1、1tool Basic Course,Trainees:,Trainer: Paolo Zama,1tool basic training course,Welcome!,To give the basic knowledge on: Development tool (1tool) Programming languages Project management through a series of exercises. += At the end of the training you will have made a simple application for a simple ai
2、r conditioning unit. No details regarding: hardware, wiring, commercial.,Course targets 1/2,1tool keypoints (movie) Setup Licence management (SW/HW) How to create, edit, test, upload a project into a pCOOverview of 1tool components Special functionsOverview of special functions: virtual keys, alarms
3、, define the key function, etc. How to exchange variables with other pCO controllerspLAN network How to exchange variables with a generic BMS systemSupervisory system network How to test/configure the appl. online via Commissioning tool How to migrate an EasyTools project How to get supporte-mail, w
4、eb site,Course targets 2/2,If the explanation is not clear or if you have questions or curiosity feel free to ask If the exercise is unclear, ask immediately to repeat Dont use objects or concepts that were not explained (you will be told what to use) Dont read the manual unless you are asked to do
5、so Dont make more than you are asked to do,Rules,?,?,HE LP,? ?,?,pCO3,pCO1,pCOC,pCOXS,PGD0Semi-Graphic,PGD3Graphic/TouchScreen,Ambiente di programmazione per tutti i controllori/terminali programmabili della linea pCO sistema,1tool,pCO2,Supernode,PGD1Semi-Graphic,Schedule:09:00 12:30 (coffee break a
6、t mid-morning)12:30 13:30 Lunch buffet in CAREL13:30 18:00 (coffee break at mid-afternoon)Dinner: see list of restaurants What is departure time? (last day) Taxi booking needed? Wi-Fi zone (b/g). Ask at Reception.Passaporto / Identity card required.(no VPN),Miscellaneous information,How to create a
7、new Solution/Project (SolutionExplorer)Overview of editors How to define the control strategy (StrategyEditor) How to define the user interface (MaskEditor) How to compile How to simulate (Simulator) How to upload the application into the controller (pCOLOAD),Topics 1/6,Topics 2/6,How to create a pa
8、rameter (e.g. Setpoint)Permanent memory (T), default values, DEV file How to create a new mask How to define the function of a key (KeyFunctionEditor) How to create a Loop of masks How to enable a mask (EnableOn property) Levels: Field, Mask, Global.Text association (ResourceUsedOnBool/Int)Objects p
9、roperties “move” field: allows to show the previous/next mask,Some macroblocks: GE, GT, LE, LT, GradCmp, Limit, Limit_Low, Limit_High How to manage the Unit Status (if statement) System variables (KEY_COUNTER) Virtual key How to create a new StrategyPage Standard management of alarmsMacroblocks Hyst
10、_Dir_Set2Diff, Hyst_Rev_Set2Diff, Hyst_Dir_OnOff, Hyst_Rev_OnOff. Alarm mask: Alarm Status / Alarm memory System variables: BUZZER, GLOBAL_ALARM, RESET_BUZZER, RESET_ALARM,Topics 3/6,How to backup a Solution: just copy the Solution folder How to specialize a mask (without the “move” field) How to sh
11、ow a special character (Example “”) Time management: system variables CURRENT_HOUR, NEW_HOUR, SET_HOURField code, macroblock Schedule_Daily BlockExecutionOrder (Reference):Main cycle, events (Do_Task atom/statement) Unconnected pin (autoconnection of Const/Var),Topics 4/6,How to create a macroblock
12、How to create a module Module mask insertion mode: Linked, Imported, StrategyOnly pLAN (pCO LAN) Each controller can show its masks into up to 3 terminals (SHared, PRivate) Send variables among controllers (max 2048 links) How to configure the pLAN (addresses, terminal config.) BMS: how to send/rece
13、ive variables Commissioning tool How to migrate an EasyTools project (Migration Wizard),Topics 5/6,File system (Binary files folder) Content of FLASH memory:BOOT, BIOS, IUP, BLB/BIN, DEV Next steps Starter kit 1tool support service: ,Topics 6/6,Start Windows (Supported: XPpro, Vista)Login as “Admini
14、strator” Insert the 1tool DVD-ROMOpen D:INDEX.HTM Click English, Setup 1tool, First installation Click 1tool_prerequisites_setup.exeSelect “Run”. Accept all proposal. Click 1tool_setup.exeSelect “Run”. Accept all proposal. Start 1tool: Start/Programs/Carel/1tool/1tool,Setup,Solution Explorer New pro
15、jects, start editors, add languages, Strategy EditorControl strategy Mask EditorUser interface (content of masks, keys function) Network EditorpLAN projects (selection of units/projects, definition of links among units) SimulatorSimulation on the PC pCO Manager (pCO Load + Commissioning tool)Upload
16、of application files into the controller, definition of Logs, commissioning/test functions Migration WizardConversion of EasyTools projects to 1tool project.,1tool components/editors,Create a new solution/project,Project life cycle,Edit Control strategy (Strategy Editor),Edit User interface (Mask Ed
17、itor),Compile,Debug/Simulate (Simulator),Upload (pCOLOAD),Backup,Edit Network (Network Editor),Upload,2.Compile the project successfully, then click the button (pCO Manager),4. Select the folder where application files are saved,5. Select files to be uploaded to the device,3. Set the pCO address and
18、 PortNumber of your converter, and click button “Connect” in the toolbar.,6. Upload and Checking progress,1.Connect PC to device using the USB/RS485 converter,Analog pin Integer pin,Data Type (main types),emory Type (main types),Variables,NOTE: all atoms write in “X-Ram” memory, except RA_IN_T / RI_
19、IN_T / RD_IN_T, Move_BT_En, Move_IT_En. “T-Permanent” memory has a limited number of write-cycles (10.000.000),Decimal/Real/Float datatype/values are not supported.Analog is an Integer but values are shown with “.” (21.5 = 215)Analog and Integer are compatible.,Unconnected pin,If the pin was unconne
20、cted: Input pins will take the default value as the pin was connected to a constant Output pins will take a temporary variable automatically.,Not all pins can be left unconnected. Example: the atoms Jump_Start and Jump_End, Array_Read, etc. You can select the behavior in case of unconnected pin:Comp
21、ile/Compiling options,They are equivalent,Loop of masks,A loop of masks is a group of masks. If the cursor is in the top-left corner (in the “move” field), the UP/DOWN keysshow the PREVIOUS/NEXT (enabled) maskof the loop. UP/DOWN keys change mask thanks to the “move” field The “move” field is automa
22、tically added to the new masks.If not needed just delete it.To restore it, just copy it from another mask. Loop object is optional Goto_loop(); statementCorresponds to Goto_mask(first mask of the loop);,Level: Field, Mask, Global,The level is shown in the Key Function Editor The level is the same fo
23、rthe Key Function Editor and Property,Field code (highest priority) Mask code Global code (lowest priority),(Field),(Mask),(Global),How to create a virtual key: Create a variables that assumes the value 1 when the virtual key has to be pressed Create a new key and link it with the variable(Unused Ke
24、ycode: 137-179, 200-254) Defines the function of the new virtual key,Virtual keys,Exercise: Show the main mask after 60s of inactivity of the keyboard,Normally a KEY statement is executedwhen a physical key (switch) is pressed . Sometimes is necessary to execute a key according tothe value of a vari
25、ables: its necessary a virtual key. The virtual key is pressed when the variables changes from 0 to 1.,Alarm management (1/2),Built-in standard management of alarms provides: to switch the buzzer ON as soon as an alarm starts (Alarm status 01) to manage the alarm memory variable (Alarm memory) a set
26、 of system variables:,1tool provides a set of system variables for turning the buzzer ON/OFF (MAN_BUZZER_EN, MAN_BUZZER_ON, MAN_BUZZER_OFF),This feature is performed through: Alarm masks Properties,Mask enable: ALARM mask: variable AlarmMemory (mAL) NORMAL mask:variabile EnableOn,Alarm management (2
27、/2) .,When the ALARM key is pressed:,if(SysVarList.GLOBAL_ALARM=0) Goto_mask(No_Alarms); if(SysVarList.GLOBAL_ALARM=1) ,Block Execution Order,Note : You cant place two blocks with the same number in the same page. You can use Jump_Start and Jump_End blocks to skipsome blocks during the execution.,Th
28、e page order is depend on its position in the Solution Explorer. They are executed from the top to the bottom.,You can change Block Execution Order by double-click the block or by right-click the page background,Define the Block Execution Order of the current page. Blocks are executed according to t
29、he numerical value in turn.,You can change the page order by right-click the page, then select the “Change page order”,How to create a macroblock: Create a New project, Module/Macroblock type Delete Terminal node (macroblocks dont contain mask) Define Strategy Create the pins (select Block pin prope
30、rty) Define the shape using the Shape editor Save the block into library using the context menu “Save to library As”,Macroblocks,How to open a macroblock/module: Context menu Open block,Help: Select block, Context menu “?”,Type of blocks: Block “Atom” Block “Macroblock” (only strategy) Block “Module
31、” (strategy+masks),Modules (1/2),Types of blocks: Block “Atom” Block “Macroblock” (only strategy) Block “Module” (strategy+masks) Mask insertion mode: Linked:- The masks mantain the link with the instance of the block.- If the block is deleted its masks are deleted too- It is possible only to add TE
32、XT/IMAGES/ANIM/LINE/RECT, move masks Imported: - The masks are imported and become project masks- It is possible to do any kind of modification Strategy only:- The mask are not inserted Modules have a LABEL (example EVD400_CIRC1) Variables, SpecialFields, TouchSchemas, etc are renamed (Example: Fan_
33、1 Set) The application has the access to module variables: LABEL.VarNameOnly for pin not “Visible in shape”,Modules (2/2),The module can be designed for several types of displays and languages,The masks are inserted in the original loop according to the property “MaskDefaultPosition”:Default, First
34、mask, Last mask Autoconnection NOTE A module cant contain modules (with masks) but only atoms/macroblocks. The masks are ignored. A module cant contain GlobalCode/Events,Project,Module,Important! BMS and the pLAN network are independent networks The purpose of the BMS network is to exchange variable
35、s with a supervisory system/BMS (PlantVisor, pCOWeb, WebGate, Gateway, Modem, Lon, Trend, DLL etc.) How to send/receive variables (common for all types of architectures) Address in the network (system variable BMS_ADDRESS (I,T) ) Communication speed (system variable COM_BAUDRATE_BMS (I,X) ) Communic
36、ation protocol (system variable COM_PROTOCOL_BMS (I,X) ) Select variables. 2 alternatives: Variable properties, BMS property (BIOS =4.29 required) Remote atoms RD_In_T, RI_In_T, RA_In_T (variables in “T” memory) RD_In_X, RI_In_X, RA_In_X (variables in”X” memory) RD_Out, RI_Out, RA_Out (variables in
37、“T” and “X” memory) RD_Multiser, RI_Multiser, RA_Multiser CAREL protocol: Max 207 variables for each type (A, I ,D).MODBUS protocol: max 10000 registers / 2048 coils Communication test programs:CAREL protocol, SLAVE side: DTEST (CAREL)MODBUS protocol, SLAVE side: MODSCAN,Supervisory system network (
38、BMS),Connectivity (pCO3),Point-to-Point (stand-alone) (obsolete) Only 1 controller (with or without built-in terminal)Address must be 0 Only 1 optional external terminal (always Private)Address must be 0,Controllers architectures,pLAN (pCO LAN) Up to 31 controllers (with or without built-in terminal
39、)Address must NOT be 0 (1-31) Up to 31 optional external terminals (Private o Shared) Address must NOT be 0 (1-32),PGD display works in Text display compatibility mode:1 fixed font (CAREL_TERM), 4rows/20columns, only single-height rows, no images,PGD display fully working:3 fonts, 4x20(PGD0) or 8x22
40、 (PGD1) rows/columns, double-height rows, images,pLAN units,Max 32 units (only terminals can have address=32) Any combination is allowed,pCO3/2,pCO1,pCOXS,pCOC,LCD4x20,PGD0/1,PGD2/3,ARIA/PAD,FCM,EVD Electronic Expansion Valve Driver,Supernode,The BMS and the pLAN network are independent networks Fea
41、tures of the pLAN network: Each controller can show its masks into up to 3 terminals(Private or Shared)+builtin Send variables among controllers (max.2048 outgoing links for each controller) pLAN devices Any type of pCO, TXT/PGD terminals, Aria/pAD, EVD, FCM Any combination is allowed Max 32 units (
42、only terminals can have address=32) NetworkEditor Insert in one or more NetworkPage the controllers, terminals, parametric pLAN Define address and project define links using pLAN Table The variables used in a link must have the “pLAN” flag checked Setup pLAN,pLAN network (1/2),Compile and Upload app
43、lication files into pCO Set pLAN address to pLAN devices Connect pLAN devices (Wiring) Configure terminal,Terminal configuration System mask (press UP+DOWN+ENTER for 5sec) System variables PLAN_TERM_CONF* NetworkEditor (Terminal property, Setup button) (Default configuration) The value of the variable is sent everytime it changes and as soon as the communication startsNOTE: variable form X to T are not sent at startup pLAN alarms management pLAN system variables (most important) PLAN_ADDRESS: pCO address PLAN_
溫馨提示
- 1. 本站所有資源如無特殊說明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請(qǐng)下載最新的WinRAR軟件解壓。
- 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請(qǐng)聯(lián)系上傳者。文件的所有權(quán)益歸上傳用戶所有。
- 3. 本站RAR壓縮包中若帶圖紙,網(wǎng)頁內(nèi)容里面會(huì)有圖紙預(yù)覽,若沒有圖紙預(yù)覽就沒有圖紙。
- 4. 未經(jīng)權(quán)益所有人同意不得將文件中的內(nèi)容挪作商業(yè)或盈利用途。
- 5. 人人文庫網(wǎng)僅提供信息存儲(chǔ)空間,僅對(duì)用戶上傳內(nèi)容的表現(xiàn)方式做保護(hù)處理,對(duì)用戶上傳分享的文檔內(nèi)容本身不做任何修改或編輯,并不能對(duì)任何下載內(nèi)容負(fù)責(zé)。
- 6. 下載文件中如有侵權(quán)或不適當(dāng)內(nèi)容,請(qǐng)與我們聯(lián)系,我們立即糾正。
- 7. 本站不保證下載資源的準(zhǔn)確性、安全性和完整性, 同時(shí)也不承擔(dān)用戶因使用這些下載資源對(duì)自己和他人造成任何形式的傷害或損失。
最新文檔
- 2025年大學(xué)心理學(xué)(心理學(xué)基礎(chǔ))試題及答案
- 2025年大學(xué)經(jīng)濟(jì)法(經(jīng)濟(jì)法)試題及答案
- 2025年大二(社會(huì)體育指導(dǎo)與管理)運(yùn)動(dòng)生理學(xué)期末試題
- 2025年中職會(huì)計(jì)(會(huì)計(jì)法規(guī)基礎(chǔ))試題及答案
- 2025年高職市政工程技術(shù)(城市道路工程施工)試題及答案
- 2025年中職(包裝產(chǎn)品銷售)防護(hù)功能階段測試卷
- 2025年高職數(shù)字媒體藝術(shù)設(shè)計(jì)(媒體應(yīng)用)試題及答案
- 2025年中職機(jī)電(機(jī)電基礎(chǔ)應(yīng)用)試題及答案
- 2025年大學(xué)大三(預(yù)防醫(yī)學(xué))健康教育與促進(jìn)試題及答案
- 2025年大學(xué)護(hù)理學(xué)(老年護(hù)理實(shí)訓(xùn))試題及答案
- 新疆開放大學(xué)2025年春《建筑構(gòu)造實(shí)訓(xùn)》形考作業(yè)【標(biāo)準(zhǔn)答案】
- 2025年湖南水利水電職業(yè)技術(shù)學(xué)院單招職業(yè)技能測試題庫附答案
- 建設(shè)工程質(zhì)量管理手冊(cè)范本
- 醫(yī)院申請(qǐng)醫(yī)養(yǎng)結(jié)合申請(qǐng)書
- 2024-2025學(xué)年山東省濱州市北鎮(zhèn)中學(xué)鴻蒙班九年級(jí)下學(xué)寒假開學(xué)考試數(shù)學(xué)試題
- 園林綠化服務(wù)方案(3篇)
- 2025年流產(chǎn)家屬簽字協(xié)議書
- 2025年《中醫(yī)護(hù)理適宜技術(shù)臨床應(yīng)用指南》
- 下頜阻生齒拔除病例匯報(bào)
- DBJ04-T 491-2025 建設(shè)工程消防設(shè)計(jì)審查驗(yàn)收文件歸檔標(biāo)準(zhǔn)
- DB45∕T 2419-2021 鉆孔管波探測技術(shù)規(guī)程
評(píng)論
0/150
提交評(píng)論