃上的荷載基本組合設(shè)計值;—第i片玻璃的厚度;—夾層玻璃的等效厚度?!饔迷诘匕宀A虾奢d基本組合設(shè)計值。9.2.3夾層玻璃的等效厚度((9.2.3式中:—夾層玻璃的等效厚度;—分別為各單片玻璃的厚度;—夾層玻璃的層數(shù)。9.2(9.2.4式中:—第i片玻璃的最大應(yīng)力,;—作用于第i片地板玻璃的荷載基本組合設(shè)計值,;—矩形玻璃板短邊邊長,mm;—玻璃的厚度,mm;-彎矩系數(shù),可根據(jù)玻璃板短邊與長邊的長度之比按表9.2.表9.2.4四邊支承玻璃板的彎矩數(shù)0.000.250.330.400.500.550.600.650.12500.12300.11800.11150.10000.09340.08680.08040.700.750.800.850.900.951.00——0.07420.06830.06280.05760.05280.04830.0442——注:是玻璃板短邊與長邊的長度之比。9.2.5計算框支承地板夾層玻璃的最大撓度可按等效單片玻璃計算。計算框支承地板夾層玻璃9.2.6在垂直于玻璃平面的荷載作用下,框支承地板玻璃的單片玻璃的最大撓度(9.2.6(9.2.6-2式中:—在垂直于地板玻璃的荷載標(biāo)準(zhǔn)組合值作用下最大撓度,mm;—垂直于該片地板玻璃的荷載標(biāo)準(zhǔn)組合值,;—撓度系數(shù),可根據(jù)玻璃短邊與長邊的長度之比按表9.2.6—玻璃的剛度,;—玻璃的彈性模量,可按0.72取值;—泊松比,可按0.2取值。表9.2.60.000.200.250.330.500.550.600.650.013020.012970.012820.012230.010130.009400.008670.007960.700.750.800.850.900.951.00——0.007270.006630.006030.005470.004960.004490.00406——注:是玻璃板短邊與長邊的長度之比。9.3四點(diǎn)支承地板玻璃設(shè)計計算9.3.1(9.3.1)式中:—第i片玻璃的最大應(yīng)力,;—作用于第i片地板玻璃的荷載基本組合設(shè)計值,;—支承點(diǎn)間玻璃面板長邊邊長,mm;—玻璃的厚度,mm;—彎矩系數(shù),可根據(jù)支承點(diǎn)間玻璃板短邊與長邊的長度之比按表9.3.1取值表9.3.1四點(diǎn)支承玻璃板的彎矩系數(shù)0.000.200.300.400.500.550.600.650.1250.1260.1270.1290.1300.1320.1340.1360.700.750.800.850.900.951.0——0.1380.1400.1420.1450.1480.1510.154——注:是玻璃板短邊與長邊的長度之比。9.3.2夾層玻璃的撓度可按單片玻璃計算,但在計算玻璃剛度9.3.3(9.3.3(9.3.3-2式中:—在垂直于該片地板玻璃的荷載標(biāo)準(zhǔn)值作用下的撓度最大值,mm;—垂直于該片地板玻璃的荷載標(biāo)準(zhǔn)組合值,;—撓度系數(shù),可根據(jù)玻璃支承點(diǎn)間短邊與長邊的長度之比按表9.3.—玻璃的剛度,;—玻璃的彈性模量,可按0.72取值;—泊松比。表9.3.3四點(diǎn)支承板的撓度系數(shù)0.000.200.300.400.500.550.600.650.013020.013170.013350.013670.014170.014510.014960.015550.700.750.800.850.900.951.00.016300.017250.018420.019840.021570.023630.02603注:是玻璃板短邊與長邊的長度之比。

10水下用玻璃設(shè)計

10.1水下用玻璃的性能要求

10.1.1水下用玻璃應(yīng)選用夾層玻璃。夾層玻璃中任何一片玻璃破裂,夾層玻璃的承載力應(yīng)滿足要求。10.1.2水下用玻璃的設(shè)計應(yīng)滿足下式的要求:σ≤fg(10.式中:σ—水壓作用產(chǎn)生的玻璃截面最大彎曲應(yīng)力設(shè)計值,MPa;fg—長期荷載作用下玻璃的強(qiáng)度設(shè)計值,可按本規(guī)程式4.1.3計算,也可按本規(guī)程表4.1.9采用。10.1.3承受水壓時,水下用玻璃板的撓度不得大于其跨度的1/200;安裝框架的撓度不得超過其跨度的1/500。10.2水下用玻璃的設(shè)計計算10.2.1四邊支承矩形玻璃的最大彎曲應(yīng)力設(shè)計值及最大撓度應(yīng)按下列公式計算(圖10.(10.2.1-1)(10.2.1-2)式中:σ—玻璃中部最大彎曲應(yīng)力設(shè)計值,MPa;u—玻璃中部最大撓度,mm;ρ—水密度,淡水按1.00×103取值,海水按1.01×103~1.05×103取值,kg/m3;H—水深,m;L—跨度,m;t—單片玻璃厚度,mm;n—構(gòu)成夾層玻璃的單片玻璃數(shù);β1、α1—玻璃邊長比相關(guān)系數(shù),應(yīng)按表10.2.1-1及表10.2.1-2取值。圖10.2.1-1四邊支承矩形側(cè)面玻璃表10.2.1-1系數(shù)βH/ak1.01.21.41.61.82.02.53.04.06.010.0∞1.01.571.701.871.972.052.112.242.322.432.542632.761.22.002.242.432.572.682.782.953.073.203.353.483.661.42.372.692.923.103.253.373.573.713.894.074.224.441.62.693.063.343.553.713.854.094.254.464.674.845.101.82.953.363.673.914.104.244.514.694.935.165.355.632.03.153.603.944.204.404.564.845.055.305.555.756.052.53.494.004.394.674.905.085.405.625.906.196.416.743.03.664.224.624.935.165.355.695.936.236.526.767.114.03.804.384.805.125.365.565.936.176.486.797.037.405.03.834.424.855.175.425.625.986.236.546.857.107.48注:k—長邊與短邊之比。表10.2.1-2系數(shù)α1值H/ak1.01.21.41.61.82.02.53.04.06.010.0∞1.03.093.593.934.204.414.584.885.095.345.605.796.091.24.284.965.465.846.146.366.787.077.347.778.068.481.45.346.416.847.327.687.988.518.879.339.7510.1110.641.66.267.268.038.589.009.369.9810.4010.9111.4311.8512.471.87.018.168.999.6210.1010.4911.1911.6612.2412.8113.2813.982.07.618.879.7810.4610.9811.4012.1712.6813.3113.9414.4515.202.58.6310.0711.0911.8712.4712.9513.8014.3715.0915.8116.3817.253.09.1810.7111.8112.6213.2613.7714.6915.2916.0516.8217.4318.354.09.6211.2212.3813.2313.8914.4315.3816.0216.8317.6318.2719.235.09.7411.3612.5113.3814.0614.6015.5716.2217.0317.8418.4819.46注:k—長邊與短邊之比。2三邊支承矩形玻璃的最大彎曲應(yīng)力設(shè)計值及最大撓度應(yīng)按下列公式計算(圖10.2.1-2)圖10.2.1-2三邊支承矩形側(cè)面玻璃玻璃中部:(10.2.1-3)玻璃邊部:(10.2.1-4)玻璃中部:(10.2.1-5)玻璃邊部:(10.2.1-6)式中:σ邊—玻璃邊緣中心處最大彎曲應(yīng)力設(shè)計值,MPa;u邊—玻璃邊緣中心處最大撓度,mm;β2、β3、α2、α3—與玻璃邊長比有關(guān)的系數(shù),應(yīng)按表10.2.1-3取值。表10.2.1-3系數(shù)β2、β3、α2、α3值b/a部位系數(shù)0.50.671.01.52.0中部β20.871.321.992.723.17α22.033.114.706.688.00邊部β31.181.591.951.851.55α33.454.565.525.214.373周邊連續(xù)支承圓形玻璃板的最大彎曲應(yīng)力設(shè)計值及最大撓度應(yīng)按下列公式計算(圖10.2.1-3)。圖10.2.1-3周邊連續(xù)支承圓形側(cè)面玻璃(10.2.1-7)(10.2.1-8)式中:L—圓形水槽玻璃的半徑,m;β4、α4—與玻璃半徑有關(guān)的系數(shù),應(yīng)按表10.2.1-4取值。表10.2.1-4β4、α4系數(shù)值H/L1.01.21.41.61.82.02.53.04.06.0∞β46.487.387.988.528.889.249.7810.2010.6811.1612.20α449.5057.6063.4567.8071.1073.8078.7582.0586.1090.3098.4010.1四邊支承矩形玻璃的最大彎曲應(yīng)力設(shè)計值及最大撓度應(yīng)按下列公式計算(圖10.2.2圖10.2.2(10.2.2-1)(10.2.2-2)式中:β5、α5——與玻璃邊長比有關(guān)的系數(shù),應(yīng)按表10.2.2-1取值表10.2.2-1β5、α5b/a1.01.21.41.61.82.03.04.06.0∞β52.723.624.415.075.606.037.117.407.487.50α56.308.7611.1012.8714.5215.7519.0420.0020.1320.272周邊連續(xù)支承圓形玻璃的最大彎曲應(yīng)力設(shè)計值及最大撓度應(yīng)按下列公式計算(圖10.2.2圖10.2.2(10.2.2-3)(10.2.2-4)

11U形玻璃墻設(shè)計與施工

11.1一般規(guī)定

11.1.1U形玻璃應(yīng)符合行業(yè)標(biāo)準(zhǔn)《建筑用U形玻璃》JC/T867的規(guī)定。用于建筑外圍護(hù)結(jié)構(gòu)的U形玻璃,其外觀質(zhì)量應(yīng)符合行業(yè)標(biāo)準(zhǔn)《建筑用U形玻璃》JC/T867優(yōu)等品的規(guī)定,且應(yīng)進(jìn)行鋼化處理。[條文說明]用于建筑外圍護(hù)結(jié)構(gòu)的U型玻璃質(zhì)量應(yīng)優(yōu)選;鋼化處理能增加其強(qiáng)度和安全性11.1.2對U形玻璃墻體有熱工或隔聲性能要求時,應(yīng)采用雙排U形玻璃構(gòu)造,必要時可在雙排U形玻璃之間設(shè)置保溫棉或吸音棉。雙排U形玻璃可以采用對縫布置,也可采用錯縫布置。[條文說明]U型玻璃是非透明產(chǎn)品,在雙排U型玻璃之間設(shè)置保溫棉或吸音棉,可增加其熱工性能或隔聲性能,且視覺上不可見。11.1.3采用U形玻璃構(gòu)造曲形墻體時,底寬260mm的U型玻璃,墻體的半徑不小于2000mm;底寬330mm的U型玻璃,墻體的半徑不小于3200mm;底寬500mm的U型玻璃,墻體的半徑不小于7500m。11.1.4當(dāng)U形玻璃高度超過4.5m時,應(yīng)考慮其結(jié)構(gòu)穩(wěn)定性,必要時采取相應(yīng)措施。11.2U形玻璃的設(shè)計計算11.2.1U形玻璃用于外墻時應(yīng)進(jìn)行風(fēng)荷載作用下的承載力設(shè)計,有抗震設(shè)計要求時尚應(yīng)考慮地震作用。風(fēng)荷載和地震作用及其組合應(yīng)按第3章執(zhí)行。11.2.2U形玻璃設(shè)計許用強(qiáng)度應(yīng)取17MPa,鋼化U形玻璃設(shè)計許用強(qiáng)度應(yīng)取51MPa。11.2.3U形玻璃的承載力可按下式計算:(11.2.3)式中——U形玻璃的軸力設(shè)計值(N);——U形玻璃的彎矩設(shè)計值(Nmm);——U形玻璃的凈截面面積(mm2);——U形玻璃在彎矩作用下的凈截面抵抗矩(mm3);——U形玻璃截面塑性發(fā)展系數(shù),可取1.00;——U形玻璃的設(shè)計強(qiáng)度設(shè)計值(N/mm2)。[條文說明]按簡支梁模型計算。11.2.4在風(fēng)荷載標(biāo)準(zhǔn)值作用下,U型玻璃的撓度u應(yīng)符合下列要求:(11.2.4)式中——U形玻璃的撓度(mm);——U形玻璃長度(mm)。11.3安裝及配套材料11.3.1U型玻璃墻四周結(jié)構(gòu)框體可采用鋁型材或鋼型材,并用膨脹螺栓固定。11.3.2U型玻璃應(yīng)各自獨(dú)立支撐在具有均勻彈性的襯墊上。11.3.3U形玻璃與周邊的金屬件、混凝土和砂漿結(jié)構(gòu)之間不得有硬性接觸。11.3.4在U型玻璃的上端與更高處的建筑物件(如過梁、大梁、屋面板等)之間應(yīng)留有縫隙。11.3.5在U型玻璃上端與臨近的上部結(jié)構(gòu)之間應(yīng)有不小于25mm縫隙。11.3.6U型玻璃之間的縱向縫應(yīng)采用彈性密封材料填充。11.3.7緩沖墊為塑料或橡膠等軟性耐腐材料,作用為避免U型玻璃與硬性材料直接接觸。11.3.8密封材料通常有二組分的聚硫塑料、硅銅膠、柔性聚氯乙烯型材等,用于U型玻璃與固定件、U形玻璃條之間的密封。11.3.9圓繩用于U型玻璃與邊框之間的密封。11.3.10條形襯墊、柔性聚氯乙烯型材、浸過瀝青的條帶、硬泡沫塑料等,用作U型玻璃與邊框之間的脹縫和滑縫。12安裝12.1裝配尺寸要求12.1.1單片玻璃、夾層玻璃和真空玻璃的最小裝配尺寸應(yīng)符合表12.1.1-1的規(guī)定。中空玻璃的最小安裝尺寸應(yīng)符合表12.1.1-2的規(guī)定(圖12.1.1)。表12.1.1-1單片玻璃、夾層玻璃和真空玻璃的最小裝配尺寸(mm)玻璃公稱厚度前部余隙和后部余隙a嵌入深度b邊緣間隙c密封膠膠條3~63.03.08.04.08~105.03.510.05.012~194.012.08.0圖12.1.1玻璃安裝尺寸表12.1.1-2中空玻璃的最小安裝尺寸(mm)玻璃公稱厚度前部余隙和后部余隙a嵌入深度b邊緣間隙c密封膠膠條4+A+45.03.515.05.05+A+56+A+68+A+87.05.017.07.010+A+1012+A+12注:A為氣體層的厚度,其數(shù)值可取6mm、9mm、12mm、15mm、16mm。12.1.2凹槽寬度應(yīng)等于前部余隙、玻璃公稱厚度和后部余隙之和。

12.1.3凹槽的深度應(yīng)等于邊緣間隙和嵌入深度之和。12.1.4幕墻玻璃的安裝尺寸應(yīng)按現(xiàn)行行業(yè)標(biāo)準(zhǔn)《玻璃幕墻工程技術(shù)規(guī)范》JGJ102的規(guī)定執(zhí)行。12.2玻璃安裝材料的使用12.2.1玻璃安裝材料應(yīng)與接觸材料相容,安裝材料的選用,應(yīng)通過相容性試驗(yàn)確定。12.2.2支承塊的尺寸應(yīng)符合下列規(guī)定:1每塊最小長度不得小于50mm;2寬度應(yīng)等于玻璃的公稱厚度加上前部余隙和后部余隙;3厚度應(yīng)等于邊緣間隙。12.2.3定位塊的尺寸應(yīng)符合下列規(guī)定:1長度不應(yīng)小于25mm;2寬度應(yīng)等于玻璃的厚度加上前部余隙和后部余隙;3厚度應(yīng)等于邊緣間隙。12.2.4支承塊與定位塊的位置應(yīng)符合下列規(guī)定(圖13.2.4):1采用固定安裝方式時,支承塊和定位塊的安裝位置應(yīng)距離槽角為1/10~1/4邊長位置之間;圖12.2.4支承塊和定位塊安裝位置

1—定位塊;2一玻璃;3一框架;4—支承塊

2采用可開啟安裝方式時,支承塊和定位塊的安裝位置距槽角不應(yīng)小于30mm。當(dāng)安裝在窗框架上的鉸鏈位于槽角部30mm和距槽角1/4邊長點(diǎn)之間時,支承塊和定位塊的安裝位置應(yīng)與鉸鏈安裝的位置一致;

3支承塊、定位塊不得堵塞泄水孔。12.2.5彈性止動片的尺寸應(yīng)符合下列規(guī)定:1長度不應(yīng)小于25mm;2高度應(yīng)比凹槽深度小3mm;3厚度應(yīng)等于前部余隙或后部余隙。12.2.6彈性止動片位置應(yīng)符合下列規(guī)定:1彈性止動片應(yīng)安裝在玻璃相對的兩側(cè),彈性止動片之間的間距不應(yīng)大于300mm;2彈性止動片安裝的位置不應(yīng)與支承塊和定位塊的位置相同。12.2.7密封膠的應(yīng)用應(yīng)符合下列規(guī)定:1對于多孔表面的框材,框材表面應(yīng)涂底漆。當(dāng)密封膠用于塑料門窗安裝時,應(yīng)確定其適用性和相容性;2用密封膠安裝時,應(yīng)使用支承塊、定位塊、彈性止動片;3密封膠上表面不應(yīng)低于槽口,并應(yīng)做成斜面;下表面應(yīng)低于槽口3mm。12.2.8膠條材料的應(yīng)用應(yīng)符合下列規(guī)定:1對于多孔表面的框材,框材表面應(yīng)涂底漆。膠條材料用于塑料門窗時,應(yīng)確定其適用性和相容性;2膠條材料用于玻璃兩側(cè)與槽口內(nèi)壁之間時,應(yīng)使用支承塊和定位塊。12.3玻璃抗側(cè)移的安裝要求12.3.1玻璃的四邊應(yīng)留有間隙,框架允許水平變形量應(yīng)大于因樓層變形引起的框架變形量。12.3.2框架允許水平變形量應(yīng)按下式計算:(12.3.2)式中:△u—框架允許水平變形量,mm;d—玻璃與框架縱向間隙,mm;c—玻璃與框架橫向間隙,mm;H—框架槽內(nèi)高度,mm;W—框架槽內(nèi)寬度,mm;S—誤差,可取2~3mm。12.3.3玻璃安裝采用的密封膠的位移能力級別不應(yīng)小于20HM。

附錄A玻璃傳熱系數(shù)值的計算方法A.0.1單片玻璃和夾層玻璃傳熱系數(shù)應(yīng)按下列方法計算:1玻璃熱導(dǎo)應(yīng)按下式計算:(A.0.1-1)式中:—玻璃熱導(dǎo),;—玻璃導(dǎo)熱系數(shù),;—玻璃厚度,夾層玻璃為除去膠片后玻璃的凈厚度,m。2單片玻璃和夾層玻璃傳熱系數(shù)應(yīng)按方法計算:(A.0.1-2)式中:—玻璃傳熱系數(shù),;—室外表面換熱系數(shù),;—玻璃熱導(dǎo),;—室內(nèi)表面換熱系數(shù),。A.0.2中空玻璃和真空玻璃傳熱系數(shù)應(yīng)按下列方法計算:1玻璃系統(tǒng)熱導(dǎo)應(yīng)按下式計算:(A.0.2-1)式中:—玻璃系統(tǒng)熱導(dǎo),;—中空玻璃氣體間隙層或真空玻璃間隙層熱導(dǎo),;—中空玻璃氣體層數(shù)量;—玻璃導(dǎo)熱系數(shù),;—組成玻璃系統(tǒng)各單片玻璃厚度之和,m。2中空玻璃氣體間隙層熱導(dǎo)應(yīng)按下式計算:(A.0.2-2)式中:——中空玻璃氣體間隙層氣體熱導(dǎo)(包括導(dǎo)熱和對流);——中空玻璃氣體間隙層內(nèi)兩片玻璃之間輻射熱導(dǎo)。3中空玻璃氣體間隙層氣體熱導(dǎo)應(yīng)按下式計算:(A.0.2-3)式中:——?dú)怏w層的厚度,m;——?dú)怏w導(dǎo)熱系數(shù),;——努塞爾準(zhǔn)數(shù)。4努塞爾準(zhǔn)數(shù)應(yīng)按下式計算:(A.0.2-4)式中:——常數(shù);——格拉曉夫準(zhǔn)數(shù);——普朗特準(zhǔn)數(shù);——冪指數(shù)。如果<1,則將取為1。5格拉曉夫準(zhǔn)數(shù)應(yīng)按下式計算:(A.0.2-5)6普朗特準(zhǔn)數(shù)應(yīng)按下式計算:(A.0.2-6)式中:——中空玻璃氣體間隙層兩玻璃內(nèi)表面的溫度差,K;——?dú)怏w密度,kg/m3;——?dú)怏w動態(tài)粘度,kg/(ms);——?dú)怏w比熱,J/(kgK);——玻璃平均溫度,K;垂直玻璃:=0.035,=0.38;水平玻璃:=0.16,=0.28;傾斜45度玻璃:=0.10,=0.31。7真空玻璃間隙層熱導(dǎo)應(yīng)按下式計算:(A.0.2-7)式中:——真空玻璃間隙層熱導(dǎo);——真空玻璃殘余氣體熱導(dǎo);——真空玻璃支撐物熱導(dǎo);——真空玻璃間隙層內(nèi)兩片玻璃之間輻射熱導(dǎo)。8真空玻璃殘余氣體熱導(dǎo)應(yīng)按下式計算:(A.0.2-8)式中;--真空玻璃中殘余氣體壓強(qiáng),Pa。9真空玻璃中支撐物熱導(dǎo)應(yīng)按下式計算:(A.0.2-9)式中:λ——玻璃導(dǎo)熱系數(shù),;——支撐物半徑,m;b——支撐物方陣間距,m。10中空玻璃氣體間隙層內(nèi)兩片玻璃之間輻射熱導(dǎo)和真空玻璃間隙層兩片玻璃之間輻射熱導(dǎo)應(yīng)按下式計算:(A.0.2-10)式中:和——中空玻璃氣體間隙層或真空玻璃間隙層兩片玻璃內(nèi)表面在平均絕對溫度Tm下的校正發(fā)射率。11中空玻璃和真空玻璃傳熱系數(shù)應(yīng)按下式計算:(A.0.2-11)式中:—中空玻璃和真空玻璃傳熱系數(shù),;—室外表面換熱系數(shù),;—玻璃系統(tǒng)熱導(dǎo),;—室內(nèi)表面換熱系數(shù),。A.0.3計算玻璃傳熱系數(shù)有關(guān)參數(shù)取值應(yīng)符合下列規(guī)定:1玻璃導(dǎo)熱系數(shù)λ應(yīng)按1取值。2未鍍低輻射膜玻璃表面校正發(fā)射率應(yīng)按0.837取值。3中空玻璃氣體間隙層兩玻璃內(nèi)表面的溫度差ΔT可按15K取值。4中空玻璃和真空玻璃平均溫度(Tm)可按283K取值。5斯蒂芬-波爾茲曼常數(shù)σ應(yīng)按5.67×10-8取值。6室外表面換熱系數(shù)應(yīng)按下式計算:(A.0.3-1)式中:——室外表面換熱系數(shù),;——玻璃表面附近風(fēng)速,m/s。一般情況下,可按23取值。7室內(nèi)表面換熱系數(shù)應(yīng)按下式計算:(A.0.3-2)式中:——室內(nèi)表面換熱系數(shù),;——玻璃室內(nèi)表面校正發(fā)射率。如果玻璃室內(nèi)表面未鍍低輻射膜,可按8取值。8氣體特性應(yīng)按表A.0.3-1取值。表A.0.3-1氣體特性氣體溫度θ(℃)密度ρ(kg/m3)動態(tài)粘度μ[10-5kg導(dǎo)熱系數(shù)λ[10-2W/(m.K)]比熱容c[103J/(kg.K)]空氣-101.3261.6612.3361.00801.2771.7112.416+101.2321.7612.496+201.1891.8112.576氬氣-101.8292.0381.5840.51901.7622.1011.634+101.6992.1641.684+201.6402.2281.734氟化硫-106.8441.3831.1190.61406.6021.4211.197+106.3601.4591.275+206.1181.4971.354氪氣-103.8322.2600.8420.24503.6902.3300.870+103.5602.4000.900+203.4302.4700.9269鍍膜玻璃標(biāo)準(zhǔn)發(fā)射率(εn)取值應(yīng)符合下列規(guī)定:1)應(yīng)在接近正常入射狀況下,采用紅外光譜儀測試玻璃反射曲線;2)在反射曲線上,可按照表A.0.3-2給出的30個波長值,測定相應(yīng)的反射系率Rn(λi);3)283K溫度下的標(biāo)準(zhǔn)反射率應(yīng)按下式計算:(A.0.3-3)4)283K溫度下的標(biāo)準(zhǔn)發(fā)射率應(yīng)按下式計算:(A.0.3-4)表A.0.3-2用于測定283K下標(biāo)準(zhǔn)反射率Rn的波長(單位:μm)序號波長序號波長15.51614.826.71715.637.41816.348.11917.258.62018.169.22119.279.72220.3810.22321.7910.72423.31011.32525.21111.82627.71212.42730.91312.92835.71413.52943.91514.23050.01)2)10校正發(fā)射率ε應(yīng)采用表A.0.3-3給出的系數(shù)乘以標(biāo)準(zhǔn)發(fā)射率(εn)。表A.0.3-3校正發(fā)射率與標(biāo)準(zhǔn)發(fā)射率之間的關(guān)系標(biāo)準(zhǔn)發(fā)射率εn系數(shù)ε/εn0.031.220.051.180.11.140.21.100.31.060.41.030.51.000.60.980.70.960.80.950.890.94注:其它值可以通過線性插值或外推獲得。

附錄B建筑玻璃結(jié)露點(diǎn)計算方法B.0.1室內(nèi)結(jié)露溫度應(yīng)按下列方法確定:1室內(nèi)設(shè)計溫度條件下的飽和水蒸氣壓ps可在表B.0.1中查找。2室內(nèi)設(shè)計溫度條件下的水蒸氣分壓p應(yīng)按室內(nèi)濕度與該溫度下飽和水蒸氣壓ps的乘積取值。3室內(nèi)結(jié)露溫度可按表B.0.1中飽和水蒸氣壓等于水蒸氣分壓p的溫度取值。表B.0.1不同溫度下的飽和水蒸氣壓ps(mmhg)t(oC)pstpsTpstpstps-20-19-18-17-16-15-14-13-12-11-10-9-8-7-6-5-4-3-2-1012345670.7720.8500.9351.0271.1281.2381.3571.6271.7801.9462.1942.3262.5142.7152.9313.1633.4103.6733.9564.2584.5794.9265.2945.6856.1016.5437.0137.5138910111213141516171819202122232425262728293031323334358.0458.6099.2099.84410.5111.2311.9812.7813.6314.5315.4716.4717.5318.6519.8221.0622.3723.7525.2126.7428.3530.0431.8233.7035.6637.7339.9042.183637383940414243444546474849505152535455565758596061626344.5647.0749.6952.4455.3258.3461.5064.8068.2671.8875.6579.6083.7192.5197.20102.1107.2109.7112.5118.0123.8129.8136.1142.6149.4156.4163.8171.464656667686970717273747576777879808182838485868788899091179.3187.5196.1205.0214.2223.7233.7243.9254.6265.7277.2289.1301.4314.1327.3341.0350.7369.7384.9400.6416.8433.6450.9468.7487.1506.1525.8546.19293949596979899100567.0588.6610.9633.9657.6682.1707.3733.2760.0B.0.2玻璃室內(nèi)側(cè)表面溫度應(yīng)按下式計算:(B.0.2)式中:——玻璃室內(nèi)側(cè)表面溫度,K;——建筑物室內(nèi)溫度,K;——建筑物室外溫度,K;——室內(nèi)對流換熱系數(shù),;——玻璃傳熱系數(shù),。B.0.3可按下列方法進(jìn)行玻璃結(jié)露判定:1當(dāng)玻璃室內(nèi)側(cè)表面溫度計算值大于室內(nèi)結(jié)露溫度時,可判定為玻璃不會產(chǎn)生結(jié)露;2當(dāng)玻璃室內(nèi)側(cè)表面溫度計算值小于等于室內(nèi)結(jié)露溫度時,可判定為玻璃會產(chǎn)生結(jié)露。

附錄C玻璃抗風(fēng)壓設(shè)計計算參數(shù)C.0.1單片矩形平板玻璃、、和應(yīng)按表C.0.1取值。表C.0.1單片矩形平板玻璃的抗風(fēng)壓設(shè)計計算參數(shù)t(mm)常數(shù)四邊支撐:b/a兩邊支撐1.001.251.501.752.002.253.005.003k11558.41373.21313.41343.41381.91184.5667.6655.7585.6k20.250.200.2000.300.400.30–0.3000k3–0.6124–0.6071–0.6423–0.7112–0.7642–0.7255–0.4881–0.5000–0.5k44.20–1.40–22.68–12.60–11.202.80–8.40004k12050.71807.51725.71758.91804.61549.8884.0867.8774.9k20.2377120.1901700.1901700.2852540.3803390.285254–0.28525000k3–0.6124–0.6071–0.6423–0.7112–0.7642–0.7255–0.4881–0.5000–0.5k45.70–1.90–30.78–17.10–15.203.80–11.40005k12527.12227.92124.12159.02210.31901.21094.81074.2959.3k20.2283120.1826490.1826490.2739740.3652990.273974–0.27397000k3–0.6124–0.6071–0.6423–0.7112–0.7642–0.7255–0.4881–0.5000–0.5k47.20–2.40–38.88–21.60–19.204.80–14.40006k12990.82637.22511.32546.62602.42241.41301.21276.21139.7k20.2206970.1765580.1765580.2648360.3531150.264836–0.26484000k3–0.6124–0.6071–0.6423–0.7112–0.7642–0.7255–0.4881–0.5000–0.5k48.70–2.90–46.98–26.10–23.205.80–17.40008k13843.73390.23222.33255.63317.72863.41683.31649.91473.4k20.2092950.1674360.1674360.2511540.3348720.251154–0.25115000k3–0.6124–0.6071–0.6423–0.7112–0.7642–0.7255–0.4881–0.5000–0.5k411.55–3.85–62.37–34.65–30.87.7–23.10010k14709.24154.63942.63970.94036.83490.22074.02031.81814.4k20.2000040.1600030.1600030.2400050.3200060.240005–0.24000000k3–0.6124–0.6071–0.6423–0.7112–0.7642–0.7255–0.4881–0.5000–0.5k414.55–4.85–78.57–43.65–38.89.7–29.10012k15548.04895.64639.54660.54728.24094.02455.22404.12146.9k20.1924610.1539690.1539690.2309530.3079370.230953–0.23095000k3–0.6124–0.6071–0.6423–0.7112–0.7642–0.7255–0.4881–0.5000–0.5k417.55–5.85–94.77–52.65–46.8011.70–35.100015k16685.25900.55582.85590.35657.84907.62975.32911.92600.3k20.1838270.1470620.1470620.2205930.2941240.220593–0.22059000k3–0.6124–0.6071–0.6423–0.7112–0.7642–0.7255–0.4881–0.5000–0.5k421.75–7.25–117.45–65.25–58.0014.50–43.500019k18056.17112.36717.86704.56768.05881.73607.13528.23150.6k20.1751270.1401020.1401020.2101520.2802030.210152–0.21015000k3–0.6124–0.6071–0.6423–0.7112–0.7642–0.7255–0.4881–0.500–0.5k427.0–9.0–145.8–81.0–72.018.0–54.00025k110118.28935.88421.58368.28419.27334.64566.24462.93985.3k20.1643980.1315190.1315190.1972780.2630370.197278–0.19728000k3–0.6124–0.6071–0.6423–0.7112–0.7642–0.7255–0.4881–0.5000–0.5k435.25–11.75–190.35–105.75–94.0023.5–70.5000C.0.2單片鋼化玻璃、、和應(yīng)按表C.0.2采用。表C.0.2單片鋼化玻璃的抗風(fēng)壓設(shè)計計算參數(shù)t(mm)常數(shù)四邊支撐:b/a兩邊支撐1.001.251.501.752.002.253.005.004k13594.23152.63108.63374.93634.83012.91382.51372.11225.3k20.5942800.4754240.4754240.7131360.9508480.713136–0.10000000k3–0.6124–0.6071–0.6423–0.7112–0.7642–0.7255–0.4881–0.5000–0.5k45.70–1.90–30.78–17.10–15.203.80–11.40005k14429.23885.93826.24142.54452.03696.01712.31698.51516.8k20.5707800.4566240.4566240.6849350.9132470.684935–0.10000000k3–0.6124–0.6071–0.6423–0.7112–0.7642–0.7255–0.4881–0.5000–0.5k47.20–2.40–38.88–21.60–19.204.80–14.40006k15241.94599.74523.74886.25241.84357.52035.12017.91801.9k20.5517430.4413940.4413940.6620910.8827880.662091–0.10000000k3–0.6124–0.6071–0.6423–0.7112–0.7642–0.7255–0.4881–0.5000–0.5k48.70–2.90–46.98–26.10–23.205.80–17.40008k16736.65913.05804.56246.76682.55566.52632.72608.82329.6k20.5232380.4185900.4185900.6278850.8371800.627885–0.10000000k3–0.6124–0.6071–0.6423–0.7112–0.7642–0.7255–0.4881–0.5000–0.5k411.55–3.85–62.37–34.65–30.807.70–23.100010k18253.77246.37101.97619.18131.16785.13243.83212.62868.8k20.5000100.4000080.4000080.6000120.8000160.600012–0.10000000k3–0.6124–0.6071–0.6423–0.7112–0.7642–0.7255–0.4881–0.5000–0.5k414.55–4.85–78.57–43.65–38.809.70–29.100012k19723.88538.88357.38942.29523.67959.03839.93801.23394.5k20.4811520.3849220.3849220.5773820.7698430.577382–0.10000000k3–0.6124–0.6071–0.6423–0.7112–0.7642–0.7255–0.4881–0.5000–0.5k417.55–5.85–94.77–52.65–46.8011.70–35.100015k111716.910291.510056.510726.311396.09540.74653.44604.14111.4k20.4595680.3676550.3676550.5514820.7353090.551482–0.10000000k3–0.6124–0.6071–0.6423–0.7112–0.7642–0.7255–0.4881–0.5000–0.5k421.75–7.25–117.45–65.25–58.0014.50–43.500019k114119.612405.012101.112864.113632.211434.25641.55578.54981.6k20.4378170.3502540.3502540.5253810.7005080.525381–0.10000000k3–0.6124–0.6071–0.6423–0.7112–0.7642–0.7255–0.4881–0.5000–0.5k427.0–9.0–145.8–81.0–72.018.0–54.00025k117733.915585.715170.016056.416958.214258.87141.57

溫馨提示

  • 1. 本站所有資源如無特殊說明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請下載最新的WinRAR軟件解壓。
  • 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請聯(lián)系上傳者。文件的所有權(quán)益歸上傳用戶所有。
  • 3. 本站RAR壓縮包中若帶圖紙,網(wǎng)頁內(nèi)容里面會有圖紙預(yù)覽,若沒有圖紙預(yù)覽就沒有圖紙。
  • 4. 未經(jīng)權(quán)益所有人同意不得將文件中的內(nèi)容挪作商業(yè)或盈利用途。
  • 5. 人人文庫網(wǎng)僅提供信息存儲空間,僅對用戶上傳內(nèi)容的表現(xiàn)方式做保護(hù)處理,對用戶上傳分享的文檔內(nèi)容本身不做任何修改或編輯,并不能對任何下載內(nèi)容負(fù)責(zé)。
  • 6. 下載文件中如有侵權(quán)或不適當(dāng)內(nèi)容,請與我們聯(lián)系,我們立即糾正。
  • 7. 本站不保證下載資源的準(zhǔn)確性、安全性和完整性, 同時也不承擔(dān)用戶因使用這些下載資源對自己和他人造成任何形式的傷害或損失。

評論

0/150

提交評論