(標準規(guī)范)美國規(guī)范:Seismic Provisions for Structural Steel Buildings Supplement-2000_第1頁
(標準規(guī)范)美國規(guī)范:Seismic Provisions for Structural Steel Buildings Supplement-2000_第2頁
(標準規(guī)范)美國規(guī)范:Seismic Provisions for Structural Steel Buildings Supplement-2000_第3頁
(標準規(guī)范)美國規(guī)范:Seismic Provisions for Structural Steel Buildings Supplement-2000_第4頁
(標準規(guī)范)美國規(guī)范:Seismic Provisions for Structural Steel Buildings Supplement-2000_第5頁
已閱讀5頁,還剩30頁未讀 繼續(xù)免費閱讀

下載本文檔

版權(quán)說明:本文檔由用戶提供并上傳,收益歸屬內(nèi)容提供方,若內(nèi)容存在侵權(quán),請進行舉報或認領(lǐng)

文檔簡介

SeismicProvisionsforStructural

SteelBuildings(1997)

SupplementNo.2

November10,2000

SupersedesSupplementNo.1totheAISCSeismicProvisionsforStructuralSteelBuildings,datedFebruary15,1999

PreparedbytheAmericanInstituteofSteelConstruction,Inc.underthedirectionoftheAISCCommitteeonSpecificationsand

approvedbytheAISCBoardofDirectors

AMERICANINSTITUTEOFSTEELCONSTRUCTION,INC.

OneEastWackerDrive,Suite3100,Chicago,Illinois60601-2001

PAGE

10

AISCSeismicProvisions(1997)SupplementNo.2(11/00)

AISCSeismicProvisions(1997)SupplementNo.2(11/00)

PAGE

11

AMERICANINSTITUTEOFSTEELCONSTRUCTION

AMERICANINSTITUTEOFSTEELCONSTRUCTION

SeismicProvisionsforStructural

SteelBuildings(1997)

SupplementNo.2

November10,2000

PartI,Glossary

DeletethedefinitionofInelasticRotationofBeam-to-ColumnConnection.

Addthefollowingdefinitions:

“InterstoryDriftAngle.Interstorydisplacementdividedbystoryheight,radians.

ZipperColumn.Avertical(ornearlyvertical)strutconnectingthebrace-to-beamintersectionofaninverted-V-bracedframeatoneleveltothebrace-to-beamintersectionatanotherlevel.SeeFigureC-13.4(b).”

ChangedefinitionofReducedBeamSectionasfollows:

“Aductilereductionincross-section...<remainderunchanged>”

PartI,Section2

Changethissectionasfollows:

...

AmericanSocietyofCivilEngineersASCE7-9598

AmericanSocietyforTestingandMaterials

ASTMA6-96b98

ASTMA500-9399

ASTMA673-95

ASTMA36-9697a

ASTMA501-9399

ASTMA913-95a97

ASTMA53-9699b

ASTMA572-94c99

ASTMA992-98

ASTMA283-93a

ASTMA588-9497a

AmericanWeldingSocietyAWSD1.1-96D1.1:2000

….

PartI,Section6.1

AddASTMA992tothelistofmaterialspecificationsthatareapprovedforuseintheSeismicForceResistingSystem.

PartI,Section6.2

Changethissectionasfollows:

“WhenrequiredintheseProvisions,therequiredstrengthofaconnectionorrelatedmembershallbedeterminedfromtheExpectedYieldStrengthFyeoftheconnectedmember,where

Fye=RyFy (6-1)

Fyisthespecifiedminimumyieldstrengthofthegradeofsteeltobeused.Forrolledshapesandbars,RyshallbeasshowninTableI-6-1takenas1.5forASTMA36and1.3forA572Grade42.Forrolledshapesandbarsofothergradesofsteelandforplates,Ryshallbetakenas1.1.OthervaluesofRyarepermittedtobeusedifthevalueofFyeisdeterminedbytestingthatisconductedinaccordancewiththerequirementsforthespecifiedgradeofsteel.

TABLEI-6-1

RyValuesforDifferentMemberTypes

Application

Ry

Platesandallotherproducts

Hot-rolledstructuralshapesandbarsASTMA36

A572Grade42Allothergrades

HollowStructuralSections

ASTMA500,A501,A618andA847

SteelPipe

ASTMA53

1.1

1.5

1.3

1.1

1.3

1.4

Whenboththerequiredstrengthandthedesignstrengthcalculationsaremadeforthesamememberorconnectingelement,itispermittedtoapplyRytoFyinthedeterminationofthedesignstrength.”

PartI,Section6.3

Changethissectionasfollows:

“WhentheyareusedasmembersintheSeismicForceResistingSystem,ASTMA6Groups3,4,and5shapeswithflanges1?in.thickandthicker,ASTMA6Groups4and5shapes,andplatesthatare21?in.thickorthickerinbuilt-upcross-sectionsshallhaveaminimumCharpyV-Notch(CVN)toughnessof20ft-lbsat

70degreesF,determinedasspecifiedinLRFDSpecificationSectionA3.1c.”

PartI,Section7.3b

Changelanguageasfollows:

“Allcomplete-joint-penetrationgrooveweldsusedinprimarymembersandconnectionsintheSeismicForceResistingSystemshallbemadewithafillermetalthathasaminimumCVNCharpyV-notchtoughnessof20ft-lbsatminus20degreesF,asdeterminedbyAWSclassificationormanufacturercertification.Thisrequirement...<remainderunchanged>”

PartI,Section7.3c

Changethissectionasfollows:

“FormembersandconnectionsthatarepartoftheSeismicForceResistingSystem,discontinuitieslocatedwithinaplastichingingzoneasdefinedinSection7.4a,createdbyerrorsorbyfabricationorerectionoperations,suchastackwelds,erectionaids,air-arcgouging,andthermalflamecutting,shallberepairedasrequiredbytheEngineerofRecord.”

PartI,Section7.4

Addthefollowingnewsection:

“7.4.OtherConnections

7.4a.Weldedshearstudsshallnotbeplacedonbeamflangeswithinthezonesofexpectedplastichinging.Thelengthofaplastichingingzoneshallbedefinedasone-halfofthedepthofthebeamoneithersideofthetheoreticalhingepoint.Deckingarc-spotweldsasrequiredtosecuredeckingshallbepermitted.Deckingattachmentsthatpenetratethebeamflangesshallnotbeusedinthehingingzone.

7.4b.Welded,bolted,screwed,orshot-inattachmentsforperimeteredgeangles,exteriorfacades,partitions,ductwork,piping,orotherconstructionshallnotbeplacedwithintheexpectedzoneofplastichinging,asdefinedinSection7.4a,orofothermembersoftheSeismicForceResistingSystemwhichareexpectedtoundergoplastichinging.Outsidethedefinedhingearea,calculations,basedontheexpectedmomentattheplastichinge,shallbemadetodemonstratetheadequacyofthemembernetsectionwhenconnectorswhichpenetratethememberareused.

Exception:Weldedshearstudsandotherconnectionsarepermittedwheretheyhavebeenincludedintheconnectiontestsusedtoqualifytheconnection.”

PartI,Section8.3

Addthefollowingnewsection:

“8.3c.ColumnsplicesinSpecialMomentFramesshallbelocatedasdescribedinSection8.3a,andshallhaveanominalflexuralstrengththatisatleastequaltothenominalflexuralstrengthofthesmallercolumn.Wheregrooveweldsareusedtomakethesplice,theyshallbecomplete-joint-penetrationgroovewelds.WeldbackingneednotberemovedunlessrequiredbytheEngineerofRecord.Thedesignshearstrengthoftheconnectionshallbeequaltoorgreaterthantherequiredshearstrengthcalculatedusingtheexpectedyieldmomentsthatcanbedevelopedateachendofthecolumn.

Exception:Thedesignstrengthofthecolumnspliceneednotexceedtherequiredstrengthasdeterminedbyinelasticanalysesinwhichappropriatestressconcentrationfactorshavebeenconsideredforthetypeofconnectionbeingused.”

PartI,Section9.2a

Changethefirstsentenceasfollows:

“Thedesignofallbeam-to-columnjointsandconnectionsusedintheSeismicForceResistingSystemshallbebaseduponqualifying

cyclictestresultsinaccordancewithAppendixSthatdemonstrateaninterstorydriftangleofatleast0.04radiansinelasticrotationofatleast0.03radians.”

Addthefollowingsentenceattheendofthelastparagraph:“Columnsandconnectionelementswithatestedyieldstrengththatismorethan15percentaboveorbelowFyeshallnotbeusedinqualificationtesting.”

PartI,Section9.3a

Changethissectionasfollows:

“ShearStrength:TherequiredthicknessshearstrengthRuofthepanelzoneshallbedeterminedinaccordancewiththemethodusedinproportioningthepanelzoneofthetestedconnectionbyapplyingLoadCombinations4-1and4-2totheconnectedbeamorbeamsintheplaneoftheframeatthecolumn.Runeednotexceedtheshearforcedeterminedfrom0.8timesRyMpofthebeamsframingtothecolumnflangesattheconnection.Asaminimum,therequiredshearstrengthRuofthepanelzoneshallbedeterminedfromthesummationofthemomentsatthecolumnfacesasdeterminedbyprojectingtheexpectedmomentsattheplastichingepointstothecolumnfaces.Thedesignshearstrength

vRvofthepanelzoneshallbedeterminedusingv=0.751.0.WhenPu0.75Py,….”[Remainderunchanged].

PartI,Section9.4b

Changethissectionasfollows:

“Width-ThicknessRatios:BeamsshallcomplywithpinTableI-9-1.WhentheratioinEquation9-3islessthanorequalto2.01.25,columnsshallcomplywithpinTableI-9-1.Otherwise,columnsshallcomplywithpinLRFDSpecificationTableB5.1.”

PartI,Section9.6

ChangedefinitionofM*pbasfollows:

“Thesumofthemoment(s)inthebeam(s)attheintersectionofthebeamandcolumncenterlines.M*pbisdeterminedbysummingtheprojectionsoftheexpectedbeamflexuralstrength(s)...”

PartI,Section9.7a.1

ChangeSection9.7a.1.asfollows:

Columnflangesatbeam-to-columnconnectionsrequirelateralsupportonlyatthelevelofthetopflangesofthebeamswhenacolumnisshowntoremainelasticoutsideofthepanel-zone.undereitherofthefollowingconditions:ItshallbepermittedtoassumethatthecolumnremainselasticwhentheratiocalculatedusingEquation9-3isgreaterthan2.

a.TheratiocalculatedusingEquation9-3isgreaterthan1.25.b.ThecolumnremainselasticunderLoadCombination4-1.

PartI,Sections10&11

ReplaceSections10and11withthefollowing:

INTERMEDIATEMOMENTFRAMES(IMF)

Scope

IntermediateMomentFrames(IMF)areexpectedtowithstandlimitedinelasticdeformationsintheirmembersandconnectionswhensubjectedtotheforcesresultingfromthemotionsoftheDesignEarthquake.IMFshallmeettherequirementsinthisSection.

Beam-to-ColumnJointsandConnections

10.2a.Thedesignofallbeam-to-columnjointsandconnectionsusedintheSeismicForceResistingSystemshallbebaseduponqualifyingcyclictestresultsinaccordancewithAppendixSthatdemonstrateaninterstorydriftangleofatleast0.02radians.QualifyingcyclictestresultsshallconsistofatleasttwocyclictestsandshallmeettherequirementsinSection9.2a.

b.Beam-to-columnconnectiontestingshalldemonstrateaflexuralstrength,determinedatthecolumnface,thatisatleastequaltothenominalplasticmomentofthebeamMpattherequiredinelasticrotation(seeAppendixS),exceptasfollows:

Whenbeamlocalbucklingratherthanbeamyieldinglimitstheflexuralstrengthofthebeam,orwhenconnectionsincorporatingaReducedBeamSectionareused,theflexuralstrengthshallbetakenas0.8Mpofthetestedbeam.

Connectionsthataccommodatetherequiredrotationswithintheconnectionelementsand

maintainthedesignstrengthasspecifiedarepermitted,provideditcanbedemonstratedbyrationalanalysisthatanyadditionaldriftduetoconnectiondeformationcanbeaccommodatedbythebuilding.Suchrationalanalysisshallincludetheeffectsofoverallframestabilityincludingsecondordereffects.

TherequiredshearstrengthVuofabeam-to-columnconnectionshallbedeterminedusingtheloadcombination1.2D+0.5L+0.2Splustheshearresultingfromtheapplicationofamomentofmagnitudeequalto1.1RyFyZintheoppositesenseoneachendofthebeam.Alternatively,alesservalueofVuispermittedifjustifiedbyrationalanalysis.TherequiredshearstrengthneednotexceedtheshearresultingfromLoadCombination4-1.

ContinuityPlates

Continuityplatesshallbeprovidedtobeconsistentwiththetestedconnection.

ORDINARYMOMENTFRAMES(OMF)

Scope

OrdinaryMomentFrames(OMF)areexpectedtowithstandminimalinelasticdeformationsintheirmembersandconnectionswhensubjectedtotheforcesresultingfromthemotionsoftheDesignEarthquake.OMFshallmeettherequirementsinthisSection.

Beam-to-ColumnJointsandConnections

a.Beam-to-columnconnectionsshallbemadewithweldsand/orhigh-strengthbolts.ConnectionsarepermittedtobeFRorPRmomentconnectionsasfollows:

FRmomentconnectionsthatarepartoftheSeismicForceResistingSystemshallbedesignedforarequiredflexuralstrengthMuthatisatleastequalto1.1RyMpofthebeamorgirderorthemaximummomentthatcanbedeliveredbythesystem,whicheverisless.Forconnectionswithweldedflangejoints,weldbackingandweldtabsshallberemovedexceptthatthetop-flangebackingispermittedto

remaininplaceprovidedthatitisattachedtothecolumnflangebyacontinuousfilletweldontheedgebelowthecomplete-joint-penetrationgrooveweld.Afterremovalofweldbacking,thesurfaceshallberepairedandacontouringfilletweldadded.Weldtabsshallberemovedandthesurfacefinishedflushandsmooth.Single-sidedpartial-joint-penetrationgrooveweldsandsingle-sidedfilletweldsshallnotbeusedtoresisttensileforcesintheconnections.Double-sidedpartial-joint-penetrationgrooveweldsanddouble-sidedfilletweldsthatresisttensileforcesintheconnectionsshallbedesignedtoresistarequiredforceof1.1RyFyAgoftheconnectedelementorpart.

PRmomentconnectionsarepermittedwhenthefollowingrequirementsaremet:

SuchconnectionsshallprovideforthedesignstrengthasspecifiedinSection11.2a.1.

Thenominalflexuralstrengthoftheconnectionshallbenolessthan50percentofMpoftheconnectedbeamorcolumn,whicheverisless.

ThestiffnessandstrengthofthePRmomentconnectionsshallbeconsideredinthedesign,includingtheeffectonoverallframestability.

11.2b.ForFRmomentconnections,therequiredshearstrengthVuofabeam-to-columnconnectionshallbedeterminedusingtheloadcombination1.2D+0.5L+0.2Splustheshearresultingfromtheapplicationof1.1RyFyZintheoppositesenseoneachendofthebeam.Alternatively,alesservalueofVuispermittedifjustifiedbyrationalanalysis.ForPRmomentconnections,VushallbedeterminedfromtheloadcombinationaboveplustheshearresultingfromthemaximumendmomentthatthePRmomentconnectionsarecapableofresisting.

ContinuityPlates

WhenFRmomentconnectionsaremadebymeansofweldsofbeamflangesorbeam-flangeconnectionplatesdirectlytocolumnflanges,continuityplatesshallbeprovidedtotransmitbeamflangeforcestothecolumnweborwebs.Suchplatesshallhaveaminimumthicknessequaltothatofthebeamflangeorbeam-flangeconnectionplate.Theweldedjointsofthecontinuityplatestothecolumnflangesshallbemadewitheithercomplete-joint-penetrationgroovewelds,two-sidedpartial-joint-penetrationgrooveweldscombinedwithreinforcingfilletwelds,ortwo-sidedfilletweldsandshallprovideadesignstrengththatisatleastequaltothedesignstrengthofthecontactareaoftheplatewiththecolumnflange.Theweldedjointsofthecontinuityplatestothecolumnwebshallhaveadesignshearstrengththatisatleastequaltothelesserofthefollowing:

Thesumofthedesignstrengthsattheconnectionsofthecontinuityplatetothecolumnflanges.

Thedesignshearstrengthofthecontactareaoftheplatewiththecolumnweb.

Thewelddesignstrengththatdevelopsthedesignshearstrengthofthecolumnpanel-zone.

Theactualforcetransmittedbythestiffener.

Continuityplatesarenotrequirediftestedconnectionsdemonstratethattheintendedinelasticrotationcanbeachievedwithouttheiruse.

PartI,Section13.2d

Changelanguageasfollows:

“Width-thicknessRatios:Width-thicknessratiosofstiffenedandunstiffenedcompressionelementsofbracesshallmeetthecompactnessrequirementsinLRFDSpecificationTableB5.1(i.e.,

<p)andthefollowingrequirements:

Bracedshallbecompact(i.e.,<p).Thewidth-thickness

Fy

ratioofanglesshallnotexceed52/ .

I-shapedmembersandchannelsusedasbracesshallcomplywithpinTableI-9-1.

RoundHSSshallhave…<remainderunchanged>”

PartI,Sections14.2through14.5

DeleteSections14.2through14.5andreplacewiththefollowing:

“14.2Strength

Fy

Therequiredstrengthofthemembersandconnections,otherthanbraceconnections,inOCBFsshallbebaseduponLoadCombinations4-1and4-2.Thedesignstrengthofbraceconnectionsshallequalorexceedtheexpectedtensilestrengthofthebrace,determinedasRyFyAg.Braces

withKl/rgreaterthan720/

inverted-Vconfigurations.”

shallnotbeusedinVor

PartI,Section16

AddthefollowingsentenceattheendoftheSection:

“Whenweldsfromwebdoublerplatesorcontinuityplatesoccurinthe‘k-area’ofrolledsteelcolumns,the‘k-area’adjacenttotheweldsshallbeinspectedafterfabrication,asrequiredbytheEngineerofRecord,usingapprovednondestructivemethodsconformingtoAWSD1.1.”

AppendixS,SectionS2

Replacethissectionwiththefollowing:

“S2.SYMBOLS

ThenumberinparenthesisafterthedefinitionofasymbolreferstotheSectionnumberinwhichthesymbolisfirstused.

Interstorydriftangle(S6)

Linkrotationangle(S6)”

AppendixS,SectionS3

Addthefollowingdefinitions:

“CompleteLoadingCycle.Acycleofrotationtakenfromzeroforcetozeroforce,includingonepositiveandonenegativepeak.”

“InterstoryDriftAngle.Interstorydisplacementdividedbystoryheight,radians.”

ReplacethedefinitionofInelasticRotationwiththefollowing:“InelasticRotation.ThepermanentorplasticportionoftherotationanglebetweenabeamandthecolumnorbetweenaLinkandthecolumnoftheTestSpecimen,measuredinradians.The

InelasticRotationshallbecomputedbasedonananalysisofTestSpecimendeformations.Sourcesofinelasticrotationincludeyieldingofmembers,yieldingofconnectionelementsandconnectors,andslipbetweenmembersandconnectionelements.Forbeam-to-columnmomentconnectionsinMomentFrames,inelasticrotationshallbecomputedbasedupontheassumptionthatinelasticactionisconcentratedatasinglepointlocatedattheintersectionofthecenterlineofthebeamwiththecenterlineofthecolumn.Forlink-to-columnconnectionsinEccentricallyBracedFrames,inelasticrotationshallbecomputedbasedupontheassumptionthatinelasticactionisconcentratedatasinglepointlocatedattheintersectionofthecenterlineofthelinkwiththefaceofthecolumn.”

AppendixS,SectionS5.5

Change#2asfollows:

“2.Theyieldstressofthebeamshallnotbemorethan15percentbelowFyeforthegradeofsteeltobeusedforthecorrespondingelementsofthePrototype.Columnsandconnectionelementswithatestedyieldstressshallnotbemorethan15percentaboveorbelowFyeforthegradeofsteeltobeusedforthecorrespondingelementsofthePrototype.FyeshallbedeterminedinaccordancewithSection6.2.”

AppendixS,SectionS6.1

Replacethissectionwiththefollowing:

“S6.1.GeneralRequirements

TheTestSpecimenshallbesubjectedtocyclicloadsaccordingtotherequirementsprescribedinSectionS6.2forbeam-to-columnmomentconnectionsinMomentFrames,andaccordingtotherequirementsprescribedinSectionS6.3forlink-to-columnconnectionsinEccentricallyBracedFrames.

LoadingsequencesotherthanthosespecifiedinSectionsS6.2andS6.3maybeusedwhentheyaredemonstratedtobeofequivalentorgreaterseverity.”

AppendixS,SectionS6.2

Replacethissectionwiththefollowing:

“S6.2LoadingSequenceforBeam-to-ColumnMomentConnections

Qualifyingcyclictestsofbeam-to-columnmomentconnectionsinMomentFramesshallbeconductedbycontrollingtheinterstorydriftangle,,imposedontheTestSpecimen,asfollows:

6cyclesat=0.00375rad.

6cyclesat=0.005rad.

6cyclesat=0.0075rad.

4cyclesat=0.01rad.

2cyclesat=0.015rad.

2cyclesat=0.02rad.

2cyclesat=0.03rad.

Continueloadingatincrementsof=0.01rad.,withtwocyclesofloadingateachstep.”

AppendixS,SectionS6.3

Replacethissectionwiththefollowing:

“S6.3LoadingSequenceforLink-to-ColumnConnectionsQualifying cyclic tests of link-to-column momentconnectionsinEccentricallyBracedFramesshallbeconductedbycontrollingthelinkrotationangle,,imposedontheTestSpecimen,asfollows:

3cyclesat=0.0025rad.

3cyclesat=0.005rad.

3cyclesat=0.01rad.

2cyclesat=0.02rad.

2cyclesat=0.03rad.

Continueloadingatincrementsof=0.01rad.,withtwocyclesofloadingateachstep.”

AppendixS,SectionS9

ChangeItemNo.6.asfollows:

“6.AplotofbeammomentversustotalInelasticRotationinterstorydriftangleforbeam-to-columnmomentconnections;oraplotoflinkshearforceversuslinkrotation

angleforlink-to-columnconnections.Forbeam-to-columnconnections,thebeammomentandthetotalInelasticRotationinterstorydriftangleshallbecomputedwithrespecttothefacecenterlineofthecolumn.”

ChangeItemNo.7asfollows:

“7.TheinterstorydriftangleandthetotalInelasticRotationdevelopedbytheTestSpecimen.<Remainderunchanged>”

AppendixS,SectionS10

Changethissectionasfollows:

“Foreachconnectionusedintheactualframe,atleasttwotestsarerequiredforeachconnectioninwhichtheEssentialVariables,aslistedinSectionS4,remainwithintherequiredlimits.BothtestsshallsatisfythecriteriastipulatedinSections8.5,9.2,10.2,or15.4,asapplicable.InordertosatisfyInelasticRotationinterstorydriftanglerequirements,eachTestSpecimenshallsustaintherequiredrotationinterstorydriftangleforatleastonecompleteloadingcycle.”

PartII,Section6.5c

ChangeEquation6-3asfollows:

1.40bFy/Es

Fy/(2Es)

b (6-3)

PartII,Section13.4

ChangePartII,Section13.4asfollows:

“13.4.Braces

StructuralsteelbracesshallmeettherequirementsforOCBFSCBFinPartISection1413.CompositebracesshallmeettherequirementsforcompositecolumnsinSection13.2.”

PartII,Section13.5

ChangePartII,Section13.5asfollows:

“BracingconnectionsshallmeettherequirementsinSection7andPartISection1413.”

CommentaryPartI,SectionC1

Addthefollowingparagraph:

“Itshouldbenotedthattheseprovisionsweredevelopedspecificallyforbuildings.Theprovisions,therefore,maynotbeapplicable,inwholeorinpart,tonon-buildingstructures.Extrapolationoftheirusetonon-buildingstructuresshouldbedonewithdueconsiderationoftheinherentdifferencesbetweentheresponsecharacteristicsofbuildingsandnon-buildingstructures.”

CommentaryPartI,SectionC4

Replaceallreferencesto“1997NEHRPProvisions(FEMA,1997A)”with“2000NEHRPProvisions(FEMA,2000e)”.

InTableI-C4-1replacethevaluesgivenforIntermediateMomentFrames(IMF)andOrdinaryMomentFrames(OMF)withthefollowing:

BASICSTRUCTURALSYSTEMANDSEISMICFORCERESISTINGSYSTEM

R

Cd

IntermediateMomentFrames(IMF)

4.5

4

OrdinaryMomentFrames(OMF)

3.5

3

CommentaryPartI,SectionC6.2

Addthefollowingtotheendofthissection:

“WhileASTMA709isprimarilyusedinthedesignandconstructionofbridges,itcouldalsobeusedinbuildingconstruction.Writtenasanumbrellaspecification,itsgradesareessentiallytheequivalentofotherapprovedASTMspecifications.Forexample,ASTMA709grade50isessentiallyASTMA572grade50andASTMA709grade50WisessentiallyASTMA588grade50.Thus,ifused,ASTMA709materialshouldbetreatedaswouldthecorrespondingapprovedASTMmaterialgrade.”

CommentaryPartI,SectionC6.3

ChangeItem(3)inthefirstparagraphasfollows:

“…(3)plateelementswiththicknessgreaterthanorequalto21?in.thatarepartoftheSeismicForceResistingSystem,suchastheflangesofbuilt-upgirders.”

CommentaryPartI,SectionC7.3

Changethefirstsentenceofthesecondparagraphofthissectionasfollows:

“ForallweldsusedinprimarymembersandconnectionsintheSeismicForceResistingSystem,weldmetalnotchtoughnessisrequiredintheseProvisions.”

Addthefollowingsentencetotheendofthesecondparagraph:“TheseweldtoughnessrequirementsarenotintendedtoapplytoERWandSAWweldingprocessesusedintheproductionofHSS(ASTMA500)andpipesections(ASTMA53).”

Addthefollowingsentencetotheendofthelastparagraphofthissection:

“TheEngineerofRecordshouldrefertoAWSD1.1forguidanceinestablishingtheacceptancecriteriaforrepairofdiscontinuities.Outsidetheplastichingeregions,AWSD1.1requirementsforrepairofdiscontinuitiesshouldbeapplied.”

CommentaryPartI,SectionC7.4

AddthefollowingnewcommentarySectionC7.4:“C7.4OtherConnections

TheFEMA/SACtestinghasdemonstratedthesensitivityofregionsundergoinglargeinelasticstrainstodiscontinuitiescausedbywelding,rapidchangeofsection,penetrations,orconstructioncausedflaws.Forthisreason,operationsthatcausediscontinuitiesareprohibitedinthecriticalhingingregion.Areaswherecriticalhingingisexpectedincludemomentframehingingzonesasdefined,linkbeamsofEBFs,theendsandthecenterofSCBFbraces,etc.Itshouldbenotedthatyieldlevelstrainsarenotstrictlylimitedtotheplastichingezones(beam-columnjointregionforcoverplateorRBSconnections,e.g.).Cautionshouldalsobeexercisedincreatingdiscontinuitiesintheseregionsaswell.”

CommentaryPartI,SectionC8.3

ReplaceCommentarySectionC8.3withthefollowing:“C8.3ColumnSplices

InelasticanalysesconductedaspartoftheFEMA/SACprogramhavedemonstratedthatthecommonassumptionthatcolumnflexuralstressesinthemid-heightofmoment

framecolumnsarelowisnotnecessarilytrue.Bendingmomentsequaling,orexceeding,theyieldmomentofthecolumnarepossibleatcolumnsplices,evenwhenthesplicesarelocatedasrequiredbySection8.3a.Accordingly,therequirementisgiventhatthenominalflexuralstrengthofthespliceshouldequalorexceedthenominalflexuralstrengthofthesmallercolumn.Itisnotnecessarytoapplyover-strengthfactorsandfactorstotherequirement,sinceitisacomparisonofrelativemembernominalstrengths.

TheexceptionisprovidedtoallowforcaseswheretheEngineerofRecordcandemonstratethatthelargestdemandsthatcanoccuratcolumnsplicesarebelowtheyieldlevel.Inelasticdynamicanalysesarerequiredtojustifyusingthisexception.Inthesecases,theuseofweldedjointsotherthancomplete-joint-penetrationgrooveweldsmaybeused,providedthatstressconcentrationfactors(e.g.estimatedusingafracturemechanicsapproach)generatedbytheproposedjointconfigurationaretakenintoaccount.”

CommentaryPartI,SectionC9.2a

Addthefollowing:

“LimitationsareplacedonpermissibledifferencesbetweenthetestedyieldstrengthandFyeforbeams,columnsandconnectionelements.Itisnotintendedthattheselimitationsbeappliedretroactivelytotheexistingdatabaseofqualificationtests.Rather,theserequirementsareintendedtoapplyforuseinnewqualificationtesting.”

FEMA350,RecommendedSeismicDesignCriteriaforNewSteelMoment-FrameBuildingsincludesrecommendationsfordesignandfabricationofseveraltypesofconnectionswhicharedeemedtobeprequalifiedforuseinSpecialMomentFramesofsteel.TheseconnectiondesignsarebasedonextensivetestingandanalysisperformedbytheSACJointVentureunderaprogra

溫馨提示

  • 1. 本站所有資源如無特殊說明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請下載最新的WinRAR軟件解壓。
  • 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請聯(lián)系上傳者。文件的所有權(quán)益歸上傳用戶所有。
  • 3. 本站RAR壓縮包中若帶圖紙,網(wǎng)頁內(nèi)容里面會有圖紙預覽,若沒有圖紙預覽就沒有圖紙。
  • 4. 未經(jīng)權(quán)益所有人同意不得將文件中的內(nèi)容挪作商業(yè)或盈利用途。
  • 5. 人人文庫網(wǎng)僅提供信息存儲空間,僅對用戶上傳內(nèi)容的表現(xiàn)方式做保護處理,對用戶上傳分享的文檔內(nèi)容本身不做任何修改或編輯,并不能對任何下載內(nèi)容負責。
  • 6. 下載文件中如有侵權(quán)或不適當內(nèi)容,請與我們聯(lián)系,我們立即糾正。
  • 7. 本站不保證下載資源的準確性、安全性和完整性, 同時也不承擔用戶因使用這些下載資源對自己和他人造成任何形式的傷害或損失。

評論

0/150

提交評論