已閱讀5頁,還剩23頁未讀, 繼續(xù)免費閱讀
版權(quán)說明:本文檔由用戶提供并上傳,收益歸屬內(nèi)容提供方,若內(nèi)容存在侵權(quán),請進行舉報或認領(lǐng)
文檔簡介
中華人民共和國國家標準次氯酸鈉發(fā)生器(NATIONALSTANDARDOFTHEPEOPLESREPUBLICOFCHINASODIUMHYPOCHLORITEGENERATOR)NATIONALSTANDARDOFTHEPEOPLESREPUBLICOFCHINASODIUMHYPOCHLORITEGENERATORSODIUMHYPOCHLORITEGENERATORGB1217690THEMECONTENTANDSCOPEOFAPPLICATIONTHEPRODUCTCLASSIFICATION,TECHNICALREQUIREMENTS,TESTMETHODSANDINSPECTIONRULESOFTHESODIUMHYPOCHLORITEGENERATORWITHLOWCONCENTRATIONOFSALTWATERBYDIAPHRAGMELECTROLYSISAREPROVIDEDTHISSTANDARDAPPLIESTOWATERDISINFECTION,WASTEWATERTREATMENTANDSANITATIONANDINDUSTRIALPRODUCTIONDEPARTMENTUSEOFTHESODIUMHYPOCHLORITEGENERATOR2REFERENCESTANDARDGB3859SEMICONDUCTORPOWERCONVERTERGB5461EDIBLESALTGB5749SANITARYSTANDARDSFORLIVINGDRINKINGWATERGB5750STANDARDTESTOFLIVINGDRINKINGWATERJB1043CHEMICALANTICORROSIONLOWVOLTAGEELECTRICALAPPLIANCESJB1045CHEMICALGASCORROSIONTESTMETHODFORELECTRICALPRODUCTSJB2759MECHANICALANDELECTRICALPRODUCTSPACKAGINGGENERALTECHNICALCONDITIONS3NOUNANDTERM31ELECTROLYTICCELLINTHEELECTROLYTICLOWCONCENTRATIONSODIUMHYPOCHLORITEGENERATOR,THEDEVICETHATREACTSWITHANELECTROLYTICREACTIONANDSOLUTIONISCALLEDACELLACCORDINGTOTHEOPERATIONMODEANDDIFFERENTREQUIREMENTSOFUSE,THEELECTROLYZERCANADOPTDIFFERENTCHANNELSTRUCTUREANDELECTRODESHAPE32AVAILABLECHLORINECONCENTRATIONCTHECONCETRATIONOFAVAILABLECHLORINETHESTRENGTHOFTHEOXIDATIONCAPACITYOFSODIUMHYPOCHLORITEWASQUANTITATIVELYEXPRESSEDINTHEEFFECTIVECHLORINECONCENTRATIONTHEOXIDATIONCAPACITYOFEACHLITEROFSOLUTIONISEQUIVALENTTOTHEOXIDATIONCAPACITYOFSEVERALGRAMSOFCHLORINEINWATERTHEUNITOFG/LTHEEFFECTIVECHLORINECONCENTRATIONISEQUALTO2TIMESTHECONCENTRATIONOFTHECHLORINEINTHESOLUTIONFOREACH1GOFSODIUMHYPOCHLORITEINSOLUTION,THEEFFECTIVECHLORINEWAS0953G33AVAILABLECHLORINEPRODUCTIONRATEGPRODUCTIONOFAVAILABLECHLORINETHEYIELDOFTHESODIUMHYPOCHLORITEGENERATORISINDICATEDBYTHEEFFECTIVECHLORINEYIELD,WHICHISEQUALTOTHEQUALITYOFTHEEFFECTIVECHLORINEPERHOURGPERHOURWHENTHEEQUIPMENTISWORKINGUNDERRATEDCONDITIONGEFFECTIVECHLORINEYIELDPEREQUATION1GCXQ1FORMULAQFLOWOFSODIUMHYPOCHLORITESOLUTIONPERHOUR,L/H34CURRENTEFFICIENCYNCURRENTEFFICIENCYAFTERACERTAINAMOUNTOFCHARGEHASBEENUSEDINTHEELECTROLYTICTANK,THEACTUALAMOUNTOFTHEEFFECTIVECHLORINEHASBEENCOMPAREDWITHTHATOFTHETHEORETICALPRODUCT,WHICHISCALLEDTHECURRENTEFFICIENCYOFTHECELLACCORDINGTOFARADSELECTROLYSISLAW,ELECTROLYTICCELLEVERY1ATHETHEORETICALPRODUCTOFEFFECTIVECHLORINEIS1323GCURRENTEFFICIENCYISCALCULATEDBYEQUATION2N1323G/IN1002IELECTROLYTICCURRENT,ANSERIESOFELECTRODESSERIES1323THETHEORETICALPRODUCTOFEFFECTIVECHLORINEPERAMPEREHOUR,G/AH35ELECTROLYTICVOLTAGEVTICVOLTAGEWHENTHERATEDSTATEOFTHESODIUMHYPOCHLORITEGENERATORISWORKING,THEDCVOLTAGEAPPLIEDBETWEENTHECATHODEANDTHECATHODEOFTHEELECTROLYZERISCALLEDTHEELECTROLYTICVOLTAGE,UNITVTHEELECTROLYTICVOLTAGEISUSEDTOMULTIPLYTHEELECTROLYTICVOLTAGEOFEACHPAIROFYINANDYANGTOTHESERIESSUCHAS4VX33RATEDELECTROLYTICCURRENTINOMINALTICCURRENTTOMAINTAINTHERATEDYIELDOFTHESODIUMHYPOCHLORITEGENERATOR,THEELECTROLYTICCURRENTTHATFLOWSTHROUGHTHECELLISCALLEDTHERATEDELECTROLYTICCURRENT,UNITAWHENTHEELECTROLYTICCELLOFTHEEQUIPMENTISSUPPLIEDWITHMULTIPLEPAIRSOFPOLESANDPOLES,THERATEDELECTROLYTICCURRENTCANBEMULTIPLIEDBYEACHPAIROFELECTRODES,SUCHAS50ATIMES237CONCENTRATIONOFELECTROLYTESCONCENTRATIONOFLIQUIDSOLUTIONTHESODIUMHYPOCHLORITEGENERATORUSESLOWCONCENTRATIONOFSALTWATERASTHEELECTROLYTETHECONCENTRATIONOFELECTROLYTEISEXPRESSEDINGRAMSOFNACIINEACHLITEROFSOLUTIONG/L38DCPOWERCONSUMPTIONPDCDCPOWERCONSUMPTIONWHENTHESODIUMHYPOCHLORITEGENERATORWORKSUNDERTHERATEDCONDITION,THEDIRECTCURRENTENERGYCONSUMEDBYEACH1KGOFEFFECTIVECHLORINEINTHEELECTROLYTICCELLCANBECALLEDITSDIRECTCURRENTPOWERCONSUMPTIONTHEUNITISKWH/KG,ANDTHEFORMULAISCALCULATEDACCORDINGTOFORMULA3PDCI/GUUI/QC3INTHEFORMULAUELECTROLYTICVOLTAGEVDCIELECTROLYTICCURRENTADCGEFFECTIVECHLORINEYIELDG/HQTHEYIELDOFSODIUMHYDROCHLORIDESOLUTIONL/HCEFFECTIVECHLORINECONCENTRATIONG/LOFSODIUMHYPOCHLORITE39ACPOWERCONSUMPTIONPACPOWERCONSUMPTIONWHENTHESODIUMHYPOCHLORITEGENERATORWORKSUNDERTHERATEDCONDITION,EVERY1KGOFEFFECTIVECHLORINEISGENERATED,THEACPOWERCONSUMEDBYTHEEQUIPMENTISCALLEDITSACPOWERCONSUMPTION,THEUNITISKWH/KG,ANDTHEFORMULAISCALCULATEDACCORDINGTOFORMULA4PP1ACX1000/G4TYPEP1THEWHOLEMACHINEINPUTPOWER,KW310SALTCONSUMPTIONUSSALTCONSUMPTIONWHENTHESODIUMHYPOCHLORITEGENERATORISOPERATINGATRATEDSTATE,THEQUALITYOFNACIFOREVERY1KGOFEFFECTIVECHLORINEPRODUCEDISCALLEDITSSALTCONSUMPTION,ANDTHEUNITISKG/KG,ANDTHEFORMULAISCALCULATEDACCORDINGTOFORMULA5USS/C5INTHEFORMULASELECTROLYTECONCENTRATION,G/LCEFFECTIVECHLORINECONCENTRATION,G/LPRODUCTCLASSIFICATION41CLASSIFICATIONPRINCIPLETHESODIUMHYPOCHLORITEGENERATORISCLASSIFIEDACCORDINGTOUSE,OPERATIONMODE,SPECIFICATIONANDQUALITYGRADE411SODIUMHYPOCHLORITEGENERATORISDIVIDEDINTOTWOCATEGORIESACCORDINGTOUSESANITARYDISINFECTIONANDENVIRONMENTALPROTECTIONSANITARYDISINFECTIONCLASSESCANBEUSEDFORENVIRONMENTALPROTECTIONANDENVIRONMENTALPROTECTIONSHOULDNOTBEUSEDFORSANITIZATIONSANITARYDISINFECTIONCLASSREFERSTOTHESODIUMHYPOCHLORITEGENERATORWHICHISDIRECTLYRELATEDTOHUMANHEALTH,SUCHASDISINFECTION,SANITARYWAREANDTABLEWARESTERILIZATION,VEGETABLE,FRUIT,FOODDISINFECTION,ETCTHEENVIRONMENTALPROTECTIONCLASSREFERSTOTHESODIUMHYPOCHLORITEGENERATORUSEDININDUSTRIALWASTEWATERTREATMENT,HOSPITALSEWAGETREATMENTANDOTHERINDUSTRIALSECTORSWITHNODIRECTRELATIONTOHUMANHEALTHTHEOPERATIONOF412HYPOCHLORITEGENERATORISDIVIDEDINTOTWOTYPESCONTINUOUSOPERATIONANDINTERMITTENTOPERATION413OFTHESPECIFICATIONSOFTHESODIUMHYPOCHLORITEGENERATORACCORDINGTOEQUIPMENTAVAILABLECHLORINEPRODUCTIONRATECANBEDIVIDEDINTO5,10,25,50,75,100,150,200,250,300,400,500,750,1000,1500,2000,3000,5000,G/H,MORETHAN5000G/HSPECIFICATIONSACCORDINGTOACTUALNEEDS414THEQUALITYGRADEOFSODIUMHYPOCHLORITEGENERATORISDIVIDEDINTOTHEBESTQUALITYA,THEFIRSTCLASSBANDTHEQUALITYC42PRODUCTLABELING421THEPRODUCTMARKSOFTHESODIUMHYPOCHLORITEGENERATORAREMADEUPOFTHREEPARTSANDAREARRANGEDINTHEFOLLOWINGORDERPRODUCTNAMETECHNICALCHARACTERISTICSSTANDARDNUMBER422THEPRODUCTNAMESECTIONIS“SODIUMHYPOCHLORITEGENERATOR“423THETECHNICALFEATURESSHALLBECOMPOSEDOFLETTERS,NUMBERS,ETCWHICHINDICATETHEPURPOSE,OPERATIONMODE,SPECIFICATIONANDQUALITYGRADEOFTHEEQUIPMENT4231THEFIRSTCHINESEPINYINLETTERINTHETECHNICALCHARACTERISTICPARTINDICATESTHEPURPOSEOFTHEEQUIPMENTTHELETTERWISUSEDFORSANITIZATIONANDTHELETTERHISUSEDFORENVIRONMENTALPROTECTIONTHESECONDCHINESEPINYINLETTEROFTHETECHNICALCHARACTERISTICSECTIONINDICATESTHEOPERATIONOFTHEEQUIPMENT,CODENAMEDLCONTINUOUSELECTROLYSIS,JINTERMITTENTELECTROLYTICPROTECTION4233THETHIRDARABICNUMERALINTHETECHNICALCHARACTERISTICPARTREPRESENTSTHESPECIFICATIONOFTHEEQUIPMENT,WHICHISTHERATEDRATEOFTHEEQUIPMENT4234THEFOURTHENGLISHLETTERINTHETECHNICALCHARACTERISTICSSECTIONINDICATESTHEQUALITYGRADEOFTHEPRODUCTLETTERAEXCELLENTQUALITY,BONEGRADE,CQUALITYPRODUCTS424THESTANDARDNUMBERINPRODUCTLABELINGSHALLMEANTHATTHEPRODUCTCONFORMSTOTHENATIONALSTANDARDOFTHISITEMINGB1217643PRODUCTLABELINGEXAMPLEFOREXAMPLEFORSANITARYDISINFECTION,CONTINUOUSOPERATION,THERATEDYIELDIS100G/H,ANDTHEQUALITYGRADEOFTHESODIUMHYPOCHLORITEGENERATOR,WHOSEPRODUCTISMARKEDASSODIUMHYPOCHLORITEGENERATORWL100BGB121769044THEQUALITYLEVELMARKSUSEDINTHEPRODUCTMARKSANDTHEMARKSTHATCONFORMTOTHEREQUIREMENTSOFTHENATIONALSTANDARDSHALLBERECOGNIZEDBYTHESTATESPECIALIZEDAGENCIESORDESIGNATEDQUALITYMONITORINGUNITS45THESPECIFICMODELOFTHEPRODUCTALLOWSTHEMANUFACTURERTODETERMINEACCORDINGTOTHEREQUIREMENTSOFTHISSTANDARDTECHNICALREQUIREMENT51ENVIRONMENTALCONDITIONSTHESODIUMHYPOCHLORITEGENERATORSHOULDBEABLETOWORKNORMALLYINTHEFOLLOWINGENVIRONMENT511AMBIENTTEMPERATURE040OCENVIRONMENTHUMIDITYTHEMAXIMUMRELATIVEHUMIDITYINTHEAIRISNOMORETHAN90PERCENTINTHEEQUIVALENTOF20ORMINUS5OCFORAIR513INADDITIONTOTHETECHNICALREQUIREMENTSOFTHEIRRESPECTIVEPRODUCTS,THELOWVOLTAGEELECTRICALAPPLIANCESSELECTEDONTHEQUALITYGRADEOFTHESODIUMHYPOCHLORITEGENERATORSHALLCONFORMTOTHEREQUIREMENTSOFJB104352BASICTECHNICALREQUIREMENTS521SODIUMHYPOCHLORITEGENERATORSHALLBEMANUFACTUREDACCORDINGTOTHEDRAWINGSANDTECHNICALDOCUMENTSAPPROVEDBYTHEPROCEDURE522THESPECIFICATIONOFSODIUMHYPOCHLORITEGENERATORSHALLMEETTHEREQUIREMENTSOF413OFTHISSTANDARD523THESUBCHLORITEGENERATORSHALLBEDIVIDEDINTOAQUALITYGRADEACCORDINGTOTHEPROVISIONSOFARTICLE54OFTHISSTANDARD,WHICHSHALLMEETTHEREQUIREMENTSOFTHEINDEXESINTHISGRADE524THESODIUMHYPOCHLORITEGENERATORMUSTHAVETHEGROUNDINGBOLTSOFTHESHELL,THEPARTSOFTHESHELLANDTHEMETALSTRUCTUREPARTSOFTHEPOWERSOURCEANDTHEGROUNDINGBOLTSHAVERELIABLEELECTRICALCONNECTIONSTHEMEASUREDVALUEOFTHECOUPLINGRESISTANCEISLESSTHAN01GROUNDINGBOLTSSHALLBEMARKEDWITHANOBVIOUSEARTHINGMARK525THEELECTROLYZERANDSTORAGETANKUSEDFORTHEEQUIPMENTWITHAYIELDOFMORETHAN25G/HMUSTBEENCLOSEDANDSETWITHTHESTANDARDINTERFACETOTHEOUTDOOREXHAUSTPIPE526THEPRODUCTIONRATEISGREATERTHAN25G/HEQUIPMENTANDSHALLHAVEANINTERCONNECTIONSTANDARDINTERFACECONNECTEDWITHTHEATTACHEDBRINEDISTRIBUTIONDEVICEANDTHEINJECTIONDEVICE52ADEVICEWITHAYIELDOFMORETHAN25G/HMUSTBEEQUIPPEDWITHANELECTROLYTICCURRENTANDANELECTROLYTICVOLTAGEMONITORINGINSTRUMENTWITHANACCURACYOFNOLESSTHAN25THECONTINUOUSRUNNINGEQUIPMENTMUSTBEEQUIPPEDWITHTHEELECTROLYTEFLOWMETERINGMETER,ANDTHEEQUIPMENTOFTHEINTERMITTENTOPERATIONMUSTBEINTHEELECTROLYTICTANKORINTHECIRCULATINGSLOTONTHEEQUIPMENTLEVELMETER528THEPHYSICALANDCHEMICALPROPERTIESOFSODIUMHYPOCHLORITESOLUTIONAREREQUIRED5281SODIUMHYPOCHLORITESOLUTIONSHOULDBECLEARANDTRANSPARENTNOIMPURITIESCANBEFOUND5282THECONTENTOFHEAVYMETALIONCHROMIUMANDLEADINSODIUMHYPOCHLORITESOLUTIONPRODUCEDBYSANITIZINGSODIUMHYPOCHLORITEGENERATORSHALLCONFORMTOTHERELEVANTPROVISIONSOFCHAPTER2WATERQUALITYSTANDARDSANDHYGIENICREQUIREMENTSOFGB57495283THESODIUMHYPOCHLORITEGENERATORFORSANITARYDISINFECTIONSHALLNOTBEUSEDINTHEGRAPHITEELECTRODEANDLEADCOATINGANODE53OPERATIONPARAMETERSANDPERFORMANCEOFSODIUMHYPOCHLORITEGENERATOR531POWERSUPPLYTHEINPUTPOWEROFSODIUMHYPOCHLORITEGENERATORSHALLBEAC220V/380V10FOR50HZPLUSORMINUS5532THERANGEOFELECTROLYTICCURRENTSHOULDBEMORETHAN10OFTHERATEDELECTROLYTICCURRENT533SODIUMHYPOCHLORITEGENERATORSHOULDBEABLETOENSURETHERATEDYIELDOFTHEEQUIPMENTINTHELONGTERMWORKINGCONDITION,ANDBEABLETOEXCEED10OFTHEPRODUCTIONRATEFOR1H534THECONCENTRATIONRANGEOFELECTROLYTERECOMMENDEDBYTHEEQUIPMENTIS3050G/LTHEENTIREPROCESSOFTHEEQUIPMENTPERFORMANCETESTSHOULDADOPTTHEFIXEDCONCENTRATIONOFELECTROLYTESELECTEDINTHISRANGE535THELIQUIDCONSUMPTIONOFELECTROLYTEISEXPRESSEDINTHECELLOFACONTINUOUSWORKINGCELLWITHELECTROLYTEPERHOUR,ANDTHEUNITL/HTHESALTWATERCONSUMPTIONANDTHEELECTROLYTICCYCLEHOFEACHELECTROLYTICCYCLEINTHEINTERMITTENTELECTROLYTICCELLAREEXPRESSEDASTHEUNITL/H,SUCHAS50L/15H536THEPRODUCTSHALLINDICATETHEDIMENSIONS,WEIGHTANDINSTALLATIONDIMENSIONSOFTHEEQUIPMENTANDAUXILIARYEQUIPMENTWATERDISINFECTIONANDSEWAGETREATMENTSHOULDBEPROVIDEDWITHASCHEMATICDIAGRAMOFINSTALLATION537THEEQUIPMENTSHOULDENSURETHATTHEELECTROLYTEISLESSTHAN40OCINTHEELECTROLYSISPROCESS,ANDCORRESPONDINGCOOLINGMEASURESSHOULDBETAKENWHENNECESSARYTECHNICALECONOMICINDICATORSANDQUALITYSCORESTABLE1TABLE1TECHNICALANDECONOMICINDICATORSANDQUALITYANALYSISTECHNOLOGYECONOMICINDICATORSUNITQUALITYGRADEABC63VISUALINSPECTION521527AND55APPEARANCEREQUIREMENTSOF52BASICTECHNICALREQUIREMENTSINTHISSTANDARDSHALLBEUSEDFORVISUALINSPECTION64THETESTMETHODFORTHEVOLTAGEWITHSTANDTESTANDINSULATIONRESISTANCEMEASUREMENTOFTHEELECTROLYTICPOWERSUPPLYSHOULDCONFORMTOTHERELEVANTPROVISIONSINGB3859THETEMPERATURERISETESTMETHODOFTHEELECTROLYTICPOWERSUPPLYCANBECARRIEDOUTINACCORDANCEWITHTHERELEVANTPROVISIONSOFGB3859THETEMPERATURERISETESTCANBECARRIEDOUTSIMULTANEOUSLYWITHTHECONTINUOUSOPERATION66THEELECTRICALOPERATIONTESTOFSODIUMCHLORATEGENERATORTOCHECKTHEWORKINGSTATEOFEQUIPMENTANDTHERANGEOFELECTROLYTICCURRENTADJUSTMENT661TESTBEFORECHECKINGCIRCUITACCORDINGTOTHEREQUIREMENTSOFDRAWINGSANDPIPEASSEMBLY,CHECKAFTERTHENORMALCONNECTEDBRINEPIPELINE,ACCORDINGTOTHESYSTEMRATEDFILLINGLIQUIDELECTROLYTE,EACHPARTSHOULDWORKNORMALLY,ANDNOLEAKAGE662CONNECTTHEPOWERCIRCUITOFTHEEQUIPMENT,ADJUSTTHEELECTROLYTICCURRENTTOTHERATING,ANDTHEELECTROLYSIS30MINEQUIPMENTSHOULDWORKNORMALLY663WHENTHECURRENTCONTROLDEVICEOFTHEELECTROLYTICCURRENTCONTROLISRATEDAT10,THEOUTPUTELECTROLYTICCURRENTSHOULDBEADJUSTEDTOTHERATINGVALUEPLUS10,ANDTHEPOWERSUPPLYPRESSURERATINGOF10,THEELECTROLYTICCURRENTSHOULDBEADJUSTEDTOTHERATING10INTHETEST,THEINPUTVOLTAGEISALLOWEDTOCHANGETHEINPUTVOLTAGEVALUETHETESTRESULTSSHOULDMEETTHEREQUIREMENTSOF532AND5611OFTHISSTANDARD664AFTERTHETEST,THEELECTROLYTICTANKANDTHELIQUIDSTORAGETANKSHALLBEEMPTIEDANDTHETIMEOFDISCHARGESHALLBERECORDEDINACCORDANCEWITHTHEREQUIREMENTSOF573AND5104OFTHISSTANDARD67CONTINUOUSOPERATIONTESTELECTROLYTICVOLTAGE,RATEDYIELD,CURRENTEFFICIENCY,DCPOWERCONSUMPTION,ACPOWERCONSUMPTION,SALTCONSUMPTION,WHOLEMACHINEINPUTPOWER,ELECTROLYTETEMPERATURERISEANDELECTROLYTICPOWERTEMPERATURERISETEST671TESTMETHODWITHTHESUBJECTSOFSODIUMHYPOCHLORITEGENERATORUNDERRATEDWORKINGCONDITIONASSTIPULATEDINARTICLE672CONTINUOUSWORK,RECORDINTHEPROCESSOFOPERATIONASSHOWNINARTICLE674OFVARIOUSOPERATINGPARAMETERS,ANDTHEFORMULATOCALCULATETHEPARAMETERSACCORDINGTOTHERULES672CONTINUOUSRUNNINGTESTRATEDWORKINGCONDITION6721THEELECTROLYTEUSEDINTHETESTSHALLMEETTHEFOLLOWINGREQUIREMENTSATHEELECTROLYTEISPREPAREDWITHREFINEDSALTANDWATERTHEREFINEDSALTSHOULDMEETTHEREQUIREMENTSOFREFINEDSALTINGB5461WATERQUALITYSHOULDMEETGB5749STANDARDOFDRINKINGWATERBTHEVARIATIONRANGEOFTHECONCENTRATIONANDCONCENTRATIONOFTHEELECTROLYTEINTHETESTSHALLMEETTHEREQUIREMENTSOF593OFTHISSTANDARDCTHEELECTROLYTETEMPERATUREOFTHEINPUTCELLINTHETESTSHALLBE205OCDTHEDISCHARGEOFTHEELECTROLYTEINTHETESTSHOULDMAINTAINTHERATINGFORCONTINUOUSOPERATION,THEFLOWRATESHOULDBELESSTHAN5ORMINUS5FORINTERMITTENTOPERATION,THEELECTROLYTEINJECTIONANDELECTROLYTICTIMESHOULDBEMAINTAINED6722THEELECTROLYTICCURRENTINTHETESTSHOULDMAINTAINTHERATING,ANDTHEDEVIATIONSHOULDBELESSTHANORMINUS25ITISALLOWEDTOINCREASETHEVOLTAGESTABILIZERORTHEREGULATINGDEVICEONTHEPOWERINPUT673CONTINUOUSELECTROLYTICCELLOPERATIONTIMEWILLBEUSEDTOSTABILIZETHEEQUIPMENTANDTHE4HINTERMITTENTCELLSHOULDWORK4ELECTROLYTICCYCLES674OPERATIONDATARECORDCONTINUOUSELECTROLYSISINRUNNINGEVERY05H,INTERMITTENTELECTROLYSIS,THEBEGINNINGANDTHEENDOFEACHCYCLEOFELECTROLYTICSHALLBETRUTHFULLYRECORDEDDATASUCHASRUNELECTROLYTICTIME,INPUTPOWERSUPPLYVOLTAGE,THEINPUTPOWERSUPPLYCURRENT,ELECTROLYTICVOLTAGE,ELECTROLYTICCURRENT,THEELECTROLYTEFLOWRATECAPACITYELECTROLYTE,ELECTROLYTECONCENTRATION,SODIUMHYPOCHLORITESOLUTIONFLOWRATE,ACTIVECHLORINECONTENTINSODIUMHYPOCHLORITESOLUTION,THEELECTRICALCONTACTTEMPERATURE,ELECTROLYTETEMPERATURE,SODIUMHYPOCHLORITESOLUTIONTEMPERATURE,ENVIRONMENTTEMPERATURE,THEEXPERIMENTERSIGNATUREANDSOONWHENRECORDINGTHEINSTRUMENTDISPLAYDATA,THELABORATORYINSTRUMENTINSTALLEDINTHETESTSHALLBERECORDEDATTHESAMETIME675TESTINSTRUMENTTHEACCURACYOFTHELABORATORYINSTRUMENTUSEDINTHETESTSHALLBENOLESSTHAN05,ANDTHERESOLUTIONOFTHETHERMOMETERSHALLBE02OC676CONTINUOUSCELLINTHEEXPERIMENTSSODIUMHYPOCHLORITESOLUTIONFLOWRATEQ,THEMEASURINGCYLINDERANDASTOPWATCH,CALCULATEDUSINGTHEMETHODOFVOLUMEDIVIDEDBYTHETIME,EVERYSAMPLINGFLOWPARAMETERSSHOULDBEMORETHAN3TIMES,EACHTIMESAMPLINGTIMENOTLESSTHAN1MIN,ANDTHEAVERAGEMEASUREMENTAFEWTIMES677CALCULATIONOFEFFECTIVECHLORINEYIELDFORCONTINUOUSOPERATIONOFTHESODIUMHYPOCHLORITEGENERATOR,AVAILABLECHLORINEYIELDCALCULATIONACCORDINGTOTHEARTICLE33OFTHISSTANDARDINTHEFORMULA1CALCULATION,CALCULATIONWHENSODIUMHYPOCHLORITESOLUTIONFLOWRATEQRUNNINGTESTOFTHETIMEANDTHEMEANOFTHEFLOWOFSODIUMHYPOCHLORITESOLUTION,THECONCENTRATIONOFAVAILABLECHLORINEC,ALSOTAKETHETIMEANDTHEMEANOFTHECONCENTRATIONOFAVAILABLECHLORINEFORINTERMITTENTMOTIONOFSODIUMHYPOCHLORITEGENERATOR,EACHCYCLEOFELECTROLYTICSALTWATERCONSUMPTIONINELECTROLYTICLIQUIDPRODUCTDIVIDEDBYTHEELECTROLYTICTIME,ANDACCORDINGTOTHEFORMULA1TOCOMPUTEEACHCYCLEOFAVAILABLECHLORINEPRODUCTIONRATE,ACTIVECHLORINEYIELDOFSUBJECTSWHICHSHOULDBETAKESEVERALCYCLESOFELECTROLYTICMEASUREDACTIVECHLORINEYIELDAVERAGE678CURRENTEFFICIENCYNCALCULATIONACCORDINGTOTHEMEANOFTHEMEASUREDYIELDGANDTHEELECTROLYTICCURRENTOFTHECONTINUOUSOPERATIONTEST,THECALCULATIONOFTHEAVERAGEVALUEOFTHEELECTRICCURRENTISCALCULATEDACCORDINGTOTHEFORMULA2OFTHISSTANDARD679DCPOWERCONSUMPTIONCALCULATIONACCORDINGTOTHEMEANOFELECTROLYTICVOLTAGE,ELECTROLYTICCURRENTANDEFFECTIVECHLORINEYIELDINTHECONTINUOUSOPERATIONEXPERIMENT,THEAVERAGEVALUEOFCHLORINEYIELDISCALCULATEDACCORDINGTOFORMULA3IN386710CALCULATIONOFACPOWERCONSUMPTIONTESTRESULTSACCORDINGTOTHEAVERAGEVALUEOFACINPUTPOWEROBTAINEDINTHECONTINUOUSRUNNINGTESTANDTHEAVERAGEVALUEOFTHERATEDYIELDISCALCULATEDACCORDINGTO39FORMULA46711MACHINEINPUTPOWERPITESTSWHICHCANBEUNDERRATEDOPERATINGCONDITIONWITHACERTAINTIMEEQUIPMENTPOWERSUPPLYINTOTHEONLINEINSTALLATIONOFELECTRICITYMETERMEASUREMENTCALCULATEDVALUESDIVIDEDBYTHEELECTROLYSISTIME,ALSOCANUSEWATTMETERDIRECTLYMEASURED,UNITKW6712ELECTROLYTETEMPERATURERISEFORTHECONTINUOUSOPERATIONOFTHEELECTROLYTE,THETEMPERATUREOFTHEELECTROLYTEOUTLETTEMPERATUREOFTHESODIUMHYPOCHLORITEATTHEENDOFTHECONTINUOUSRUNNINGTESTISUSEDTOREDUCETHEINLETTEMPERATUREOFTHEELECTROLYTE,ANDTHEUNITISOCFORTHEINTERMITTENTOPERATIONOFTHEELECTROLYTICCELL,THEELECTROLYTETEMPERATUREATTHEBEGINNINGOFTHEELECTROLYSISOFTHEELECTROLYTE,MINUSTHEELECTROLYTETEMPERATUREATTHEBEGINNINGOFELECTROLYSIS,ISTHEUNITOFOC6713ELECTRICALCONTACTTEMPERATURERISEINTHESTEADYSTATEOPERATIONOFEQUIPMENT,WHENTHETESTINGPOINTOFTEMPERATURECHANGEISLESSTHAN1OC/H,CONTACTTEMPERATUREANDENVIRONMENTALTEMPERATUREFORTHERISEOFTEMPERATUREOFTHEPOINT,THEDIFFERENCEBETWEENTHEELECTRICALCONTACTTEMPERATUREMEASUREMENTUSINGSEMICONDUCTORTHERMOMETER,AMBIENTTEMPERATUREMEASUREDBYMORETHANTWOGLASSTHERMOMETER,THE1MFARFROMTHEEQUIPMENTINSTALLATION,THEPOSITIONOFTHEHEIGHTOF1MTHEAMBIENTTEMPERATUREINTHETEMPERATURERISETESTISWITHINTHERANGEOF1040OC,ANDTHEENVIRONMENTSHOULDNOTBEAFFECTEDBYTHETEMPERATURERISETEST6714THEDISPLAYVALUEOFTHEINSTRUMENTONTHEEQUIPMENTINTHETESTSHALLBELESSTHAN25PERCENTOFTHEDISPLAYVALUEOFTHE05LEVELINSTRUMENT68OVERLOADTESTOVERLOADTESTINCONTINUOUSWORKAFTERTHETEST,THETESTSHOULDBEKEEPTHEELECTROLYTICCURRENTANDTHEELECTROLYTEFLOWRESPECTIVELYTHEIRRATINGOF110,THEOVERLOADTESTTIMEOF1H,THEEQUIPMENTSHOULDBEWORKINGPROPERLY,COMPONENTSNODAMAGE,INCONFORMITYWITHTHERELEVANTPROVISIONSOFTHEARTICLE533OFTHISSTANDARDTHECUMULATIVEWORKINGTIMETESTOFTHENONWASHINGELECTRODEOFSODIUMCHLORATEGENERATORWASCONDUCTED691MADEBYTESTEQUIPMENTINTHESTANDARDNOMINALWORKINGCONDITIONASSTIPULATEDINARTICLE672WORK,TESTOFELECTROLYTESHOULDCONFORMTOTHEREQUIREMENTSOFTHEARTICLE6721,BUTTHEUSEOFWATERTOTALHARDNESSC
溫馨提示
- 1. 本站所有資源如無特殊說明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請下載最新的WinRAR軟件解壓。
- 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請聯(lián)系上傳者。文件的所有權(quán)益歸上傳用戶所有。
- 3. 本站RAR壓縮包中若帶圖紙,網(wǎng)頁內(nèi)容里面會有圖紙預(yù)覽,若沒有圖紙預(yù)覽就沒有圖紙。
- 4. 未經(jīng)權(quán)益所有人同意不得將文件中的內(nèi)容挪作商業(yè)或盈利用途。
- 5. 人人文庫網(wǎng)僅提供信息存儲空間,僅對用戶上傳內(nèi)容的表現(xiàn)方式做保護處理,對用戶上傳分享的文檔內(nèi)容本身不做任何修改或編輯,并不能對任何下載內(nèi)容負責。
- 6. 下載文件中如有侵權(quán)或不適當內(nèi)容,請與我們聯(lián)系,我們立即糾正。
- 7. 本站不保證下載資源的準確性、安全性和完整性, 同時也不承擔用戶因使用這些下載資源對自己和他人造成任何形式的傷害或損失。
最新文檔
- 2024年西安外事學院馬克思主義基本原理概論期末考試題帶答案解析(必刷)
- 2025年貴州傳媒職業(yè)學院馬克思主義基本原理概論期末考試模擬題含答案解析(必刷)
- 2025年華東政法大學單招職業(yè)適應(yīng)性測試題庫帶答案解析
- 2025年竹山縣招教考試備考題庫含答案解析(必刷)
- 2025年互助縣招教考試備考題庫及答案解析(奪冠)
- 2025年海南經(jīng)貿(mào)職業(yè)技術(shù)學院馬克思主義基本原理概論期末考試模擬題及答案解析(必刷)
- 2025年江西機電職業(yè)技術(shù)學院單招職業(yè)傾向性考試題庫附答案解析
- 2025年廈門興才職業(yè)技術(shù)學院馬克思主義基本原理概論期末考試模擬題及答案解析(奪冠)
- 2026年伊犁職業(yè)技術(shù)學院單招職業(yè)技能考試題庫附答案解析
- 2026年云南外事外語職業(yè)學院單招職業(yè)適應(yīng)性考試模擬測試卷帶答案解析
- 華為完整版本
- 心血管-腎臟-代謝綜合征(CKM)綜合管理中國專家共識2025解讀課件
- 八年級英語下冊集體備課教案:Unit 8 Have you read Treasure Island yet P1
- (一模)太原市2025年高三年級模擬考試(一)英語試卷(含標準答案)
- DB31-T 1433-2023 揚塵在線監(jiān)測技術(shù)規(guī)范
- 加油站應(yīng)急救援知識培訓
- 非財務(wù)人員的財務(wù)管理培訓通用課件
- 安全生產(chǎn)標準化績效考核評定報告
- 安徽永牧機械集團有限公司年產(chǎn)10000噸鋼結(jié)構(gòu)加工項目環(huán)境影響報告表
- 就業(yè)單位提前退休申請書
- QSY136-2023年生產(chǎn)作業(yè)現(xiàn)場應(yīng)急物資配備選用指南
評論
0/150
提交評論