版權(quán)說明:本文檔由用戶提供并上傳,收益歸屬內(nèi)容提供方,若內(nèi)容存在侵權(quán),請進行舉報或認領(lǐng)
文檔簡介
SeismicProvisionsforStructural
SteelBuildings(1997)
SupplementNo.2
November10,2000
SupersedesSupplementNo.1totheAISCSeismicProvisionsforStructuralSteelBuildings,datedFebruary15,1999
PreparedbytheAmericanInstituteofSteelConstruction,Inc.underthedirectionoftheAISCCommitteeonSpecificationsand
approvedbytheAISCBoardofDirectors
AMERICANINSTITUTEOFSTEELCONSTRUCTION,INC.
OneEastWackerDrive,Suite3100,Chicago,Illinois60601-2001
PAGE
10
AISCSeismicProvisions(1997)SupplementNo.2(11/00)
AISCSeismicProvisions(1997)SupplementNo.2(11/00)
PAGE
11
AMERICANINSTITUTEOFSTEELCONSTRUCTION
AMERICANINSTITUTEOFSTEELCONSTRUCTION
SeismicProvisionsforStructural
SteelBuildings(1997)
SupplementNo.2
November10,2000
PartI,Glossary
DeletethedefinitionofInelasticRotationofBeam-to-ColumnConnection.
Addthefollowingdefinitions:
“InterstoryDriftAngle.Interstorydisplacementdividedbystoryheight,radians.
ZipperColumn.Avertical(ornearlyvertical)strutconnectingthebrace-to-beamintersectionofaninverted-V-bracedframeatoneleveltothebrace-to-beamintersectionatanotherlevel.SeeFigureC-13.4(b).”
ChangedefinitionofReducedBeamSectionasfollows:
“Aductilereductionincross-section...<remainderunchanged>”
PartI,Section2
Changethissectionasfollows:
...
AmericanSocietyofCivilEngineersASCE7-9598
AmericanSocietyforTestingandMaterials
ASTMA6-96b98
ASTMA500-9399
ASTMA673-95
ASTMA36-9697a
ASTMA501-9399
ASTMA913-95a97
ASTMA53-9699b
ASTMA572-94c99
ASTMA992-98
ASTMA283-93a
ASTMA588-9497a
AmericanWeldingSocietyAWSD1.1-96D1.1:2000
….
PartI,Section6.1
AddASTMA992tothelistofmaterialspecificationsthatareapprovedforuseintheSeismicForceResistingSystem.
PartI,Section6.2
Changethissectionasfollows:
“WhenrequiredintheseProvisions,therequiredstrengthofaconnectionorrelatedmembershallbedeterminedfromtheExpectedYieldStrengthFyeoftheconnectedmember,where
Fye=RyFy (6-1)
Fyisthespecifiedminimumyieldstrengthofthegradeofsteeltobeused.Forrolledshapesandbars,RyshallbeasshowninTableI-6-1takenas1.5forASTMA36and1.3forA572Grade42.Forrolledshapesandbarsofothergradesofsteelandforplates,Ryshallbetakenas1.1.OthervaluesofRyarepermittedtobeusedifthevalueofFyeisdeterminedbytestingthatisconductedinaccordancewiththerequirementsforthespecifiedgradeofsteel.
TABLEI-6-1
RyValuesforDifferentMemberTypes
Application
Ry
Platesandallotherproducts
Hot-rolledstructuralshapesandbarsASTMA36
A572Grade42Allothergrades
HollowStructuralSections
ASTMA500,A501,A618andA847
SteelPipe
ASTMA53
1.1
1.5
1.3
1.1
1.3
1.4
Whenboththerequiredstrengthandthedesignstrengthcalculationsaremadeforthesamememberorconnectingelement,itispermittedtoapplyRytoFyinthedeterminationofthedesignstrength.”
PartI,Section6.3
Changethissectionasfollows:
“WhentheyareusedasmembersintheSeismicForceResistingSystem,ASTMA6Groups3,4,and5shapeswithflanges1?in.thickandthicker,ASTMA6Groups4and5shapes,andplatesthatare21?in.thickorthickerinbuilt-upcross-sectionsshallhaveaminimumCharpyV-Notch(CVN)toughnessof20ft-lbsat
70degreesF,determinedasspecifiedinLRFDSpecificationSectionA3.1c.”
PartI,Section7.3b
Changelanguageasfollows:
“Allcomplete-joint-penetrationgrooveweldsusedinprimarymembersandconnectionsintheSeismicForceResistingSystemshallbemadewithafillermetalthathasaminimumCVNCharpyV-notchtoughnessof20ft-lbsatminus20degreesF,asdeterminedbyAWSclassificationormanufacturercertification.Thisrequirement...<remainderunchanged>”
PartI,Section7.3c
Changethissectionasfollows:
“FormembersandconnectionsthatarepartoftheSeismicForceResistingSystem,discontinuitieslocatedwithinaplastichingingzoneasdefinedinSection7.4a,createdbyerrorsorbyfabricationorerectionoperations,suchastackwelds,erectionaids,air-arcgouging,andthermalflamecutting,shallberepairedasrequiredbytheEngineerofRecord.”
PartI,Section7.4
Addthefollowingnewsection:
“7.4.OtherConnections
7.4a.Weldedshearstudsshallnotbeplacedonbeamflangeswithinthezonesofexpectedplastichinging.Thelengthofaplastichingingzoneshallbedefinedasone-halfofthedepthofthebeamoneithersideofthetheoreticalhingepoint.Deckingarc-spotweldsasrequiredtosecuredeckingshallbepermitted.Deckingattachmentsthatpenetratethebeamflangesshallnotbeusedinthehingingzone.
7.4b.Welded,bolted,screwed,orshot-inattachmentsforperimeteredgeangles,exteriorfacades,partitions,ductwork,piping,orotherconstructionshallnotbeplacedwithintheexpectedzoneofplastichinging,asdefinedinSection7.4a,orofothermembersoftheSeismicForceResistingSystemwhichareexpectedtoundergoplastichinging.Outsidethedefinedhingearea,calculations,basedontheexpectedmomentattheplastichinge,shallbemadetodemonstratetheadequacyofthemembernetsectionwhenconnectorswhichpenetratethememberareused.
Exception:Weldedshearstudsandotherconnectionsarepermittedwheretheyhavebeenincludedintheconnectiontestsusedtoqualifytheconnection.”
PartI,Section8.3
Addthefollowingnewsection:
“8.3c.ColumnsplicesinSpecialMomentFramesshallbelocatedasdescribedinSection8.3a,andshallhaveanominalflexuralstrengththatisatleastequaltothenominalflexuralstrengthofthesmallercolumn.Wheregrooveweldsareusedtomakethesplice,theyshallbecomplete-joint-penetrationgroovewelds.WeldbackingneednotberemovedunlessrequiredbytheEngineerofRecord.Thedesignshearstrengthoftheconnectionshallbeequaltoorgreaterthantherequiredshearstrengthcalculatedusingtheexpectedyieldmomentsthatcanbedevelopedateachendofthecolumn.
Exception:Thedesignstrengthofthecolumnspliceneednotexceedtherequiredstrengthasdeterminedbyinelasticanalysesinwhichappropriatestressconcentrationfactorshavebeenconsideredforthetypeofconnectionbeingused.”
PartI,Section9.2a
Changethefirstsentenceasfollows:
“Thedesignofallbeam-to-columnjointsandconnectionsusedintheSeismicForceResistingSystemshallbebaseduponqualifying
cyclictestresultsinaccordancewithAppendixSthatdemonstrateaninterstorydriftangleofatleast0.04radiansinelasticrotationofatleast0.03radians.”
Addthefollowingsentenceattheendofthelastparagraph:“Columnsandconnectionelementswithatestedyieldstrengththatismorethan15percentaboveorbelowFyeshallnotbeusedinqualificationtesting.”
PartI,Section9.3a
Changethissectionasfollows:
“ShearStrength:TherequiredthicknessshearstrengthRuofthepanelzoneshallbedeterminedinaccordancewiththemethodusedinproportioningthepanelzoneofthetestedconnectionbyapplyingLoadCombinations4-1and4-2totheconnectedbeamorbeamsintheplaneoftheframeatthecolumn.Runeednotexceedtheshearforcedeterminedfrom0.8timesRyMpofthebeamsframingtothecolumnflangesattheconnection.Asaminimum,therequiredshearstrengthRuofthepanelzoneshallbedeterminedfromthesummationofthemomentsatthecolumnfacesasdeterminedbyprojectingtheexpectedmomentsattheplastichingepointstothecolumnfaces.Thedesignshearstrength
vRvofthepanelzoneshallbedeterminedusingv=0.751.0.WhenPu0.75Py,….”[Remainderunchanged].
PartI,Section9.4b
Changethissectionasfollows:
“Width-ThicknessRatios:BeamsshallcomplywithpinTableI-9-1.WhentheratioinEquation9-3islessthanorequalto2.01.25,columnsshallcomplywithpinTableI-9-1.Otherwise,columnsshallcomplywithpinLRFDSpecificationTableB5.1.”
PartI,Section9.6
ChangedefinitionofM*pbasfollows:
“Thesumofthemoment(s)inthebeam(s)attheintersectionofthebeamandcolumncenterlines.M*pbisdeterminedbysummingtheprojectionsoftheexpectedbeamflexuralstrength(s)...”
PartI,Section9.7a.1
ChangeSection9.7a.1.asfollows:
Columnflangesatbeam-to-columnconnectionsrequirelateralsupportonlyatthelevelofthetopflangesofthebeamswhenacolumnisshowntoremainelasticoutsideofthepanel-zone.undereitherofthefollowingconditions:ItshallbepermittedtoassumethatthecolumnremainselasticwhentheratiocalculatedusingEquation9-3isgreaterthan2.
a.TheratiocalculatedusingEquation9-3isgreaterthan1.25.b.ThecolumnremainselasticunderLoadCombination4-1.
PartI,Sections10&11
ReplaceSections10and11withthefollowing:
INTERMEDIATEMOMENTFRAMES(IMF)
Scope
IntermediateMomentFrames(IMF)areexpectedtowithstandlimitedinelasticdeformationsintheirmembersandconnectionswhensubjectedtotheforcesresultingfromthemotionsoftheDesignEarthquake.IMFshallmeettherequirementsinthisSection.
Beam-to-ColumnJointsandConnections
10.2a.Thedesignofallbeam-to-columnjointsandconnectionsusedintheSeismicForceResistingSystemshallbebaseduponqualifyingcyclictestresultsinaccordancewithAppendixSthatdemonstrateaninterstorydriftangleofatleast0.02radians.QualifyingcyclictestresultsshallconsistofatleasttwocyclictestsandshallmeettherequirementsinSection9.2a.
b.Beam-to-columnconnectiontestingshalldemonstrateaflexuralstrength,determinedatthecolumnface,thatisatleastequaltothenominalplasticmomentofthebeamMpattherequiredinelasticrotation(seeAppendixS),exceptasfollows:
Whenbeamlocalbucklingratherthanbeamyieldinglimitstheflexuralstrengthofthebeam,orwhenconnectionsincorporatingaReducedBeamSectionareused,theflexuralstrengthshallbetakenas0.8Mpofthetestedbeam.
Connectionsthataccommodatetherequiredrotationswithintheconnectionelementsand
maintainthedesignstrengthasspecifiedarepermitted,provideditcanbedemonstratedbyrationalanalysisthatanyadditionaldriftduetoconnectiondeformationcanbeaccommodatedbythebuilding.Suchrationalanalysisshallincludetheeffectsofoverallframestabilityincludingsecondordereffects.
TherequiredshearstrengthVuofabeam-to-columnconnectionshallbedeterminedusingtheloadcombination1.2D+0.5L+0.2Splustheshearresultingfromtheapplicationofamomentofmagnitudeequalto1.1RyFyZintheoppositesenseoneachendofthebeam.Alternatively,alesservalueofVuispermittedifjustifiedbyrationalanalysis.TherequiredshearstrengthneednotexceedtheshearresultingfromLoadCombination4-1.
ContinuityPlates
Continuityplatesshallbeprovidedtobeconsistentwiththetestedconnection.
ORDINARYMOMENTFRAMES(OMF)
Scope
OrdinaryMomentFrames(OMF)areexpectedtowithstandminimalinelasticdeformationsintheirmembersandconnectionswhensubjectedtotheforcesresultingfromthemotionsoftheDesignEarthquake.OMFshallmeettherequirementsinthisSection.
Beam-to-ColumnJointsandConnections
a.Beam-to-columnconnectionsshallbemadewithweldsand/orhigh-strengthbolts.ConnectionsarepermittedtobeFRorPRmomentconnectionsasfollows:
FRmomentconnectionsthatarepartoftheSeismicForceResistingSystemshallbedesignedforarequiredflexuralstrengthMuthatisatleastequalto1.1RyMpofthebeamorgirderorthemaximummomentthatcanbedeliveredbythesystem,whicheverisless.Forconnectionswithweldedflangejoints,weldbackingandweldtabsshallberemovedexceptthatthetop-flangebackingispermittedto
remaininplaceprovidedthatitisattachedtothecolumnflangebyacontinuousfilletweldontheedgebelowthecomplete-joint-penetrationgrooveweld.Afterremovalofweldbacking,thesurfaceshallberepairedandacontouringfilletweldadded.Weldtabsshallberemovedandthesurfacefinishedflushandsmooth.Single-sidedpartial-joint-penetrationgrooveweldsandsingle-sidedfilletweldsshallnotbeusedtoresisttensileforcesintheconnections.Double-sidedpartial-joint-penetrationgrooveweldsanddouble-sidedfilletweldsthatresisttensileforcesintheconnectionsshallbedesignedtoresistarequiredforceof1.1RyFyAgoftheconnectedelementorpart.
PRmomentconnectionsarepermittedwhenthefollowingrequirementsaremet:
SuchconnectionsshallprovideforthedesignstrengthasspecifiedinSection11.2a.1.
Thenominalflexuralstrengthoftheconnectionshallbenolessthan50percentofMpoftheconnectedbeamorcolumn,whicheverisless.
ThestiffnessandstrengthofthePRmomentconnectionsshallbeconsideredinthedesign,includingtheeffectonoverallframestability.
11.2b.ForFRmomentconnections,therequiredshearstrengthVuofabeam-to-columnconnectionshallbedeterminedusingtheloadcombination1.2D+0.5L+0.2Splustheshearresultingfromtheapplicationof1.1RyFyZintheoppositesenseoneachendofthebeam.Alternatively,alesservalueofVuispermittedifjustifiedbyrationalanalysis.ForPRmomentconnections,VushallbedeterminedfromtheloadcombinationaboveplustheshearresultingfromthemaximumendmomentthatthePRmomentconnectionsarecapableofresisting.
ContinuityPlates
WhenFRmomentconnectionsaremadebymeansofweldsofbeamflangesorbeam-flangeconnectionplatesdirectlytocolumnflanges,continuityplatesshallbeprovidedtotransmitbeamflangeforcestothecolumnweborwebs.Suchplatesshallhaveaminimumthicknessequaltothatofthebeamflangeorbeam-flangeconnectionplate.Theweldedjointsofthecontinuityplatestothecolumnflangesshallbemadewitheithercomplete-joint-penetrationgroovewelds,two-sidedpartial-joint-penetrationgrooveweldscombinedwithreinforcingfilletwelds,ortwo-sidedfilletweldsandshallprovideadesignstrengththatisatleastequaltothedesignstrengthofthecontactareaoftheplatewiththecolumnflange.Theweldedjointsofthecontinuityplatestothecolumnwebshallhaveadesignshearstrengththatisatleastequaltothelesserofthefollowing:
Thesumofthedesignstrengthsattheconnectionsofthecontinuityplatetothecolumnflanges.
Thedesignshearstrengthofthecontactareaoftheplatewiththecolumnweb.
Thewelddesignstrengththatdevelopsthedesignshearstrengthofthecolumnpanel-zone.
Theactualforcetransmittedbythestiffener.
Continuityplatesarenotrequirediftestedconnectionsdemonstratethattheintendedinelasticrotationcanbeachievedwithouttheiruse.
PartI,Section13.2d
Changelanguageasfollows:
“Width-thicknessRatios:Width-thicknessratiosofstiffenedandunstiffenedcompressionelementsofbracesshallmeetthecompactnessrequirementsinLRFDSpecificationTableB5.1(i.e.,
<p)andthefollowingrequirements:
Bracedshallbecompact(i.e.,<p).Thewidth-thickness
Fy
ratioofanglesshallnotexceed52/ .
I-shapedmembersandchannelsusedasbracesshallcomplywithpinTableI-9-1.
RoundHSSshallhave…<remainderunchanged>”
PartI,Sections14.2through14.5
DeleteSections14.2through14.5andreplacewiththefollowing:
“14.2Strength
Fy
Therequiredstrengthofthemembersandconnections,otherthanbraceconnections,inOCBFsshallbebaseduponLoadCombinations4-1and4-2.Thedesignstrengthofbraceconnectionsshallequalorexceedtheexpectedtensilestrengthofthebrace,determinedasRyFyAg.Braces
withKl/rgreaterthan720/
inverted-Vconfigurations.”
shallnotbeusedinVor
PartI,Section16
AddthefollowingsentenceattheendoftheSection:
“Whenweldsfromwebdoublerplatesorcontinuityplatesoccurinthe‘k-area’ofrolledsteelcolumns,the‘k-area’adjacenttotheweldsshallbeinspectedafterfabrication,asrequiredbytheEngineerofRecord,usingapprovednondestructivemethodsconformingtoAWSD1.1.”
AppendixS,SectionS2
Replacethissectionwiththefollowing:
“S2.SYMBOLS
ThenumberinparenthesisafterthedefinitionofasymbolreferstotheSectionnumberinwhichthesymbolisfirstused.
Interstorydriftangle(S6)
Linkrotationangle(S6)”
AppendixS,SectionS3
Addthefollowingdefinitions:
“CompleteLoadingCycle.Acycleofrotationtakenfromzeroforcetozeroforce,includingonepositiveandonenegativepeak.”
“InterstoryDriftAngle.Interstorydisplacementdividedbystoryheight,radians.”
ReplacethedefinitionofInelasticRotationwiththefollowing:“InelasticRotation.ThepermanentorplasticportionoftherotationanglebetweenabeamandthecolumnorbetweenaLinkandthecolumnoftheTestSpecimen,measuredinradians.The
InelasticRotationshallbecomputedbasedonananalysisofTestSpecimendeformations.Sourcesofinelasticrotationincludeyieldingofmembers,yieldingofconnectionelementsandconnectors,andslipbetweenmembersandconnectionelements.Forbeam-to-columnmomentconnectionsinMomentFrames,inelasticrotationshallbecomputedbasedupontheassumptionthatinelasticactionisconcentratedatasinglepointlocatedattheintersectionofthecenterlineofthebeamwiththecenterlineofthecolumn.Forlink-to-columnconnectionsinEccentricallyBracedFrames,inelasticrotationshallbecomputedbasedupontheassumptionthatinelasticactionisconcentratedatasinglepointlocatedattheintersectionofthecenterlineofthelinkwiththefaceofthecolumn.”
AppendixS,SectionS5.5
Change#2asfollows:
“2.Theyieldstressofthebeamshallnotbemorethan15percentbelowFyeforthegradeofsteeltobeusedforthecorrespondingelementsofthePrototype.Columnsandconnectionelementswithatestedyieldstressshallnotbemorethan15percentaboveorbelowFyeforthegradeofsteeltobeusedforthecorrespondingelementsofthePrototype.FyeshallbedeterminedinaccordancewithSection6.2.”
AppendixS,SectionS6.1
Replacethissectionwiththefollowing:
“S6.1.GeneralRequirements
TheTestSpecimenshallbesubjectedtocyclicloadsaccordingtotherequirementsprescribedinSectionS6.2forbeam-to-columnmomentconnectionsinMomentFrames,andaccordingtotherequirementsprescribedinSectionS6.3forlink-to-columnconnectionsinEccentricallyBracedFrames.
LoadingsequencesotherthanthosespecifiedinSectionsS6.2andS6.3maybeusedwhentheyaredemonstratedtobeofequivalentorgreaterseverity.”
AppendixS,SectionS6.2
Replacethissectionwiththefollowing:
“S6.2LoadingSequenceforBeam-to-ColumnMomentConnections
Qualifyingcyclictestsofbeam-to-columnmomentconnectionsinMomentFramesshallbeconductedbycontrollingtheinterstorydriftangle,,imposedontheTestSpecimen,asfollows:
6cyclesat=0.00375rad.
6cyclesat=0.005rad.
6cyclesat=0.0075rad.
4cyclesat=0.01rad.
2cyclesat=0.015rad.
2cyclesat=0.02rad.
2cyclesat=0.03rad.
Continueloadingatincrementsof=0.01rad.,withtwocyclesofloadingateachstep.”
AppendixS,SectionS6.3
Replacethissectionwiththefollowing:
“S6.3LoadingSequenceforLink-to-ColumnConnectionsQualifying cyclic tests of link-to-column momentconnectionsinEccentricallyBracedFramesshallbeconductedbycontrollingthelinkrotationangle,,imposedontheTestSpecimen,asfollows:
3cyclesat=0.0025rad.
3cyclesat=0.005rad.
3cyclesat=0.01rad.
2cyclesat=0.02rad.
2cyclesat=0.03rad.
Continueloadingatincrementsof=0.01rad.,withtwocyclesofloadingateachstep.”
AppendixS,SectionS9
ChangeItemNo.6.asfollows:
“6.AplotofbeammomentversustotalInelasticRotationinterstorydriftangleforbeam-to-columnmomentconnections;oraplotoflinkshearforceversuslinkrotation
angleforlink-to-columnconnections.Forbeam-to-columnconnections,thebeammomentandthetotalInelasticRotationinterstorydriftangleshallbecomputedwithrespecttothefacecenterlineofthecolumn.”
ChangeItemNo.7asfollows:
“7.TheinterstorydriftangleandthetotalInelasticRotationdevelopedbytheTestSpecimen.<Remainderunchanged>”
AppendixS,SectionS10
Changethissectionasfollows:
“Foreachconnectionusedintheactualframe,atleasttwotestsarerequiredforeachconnectioninwhichtheEssentialVariables,aslistedinSectionS4,remainwithintherequiredlimits.BothtestsshallsatisfythecriteriastipulatedinSections8.5,9.2,10.2,or15.4,asapplicable.InordertosatisfyInelasticRotationinterstorydriftanglerequirements,eachTestSpecimenshallsustaintherequiredrotationinterstorydriftangleforatleastonecompleteloadingcycle.”
PartII,Section6.5c
ChangeEquation6-3asfollows:
1.40bFy/Es
Fy/(2Es)
b (6-3)
PartII,Section13.4
ChangePartII,Section13.4asfollows:
“13.4.Braces
StructuralsteelbracesshallmeettherequirementsforOCBFSCBFinPartISection1413.CompositebracesshallmeettherequirementsforcompositecolumnsinSection13.2.”
PartII,Section13.5
ChangePartII,Section13.5asfollows:
“BracingconnectionsshallmeettherequirementsinSection7andPartISection1413.”
CommentaryPartI,SectionC1
Addthefollowingparagraph:
“Itshouldbenotedthattheseprovisionsweredevelopedspecificallyforbuildings.Theprovisions,therefore,maynotbeapplicable,inwholeorinpart,tonon-buildingstructures.Extrapolationoftheirusetonon-buildingstructuresshouldbedonewithdueconsiderationoftheinherentdifferencesbetweentheresponsecharacteristicsofbuildingsandnon-buildingstructures.”
CommentaryPartI,SectionC4
Replaceallreferencesto“1997NEHRPProvisions(FEMA,1997A)”with“2000NEHRPProvisions(FEMA,2000e)”.
InTableI-C4-1replacethevaluesgivenforIntermediateMomentFrames(IMF)andOrdinaryMomentFrames(OMF)withthefollowing:
BASICSTRUCTURALSYSTEMANDSEISMICFORCERESISTINGSYSTEM
R
Cd
IntermediateMomentFrames(IMF)
4.5
4
OrdinaryMomentFrames(OMF)
3.5
3
CommentaryPartI,SectionC6.2
Addthefollowingtotheendofthissection:
“WhileASTMA709isprimarilyusedinthedesignandconstructionofbridges,itcouldalsobeusedinbuildingconstruction.Writtenasanumbrellaspecification,itsgradesareessentiallytheequivalentofotherapprovedASTMspecifications.Forexample,ASTMA709grade50isessentiallyASTMA572grade50andASTMA709grade50WisessentiallyASTMA588grade50.Thus,ifused,ASTMA709materialshouldbetreatedaswouldthecorrespondingapprovedASTMmaterialgrade.”
CommentaryPartI,SectionC6.3
ChangeItem(3)inthefirstparagraphasfollows:
“…(3)plateelementswiththicknessgreaterthanorequalto21?in.thatarepartoftheSeismicForceResistingSystem,suchastheflangesofbuilt-upgirders.”
CommentaryPartI,SectionC7.3
Changethefirstsentenceofthesecondparagraphofthissectionasfollows:
“ForallweldsusedinprimarymembersandconnectionsintheSeismicForceResistingSystem,weldmetalnotchtoughnessisrequiredintheseProvisions.”
Addthefollowingsentencetotheendofthesecondparagraph:“TheseweldtoughnessrequirementsarenotintendedtoapplytoERWandSAWweldingprocessesusedintheproductionofHSS(ASTMA500)andpipesections(ASTMA53).”
Addthefollowingsentencetotheendofthelastparagraphofthissection:
“TheEngineerofRecordshouldrefertoAWSD1.1forguidanceinestablishingtheacceptancecriteriaforrepairofdiscontinuities.Outsidetheplastichingeregions,AWSD1.1requirementsforrepairofdiscontinuitiesshouldbeapplied.”
CommentaryPartI,SectionC7.4
AddthefollowingnewcommentarySectionC7.4:“C7.4OtherConnections
TheFEMA/SACtestinghasdemonstratedthesensitivityofregionsundergoinglargeinelasticstrainstodiscontinuitiescausedbywelding,rapidchangeofsection,penetrations,orconstructioncausedflaws.Forthisreason,operationsthatcausediscontinuitiesareprohibitedinthecriticalhingingregion.Areaswherecriticalhingingisexpectedincludemomentframehingingzonesasdefined,linkbeamsofEBFs,theendsandthecenterofSCBFbraces,etc.Itshouldbenotedthatyieldlevelstrainsarenotstrictlylimitedtotheplastichingezones(beam-columnjointregionforcoverplateorRBSconnections,e.g.).Cautionshouldalsobeexercisedincreatingdiscontinuitiesintheseregionsaswell.”
CommentaryPartI,SectionC8.3
ReplaceCommentarySectionC8.3withthefollowing:“C8.3ColumnSplices
InelasticanalysesconductedaspartoftheFEMA/SACprogramhavedemonstratedthatthecommonassumptionthatcolumnflexuralstressesinthemid-heightofmoment
framecolumnsarelowisnotnecessarilytrue.Bendingmomentsequaling,orexceeding,theyieldmomentofthecolumnarepossibleatcolumnsplices,evenwhenthesplicesarelocatedasrequiredbySection8.3a.Accordingly,therequirementisgiventhatthenominalflexuralstrengthofthespliceshouldequalorexceedthenominalflexuralstrengthofthesmallercolumn.Itisnotnecessarytoapplyover-strengthfactorsandfactorstotherequirement,sinceitisacomparisonofrelativemembernominalstrengths.
TheexceptionisprovidedtoallowforcaseswheretheEngineerofRecordcandemonstratethatthelargestdemandsthatcanoccuratcolumnsplicesarebelowtheyieldlevel.Inelasticdynamicanalysesarerequiredtojustifyusingthisexception.Inthesecases,theuseofweldedjointsotherthancomplete-joint-penetrationgrooveweldsmaybeused,providedthatstressconcentrationfactors(e.g.estimatedusingafracturemechanicsapproach)generatedbytheproposedjointconfigurationaretakenintoaccount.”
CommentaryPartI,SectionC9.2a
Addthefollowing:
“LimitationsareplacedonpermissibledifferencesbetweenthetestedyieldstrengthandFyeforbeams,columnsandconnectionelements.Itisnotintendedthattheselimitationsbeappliedretroactivelytotheexistingdatabaseofqualificationtests.Rather,theserequirementsareintendedtoapplyforuseinnewqualificationtesting.”
FEMA350,RecommendedSeismicDesignCriteriaforNewSteelMoment-FrameBuildingsincludesrecommendationsfordesignandfabricationofseveraltypesofconnectionswhicharedeemedtobeprequalifiedforuseinSpecialMomentFramesofsteel.TheseconnectiondesignsarebasedonextensivetestingandanalysisperformedbytheSACJointVentureunderaprogra
溫馨提示
- 1. 本站所有資源如無特殊說明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請下載最新的WinRAR軟件解壓。
- 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請聯(lián)系上傳者。文件的所有權(quán)益歸上傳用戶所有。
- 3. 本站RAR壓縮包中若帶圖紙,網(wǎng)頁內(nèi)容里面會有圖紙預覽,若沒有圖紙預覽就沒有圖紙。
- 4. 未經(jīng)權(quán)益所有人同意不得將文件中的內(nèi)容挪作商業(yè)或盈利用途。
- 5. 人人文庫網(wǎng)僅提供信息存儲空間,僅對用戶上傳內(nèi)容的表現(xiàn)方式做保護處理,對用戶上傳分享的文檔內(nèi)容本身不做任何修改或編輯,并不能對任何下載內(nèi)容負責。
- 6. 下載文件中如有侵權(quán)或不適當內(nèi)容,請與我們聯(lián)系,我們立即糾正。
- 7. 本站不保證下載資源的準確性、安全性和完整性, 同時也不承擔用戶因使用這些下載資源對自己和他人造成任何形式的傷害或損失。
最新文檔
- 河南省駐馬店市汝南縣雙語學校、清華園學校2025-2026學年七年級上學期1月期末考試英語試卷(含答案無聽力原文及音頻)
- 廣東省深圳實驗學校2025-2026學年上學期期末九年級數(shù)學試卷(無答案)
- 2025-2026學年統(tǒng)編版語文五年級第一學期期末質(zhì)量檢測練習卷(含答案)
- 五年級下冊數(shù)學期中試卷及答案
- 無菌技術(shù)考試題及答案
- 文獻檢索試題及答案
- 危機公關(guān)題目及答案
- 2023新課程學習總結(jié)五篇
- 2022~2023自考專業(yè)(小學教育)考試題庫及答案解析第43期
- 電氣智能化系統(tǒng)技術(shù)方法
- 術(shù)后鎮(zhèn)痛的護理課件
- 生活化教學研究
- 交易賬戶托管協(xié)議書
- 公務(wù)接待培訓課件
- 正步走教學課件
- 商砼站合伙投資協(xié)議書6篇
- 2024-2025學年浙江省杭州市余杭區(qū)五年級(上)期末數(shù)學試卷
- 化工廠危害因素識別及防范措施
- 桉樹無節(jié)材分等方法
- 新產(chǎn)品設(shè)計與開發(fā)流程
- 2024小型水庫大壩滲透處理技術(shù)導則
評論
0/150
提交評論