1、All content in this presentation is protected 2008 American Power Conversion CorporationAPC機(jī)房監(jiān)控管理系統(tǒng)機(jī)房監(jiān)控管理系統(tǒng)用戶培訓(xùn)用戶培訓(xùn)APC by Schneider Electric Name Date 目錄系統(tǒng)概述系統(tǒng)結(jié)構(gòu)監(jiān)控對象監(jiān)控內(nèi)容監(jiān)控系統(tǒng)-硬件監(jiān)控系統(tǒng)-軟件系統(tǒng)使用系統(tǒng)維護(hù)APC by Schneider Electric Name Date 系統(tǒng)概述 采用APC ISX Central管理長春一汽大眾的主機(jī)房和備份機(jī)房的所有UPS、空調(diào)、配電、溫濕度、漏水、視頻等。其設(shè)備與監(jiān)控服務(wù)器(
2、APC ISX Central)建立網(wǎng)絡(luò)連接。當(dāng)在ISX Central系統(tǒng)上添加被管理設(shè)備IP地址后,就可以實(shí)時(shí)采集被管理設(shè)備的運(yùn)行狀態(tài),當(dāng)被管理設(shè)備出現(xiàn)異常時(shí),可通過郵件和短信通知機(jī)房管理員;可通過客戶端軟件登到ISX Central系統(tǒng)上瀏覽,當(dāng)客戶端軟件在線時(shí),設(shè)備出現(xiàn)故障時(shí)有語音告警。APC by Schneider Electric Name Date 系統(tǒng)結(jié)構(gòu) FAW-VW LAN(168)備份機(jī)房(UPS/PDU/AC/TH/CM)主機(jī)房(UPS/PDU/AC/TH/CM)APC ISX CentralClient & SMS APC by Schneider Elec
3、tric Name Date 主機(jī)房系統(tǒng)拓?fù)鋱DFAW-VW LAN(168.168.18.5590)APC ICUPS2*SYPX配電柜6*PDU空調(diào)4*Liebert5*CANATAL1*StulzNB監(jiān)控基站3*NB550(12*T/H,3*Leak)攝像頭12* PecloAPC by Schneider Electric Name Date 備份機(jī)房系統(tǒng)拓?fù)鋱DFAW-VW LAN(168.168.18.91-104)APC ICUPS2*SYPX配電柜2*PDU空調(diào)2* RCNB監(jiān)控基站2*NB550(6*T/H,1*Leak)攝像頭6* PecloAPC by Schneider E
4、lectric Name Date 監(jiān)控對象-主機(jī)房 UPS1 (APC SYPX500)和UPS 2 (APC SYPX500) 地下UPS間 配電柜 6臺(APC ISX模塊化PDU)主機(jī)房A區(qū)1列,2列;C區(qū)5,6,7,8列 空調(diào)-10臺(1號空調(diào),Liebert LDS,網(wǎng)絡(luò)機(jī)房), (2號空調(diào),Liebert LDS,主機(jī)房B區(qū)), (3號空調(diào),Liebert LDS,主機(jī)房B區(qū)), (4號空調(diào),CANATAL 9S,主機(jī)房B區(qū)), (5號空調(diào),CANATAL 9S,主機(jī)房D區(qū)), (6號空調(diào),Liebert LDS,主機(jī)房D區(qū)), (7號空調(diào),CANATAL 9S,主機(jī)房D區(qū)),
5、(8號空調(diào),CANATAL 9S,主機(jī)房檔案資料室), (9號空調(diào),CANATAL 9S,主機(jī)房A區(qū)), (10號空調(diào),Stulz CSD602A,地下UPS間), NB550 3臺(10個(gè)溫濕度在主機(jī)房,1個(gè)在網(wǎng)絡(luò)機(jī)房,1個(gè)在地下UPS間;三個(gè)漏水,主機(jī)房B區(qū)一根,主機(jī)房D區(qū)一根,9號空調(diào)下面一根) Pelco網(wǎng)絡(luò)攝像頭12個(gè)( 10個(gè)溫濕度在主機(jī)房,1個(gè)在網(wǎng)絡(luò)機(jī)房,1個(gè)在地下UPS間)APC by Schneider Electric Name Date 主機(jī)房-設(shè)備分布-配電柜#1配電柜 #2配電柜#3配電柜#4配電柜#5配電柜#6配電柜APC by Schneider Electric
6、 Name Date 主機(jī)房-設(shè)備分布-空調(diào)#1空調(diào)#2空調(diào) #3空調(diào) #4空調(diào)#5空調(diào) #6空調(diào) #7空調(diào)#8空調(diào)#9空調(diào)APC by Schneider Electric Name Date 主機(jī)房-設(shè)備分布-溫濕度T/H 1-1 T/H 1-3T/H 1-2T/H 1-4T/H 1-5T/H 1-6T/H 2-1T/H 2-2T/H 2-3T/H 2-4T/H 2-5APC by Schneider Electric Name Date 主機(jī)房-設(shè)備分布-漏水#1漏水#2漏水#3漏水NB550APC by Schneider Electric Name Date 主機(jī)房-設(shè)備分布-攝像頭
7、#1#2#3#4#5#6#7#11#8#9#10APC by Schneider Electric Name Date 主機(jī)房設(shè)備分布-UPS間#10空調(diào)#12#12T/H#4漏水APC by Schneider Electric Name Date 監(jiān)控對象-備份機(jī)房 UPS1 (APC SYPX250)和UPS 2 (APC SYPX250) 電源間配電柜 2臺(APC ISX模塊化PDU)備份機(jī)房第三列兩頭空調(diào)-2臺(11號空調(diào),RC PEGASUS,備份機(jī)房),12號空調(diào),RC PEGASUS,備份機(jī)房),NB550 2臺(5個(gè)溫濕度在備份機(jī)房,1個(gè)在UPS間;一個(gè)漏水,11號與12號
8、空調(diào)下面一根)Pelco網(wǎng)絡(luò)攝像頭6個(gè)( 5個(gè)溫濕度在備份機(jī)房,1個(gè)在UPS間)APC by Schneider Electric Name Date 備份機(jī)房-設(shè)備分布#12空調(diào)#11空調(diào)漏水#1配電柜#2配電柜#1 T/H#2 T/H#3 T/H#4 T/H#5 T/H#6 T/H#1#2#3#4#5#6NB550APC by Schneider Electric Name Date 監(jiān)控內(nèi)容-UPSUPS工作狀態(tài)、開關(guān)狀態(tài)UPS輸入電壓、電流、頻率UPS輸出電壓、電流、頻率、功率,負(fù)載率等UPS旁路電壓、電流、頻率UPS電池狀態(tài)及其參數(shù),如,電壓、電流、電量、溫度、后備時(shí)間等APC by
9、 Schneider Electric Name Date 監(jiān)控內(nèi)容-配電柜配電柜工作狀態(tài)、各模塊工作狀態(tài)、告警狀態(tài)各配電模塊輸出參數(shù)電流、功率和負(fù)載率配電系統(tǒng)輸出參數(shù),電壓、頻率APC by Schneider Electric Name Date 監(jiān)控內(nèi)容-空調(diào)回風(fēng)溫濕度通訊狀態(tài)開關(guān)機(jī)狀態(tài)綜合告警狀態(tài)APC by Schneider Electric Name Date 監(jiān)控內(nèi)容-溫濕度監(jiān)測機(jī)房溫濕度探頭所在位置的實(shí)時(shí)溫濕度值高溫告警APC by Schneider Electric Name Date 監(jiān)控內(nèi)容-漏水檢測機(jī)房各空調(diào)漏水情況APC by Schneider Electric
10、 Name Date 監(jiān)控內(nèi)容-攝像頭監(jiān)視所在區(qū)域的人員活動情況APC by Schneider Electric Name Date 監(jiān)控系統(tǒng)-硬件APC ISX Central(機(jī)房動力環(huán)境集中監(jiān)控服務(wù)器) NB550環(huán)境監(jiān)控基站 UPS網(wǎng)卡PDU網(wǎng)卡空調(diào)網(wǎng)卡溫濕度探頭漏水檢測繩網(wǎng)絡(luò)交換機(jī)網(wǎng)絡(luò)攝像頭短信告警系統(tǒng)APC by Schneider Electric Name Date 監(jiān)控系統(tǒng)-硬件- APC ISX Central(機(jī)房動力環(huán)境集中監(jiān)控服務(wù)器) 集中監(jiān)控系統(tǒng)內(nèi)嵌數(shù)據(jù)庫Linux系統(tǒng)Web訪問雙網(wǎng)卡(192.168.1.1/168.168.18.55)默認(rèn)用戶名密碼(apc)A
11、PC by Schneider Electric Name Date 監(jiān)控系統(tǒng)-軟件集中監(jiān)控軟件NB550監(jiān)控軟件網(wǎng)卡界面(UPS、配電、空調(diào)等)網(wǎng)絡(luò)攝像頭短信告警APC by Schneider Electric Name Date 集中監(jiān)控軟件APC by Schneider Electric Name Date NB550界面APC by Schneider Electric Name Date UPS網(wǎng)卡界面APC by Schneider Electric Name Date 配電柜網(wǎng)卡界面APC by Schneider Electric Name Date 空調(diào)網(wǎng)卡界面APC b
12、y Schneider Electric Name Date Pelco網(wǎng)絡(luò)攝像頭APC by Schneider Electric Name Date 短信告警系統(tǒng)界面APC by Schneider Electric Name Date 軟件使用打開IE,登錄集中監(jiān)控服務(wù)器的IP,192.168.1.1或168.168.18.55第一次需要下載客戶端軟件并安裝啟動客戶端軟件,輸入用戶名密碼:apc點(diǎn)擊監(jiān)控-進(jìn)入設(shè)備組-選擇機(jī)房名稱點(diǎn)擊右邊的映像視圖-機(jī)房設(shè)備布局及其運(yùn)行情況一旦有告警,圖標(biāo)會變紅,用鼠標(biāo)移動此位置可顯示具體哪個(gè)參數(shù)告警下方的當(dāng)前警報(bào)那里也將顯示出具體告警信息,同時(shí)有語音提示
13、點(diǎn)擊監(jiān)視-設(shè)備組-選擇機(jī)房,選擇右邊的縮微圖,顯示該機(jī)房里的所有攝像頭監(jiān)視界面可導(dǎo)出某個(gè)設(shè)備的某個(gè)具體參數(shù)的運(yùn)行數(shù)據(jù)曲線和日志報(bào)告可導(dǎo)出某個(gè)設(shè)備的具體歷史告警報(bào)告APC by Schneider Electric Name Date 查看設(shè)備運(yùn)行參數(shù)APC by Schneider Electric Name Date 導(dǎo)出數(shù)據(jù)圖形和報(bào)告APC by Schneider Electric Name Date 生成的圖形和報(bào)告APC by Schneider Electric Name Date 導(dǎo)出設(shè)備歷史告警信息APC by Schneider Electric Name Date 系統(tǒng)維護(hù)
14、修改這些設(shè)備的默認(rèn)用戶名密碼修改接收短信的手機(jī)號定期查一下手機(jī)卡是否余額不足定期登錄這些設(shè)備的網(wǎng)卡界面看具體的事件日志網(wǎng)絡(luò)中斷,檢查網(wǎng)線和接頭設(shè)備停電重啟,重新登錄系統(tǒng)短信通知不能收到,請檢查短信模塊是否有電,手機(jī)卡是否是沒錢了?遇到告警,可以先進(jìn)一步登錄具體設(shè)備的網(wǎng)頁界面看看,然后再到具體設(shè)備跟前親自檢查,確認(rèn)告警情況如,UPS設(shè)備告警或空調(diào)告警,可以致電UPS廠家或空調(diào)廠家如高溫告警,請檢查附近的空調(diào)是否正常制冷?如配電柜告警,請檢查所供機(jī)柜里設(shè)備是否用電超負(fù)荷?如空調(diào)漏水,請檢查附近空調(diào)下方是否有漏水?APC by Schneider Electric Name Date 系統(tǒng)維護(hù)主要關(guān)注UPS和配電,以及空調(diào)等告警UPS IP:168.168.18.56-57 168.168.18.91-92空調(diào)IP:168.168.18.64-73 168.168.18.95-96配電柜: 1
溫馨提示
- 1. 本站所有資源如無特殊說明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請下載最新的WinRAR軟件解壓。
- 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請聯(lián)系上傳者。文件的所有權(quán)益歸上傳用戶所有。
- 3. 本站RAR壓縮包中若帶圖紙,網(wǎng)頁內(nèi)容里面會有圖紙預(yù)覽,若沒有圖紙預(yù)覽就沒有圖紙。
- 4. 未經(jīng)權(quán)益所有人同意不得將文件中的內(nèi)容挪作商業(yè)或盈利用途。
- 5. 人人文庫網(wǎng)僅提供信息存儲空間,僅對用戶上傳內(nèi)容的表現(xiàn)方式做保護(hù)處理,對用戶上傳分享的文檔內(nèi)容本身不做任何修改或編輯,并不能對任何下載內(nèi)容負(fù)責(zé)。
- 6. 下載文件中如有侵權(quán)或不適當(dāng)內(nèi)容,請與我們聯(lián)系,我們立即糾正。
- 7. 本站不保證下載資源的準(zhǔn)確性、安全性和完整性, 同時(shí)也不承擔(dān)用戶因使用這些下載資源對自己和他人造成任何形式的傷害或損失。
最新文檔
- 2025年信息安全意識培訓(xùn)與宣傳手冊
- 財(cái)務(wù)報(bào)銷及審核制度
- 辦公室員工培訓(xùn)記錄與檔案制度
- 辦公室保密文件查閱與審批制度
- 2026年燈湖第三小學(xué)面向社會招聘語文、數(shù)學(xué)臨聘教師備考題庫及1套參考答案詳解
- 2026年西安交通大學(xué)電信學(xué)部管理輔助人員招聘備考題庫及1套參考答案詳解
- 2026年湖南蓉園集團(tuán)有限公司公開招聘備考題庫含答案詳解
- 2026年江西興宜全過程項(xiàng)目咨詢有限公司招聘造價(jià)工程師備考題庫完整參考答案詳解
- 中國東方航空技術(shù)有限公司2026招聘備考題庫帶答案詳解
- 2026年鎮(zhèn)康縣騰勢口岸經(jīng)營管理有限公司行政管理崗招聘備考題庫及參考答案詳解
- GB/T 46758-2025紙漿硫酸鹽法蒸煮液總堿、活性堿和有效堿的測定(電位滴定法)
- 2026屆福建省龍巖市龍巖一中生物高一第一學(xué)期期末綜合測試試題含解析
- 二元思辨:向外探索(外)與向內(nèi)審視(內(nèi))-2026年高考語文二元思辨作文寫作全面指導(dǎo)
- 智能清掃機(jī)器人設(shè)計(jì)與研發(fā)方案
- 《中華人民共和國危險(xiǎn)化學(xué)品安全法》全套解讀
- 糖尿病足護(hù)理指導(dǎo)
- 甲狀腺腫瘤的課件
- 新型鋁合金雨棚施工方案
- 2025年國家開放大學(xué)《社會調(diào)查研究方法》期末考試復(fù)習(xí)試題及答案解析
- 《數(shù)字經(jīng)濟(jì)概論》全套教學(xué)課件
- 風(fēng)險(xiǎn)管理與內(nèi)部控制-全套課件
評論
0/150
提交評論