醫(yī)院外科綜合樓_第1頁(yè)
醫(yī)院外科綜合樓_第2頁(yè)
醫(yī)院外科綜合樓_第3頁(yè)
醫(yī)院外科綜合樓_第4頁(yè)
醫(yī)院外科綜合樓_第5頁(yè)
已閱讀5頁(yè),還剩38頁(yè)未讀 繼續(xù)免費(fèi)閱讀

下載本文檔

版權(quán)說(shuō)明:本文檔由用戶提供并上傳,收益歸屬內(nèi)容提供方,若內(nèi)容存在侵權(quán),請(qǐng)進(jìn)行舉報(bào)或認(rèn)領(lǐng)

文檔簡(jiǎn)介

*******醫(yī)院外科綜合樓初步設(shè)計(jì)說(shuō)明1.總說(shuō)明1.1設(shè)計(jì)依據(jù)國(guó)家有關(guān)規(guī)范、標(biāo)準(zhǔn)《綜合醫(yī)院建筑設(shè)計(jì)規(guī)范》JGJ49-88《綜合醫(yī)療建設(shè)標(biāo)準(zhǔn)》建標(biāo)110-2008《醫(yī)院潔凈手術(shù)部建筑技術(shù)規(guī)范》GB50333-2002其它相關(guān)國(guó)家、地方法規(guī)規(guī)范。關(guān)于*****醫(yī)院外科綜合大樓建設(shè)項(xiàng)目立項(xiàng)的批復(fù)(*發(fā)改投資[2012]26號(hào))關(guān)于**市*****醫(yī)院外科綜合大樓立項(xiàng)的批復(fù)(*發(fā)改社會(huì)[2012]126號(hào))*****醫(yī)院外科綜合大樓建設(shè)項(xiàng)目可行性研究報(bào)告關(guān)于*****醫(yī)院外科綜合大樓建設(shè)項(xiàng)目可行性研究報(bào)告的批復(fù)(*發(fā)改社會(huì)〔2012〕795號(hào))***住房和城鄉(xiāng)規(guī)劃建設(shè)委員會(huì)對(duì)總*規(guī)劃方案批復(fù)*****醫(yī)院基建辦編制的外科綜合大樓設(shè)計(jì)任務(wù)書*****醫(yī)院提供的院區(qū)地形圖*****醫(yī)院外科大樓巖土工程勘察報(bào)告*****醫(yī)院和****建筑設(shè)計(jì)院有限公司(廣西分公司)簽訂的設(shè)計(jì)委托書環(huán)境影響報(bào)告書關(guān)于*****醫(yī)院外科綜合大樓及輔助用房項(xiàng)目環(huán)境影響報(bào)告書的批復(fù)(*環(huán)審〔2013〕1號(hào))1.1.13***地震局準(zhǔn)予行政許可決定書(*震許決字〔2013〕第3號(hào))1.1.14*****政府常務(wù)會(huì)議紀(jì)要(十五屆第4期)(詳見附件,所缺部分由建設(shè)單位補(bǔ)缺齊)1.2院區(qū)概況*****醫(yī)院外科綜合大樓位置該項(xiàng)目為*****醫(yī)院外科綜合樓,位于***城瑞雁大道和瑞雁大道交叉處,*****醫(yī)院大院(新院址)內(nèi)。院區(qū)建設(shè)場(chǎng)地地質(zhì)、氣候條件***位于廣西東南部,黃金水道西江上游,居北緯23°2'19〃一24°2'19〃,東經(jīng)110°3,54〃一110°39,42〃,屬南亞熱帶季風(fēng)氣候。全年氣候溫和,年*均氣溫21.5°C,年降雨量1630毫米,年*均日照1712小時(shí),主導(dǎo)風(fēng)向?yàn)闁|南方。***內(nèi)河流屬珠江流域西江水系,西江橫貫縣之中部*原,境內(nèi)全長(zhǎng)44公里,多年*均徑流量為1828億立方米,主要河流有15條,集雨面積2987.73*方公里,多年*均徑流量25.4億立方米,全縣雨量充沛,水能蘊(yùn)量8.41萬(wàn)KW。全縣建設(shè)有大、中、小型水庫(kù)55座,其中大型1座,中型3座,水庫(kù)儲(chǔ)水量達(dá)5億多立方米。市政條件生活用水由市政給水直接供給。污水經(jīng)醫(yī)院的污水處理站處理后排入市政污水檢查井。雨水經(jīng)室外雨水溝收集后排至市政雨水檢查井。本工程電源電壓等級(jí)為220?380V,由本院內(nèi)的配電室引來(lái)。有線電視、電話及網(wǎng)絡(luò)系統(tǒng)的進(jìn)線均由相關(guān)的城市網(wǎng)絡(luò)引接,系統(tǒng)由甲方委托專業(yè)公司設(shè)計(jì),本設(shè)計(jì)僅為系統(tǒng)的管路敷設(shè)。醫(yī)院建設(shè)規(guī)模與任務(wù)擬建的外科綜合樓屬于*****醫(yī)院的醫(yī)療設(shè)施。*****醫(yī)院是一所集醫(yī)療、教學(xué)、預(yù)防保健、康復(fù)為一體的國(guó)家二級(jí)甲等綜合性醫(yī)院及國(guó)家級(jí)愛嬰醫(yī)院,是***120急救中心和孕產(chǎn)婦急救中心,是******第一附屬醫(yī)院技術(shù)協(xié)作醫(yī)院,是***轄區(qū)內(nèi)醫(yī)療業(yè)務(wù)技術(shù)最全面、醫(yī)療設(shè)備最完善、醫(yī)療服務(wù)能力最強(qiáng)的公益性綜合醫(yī)院。現(xiàn)有20個(gè)臨床科室、12個(gè)醫(yī)技科室。現(xiàn)有在職職工910多人,中級(jí)以上職稱技術(shù)人員325多人,其中高級(jí)專業(yè)技術(shù)人員24人,研究生學(xué)歷醫(yī)務(wù)人員9人?,F(xiàn)有開放病床近900張,年門急診量近36.2萬(wàn)人次,住院病人4.2萬(wàn)人次。根據(jù)工程規(guī)劃設(shè)計(jì)任務(wù)書要求,外科綜合樓建設(shè)規(guī)模:項(xiàng)目基底面積1543.30*方米,使用內(nèi)容包括:地下車庫(kù)、供應(yīng)中心、產(chǎn)科、產(chǎn)房、新生兒科、手術(shù)部、ICU、住院部,總建筑面積33901.68*方米,總病床數(shù)588床。設(shè)計(jì)范圍本次設(shè)計(jì)包括外科綜合樓的單體設(shè)計(jì)。外科綜合樓二次裝修由業(yè)主另行委托裝修公司進(jìn)行。設(shè)計(jì)指導(dǎo)思想和設(shè)計(jì)特點(diǎn)1.4.1外科綜合樓用地位于*****醫(yī)院大院(新院址)內(nèi)中心位置,南偏東面是急救中心及辦公綜合樓(在建),南偏西面是業(yè)務(wù)綜合樓(已建成),西面是康復(fù)治療用房(規(guī)劃中),北面是教學(xué)科研樓(規(guī)劃中)??傮w布局要求功能分區(qū)明確,與周邊新舊建筑銜接合理,使用流線通暢。1.4.2病房樓流程設(shè)計(jì)、醫(yī)療手段和設(shè)備選用方面盡量做到技術(shù)先進(jìn)經(jīng)濟(jì)合理,體現(xiàn)現(xiàn)代化醫(yī)療設(shè)施的特點(diǎn)。1.4.3病房樓建筑*面布局考慮潔污分區(qū)、潔污分流的衛(wèi)生要求,注意運(yùn)行路線短捷,管線經(jīng)濟(jì)合理的工程技術(shù)要求。1.4.4在建筑內(nèi)外環(huán)境設(shè)施上努力為病人創(chuàng)造優(yōu)美舒適的就醫(yī)條件,同時(shí)又為醫(yī)務(wù)工作者提供安全方便的工作環(huán)境。1.4.5按照《公共建筑節(jié)能設(shè)計(jì)標(biāo)準(zhǔn)》 GE50189-2005、《廣西公共建筑節(jié)能設(shè)計(jì)規(guī)范》DBJ45/003-2012要求,外科綜合樓按公共建筑熱工要求和地方節(jié)能標(biāo)準(zhǔn)做節(jié)能設(shè)計(jì)。各專業(yè)機(jī)房布置盡量縮短管線,減少能耗,設(shè)備選型、系統(tǒng)設(shè)計(jì)、計(jì)量方式盡量考慮節(jié)約能源;并建設(shè)自動(dòng)化管理系統(tǒng)和加強(qiáng)管理以滿足節(jié)能要求。總指標(biāo)1.5.1醫(yī)院大院指標(biāo)醫(yī)院總用地面積40229.69公頃1.5.2外科綜合樓指標(biāo)基底面積:1543.30*方米總建筑面積:33901.68*方米(其中:地下3464.66*方米,地上30437.02*方米)病床數(shù):588床用電設(shè)備安裝總?cè)萘浚?708.92KW日用水量:443.30立方/天空調(diào)計(jì)算冷負(fù)荷:3400KW總用鋼量:2850噸項(xiàng)目總投資:14500萬(wàn)元(資金來(lái)源全部由建設(shè)單位自籌解決)存在問題及建議1.6.1在施工圖設(shè)計(jì)之前,應(yīng)和醫(yī)療設(shè)備公司進(jìn)行溝通,以確認(rèn)*面布置是否滿足安裝要求。1.6.2在施工圖設(shè)計(jì)之前,應(yīng)和太陽(yáng)能或空氣能廠家進(jìn)行溝通,以解決屋頂機(jī)房布置。2?總*面2.1設(shè)計(jì)依據(jù)2.1.1***住房和城鄉(xiāng)規(guī)劃建設(shè)委員會(huì)對(duì)總*規(guī)劃方案批復(fù)2.1.2*****醫(yī)院提供的院區(qū)地形圖2.2院區(qū)概況2.2.1院區(qū)位置*****醫(yī)院位于***城瑞雁大道和瑞雁大道交叉處,*****醫(yī)院大院(新院址)內(nèi)。東北面臨近***公安局,東南面為已建成商住區(qū)。2.2.2工程用地現(xiàn)狀外科綜合樓用地位于*****醫(yī)院大院(新院址)內(nèi),南偏東面是急救中心及辦公綜合樓(在建),南偏西面是業(yè)務(wù)綜合樓(已建成),西面是康復(fù)治療用房(規(guī)劃中),北面是教學(xué)科研樓(規(guī)劃中)。2.2.3外科綜合樓采用的坐標(biāo)系統(tǒng)及高程系統(tǒng)與地形圖中所采取的一致。2.3 總*面圖2.3.1總*面布置外科綜合樓用地位于*****醫(yī)院大院(新院址)內(nèi),急救中心及辦公綜合樓、業(yè)務(wù)綜合樓、康復(fù)治療用房及教學(xué)科研樓圍合之處;根據(jù)周邊環(huán)境及院方要求,主要人流出入口設(shè)在建筑的西南角;地下車庫(kù)的主要出入口設(shè)在建筑的東南角,為及時(shí)疏散車輛,在地下室的北側(cè)加設(shè)機(jī)動(dòng)車出入口。外科綜合樓污物出口設(shè)在建筑的東北角,較為隱蔽,避免與人流交叉。建筑與南偏西面的業(yè)務(wù)綜合樓(已建成),西面的康復(fù)治療用房(規(guī)劃中)連接。2.3.2豎向布置與道路根據(jù)周圍環(huán)境確定建筑物一層標(biāo)高;外科綜合樓一至三層與康復(fù)治療用房(規(guī)劃中)通過(guò)連廊連接,與南偏西面的業(yè)務(wù)綜合樓(已建成)通過(guò)斜坡連接。在外科綜合樓三面布置環(huán)行車道,與消防車通道結(jié)合。場(chǎng)地雨水采用有組織排水;地下室頂板(室外部分)做出1%坡度,往南北兩側(cè)排水。2.3.3綠化、美化布置在有限的條件下最大限度增加綠化,提供急救中心一個(gè)舒適的環(huán)境。建筑西北處的廣場(chǎng)經(jīng)過(guò)綠化設(shè)計(jì),可以放大綠化空間,弱化建筑物對(duì)環(huán)境的壓迫;通過(guò)綠化空間的收放,勾畫出視線的多層次感,豐富了休息場(chǎng)所的環(huán)境感覺。屋頂綠化是另一個(gè)有效措施,提供了可以遠(yuǎn)眺的休息場(chǎng)所。地下室頂板(室外部分)布置樹池、花壇、草坪、及雕塑小品,可供病人活動(dòng)。3.建筑設(shè)計(jì)依據(jù)及設(shè)計(jì)要求3.1.1根據(jù)*****醫(yī)院的設(shè)計(jì)任務(wù)書,外科綜合樓的建筑設(shè)計(jì)要求先進(jìn)、合理、經(jīng)濟(jì)、實(shí)用,體現(xiàn)現(xiàn)代化醫(yī)療建筑的水*,構(gòu)建和諧的醫(yī)患關(guān)系,為患者提供優(yōu)質(zhì)、高效、價(jià)廉、誠(chéng)信、方便的服務(wù)。3.1.2國(guó)家相關(guān)規(guī)范與標(biāo)準(zhǔn)《民用建筑設(shè)計(jì)通則》GB50352-2005《高層民用建筑設(shè)計(jì)防火規(guī)范》GB50045—95(2005版)《汽車庫(kù)、修車庫(kù)、停車場(chǎng)設(shè)計(jì)防火規(guī)范》GB50067-97《建筑內(nèi)部裝修設(shè)計(jì)防火規(guī)范》GB50222-95(2001年修訂版)《無(wú)障礙設(shè)計(jì)規(guī)范》GB50763-2012《屋面工程技術(shù)規(guī)范》GB50345-2012《綜合醫(yī)院建筑設(shè)計(jì)規(guī)范》JGJ49-88《綜合醫(yī)療建設(shè)標(biāo)準(zhǔn)》建標(biāo)110-2008《汽車庫(kù)建筑設(shè)計(jì)規(guī)范》JGJ100-98《民用建筑熱工設(shè)計(jì)規(guī)范》GB50176-93《公共建筑節(jié)能設(shè)計(jì)標(biāo)準(zhǔn)》GB50189-2005《廣西公共建筑節(jié)能設(shè)計(jì)規(guī)范》DBJ45/003-2012*****醫(yī)院為國(guó)家二級(jí)甲等綜合性醫(yī)院,外科綜合樓為現(xiàn)代化醫(yī)療設(shè)施。外科綜合樓地下一層,地上二十層;建筑主體高度78.95米;防火類別:一類,耐火等級(jí):一級(jí);主要結(jié)構(gòu)形式:鋼筋混凝土框架-剪力墻;抗震設(shè)防烈度:6度(按7度設(shè)防);防水等級(jí):屋面防水為I級(jí),地下室防水為二級(jí)??傮w布局本工程位于*****醫(yī)院大院(新院址)內(nèi)中心位置,急救中心及辦公綜合樓、業(yè)務(wù)綜合樓、康復(fù)治療用房及教學(xué)科研樓圍合之處;根據(jù)周邊環(huán)境及院方要求,主要人流出入口設(shè)在建筑的西南角;地下車庫(kù)的主要出入口設(shè)在建筑的東南角,為及時(shí)疏散車輛,在地下室的北側(cè)加設(shè)機(jī)動(dòng)車出入口。外科綜合樓一至三層與康復(fù)治療用房(規(guī)劃中)通過(guò)連廊連接,與南偏西面的業(yè)務(wù)綜合樓(已建成)通過(guò)斜坡連接。在外科綜合樓三面布置環(huán)行車道,與消防車通道結(jié)合。建筑設(shè)計(jì)3.3.1地下室一層停車場(chǎng),共停車位72個(gè)。3.3.2外科大樓科室安排一層:供應(yīng)中心二層:產(chǎn)科三層:產(chǎn)房四層:婦科五層:新生兒科六、七層:手術(shù)部①②八層:設(shè)備層九層:ICU重癥監(jiān)護(hù)十九層:標(biāo)準(zhǔn)病房二十層:中央空調(diào)機(jī)房、蓄熱水池屋頂:太陽(yáng)能或空氣能標(biāo)準(zhǔn)病房為普通病房,每層設(shè)一個(gè)護(hù)理單元,一個(gè)護(hù)理單元床位為50床,設(shè)三床間和四床間。護(hù)理單元采用中間走廊式布置*面,護(hù)士站設(shè)于單元中心。病房衛(wèi)生間靠外墻布置,不影響護(hù)士在走廊觀察病人情況,衛(wèi)生間可直接通風(fēng)采光,對(duì)其清潔衛(wèi)生也起到良好作用。陽(yáng)臺(tái)的設(shè)置既可提供病人休閑觀景*臺(tái),又能起到遮陽(yáng)作用,避免南方灼熱陽(yáng)光直射室內(nèi)。所有病房設(shè)綜合醫(yī)療槽,內(nèi)含醫(yī)療氣體管道接口、電氣插座、傳呼訊號(hào)按鈕、床頭燈等。3.3.3屋頂以上為各機(jī)房及太陽(yáng)能集熱板或空氣能機(jī)組。無(wú)障礙設(shè)計(jì)建筑物人流出入口處均設(shè)1/12坡度的無(wú)障礙坡道。其中的一臺(tái)電梯轎廂和電梯廳的無(wú)障礙設(shè)施和設(shè)計(jì)要求符合規(guī)范要求。主要通道設(shè)雙層扶手,扶手中心距地0.9m高。燈光標(biāo)志工程以及色彩分區(qū)外科綜合樓按醫(yī)院的統(tǒng)一圖案文字加色彩誘導(dǎo)標(biāo)志。電梯候梯廳、各科室入口及各交通樞紐布置導(dǎo)向標(biāo)志。各科室、病房各護(hù)理單元以不同顏色的扶手色帶區(qū)分不同部門,各科室入口處及護(hù)士站以燈光色彩標(biāo)志區(qū)分不同部門。各種無(wú)障礙設(shè)施,包括停車位、電梯、衛(wèi)生間等設(shè)國(guó)際通用無(wú)障礙標(biāo)志。各類工程處管網(wǎng)均按國(guó)家有關(guān)標(biāo)準(zhǔn)涂刷不同顏色油漆便于維修管理。剖面設(shè)計(jì)及豎向交通設(shè)計(jì)3.6.1外科綜合樓為地下一層,地上二十層。各層層高:地下一層5.0米(主體部分)和4.2米(非主體部分),一層5.0米,二?五層3.9米,六、七層4.5米,八層3.3米,十?二十層3.8米,室內(nèi)外高差0.45米,建筑總高78.95米(主體部分)。3.6.2交通的設(shè)計(jì)原則是做到醫(yī)患分流、潔污分流。本工程設(shè)七部病床梯(其中一部為消防電梯兼污物梯,一部為無(wú)障礙設(shè)施轎廂)。主要的電梯群是五部病床電梯,負(fù)一層至二十層均設(shè)站;一部病床梯(潔梯)主要為醫(yī)護(hù)人員和特殊患者使用,以保證高效性,負(fù)一層至二十層均設(shè)站;一部醫(yī)用電梯作為污物電梯使用,負(fù)一層至二十層均設(shè)站。編虧名稱載重車kg速度m/s停層站數(shù)提升咼度m臺(tái)數(shù)備注電梯①病床梯18001.75-1?202179.701電梯②病床梯18001.75-1?202179.701電梯③病床梯18001.75-1?202179.701無(wú)障礙設(shè)施轎廂電梯④病床梯18001.75-1?202179.701電梯⑤病床梯18001.75-1?202179.701潔梯18001.75-1?202179.701污物梯18002.0-1?202179.701消防電梯3.6.3本工程主樓設(shè)置兩部防煙樓梯,保證使用和疏散要求。立面設(shè)計(jì)外科綜合樓四周均包圍使用功能不同的建筑物,雖然建造時(shí)間不同,均為現(xiàn)代簡(jiǎn)潔的建筑風(fēng)格,較為統(tǒng)一。本工程建筑形象應(yīng)以融合到現(xiàn)狀的建筑風(fēng)格為主,更好的協(xié)調(diào)環(huán)境。內(nèi)部功能決定建筑外形是本工程的主要手法,采用玻璃和鋁板、涂料等建筑材料,顏色為冷調(diào)子,能更好地體現(xiàn)現(xiàn)代綜合醫(yī)療建筑的性格。建筑消防設(shè)計(jì)3.8.1本工程屬醫(yī)療類建筑,根據(jù)《高層民用建筑設(shè)計(jì)防火規(guī)范》GB50045—95(2005版)要求,為一類防火建筑,耐火等級(jí):一級(jí),設(shè)自動(dòng)滅火和火災(zāi)自動(dòng)報(bào)警系統(tǒng),走廊、地下室設(shè)機(jī)械排煙系統(tǒng)。消防控制室設(shè)于業(yè)務(wù)綜合樓一層,有直接對(duì)外開門。3.8.2在外科綜合樓三面布置車道,與消防車通道結(jié)合。建筑物的四面直接落地,可作為消防車的撲救面。3.8.3地下一層,設(shè)2個(gè)防火分區(qū),防火分區(qū)面積分別為433.80*方米(設(shè)備用房)、3030.86*方米(地下車庫(kù)),每個(gè)防火分區(qū)設(shè)一個(gè)安全出口(相鄰防火分區(qū)的防火墻設(shè)防火門)。地上二十層,每層為一個(gè)防火分區(qū),面積均在2000*方米以下。3.8.4本工程主樓設(shè)置兩部防煙樓梯,保證使用和疏散要求。3.8.5本工程設(shè)1部消防電梯。3.8.6安全疏散及疏散距離本工程為公建,主樓的兩部防煙樓梯寬度共3.15米寬,每層可疏散315人,滿足疏散要求。首層疏散樓梯直接通向室外,符合規(guī)范要求。病房部分:兩部樓梯之間房間至樓梯間最大距離不大于24mo其它部分:兩部樓梯之間房間至樓梯間最大距離不大于30mo房間最遠(yuǎn)點(diǎn)至門距離不大于15m。電梯間設(shè)前室,在走道通向前室地方設(shè)甲級(jí)防火卷簾,卷簾具有停滯功能。3.8.7建筑配件及構(gòu)造本工程防火隔墻采用200厚頁(yè)巖燒結(jié)多孔磚,耐火極限大于3小時(shí),相鄰的防火分區(qū)在防火隔墻上采用甲級(jí)防火門或防火卷簾門。消防水泵房、空調(diào)機(jī)房、消防控制室、發(fā)電機(jī)房及配電間房間設(shè)甲級(jí)防火門。所有管道井的隔墻采用200厚頁(yè)巖燒結(jié)多孔磚,耐火等級(jí)大于3小時(shí),管道井門為丙級(jí)防火門。窗間墻、窗檻墻的填充材料采用不燃燒材料。無(wú)窗間墻和窗檻墻的玻璃幕墻,在每層樓板外沿設(shè)置耐800高200厚砌體墻。玻璃幕墻與每層樓板、隔墻處的縫隙,采用不燃燒材料嚴(yán)密填實(shí)。3.8.8室內(nèi)裝修材料耐火等級(jí)符合現(xiàn)行國(guó)家標(biāo)準(zhǔn)《建筑內(nèi)部裝修設(shè)計(jì)防火規(guī)范》的有關(guān)規(guī)定。3.9節(jié)能設(shè)計(jì)本地區(qū)屬夏熱冬暖氣候地帶,根據(jù)《民用建筑熱工設(shè)計(jì)規(guī)范》要求和地區(qū)節(jié)能標(biāo)準(zhǔn),進(jìn)行節(jié)能設(shè)計(jì)。墻體選用200厚頁(yè)巖燒結(jié)多孔磚,屋面采用30厚絕熱擠塑聚苯乙烯板,外窗選用鋁合金窗中空Low-e玻璃。3.10建筑裝修3.10.1外裝修:外墻選用氟碳漆外墻涂料,斷熱鋁合金低輻射中空玻璃窗6+12A+6。3.10.2墻體材料外墻:200厚頁(yè)巖燒結(jié)多孔磚。內(nèi)墻:200或100厚頁(yè)巖燒結(jié)多孔磚。地下室側(cè)墻做法(從內(nèi)到外):20厚1:2水泥砂漿粉內(nèi)墻面;鋼筋混凝土結(jié)構(gòu)自防水,抗?jié)B等級(jí)>0.6Mpa;20厚1:2水泥砂漿找*;刷基層處理劑一遍;1.5厚聚氨酯防水涂料;1.5厚氯化聚乙烯橡膠共混防水卷材;30厚聚苯乙烯泡沫塑料板,用聚醋酸乙稀膠粘劑點(diǎn)粘保護(hù)層;三七灰土,分層夯實(shí)底板做法(從上到下):20厚1:2水泥砂漿粉地面;鋼筋混凝土結(jié)構(gòu)自防水,抗?jié)B等級(jí)>0.6Mpa;50厚C20細(xì)石混凝土保護(hù)層;點(diǎn)粘350號(hào)石油瀝青油氈一層保護(hù);1.5厚氯化聚乙烯橡膠共混防水卷材;1.5厚聚氨酯防水涂料;刷基層處理劑一遍;20厚1:2水泥砂漿找*;100厚C15混凝土墊層(在軟弱土層中>150厚);素土夯實(shí)道路頂板做法(從上到下):飾面層;25厚1:4干硬性水泥砂漿;50厚C30UEA補(bǔ)償收縮細(xì)石混凝土防水層,表面壓光,混凝土內(nèi)配直徑4鋼筋雙向中距150;滿鋪0.5厚聚乙烯薄膜一層;4厚彈性體改性瀝青防水卷材;刷基層處理劑一遍;20厚1:2.5水泥砂漿找*層;1:8水泥陶粒找坡層;現(xiàn)澆鋼筋混凝土地下室頂板結(jié)構(gòu)自防水,抗?jié)B等級(jí)>0.6Mpa,表面清掃干凈。種植頂板做法(從上到下):田園土;無(wú)紡布過(guò)濾層;150厚陶粒排(蓄)水層;70厚細(xì)石混凝土保護(hù)層(設(shè)分格縫,間距為6米);石油瀝青油氈隔離層;0.5厚鉛錫合金防水卷材;20厚乳化瀝青膨脹珍珠巖局部找坡(1:3水泥砂漿抹面);1.5厚合成高分子防水卷材;2厚合成高分子防水涂料;20厚1:3水泥砂漿找*層;現(xiàn)澆自防水鋼筋混凝土地下室頂板(結(jié)構(gòu)找坡>2%)屋面水屋面做法:8-10厚陶瓷地磚,1:1水泥砂漿填縫(摻建筑膠);25厚1:4干硬性水泥砂漿;40厚C20細(xì)石混凝土內(nèi)配直徑4鋼筋雙向中距150;干鋪聚酯纖維無(wú)妨布一層;30厚絕熱擠塑聚苯乙烯板兩層1.5厚合成高分子卷材、一層1.5厚合成高分子防水涂料;刷基層處理劑一遍20厚1:2.5水泥砂漿;20厚(最薄處)爐渣混凝土找*層找2%坡;(用于建筑找坡)現(xiàn)澆鋼筋混凝土屋面板.表面清掃干凈3.11附表外科綜合樓室內(nèi)裝修表房間名稱樓地面內(nèi)墻面墻裙或踢腳天棚吊頂各層樓梯前室、合用前室防滑地磚混合砂漿打底刮膩?zhàn)?,乳膠漆面層150高地磚踢腳輕鋼龍骨石胃板樓梯間防滑地磚150高地磚踢腳混合砂漿打底刮膩?zhàn)?,乳膠漆面層侯梯廳花岡石干掛花崗巖鋁合金吊頂新風(fēng)機(jī)房水泥砂漿地面吸音墻涂料踢腳礦棉吸音地下層地下室車庫(kù)、車道30厚C30細(xì)石混凝土混合砂漿(砌體墻血)、大白漿(碇墻面)150高1:2水泥砂漿大白漿制冷機(jī)房、生活水泵房、排煙機(jī)房水泥砂漿地面混合砂漿打底刮膩?zhàn)?,乳膠漆面層乳膠漆踢腳混合砂漿打底刮膩?zhàn)印? 、五?七、九層供應(yīng)中心、產(chǎn)房、新生兒科、手術(shù)部、ICU由二次裝修定八層設(shè)備層水泥砂漿地面吸音墻涂料踢腳礦棉吸音二、四、十?十九層主任辦、護(hù)長(zhǎng)辦、更衣室、值班室、示教室?;u混合砂漿打底刮膩?zhàn)?,乳膠漆面層150高地磚踢腳輕鋼龍骨石胃板病房、搶救室、護(hù)士站、走廊、醫(yī)牛辦橡膠地板150高橡膠踢腳輕鋼龍骨石胃板治療室PVC塑膠地板150高PVC塑膠輕鋼龍骨石胃板庫(kù)房?;u150高地磚踢腳混合砂漿打底刮膩?zhàn)?,乳膠漆面層陽(yáng)臺(tái)防滑地磚混合砂漿打底刮膩?zhàn)?,乳膠漆面層外詈室、衛(wèi)牛問、污洗間、開水間防滑地磚磁磚至吊頂?shù)追阑鸱莱彼芰习宥畬庸芾碛梅坎;u混合砂漿打底刮膩?zhàn)?,乳膠漆面層150高地磚踢腳輕鋼龍骨石胃板陽(yáng)臺(tái)、工具間、機(jī)組區(qū)域防滑地磚混合砂漿打底刮膩?zhàn)?,乳膠漆面層衛(wèi)生間防滑地磚磁磚至吊頂?shù)追阑鸱莱彼芰习逦蓓旊娞輽C(jī)房水泥砂漿地面混合砂漿打底刮膩?zhàn)樱槟z漆面層混合砂漿打底刮膩?zhàn)?,乳膠漆面層3.13經(jīng)濟(jì)技術(shù)指標(biāo)3.13.1院區(qū)總指標(biāo)(包括外科綜合樓)總用地面積40229.69*方米總建筑面積127429.50*方米建筑密度27.2%容積率2.69綠地率31.28%地面停車位105個(gè)地下停車位324個(gè)總病床數(shù)1520床3.13.2外科綜合樓指標(biāo)外科綜合樓基底lil積1543.30*方米外科綜合樓總建鞏面積33901.68*方米其中 地下室面積3464.66*方米地上面積30437.02*方米地下停車位72個(gè)總病床數(shù)588床建筑層數(shù)地下1層地上20層4.結(jié)構(gòu)工程概況本工程位于廣西壯族自治區(qū)*****醫(yī)院大院(新院址)內(nèi)中心位置。外科綜合樓地下一層,地上二十層;本工程建筑長(zhǎng)72.000m,寬23.000m,呈凸形布置,*面局部突出2.100m,突出部分寬20.300m,地下室長(zhǎng)85.200m,寬43.900m;地面以上20層,首層層高5.0m,二層、三層、四層、五層層高3.9m,六層、七層層高4.5m,八層層高3.3m,其余各層層高3.8m,±0.000以上78.950m(主體部分),室內(nèi)外高差0.45m,室外地面以上總高79.400m,地下一層,地下一層5.0米(主體部分)和4.2米(非主體部分),結(jié)構(gòu)層高4..1米(主體部分)和3.2米(非主體部分)。為滿足建筑功能及造型要求,本工程采用框架剪力墻結(jié)構(gòu)。設(shè)計(jì)依據(jù)4.2.1本工程建筑結(jié)構(gòu)設(shè)計(jì)使用年限為50年;4.2.2基本風(fēng)壓:0.3kN/m2,抗震設(shè)防烈度:7度;4.2.3由核工業(yè)**工程勘察院二0—二年五月五日編制提供的《*****醫(yī)院外科大樓樓巖土工程詳勘察報(bào)告》(工程編號(hào):GK2012—29);4.2.4報(bào)批通過(guò)的建筑方案圖紙;4.2.5結(jié)構(gòu)設(shè)計(jì)所執(zhí)行的主要法規(guī)和所采用的主要標(biāo)準(zhǔn):4.2.5.1《建筑結(jié)構(gòu)可靠度設(shè)計(jì)統(tǒng)一標(biāo)準(zhǔn)》(GE50068-2001)425.2《建筑工程抗震設(shè)防分類標(biāo)準(zhǔn)》(GE50223-2008)425.3《建筑結(jié)構(gòu)荷載規(guī)范》(GE50009-2012)(2012年版)425.4《建筑抗震設(shè)計(jì)規(guī)范》(GE50011-2001)(2008年版)425.5《混凝土結(jié)構(gòu)設(shè)計(jì)規(guī)范》(GE50010-2002)425.6《砌體結(jié)構(gòu)設(shè)計(jì)規(guī)范》(GE50003-2001)425.7《建筑地基基礎(chǔ)設(shè)計(jì)規(guī)范》(GE50007-2002)425.8《高層建筑混凝土結(jié)構(gòu)技術(shù)規(guī)程》(JGJ3-2002)425.9《建筑樁基技術(shù)規(guī)范》(JGJ94-2008)4.2.5.10《地下工程防水技術(shù)規(guī)范》(GE50108-2008)4.2.5.11《型鋼混凝土組合結(jié)構(gòu)技術(shù)規(guī)程》(JGJ138-2001)4.2.5.12《建筑地基處理技術(shù)規(guī)范》(JGJ79-2002)4.2.5.13《建筑基樁檢測(cè)技術(shù)規(guī)范》(JGJ106-2003)4.2.5.14《高層建筑箱形與筏形基礎(chǔ)技術(shù)規(guī)范》(JGJ6-99)4.2.5.15《建筑設(shè)計(jì)防火規(guī)范》(GE50016-2006)4.2.5.16《高層民用建筑設(shè)計(jì)防火規(guī)范》(GE50045-95)(2005年版)4.2.5.17《工業(yè)建筑防腐蝕設(shè)計(jì)規(guī)范》(GE50046-2008)。4.3建筑分類等級(jí)4.3.1根據(jù)《建筑結(jié)構(gòu)可靠度設(shè)計(jì)統(tǒng)一標(biāo)準(zhǔn)》(GE50068-2001)第1.0.8條表1.0.8,本工程建筑結(jié)構(gòu)的安全等級(jí)為二級(jí);4.3.2根據(jù)《建筑地基基礎(chǔ)設(shè)計(jì)規(guī)范》(GE50007-2002)第3.0.1條表3.0.1,本工程地基基礎(chǔ)設(shè)計(jì)等級(jí)為甲級(jí);4.3.3根據(jù)《建筑工程抗震設(shè)防分類標(biāo)準(zhǔn)》(GB50223-2208)第4.0.3條第2款,本工程為三級(jí)醫(yī)院住院用房,建筑抗震設(shè)防類別為重點(diǎn)設(shè)防類;4.3.4根據(jù)《高層建筑混凝土結(jié)構(gòu)技術(shù)規(guī)程》(JGJ3-2002)第4.8.1條、第4.8.2條表4.8.2,本工程框架抗震等級(jí)為二級(jí),剪力墻抗震等級(jí)為二級(jí);4.3.5根據(jù)《地下工程防水技術(shù)規(guī)范》(GB50108-2008)第3.2.1條表3.2.1,本工程地下室防水等級(jí)為二級(jí);4.3.6根據(jù)《高層民用建筑設(shè)計(jì)防火規(guī)范》(GB50045-95)(2005年版)第3.0.1條表3.0.1、第3.0.4條,本工程建筑防火分類為一類,本工程建筑的耐火等級(jí)為二級(jí),地下室的耐火等級(jí)為一級(jí)。4.4 主要荷載取值4.4.1樓(屋)面活荷載、特殊設(shè)備荷載:類別標(biāo)準(zhǔn)值(kN/mz)類別標(biāo)準(zhǔn)值(kN/mz)病房2.0會(huì)議室2.0門診室2.0去污、清潔區(qū)5一般資料檔案室2.5書庫(kù)5.0檔案庫(kù)5.0儲(chǔ)藏室5.0新風(fēng)機(jī)房7.0電梯機(jī)房7.0庫(kù)房3.5廁所、衛(wèi)生間2.5走廊3.5門廳3.5樓梯3.5病房陽(yáng)臺(tái)2.5公共陽(yáng)臺(tái)3.5不上人屋面0.5上人屋面2.0家屬等候室3.5器械庫(kù)2.5手術(shù)室3.0污物走道2.5冷風(fēng)機(jī)組、熱水機(jī)組、冷卻塔3.5發(fā)電機(jī)房10.0汽車通道停車庫(kù)單向板樓蓋4.0消防車通道單向板樓蓋35.0雙向板樓蓋2.5雙向板樓蓋24.04.4.2風(fēng)荷載:4.4.2.150年一遇的基本風(fēng)壓值為0.30kN/m2;4.4.2.2100年一遇的基本風(fēng)壓值為0.35kN/m2;4.4.2.3地面粗糙度類別為B類;4.4.3地震作用:設(shè)計(jì)基本地震加速度設(shè)計(jì)地震分組場(chǎng)地類別0.05g第一組II類場(chǎng)地特征周期結(jié)構(gòu)阻尼比地震影響系數(shù)多遇地震罕遇地震0.35s0.050.040.284.4.4抗浮設(shè)防水位-3.0m(相對(duì)土0.000)。4.5上部及地下室結(jié)構(gòu)設(shè)計(jì)4.5.1根據(jù)建筑功能及造型需要,本工程采用無(wú)縫設(shè)計(jì),主樓長(zhǎng)72.000m,地下室長(zhǎng)82.500m,寬43.900m,超過(guò)了《混凝土結(jié)構(gòu)設(shè)計(jì)規(guī)范》(GB50010-2002)對(duì)現(xiàn)澆鋼筋混凝土結(jié)構(gòu)伸縮縫最大間距的要求,設(shè)計(jì)采用設(shè)置后澆帶(后澆帶位置詳結(jié)構(gòu)*面布置圖)的方式,以減少施工階段混凝土收縮對(duì)結(jié)構(gòu)的不利影響,主樓部分與超出主樓地下室部分荷載差異較大,設(shè)計(jì)采用設(shè)置沉降后澆帶,待主樓主體施工完成后澆筑后澆帶混凝土將結(jié)構(gòu)連為整體的方式,以減少沉降差異對(duì)結(jié)構(gòu)的不利影響;4.5.2主樓部分采用現(xiàn)澆鋼筋混凝土框架剪力墻結(jié)構(gòu),為滿足建筑功能及造型需要,部分框架柱外凸或內(nèi)收,各層樓屋面采用現(xiàn)澆鋼筋混凝土梁板結(jié)構(gòu);地下室采用現(xiàn)澆鋼筋混凝土外墻,超出主樓地下室部分采用現(xiàn)澆鋼筋混凝土框架結(jié)構(gòu),負(fù)一層樓面及地下室頂板采用現(xiàn)澆鋼筋混凝土框架結(jié)構(gòu)。4.6 地基基礎(chǔ)設(shè)計(jì)4.6.1工程地質(zhì)和水文地質(zhì)概況4.6.1.1各巖土層主要參數(shù):指標(biāo)土層'、名稱 、、承載力特征值壓縮模量天然重度粘聚力標(biāo)準(zhǔn)值內(nèi)摩擦角標(biāo)準(zhǔn)值F(kPa)akEs(MPa)y(kN/ms)c(kPa)k①(。)k素填土①1003.016.0————耕土②802.016.0————粘土③2109.017.93&4310.64粉質(zhì)粘土④21010.017.030.69&15泥質(zhì)粉砂巖⑤40015——————4.6.1.2樁基設(shè)計(jì)巖土參數(shù):土層名稱及編號(hào)靜壓樁沖(鉆)孔樁長(zhǎng)螺旋鉆孔樁樁的極限側(cè)阻力標(biāo)準(zhǔn)值qsik(kPa)樁的極限端阻力標(biāo)準(zhǔn)值qPk(kPa)樁的極限側(cè)阻力標(biāo)準(zhǔn)值qsik(kPa)樁的極限端阻力標(biāo)準(zhǔn)值qPk(kPa)樁的極限側(cè)阻力標(biāo)準(zhǔn)值qsik(kPa)樁的極限端阻力標(biāo)準(zhǔn)值qPk(kPa)耕土②18——16——15——粘土③75——70——70——粉質(zhì)粘土④90250080——80800泥質(zhì)粉砂巖⑤140600012015001201204.6.1.3場(chǎng)地土腐蝕性情況評(píng)價(jià):水土對(duì)混凝土結(jié)構(gòu)對(duì)鋼結(jié)構(gòu)對(duì)鋼筋混凝土結(jié)構(gòu)中的鋼筋對(duì)混凝土結(jié)構(gòu)對(duì)鋼結(jié)構(gòu)對(duì)鋼筋混凝土結(jié)構(gòu)中的鋼筋無(wú)弱無(wú)無(wú)弱無(wú)4.6.1.4本工程抗浮設(shè)防水位-3.Om(相對(duì)土0.000)。4.6.2基礎(chǔ)選型說(shuō)明:4.6.2.1主樓部分豎向荷載較大,設(shè)計(jì)采用局部*板式樁筏基及局部承臺(tái)樁基,樁基為混凝土預(yù)制管樁(D二500),以泥質(zhì)粉砂巖⑤作為樁端持力層,樁端進(jìn)入持力層1?2m,單樁承載力特征值1550kN;4.6.2.2超出主樓地下室部分,設(shè)計(jì)采用混凝土預(yù)制管樁,以質(zhì)粉粘土@泥質(zhì)粉砂巖⑤作為樁端持力層,樁端進(jìn)入持力層2?3m,單樁承載力特征值lOOOkN;4.6.2.3本工程抗浮設(shè)防水位較高,采用樁基礎(chǔ),利用樁基的抗拔承載力,以抵抗水浮力向上的作用效應(yīng)。4.6.3基坑支護(hù)措施由于本工程基坑周邊建筑物較多,開挖深度較大,為確保周邊建筑物安全,基坑支護(hù)方案采用樁+錨索支護(hù)體系。4.7結(jié)構(gòu)分析4.7.1計(jì)算軟件4.7.1.1本工程結(jié)構(gòu)整體計(jì)算采用中國(guó)建筑科學(xué)研究院建筑工程軟件研究所編制的PKPM系列結(jié)構(gòu)空間有限元分析設(shè)計(jì)軟件(2010年7月版),SATWE(2010年7月版);7.2結(jié)構(gòu)分析輸入的主要參數(shù):結(jié)構(gòu)材料信息鋼筋混凝土結(jié)構(gòu)混凝土容重(kN/ms)26鋼材容重(kN/np)78地下室層數(shù)1(地下室頂板作為整體計(jì)算嵌固部位)豎向荷載計(jì)算信息按模擬施工3加載計(jì)算風(fēng)荷載計(jì)算信息計(jì)算X、Y兩個(gè)方向的風(fēng)荷載地震力計(jì)算信息計(jì)算X、Y兩個(gè)方向的地震力結(jié)構(gòu)類別框架 勇力墻結(jié)構(gòu)采用的樓層剛度算法層間勇力比層間位移算法修正后的基本風(fēng)壓(kN/m2)0.35地面粗糙度B是否考慮風(fēng)振是振型組合方法CQC計(jì)算振型數(shù)15地震烈度6(7度設(shè)防)場(chǎng)地類別II設(shè)計(jì)地震分組第一組特征周期(s)0.35多遇地震影響系數(shù)最大值0.04罕遇地震影響系數(shù)最大值0.28框架的抗震等級(jí) *剪力墻的抗震等級(jí)._*活荷重力荷載代表值組合系數(shù)0.50周期折減系數(shù)0.90結(jié)構(gòu)的阻尼比(%)5是否考慮偶然偏心是柱、墻活荷載是否折減折減折減系數(shù)按GB50009-2001(2006年版)表4.1.2傳到基礎(chǔ)的荷載是否折減折減中梁剛度增大系數(shù)2.0梁端彎矩調(diào)幅系數(shù)0.85連梁剛度折減系數(shù)0.70結(jié)構(gòu)重要性系數(shù)1.0柱計(jì)算長(zhǎng)度計(jì)算原則有側(cè)移梁柱重疊部分簡(jiǎn)化剛域是否考慮P-Delt效應(yīng)不考慮柱配筋計(jì)算原則單偏壓計(jì)算,雙偏壓復(fù)核鋼構(gòu)件截面凈毛面積比0.854.7.3主要控制性計(jì)算結(jié)果:4.7.3.1結(jié)構(gòu)質(zhì)量活載產(chǎn)生的總質(zhì)量(t)恒載產(chǎn)生的總質(zhì)量(t)結(jié)構(gòu)的總質(zhì)量(t)6081.75252903.94558985.6954.7.3.2相鄰層側(cè)移剛度比:樓層號(hào)RatxRatyRatxlRatyl11.00001.000015.94704.611420.23330.70681.64561.582531.26781.25751.69301.791841.00000.99601.64731.707450.93920.97061.57241.653260.99841.00081.46821.673370.81780.81781.13641.303081.00001.00001.04201.133791.36141.36881.60301.6980100.71400.74341.33601.4232111.00521.00461.33551.3943121.00001.00001.33701.3713130.97010.97011.33051.3547141.00001.00001.32721.3534151.00001.00001.33071.3683161.00001.00001.35101.4114170.92310.92311.39991.5116181.00001.00001.51471.5833191.00001.00001.60951.7488201.00000.98991.89972.0735210.91540.99891.93862.147822————————說(shuō)明:Ratx、Raty X、Y方向本層側(cè)移剛度與下一層側(cè)移剛度的比值;Ratxl、Ratyl X、Y方向本層側(cè)移剛度與上一層側(cè)移剛度70%的比值或上二層*均側(cè)移剛度80%的比值;各層側(cè)向剛度與上一層側(cè)移剛度70%的比值或上三層*均側(cè)移剛度80%的比值均大于1,滿足《高層混凝土結(jié)構(gòu)技術(shù)規(guī)程》(JGJ3-2002)4.4.2條的要求。4.7.3.3結(jié)構(gòu)整體抗傾覆驗(yàn)算結(jié)果:抗傾覆力矩Mr傾覆力矩Mov比值Mr/Mov零應(yīng)力區(qū)(%)X風(fēng)荷載30249786.0106544.6283.920.00Y風(fēng)荷載13465966.0316217.342.580.00X地震荷載29051636.0492179.059.030.00Y地震荷載1293259&0619896.120.860.00說(shuō)明:X向剛重比EJ/GH2=3.58,Y方向剛重比EJ/GH2=6.89;結(jié)構(gòu)剛重比大于1.4,能通過(guò)《高層混凝土d d結(jié)構(gòu)技術(shù)規(guī)程》(JGJ3-2002)5.4.4條第1款整體穩(wěn)定驗(yàn)算;結(jié)構(gòu)剛重比大于2.7,根據(jù)《高層混凝土結(jié)構(gòu)技術(shù)規(guī)程》(JGJ3-2002)5.4.1條,可以不考慮重力二階效應(yīng)的不利影響。7.3.4樓層抗剪承載力及承載力比值:層號(hào)X向承載力(xlOOY向承載力(xlOORatio_BU:XRatio_BU:Y10.14010.12551.971.2520.71160.10020.830.8830.85990.11371.031.0240.83860.11091.271.1950.66000.93401.031.0260.64180.91511.231.1970.52050.76931.031.0280.50550.75270.760.8490.66130.89241.541.34100.42990.66631.021.02110.42010.65361.031.03120.40620.63661.071.07130.37850.59451.041.03140.36280.57531.051.04150.34540.55391.061.04160.32680.53051.151.15170.28440.46011.071.05180.26500.43661.091.07190.24240.40961.111.08200.21760.37941.211.09210.18040.34723.093.80220.58340.91310.750.77230.78080.11800.981.10240.79670.10773.353.36說(shuō)明:Ratio_BU 本層與上一層的抗勇承載力之比;各層與上一層的抗剪承載力之比均大于0.80,滿足《高層混凝土結(jié)構(gòu)技術(shù)規(guī)程》(JGJ3-2002)4.4.3條的要求。7.3.5結(jié)構(gòu)考慮扭轉(zhuǎn)耦聯(lián)時(shí)的振動(dòng)周期振型號(hào)周期轉(zhuǎn)角*動(dòng)系數(shù)(X+Y)扭轉(zhuǎn)系數(shù)12.592117&281.00(1.00+0.00)0.0021.87898&000.99(0.00+0.99)0.0131.3406104.310.03(0.00+0.02)0.9740.790117&991.00(1.00+0.00)0.0050.48018&620.98(0.00+0.98)0.0260.4076179.621.00(1.00+0.00)0.0070.345083.440.04(0.00+0.04)0.9680.2661179.951.00(1.00+0.00)0.0090.22458&470.98(0.00+0.98)0.02100.20580.601.00(1.00+0.00)0.00110.179093.690.43(0.01+0.42)0.57120.16312.341.00(0.99+0.00)0.00130.150682.780.50(0.01+0.49)0.50140.129493.460.71(0.01+0.70)0.29150.12594.140.99(0.98+0.01)0.01說(shuō)明:主的第一自振周期Tt與*動(dòng)為主的第一自振周期T1之比:Tt/Tl=l.3406/2.5921=0.518<0.85,滿足《高層混凝土結(jié)構(gòu)技術(shù)規(guī)程》(JGJ3-2002)4.3.5條的要求;地震作用最大方向=-1.118(度)。7.3.6振型數(shù)及有效質(zhì)量系數(shù):計(jì)算振型數(shù)15,99.5%>90%,Y方向的有效質(zhì)量系數(shù)99.5%99.54%>90%,滿足《高層混凝土結(jié)構(gòu)技術(shù)規(guī)程》(JGJ3-2002)5.1.13條第2款的要求。7.3.7結(jié)構(gòu)位移計(jì)算結(jié)果:作用類別地震作用風(fēng)荷載作用作用方向XX+0.05X-0.05YY+0.05Y-0.05XYRatio1.031.021.041.071.191.161.031.09Ratio-D1.051.031.081.221.211.331.181.11MAX-D/h(n)1/1416(10)1/1428(10)1/1406(10)1/1474(25)1/1495(125)1/1448(19)1/6441(8)1/3242(25)說(shuō)明:Ratio 取大位移與層*均位移的比值;RatioD 取大層間位移與*均層間位移的比值;MAXD/h 最大層間位移角;(n)——最大層間位移角所在的樓層號(hào);考慮偶然偏心地震作用,各樓層的最大水*位移和層間位移大于該樓層*均值的1.2倍,不大于該樓層*均值的1.5倍,滿足《高層混凝土結(jié)構(gòu)技術(shù)規(guī)程》(JGJ3-2002)4.3.5條的要求。7.3.8框架柱地震傾覆力矩和地震剪力百分比:地震力作用方向柱傾覆力矩墻傾覆力矩柱傾覆力矩百分比X180511.6245816.93&92%Y74773.1430442.913.75%地震力作用方向柱剪力墻勇力柱剪力百分比X337.27816.94.31%Y50&910052.45.06%說(shuō)明:在基本振型地震作用下,框架部分承受的地震傾覆力矩不大于結(jié)構(gòu)總地震傾覆力矩的50%,滿足《高層混凝土結(jié)構(gòu)技術(shù)規(guī)程》(JGJ3-2002)&1.3條的要求,框架的抗震等級(jí)可按框架一一剪力墻結(jié)構(gòu)采用,本工程框架抗震等級(jí)為二級(jí)。4.8.主要結(jié)構(gòu)材料。8.1混凝土強(qiáng)度等級(jí):構(gòu)件類別混凝土強(qiáng)度等級(jí)構(gòu)件類別混凝土強(qiáng)度等級(jí)樁基礎(chǔ)C80底板混凝土墊層C15筏板基礎(chǔ)C35地下室底板C35地下室外墻C55地下室框架柱C55負(fù)一層樓面梁板C35地下室頂板C35主樓框架柱C55弋30主樓梁板C35~25構(gòu)造柱C25圈梁、過(guò)梁C25非結(jié)構(gòu)構(gòu)件C254.8.2鋼筋種類鋼筋位置鋼筋種類鋼筋位置鋼筋種類筏板受力鋼筋HRB400承臺(tái)受力鋼筋HRB400承臺(tái)箍筋HRB400樓板受力鋼筋HRB400樓板分布鋼筋HRB400梁、柱縱筋HRB400梁、柱箍筋HRB400梁架立鋼筋HRB4004.8.3砌體材料及砂漿強(qiáng)度等級(jí)詳建筑設(shè)計(jì)說(shuō)明;4.9其他需要說(shuō)明的內(nèi)容本工程初步設(shè)計(jì),所采用的單樁承載力特征值,是依靠地質(zhì)報(bào)告通過(guò)理論計(jì)算的估算值,根據(jù)《建筑樁基技術(shù)規(guī)范》(JGJ94-2008)5.3.1條第1款的要求,本工程基礎(chǔ)設(shè)計(jì)等級(jí)為甲級(jí),單樁豎向極限承載力標(biāo)準(zhǔn)值,應(yīng)通過(guò)單樁靜載試驗(yàn)確定,基礎(chǔ)施工前,應(yīng)通過(guò)試樁確定單樁豎向承載力極限值,并將試驗(yàn)結(jié)果提交設(shè)計(jì)單位,作為基礎(chǔ)設(shè)計(jì)的依據(jù)。5.給排水5.1工程概況本工程為醫(yī)院外科綜合樓(建筑高度±50m),地下1層,地上20層,地下室為車庫(kù)及設(shè)備用房,地上1?5層為供應(yīng)中心、產(chǎn)科、產(chǎn)房、婦科、新生兒科,6、7層為手術(shù)部,8層為設(shè)備層,9層為ICU病房,10?19層為標(biāo)準(zhǔn)病房,20層為中央空調(diào)機(jī)房、蓄熱水池。5.2設(shè)計(jì)依據(jù)1現(xiàn)行主要國(guó)家規(guī)程規(guī)范:《建筑給水排水設(shè)計(jì)規(guī)范》GB50015-2003(2009版);《室外給水設(shè)計(jì)規(guī)范》GB50013-2006;《室外排水設(shè)計(jì)規(guī)范》GB50014-2010;《綜合醫(yī)院建筑設(shè)計(jì)規(guī)范》JGJ49-88o2.2有關(guān)批文和協(xié)議合同(見建筑部分);5.2.3甲方提供的有關(guān)大樓給排水資料和要求;5.2.4建筑提供本工程紅線范圍內(nèi)的*、剖面圖。5.3設(shè)計(jì)范圍1給水設(shè)計(jì);3.2開水及熱水設(shè)計(jì);5.3.3排水設(shè)計(jì)。5.4給水設(shè)計(jì)4.1水源采用市政自來(lái)水作為本工程全部用水水源(含消防用水與綠化用水)。擬從醫(yī)院給水環(huán)網(wǎng)接出DN200給水管,滿足其生活及消防用水,供水水壓不小于為0.30MPao5.4.2生活用水量統(tǒng)計(jì)(詳見下表)用水部位用水標(biāo)準(zhǔn)單位數(shù)量用水時(shí)間變化系數(shù)用水量(立方米)最大日最大時(shí)*均時(shí)1~4層病床300.00L/病床?d9924.02.2029.702.731.241?4層醫(yī)務(wù)人員200.00L/人?班728.01.8014.403.241.85~19層病床300.00L/病床?d48924.02.20146.7013.456.115?19層醫(yī)務(wù)人員200.00L/人?班2888.01.8057.6012.967.20停車庫(kù)地面沖洗水3.00L/*方米?次35406.01.0010.621.771.77空調(diào)補(bǔ)水6m3/h124.01.0014440.1024.10未預(yù)見水按本表以上項(xiàng)目的10%計(jì)40.307.434.22合計(jì)443.3074.2546.445.4.3給水系統(tǒng)根據(jù)提供的市政水壓,-1?4層由市政管網(wǎng)直接供水,下行上給;中區(qū)5層?14層采用地下室變頻設(shè)備加壓供水,下行上給;高區(qū)15層?20層采用地下室變頻設(shè)備加壓供水,下行上給。為滿足規(guī)范中最低衛(wèi)生器具配水點(diǎn)處?kù)o水壓不宜大于0.45MPa的要求,超壓部分須設(shè)減壓閥減壓后供水。二次供水方式采用“前置水箱+變頻水泵”。4.4水池及水箱生活水池和消防水池均建于地下室。生活水池采用前置不銹鋼水箱,消防水池采用鋼筋混凝土水池。生活水箱尺寸為4.0mx6.0mx2.5m,共2座,其有效水深2.2m,其有效容積為m3>95.78m3(按最高日用水量的25%),滿足設(shè)計(jì)需要。消防水池院區(qū)統(tǒng)一考慮,建設(shè)于業(yè)務(wù)綜合樓地下室,同時(shí)滿足本單體消防要求。屋頂消防水箱采用鋼筋混凝土結(jié)構(gòu),尺寸為4mX3mX2m,有效水深為1.5m,有效容積18.0m3,滿足設(shè)計(jì)要求。采用電動(dòng)閥控制進(jìn)水。5.4.5水泵房水泵房位于地下一層,內(nèi)設(shè)生活水箱尺寸為4.0mx6.0mx2.5m,共2座,高區(qū)生活加壓泵2臺(tái)(2用1備),水泵的參數(shù)為:Q=36.1m3/h,H=105m,N=22kW;中區(qū)生活加壓泵2臺(tái)(2用1備),水泵的參數(shù)為:Q=61.6m3/h,H=85m,N=37kW;水泵房?jī)?nèi)設(shè)排水溝,排往集水坑。5.4.8管材及接口室內(nèi)冷水管采用薄壁不銹鋼管,鎖擴(kuò)式連接;室外埋地給水管采用PE塑料給水管,電熱熔連接。5.5開水及熱水設(shè)計(jì)5.1開水設(shè)計(jì)為滿足醫(yī)務(wù)人員和病人的開水使用,在2?19層的開水間內(nèi)分別設(shè)置1臺(tái)電開水器,每臺(tái)N=6kWo5.5.2熱水設(shè)計(jì)為滿足醫(yī)院使用要求,現(xiàn)對(duì)病房和醫(yī)生辦公室進(jìn)行集中熱水供應(yīng),采用全日供熱熱水系統(tǒng),病床總數(shù)為588人,每人熱水定額取為150L/d,冷、熱水溫度分別取為15°C和60°C,根據(jù)熱水公式Q=KmqC(t-1)P/86400計(jì)算設(shè)計(jì)小時(shí)耗熱量為1331.6(kW),設(shè)計(jì)小時(shí)熱水hhrr 1 r量為25.88(ms/h)o為保證熱水供應(yīng)及方便計(jì)量,可按部門設(shè)置分水表,為精確計(jì)量,可在標(biāo)準(zhǔn)病房設(shè)置IC卡智能水表。建議采用“太陽(yáng)能+熱泵熱水機(jī)組”供熱,空氣源熱泵熱水機(jī)組共10臺(tái)。單臺(tái)制熱能力為480kW,*均輸入功率126kW(最大輸入功率270W),正常工況下熱水產(chǎn)量13.76m3/ho太陽(yáng)能系統(tǒng)采用吸收率可達(dá)96%,散射率低于4%高效的真空管,每組2100mm真空管25支,15°C工況下,晴好天氣每組產(chǎn)45°C?85°C熱水450L,初步考慮設(shè)置58臺(tái),最終可根據(jù)業(yè)主需求和屋面放置情況調(diào)整太陽(yáng)能熱水器數(shù)量。配套不銹鋼儲(chǔ)熱水箱1個(gè)(每個(gè)有效容積為36ms)。為保證熱水溫度及充分循環(huán),須設(shè)回水系統(tǒng),回水泵設(shè)于屋面?;厮玫男吞?hào)為Q=18.Oms/h,H二11.5m,P=l.5kW,共2臺(tái),1用1備。為保證18?20層熱水壓力滿足使用要求,須設(shè)屋頂熱水增壓水泵。熱水加壓水泵的型號(hào)為Q=18.Oms/h,H二18.5m,P=l.50kW,共2臺(tái),1用1備。太陽(yáng)能系統(tǒng)及熱泵熱水機(jī)組系統(tǒng)位于屋頂熱水機(jī)房?jī)?nèi),水箱及熱水管采用超細(xì)玻璃棉進(jìn)行保溫。5.5.3管材及接口室內(nèi)熱水管采用薄壁不銹鋼管,鎖擴(kuò)式連接。5.6排水設(shè)計(jì)本工程排水系統(tǒng)采用雨污分流制。一層公共衛(wèi)生間污水單獨(dú)排出。公共衛(wèi)生間污水管采用環(huán)形通氣立管伸頂通氣,病房衛(wèi)生間采用專用通氣立管伸頂通氣。污水經(jīng)化糞池處理后,再經(jīng)污水處理站統(tǒng)一消毒處理后就近排入市政管道。6.2地下室排水泵通過(guò)集水坑水位自動(dòng)控制啟閉。消防電梯集水坑1個(gè),設(shè)2臺(tái)潛污泵,Q=45m3/h,H二15m,N=4kW(1用1備)。地下1層汽車基坑內(nèi)設(shè)排水溝,溝底坡向集水坑,排水統(tǒng)一收集后提升至室外雨水井。地下1層水泵房設(shè)有1個(gè)集水坑,設(shè)置兩臺(tái)潛污泵,Q=45m3/h,H=15m,N=4kWo5.6.3雨水系統(tǒng)設(shè)計(jì)采用桂*市暴雨強(qiáng)度公式:_2270(1+0.4711gP)q— t+6.2P0.667屋面設(shè)計(jì)重現(xiàn)期P取5a,降雨歷時(shí)t取5min,則q=6.02(L/s.100m2);室外場(chǎng)地設(shè)計(jì)5重現(xiàn)期P取2d。屋面雨水采用雨水斗收集,單斗單立管排除,場(chǎng)地雨水由帶篦子暗溝及雨水口收集,通過(guò)雨水暗溝及雨水管排除。場(chǎng)地雨水口按25?50m間距布置,收集后雨水排入雨水檢查井。5.6.4管材及接口室內(nèi)污(廢)水立管采用中空螺旋消音管(PVC-U),雨水管、污水橫管及空調(diào)管均采用塑料排水管(PVC-U),專用膠粘接。室外埋地排水管采用增強(qiáng)復(fù)合聚丙烯(FRPP)加筋管(SN=8kN/m2),橡膠圈承插連接。潛污泵出水管采用國(guó)標(biāo)熱鍍鋅鋼管,焊接。5.7衛(wèi)生潔具除殘疾人衛(wèi)生間采用陶瓷坐式大便器,其它公共衛(wèi)生間和病房衛(wèi)生間大便器均采用陶瓷蹲式大便器,配腳踏延時(shí)閥;小便器采用壁掛式,配紅外線沖洗閥;洗臉盆配陶芯冷熱水龍頭,淋浴器采用帶冷熱龍頭淋浴器。5.8給排水材料表詳見設(shè)計(jì)圖紙。6.電氣6.1設(shè)計(jì)依據(jù)6.1.1現(xiàn)行主要國(guó)家規(guī)程規(guī)范:《低壓配電設(shè)計(jì)規(guī)范》(GB50054-95);《高層民用建筑設(shè)計(jì)防火規(guī)范》(GB50045-95V2005年版>);《民用建筑電氣設(shè)計(jì)規(guī)范》(JGJ16-2008);《建筑照明設(shè)計(jì)標(biāo)準(zhǔn)》(GB50034-2004);《火災(zāi)自動(dòng)報(bào)警系統(tǒng)設(shè)計(jì)規(guī)范》(GB50116-98);《建筑物防雷設(shè)計(jì)規(guī)范》(GB50057-94V2000年版>);《綜合醫(yī)院建筑設(shè)計(jì)規(guī)范》(JGJ49-88);6.1.2全國(guó)民用建筑工程設(shè)計(jì)電氣專業(yè)技術(shù)措施。6.1.3上級(jí)批準(zhǔn)的有關(guān)文件。6.1.4建設(shè)單位的有關(guān)資料和要求。6.1.5有關(guān)工種向本專業(yè)提供的圖紙和資料。6.2 設(shè)計(jì)范圍10/0.4kV變配電設(shè)計(jì);6.2.2動(dòng)力配電設(shè)計(jì);6.2.3照明設(shè)計(jì);6.2.4建筑物防雷接地系統(tǒng)及安全措施;6.2.5火災(zāi)自動(dòng)報(bào)警及聯(lián)動(dòng)控制系統(tǒng)設(shè)計(jì);6.2.6有線電視、電話及綜合布線系統(tǒng)設(shè)計(jì)6.2.7病房呼叫系統(tǒng)管線設(shè)計(jì);6.310/O?4kV變配電設(shè)計(jì)6.3.1負(fù)荷等級(jí)本工程為一類高層建筑。其消防控制室、防排煙風(fēng)機(jī)、消防電梯、應(yīng)急照明及疏散指示標(biāo)志燈等消防設(shè)備,以及手術(shù)室及其相應(yīng)的空調(diào)設(shè)備、ICU監(jiān)護(hù)室、監(jiān)護(hù)病房、CT(MR、DSA等)治療室、走道照明、客梯用電等為一級(jí)負(fù)荷;高級(jí)病房用電為二級(jí)負(fù)荷;其余普通照明插座等為三級(jí)負(fù)荷。6.3.2.供電電源本工程電源電壓等級(jí)為10kV。由本院內(nèi)的門診綜合樓高壓配電室引來(lái)兩路電源。兩路電源需滿足一級(jí)負(fù)荷的供電要求。6.3.3本設(shè)計(jì)的負(fù)荷統(tǒng)計(jì)是根據(jù)建筑、給排水、空調(diào)等工種提供的資料進(jìn)行計(jì)算的,其中照明負(fù)荷是按單位容量法進(jìn)行計(jì)算。本工程的設(shè)備容量為5708.92kW,計(jì)算容量為3218.3kW,視在容量為3411.4kVA。負(fù)荷計(jì)算詳負(fù)荷計(jì)算表1?2。負(fù)荷計(jì)算表1序a用電設(shè)備組名稱設(shè)備容量說(shuō)m需用系數(shù)(Kk)gos4?tg*計(jì)算值備注安裝的工作的FjQjSjIjtkW)(kVar)(kVA)(A)1TM勵(lì)力〕1內(nèi)M擺±1哇200200.0□.75o.e0.75150.00112.502151.8151.8□.450.80.T568.3151.233醫(yī)療設(shè)備9159150.50.050.B2457.50203.534電梯2422420.40.80.T5£680T2.605平時(shí)鳳機(jī)767S□.35o.e0.7564.6048.456電開水器1531刃0.610.00SI800.007士■百汎HF132B60.7o.s0.T546.2034.658空氣源熱泵141.4130.70.850.80.T5111.1083.329消防水泵31.51o.s0.751.501.13不計(jì)人10消防風(fēng)機(jī).肪火卷簾13413410.80.T5134.00100.50不計(jì)入11小計(jì)1934J□.850.&3108&.31686.291Z84.931946.8712冋陰呆圮KZ0.33901.635&9.6210&6.當(dāng)1615.9013無(wú)功補(bǔ)償34014合計(jì)0.930.33901.&346.3965.S1463.415變壓器容量12501677.32TI1舲棟站、空調(diào)設(shè)備〕:1in曲641&410.90.80.T5576.9432.682冷除(俱障、*m1S51480.90.80.75133.299.903網(wǎng)11盤皆,篡Bt5=rchin160180□.850.80.T5153114.754十卄9690.800.750B3.1B4T.31078.91634.75同闌杲嬪HZ0.85733.&550.2917.a1389.5&無(wú)功補(bǔ)償300T合計(jì)□.950.34T33.&250.2775.11174.40變壓器容星1000g77.5負(fù)荷計(jì)算表2序□用電設(shè)備組名稱需用(心)costbtg巾計(jì)算值備注妄裝的工佗的FjQiSjIj(kW)(War}(kVA)3)1照明插座1QQ310030.60.S50.6ECQ4.SO3H.SE2應(yīng)急唱明1401400.B50.90.4B119.0057.633■低口口空色-!8008000.50.850.62400.00247.904泊闊:!工吊!1寺30300.90.B50.6227.0016.735小計(jì)19780.8&0.611150.80697.091345.462038.5850.S3■9砧.1657S.5S1116.731692.027無(wú)功補(bǔ)償340S合計(jì)0.940.37955.2357.11019.71545.0g變壓器蓉量125010q陋)81.64TM舲洙站、空調(diào)設(shè)備):1mtn&416410.90.80.75576.G432.6S26&.4266.420.90.80.7559.TT844.834同機(jī)豈咎,參即吉由ki1201200.S50.30.75102T6.5058ZT.420.800.75T38.7554.0923.31399.06同期聚蠻0.85627.94T0.9784.81189.£7無(wú)功補(bǔ)愷3008合計(jì)0.9&0.27627.91T0.9650.7茨亍9gSOO10n(%)81.310/0.4kV變配電所本工程10/0.4變配電所,擬設(shè)在與本病房樓貼鄰的腫瘤病房樓的地下層,并與腫瘤病房樓共用10kV電源進(jìn)線。變配電所內(nèi)裝設(shè)有高低壓柜若干臺(tái)、干式變壓器柜4臺(tái)。變壓器的總裝機(jī)容量約為4300kVAo10kV配電系統(tǒng)采用單母線不分段結(jié)線方式,交流操作。操作電源采用UPS裝置,各配電柜配置微機(jī)繼保裝置,出線采用瞬時(shí)速斷、過(guò)流、接地保護(hù)以及變壓器超溫報(bào)警和超高溫跳閘保護(hù)。6.3.6低壓配電系統(tǒng)采用單母線分段的方式,兩段母線間設(shè)聯(lián)絡(luò)開關(guān),當(dāng)一側(cè)母線故障或一臺(tái)變壓器檢修時(shí),可由另一段母線對(duì)該母線上的重要負(fù)荷供電。消防負(fù)荷及重要負(fù)荷由市電母線段和發(fā)電機(jī)應(yīng)急母線段供電,并在最末一級(jí)配電箱處進(jìn)行切換。6.3.7無(wú)功補(bǔ)償采用低壓集中補(bǔ)償方式,補(bǔ)償后功率因數(shù)可達(dá)0.93以上。6.3.8計(jì)量方式:0.4kV側(cè)按當(dāng)?shù)毓╇姴块T要求進(jìn)行分類計(jì)量,以及對(duì)電力能耗監(jiān)測(cè)進(jìn)行分項(xiàng)計(jì)量。6.3.9高壓線路采用YJV22-8.7/15kV型電力電纜,低壓配電線路采用GXF-YJV-12型或ZR-YJV-0.6/1kV型阻燃電力電纜,主要采用線路在電纜橋架內(nèi)敷設(shè)。6.4動(dòng)力配電設(shè)計(jì)6.4.1本工程動(dòng)力配電采用?380/220V三相四線制電源供電,?380/220V電源引自地下層的變配電房。線路采用放射式和樹干式相結(jié)合的配電方式。6.4.2本工程在建筑物中設(shè)有電氣豎井。線路采用放射式及樹干式相結(jié)合的供電方式。對(duì)于單臺(tái)容量較大的負(fù)荷或重要負(fù)荷采用放射式供電;對(duì)于一般負(fù)荷采用樹干式與放射式相結(jié)合的供電方式。6.4.3消防電梯、防排煙設(shè)施等消防負(fù)荷以及手術(shù)室、ICU監(jiān)護(hù)室、CT機(jī)等一級(jí)負(fù)荷由變配電所不同低壓母線段提供兩回路電源,并在設(shè)備末端設(shè)自動(dòng)切換裝置;二級(jí)負(fù)荷:采用雙回路供電,在末端互投(或在適當(dāng)位置互投);三級(jí)負(fù)荷:采用單回路供電。6.4.4本設(shè)計(jì)的電動(dòng)機(jī)以低壓斷路器作短路保護(hù),熱繼電器作過(guò)負(fù)荷保護(hù)(火災(zāi)用防排風(fēng)煙機(jī)所配熱繼電器僅作過(guò)載報(bào)警),利用交流接觸器的吸引線圈作失壓保護(hù)。凡容量在30kW及以上的電動(dòng)機(jī)均采用軟起動(dòng)方式,其余容量在30kW以下的電動(dòng)機(jī)采用全壓直接起動(dòng)方式。。6.4.5動(dòng)力配電除消防負(fù)荷及重要負(fù)荷采用低煙無(wú)鹵的GXF-YJV-12型銅芯電纜或銅芯線或NH-BV-450/750V型耐火銅芯塑料線穿阻燃可撓金屬電線管敷設(shè)外,其余配電設(shè)備均采用ZR-BV-450/750V型阻燃銅芯塑料線或ZR-YJV-0.6/1kV阻燃銅芯電纜穿阻燃可撓金屬電線管敷設(shè)。6.4.6本工程的插座箱采用CZXR型,配電箱、控制箱采用非標(biāo)或JXF型,上述配電設(shè)備除在設(shè)備用房、配電豎井內(nèi)掛墻安裝外,其余均為嵌墻安裝。6.5照明設(shè)計(jì)6.5.1電氣照明采用?380/220V三相四線制供電,引自變配電房。線路以放射式或樹干式配電。應(yīng)急照明、ICU照明等重要照明電源由變配電所不同低壓母線段提供兩回路電源,并在設(shè)備末端設(shè)自動(dòng)切換裝置。應(yīng)急疏散照明燈具采用自帶蓄電池的應(yīng)急疏散指示燈及應(yīng)急雙頭燈。除消防控制室、變配電室等設(shè)備用房的應(yīng)急照明持續(xù)時(shí)間±180分鐘外,其余場(chǎng)所的應(yīng)急照明持續(xù)時(shí)間應(yīng)±30分鐘。6.5.2照明光源采用發(fā)光效率高、顯色性好的高強(qiáng)氣體放電燈及高效節(jié)能燈,照明燈具按各房間的用途設(shè)置熒光燈、金鹵燈等。小開間房間照明采用一燈一控控制方式;走道、門廳及多功能廳等大開間照明擬采用多燈分組集中控制方式。照明燈具采用吸頂安裝、嵌入式安裝等安裝方式。在消防值班室、ICU監(jiān)護(hù)室、電梯機(jī)房及主要通道等處裝設(shè)事故照明應(yīng)急燈;在走廊、樓梯間等處裝設(shè)疏散標(biāo)志燈。6.5.3照明照度按國(guó)家現(xiàn)行規(guī)范《建筑照明設(shè)計(jì)標(biāo)準(zhǔn)》GB50034-2004規(guī)定的標(biāo)準(zhǔn)值進(jìn)行設(shè)計(jì),各主要房間的照度標(biāo)準(zhǔn)、功率密度值等指標(biāo)如下:序號(hào)場(chǎng)所照度標(biāo)準(zhǔn)值(Lx)功率密度值(W/m2)顯色指數(shù)Ra1診室、治療室、重癥監(jiān)護(hù)室、護(hù)士站、辦公室300<11802手術(shù)室750W30803藥房500<20804病房100W6805休息廳、走道100806電梯前室150607候診室、變配電房200W8608樓梯間75806.5.4線路敷設(shè):事故應(yīng)急照明采用NH-BV-450/750V型耐火銅芯芯塑線穿阻燃可撓金屬電線管暗敷,其余一般照明線路采用ZR-BV-450/750V型阻燃銅芯塑料線穿阻燃可撓金屬電線管暗敷。防雷保護(hù)、安全措施及接地系統(tǒng)設(shè)計(jì)6.6.1根據(jù)《建筑物防雷設(shè)計(jì)規(guī)范》GB50057-942000年版,本工程按第二類防雷建筑物設(shè)計(jì)防雷,并設(shè)置防直擊雷、防雷電感應(yīng)及防雷電波侵入等措施。6.6.2采用?12圓鋼在屋面女兒墻敷設(shè)避雷帶作接閃器;利用建筑物鋼筋混凝土柱內(nèi)的兩條主筋通長(zhǎng)作防雷引下線;利用建筑物樁基礎(chǔ)及地梁中二主筋焊接成閉合電氣通路作接地裝置。接地裝置、引下線、屋面避雷帶焊接成一體。6.6.3本工程低壓配電系統(tǒng)接地形式采用TN-S系統(tǒng)。為防止觸電危險(xiǎn),凡電氣設(shè)備在正常情況下不帶電的外露導(dǎo)體及金屬管道均采用接地保護(hù),即與設(shè)置的專用接地保護(hù)線(PE)連接。6.6.4防雷接地及電氣設(shè)備保護(hù)接地等共用統(tǒng)一的接地裝置,要求接地電阻不大于1Q,否則應(yīng)在室外增設(shè)人工接地體。6.6.5本工程設(shè)總等電位聯(lián)接,手術(shù)室等醫(yī)療設(shè)備間以及有淋浴設(shè)施的衛(wèi)生間等處設(shè)局部等電位連接。6.6.6本工程的電源端以及有線電視、電話等引入端均設(shè)過(guò)電壓保護(hù)裝置。有線電視、電話及綜合布線系統(tǒng)設(shè)計(jì)6.7.1本工程的有線電視、電話及網(wǎng)絡(luò)系統(tǒng)的進(jìn)線均由相關(guān)的城市網(wǎng)絡(luò)引接,系統(tǒng)由甲方委托專業(yè)公司設(shè)計(jì),本設(shè)計(jì)僅為系統(tǒng)的管路敷設(shè)。6.7.2有線電視系統(tǒng)的電視前端設(shè)備設(shè)在一層*面,各層設(shè)集線器箱,電視電纜由集線器箱引至室內(nèi)的電視插座。病房?jī)?nèi)均設(shè)置電視插座,用戶輸出口電*值為69±6dB!^Vo用戶分配采用分配分支的方式,干線采用SYKV-75-9同軸電纜,分支線采用SYKV-75-5同軸電纜,并穿PVC管暗敷。本工程的用戶終端數(shù)量約400點(diǎn)。6.7.3進(jìn)線處設(shè)電話分線箱(500對(duì))一臺(tái),在各層門廳、公共走廊等適當(dāng)位置設(shè)外線直播IC卡或磁卡公用電話,辦公室、診室、護(hù)士站、治療室等醫(yī)護(hù)用房設(shè)電話插座。6.7.4網(wǎng)絡(luò)系統(tǒng)采用光纖+六類布線系統(tǒng)。系統(tǒng)主干采用光纜布線,水*部分采用6類UTP非屏蔽對(duì)絞電纜。6.7.5在診室、辦公室、護(hù)士站、收費(fèi)處以及管理用房等處按照業(yè)主的使用需求設(shè)置適當(dāng)數(shù)量的網(wǎng)絡(luò)插座。6.8病房呼叫系統(tǒng)管線設(shè)計(jì)7?26層病房每層均設(shè)置病房呼叫系統(tǒng)。系統(tǒng)由呼叫主機(jī)、呼叫分機(jī)及顯示屏組成,可隨時(shí)接受病區(qū)內(nèi)住院病人的呼叫,護(hù)士站處的主機(jī)及顯示屏上均能準(zhǔn)確地顯示呼叫患者的床位號(hào)。6.8.2系統(tǒng)線路采用RVV型屏蔽銅芯線穿PVC管敷設(shè)。7.暖通7.1設(shè)計(jì)依據(jù)7.1.1建設(shè)單位提供的設(shè)計(jì)任務(wù)書及相關(guān)要求。7.1.2建筑等專業(yè)提供的設(shè)計(jì)條件圖。7.1.3主要設(shè)計(jì)規(guī)范:《民用建筑供暖通風(fēng)與空氣調(diào)節(jié)設(shè)計(jì)規(guī)范》GB50736-2012o《高層民用建筑設(shè)計(jì)防火規(guī)范》GB50045-95(2005年版)《公共建筑節(jié)能設(shè)計(jì)標(biāo)準(zhǔn)》GB50189-2005o廣西《公共建筑節(jié)能設(shè)計(jì)規(guī)范》DBJ45/003-2012《汽車庫(kù)、修車庫(kù)、停車場(chǎng)設(shè)計(jì)防火規(guī)范》GB50067-977.2設(shè)計(jì)范圍7.2.1空調(diào):全樓設(shè)中央空調(diào)系統(tǒng),采用冷暖空調(diào),夏季制冷,冬季供暖。7.2.2通風(fēng):地下室、衛(wèi)生間及無(wú)可開啟外窗的房間設(shè)機(jī)械通風(fēng)系統(tǒng),其余有外窗的房間均采用自然通風(fēng),地下室人防單元設(shè)戰(zhàn)時(shí)通風(fēng)系統(tǒng)。7.2.3防排煙:防煙樓梯間及其合用前室、消防電梯前室均采用機(jī)械加壓送風(fēng),地下車庫(kù)及地上不滿足自然排煙條件的內(nèi)走道設(shè)機(jī)械排煙。7.3設(shè)計(jì)參數(shù)7.3.1室外空氣計(jì)算參數(shù)(參考玉林市)夏季空調(diào)室外計(jì)算干球溫度 34.0°C;夏季空調(diào)室外計(jì)算濕球溫度 27.8°C;夏季空調(diào)計(jì)算日均溫度 30.3°C;夏季通風(fēng)室外計(jì)算干球溫度 31.7°C;夏季室外*均風(fēng)速 1.4m/s;夏季*均大氣壓力 99. 5kPa;冬季室外空調(diào)計(jì)算干球溫度 5.1°C;冬季室外空調(diào)計(jì)算相對(duì)濕度 68%;冬季通風(fēng)室外計(jì)算干球溫度 13.1°C;冬季室外*均風(fēng)速 1.7m/s;冬季*均大氣壓力 100.99kPao7.3.2空調(diào)室內(nèi)設(shè)計(jì)參數(shù)房間名稱夏季冬季新風(fēng)標(biāo)準(zhǔn)m3/(h?人)噪聲標(biāo)準(zhǔn)dB(A)溫度(°C)相對(duì)濕度(%)溫度(°C)相對(duì)濕度(%)大堂、門廳25-2740-6516-1830-601050門診、辦公25-2740-6518-2030-603045會(huì)議室25-2740-6518-2030-602545病房25-2740-6518-2030-6030407.3.3通風(fēng)室內(nèi)設(shè)計(jì)參數(shù)房間名稱車庫(kù)水泵房衛(wèi)生間制冷機(jī)房換氣次數(shù)(次/h)66156/12制冷機(jī)房*時(shí)通風(fēng)6次/h,事故通風(fēng)12次/h。7.4空調(diào)系統(tǒng)設(shè)計(jì)4.1本工程地下1層,為車庫(kù)及設(shè)備用房;地上二十層,主要為門診及病房,建筑面積約33854m2o經(jīng)計(jì)算,本工程總冷負(fù)荷為3400KW,總熱負(fù)荷為1500KWo7.4.2本工程ICU病房及手術(shù)室用房采用潔凈空調(diào),各自采用獨(dú)立的空調(diào)系統(tǒng),由專業(yè)公司進(jìn)行設(shè)計(jì)及施工,僅提供冷凍水接口。7.4.3其余房間采用舒適性空調(diào),各層均采用一個(gè)統(tǒng)一的中央空調(diào)系統(tǒng)。4.4中央空調(diào)系統(tǒng)的冷熱源全部采用水冷螺桿+風(fēng)冷熱泵機(jī)組,熱泵機(jī)組及冷卻塔均設(shè)在二十層。7.4.5中央空調(diào)系統(tǒng)熱源選用3臺(tái)風(fēng)冷熱泵冷水機(jī)組,每臺(tái)機(jī)組的額定制熱量為550KW,額定制冷量為500KWo冷水機(jī)組的冷媒均為R407co空調(diào)冷凍水供回水溫度分別為7/12°C,供暖熱水供回水溫度分別為45/40°C;空調(diào)冷源除采用上述風(fēng)冷主機(jī)外另選用2臺(tái)水冷螺桿冷水機(jī)組,機(jī)組及水泵均設(shè)在地下室制冷機(jī)房?jī)?nèi)。7.4.6中央空調(diào)系統(tǒng)冷凍水(熱水)采用兩管制閉式循環(huán)一次泵系統(tǒng),采用開式膨脹水箱定壓及補(bǔ)水。設(shè)計(jì)選用7臺(tái)冷凍水泵(其中2臺(tái)備用)。立管采用異程式,各層水*管采用同程式。4.7中央空調(diào)系統(tǒng)各空調(diào)房間均采用風(fēng)機(jī)盤管加新風(fēng)的型式。7.4.8空調(diào)送回風(fēng)管采用鍍鋅鋼板,其保溫材料采用鋁箔貼面橡塑復(fù)合隔熱材料。7.5 通風(fēng)系統(tǒng)設(shè)計(jì)7.5.1地下一層的車庫(kù)及設(shè)備用房均設(shè)機(jī)械通風(fēng),自然補(bǔ)風(fēng)的方式。7.5.2地上無(wú)可開啟外窗的房間設(shè)機(jī)械通風(fēng)系統(tǒng)。7.5.3所有衛(wèi)生間采用機(jī)械排風(fēng)。7.5.4其余有外窗的房間采用自然通風(fēng)。5.5通風(fēng)管道采用鍍鋅鋼板制作。監(jiān)測(cè)與控制6.1設(shè)置中央空調(diào)變頻節(jié)能控制系統(tǒng),對(duì)冷水機(jī)組、冷凍水泵進(jìn)行節(jié)能控制,同時(shí)包括上述設(shè)備的連鎖啟??刂?,冷、熱量計(jì)量。6.2各空調(diào)房間采用自動(dòng)溫控器控制室內(nèi)溫度,要求溫控器設(shè)置在室內(nèi)的明顯位置,并能測(cè)量及顯示室內(nèi)空氣溫度。7.6.3地下車庫(kù)的通風(fēng)系統(tǒng),根據(jù)使用情況對(duì)通風(fēng)機(jī)設(shè)置定時(shí)啟??刂?。防排煙系統(tǒng)及防火設(shè)計(jì)7.7.1防煙樓梯間及其合用前室、消防電梯間前室均設(shè)機(jī)械加壓送風(fēng)進(jìn)行防煙。7.7.2不滿足自然排煙條件的內(nèi)走道設(shè)機(jī)械排煙。7.7.3地下車庫(kù)設(shè)機(jī)械排煙,其排煙系統(tǒng)與*時(shí)的排風(fēng)系統(tǒng)合用。7.7.4滿足自然排煙條件的內(nèi)走道及有外窗的房間均利用外窗自然排煙。7.7.5穿過(guò)機(jī)房隔墻及防火墻的空調(diào)及通風(fēng)風(fēng)管上設(shè)70°C關(guān)閉的防火閥,排煙風(fēng)機(jī)的入口處設(shè)280°C關(guān)閉的排煙防火閥,排煙防火閥要與排煙風(fēng)機(jī)聯(lián)動(dòng)控制。7.8節(jié)能設(shè)計(jì)7.8.1本設(shè)計(jì)采用的風(fēng)冷冷水機(jī)組的能效比為3.0,水冷螺桿冷水機(jī)組能效比為5.0,滿足《公共建筑節(jié)能設(shè)計(jì)標(biāo)準(zhǔn)》的要求。7.8.2設(shè)置中央空調(diào)變頻節(jié)能控制系統(tǒng),各空調(diào)房間采用自動(dòng)溫控器控制室內(nèi)溫度。7.8.3*時(shí)使用的通風(fēng)機(jī)全壓效率應(yīng)>60%,風(fēng)機(jī)單位風(fēng)量耗功率為0.32W/(m3/h)。7.8.4由于本工程沒有足夠的場(chǎng)地,無(wú)法采用地源熱泵空調(diào)系統(tǒng)。7.9 環(huán)保措施7.9.1空調(diào)機(jī)組的制冷劑為R407c,符合環(huán)保要求。7.9.2米用低噪音的空調(diào)機(jī)組、通風(fēng)機(jī)等空調(diào)通風(fēng)設(shè)備。7.9.3產(chǎn)生振動(dòng)的設(shè)備均采取必要的減振措施。7.9.4風(fēng)管及其保溫材料均采用不易積塵、不產(chǎn)生浮游物的材料。7.9.5將風(fēng)冷熱泵冷水機(jī)組設(shè)置在屋頂,盡量減少設(shè)備的噪聲對(duì)周圍環(huán)境的影響。8.消防設(shè)計(jì)依據(jù)《高層民用建筑設(shè)計(jì)防火規(guī)范》GB50045—95(2005版)《汽車庫(kù)、修車庫(kù)、停車場(chǎng)設(shè)計(jì)防火規(guī)范》GB50067-97《建筑內(nèi)部裝修設(shè)計(jì)防火規(guī)范》GB50222-95(2001年修訂版)《自動(dòng)噴水滅火系統(tǒng)設(shè)計(jì)規(guī)范》GB50084-2001(2005年版)《火災(zāi)自動(dòng)報(bào)警系統(tǒng)設(shè)計(jì)規(guī)范》GB50116-98《建筑滅火器配置設(shè)計(jì)規(guī)范》GB50140-2005《氣體滅火系統(tǒng)設(shè)計(jì)規(guī)范》GB50370-2005《固定式燃?xì)庑透煞蹨缁鹣到y(tǒng)設(shè)計(jì)、施工及驗(yàn)收規(guī)范》DB45/T385-2007建筑專業(yè)8.2.1本工程屬醫(yī)療類建筑,根據(jù)《高層民用建筑設(shè)計(jì)防火規(guī)范》GB50045—95(2005版)要求,為一類防火建筑,耐火等級(jí):一級(jí),設(shè)自動(dòng)滅火和火災(zāi)自動(dòng)報(bào)警系統(tǒng),走廊、地下室設(shè)機(jī)械排煙系統(tǒng)。消防控制室設(shè)于業(yè)務(wù)綜合樓一層,有直接對(duì)外開門。8.2.2在外科綜合樓三面布置車道,與消防車通道結(jié)合。建筑物的四面直接落地,可作為消防車的撲救面。8.2.3地下一層,設(shè)2個(gè)防火分區(qū),防火分區(qū)面積分別為433.80*方米(設(shè)備用房)、3030.86*方米(地下車庫(kù)),每個(gè)防火分區(qū)設(shè)一個(gè)安全出口(相鄰防火分區(qū)的防火墻設(shè)防火門)。地上二十層,每層為一個(gè)防火分區(qū),面積均在2000*方米以下。8.2.4本工程主樓設(shè)置兩部防煙樓梯,保證使用和疏散要求。8.2.5本工程設(shè)1部消防電梯。8.2.6安全疏散及疏散距離本工程為公建,主樓的兩部防煙樓梯寬度共3.15米寬,每層可疏散315人,滿足疏散要求。首層疏散樓梯直接通向室外,符合規(guī)范要求。病房部分:兩部樓梯之間房間至樓梯間最大距離不大于24mo其它部分:兩部樓梯之間房間至樓梯間最大距離不大于30mo房間最遠(yuǎn)點(diǎn)至門距離不大于15m。電梯間設(shè)前室,在走道通向前室地方設(shè)甲級(jí)防火卷簾,卷簾具有停滯功能。8.2.7建筑配件及構(gòu)造本工程防火隔墻采用20

溫馨提示

  • 1. 本站所有資源如無(wú)特殊說(shuō)明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請(qǐng)下載最新的WinRAR軟件解壓。
  • 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請(qǐng)聯(lián)系上傳者。文件的所有權(quán)益歸上傳用戶所有。
  • 3. 本站RAR壓縮包中若帶圖紙,網(wǎng)頁(yè)內(nèi)容里面會(huì)有圖紙預(yù)覽,若沒有圖紙預(yù)覽就沒有圖紙。
  • 4. 未經(jīng)權(quán)益所有人同意不得將文件中的內(nèi)容挪作商業(yè)或盈利用途。
  • 5. 人人文庫(kù)網(wǎng)僅提供信息存儲(chǔ)空間,僅對(duì)用戶上傳內(nèi)容的表現(xiàn)方式做保護(hù)處理,對(duì)用戶上傳分享的文檔內(nèi)容本身不做任何修改或編輯,并不能對(duì)任何下載內(nèi)容負(fù)責(zé)。
  • 6. 下載文件中如有侵權(quán)或不適當(dāng)內(nèi)容,請(qǐng)與我們聯(lián)系,我們立即糾正。
  • 7. 本站不保證下載資源的準(zhǔn)確性、安全性和完整性, 同時(shí)也不承擔(dān)用戶因使用這些下載資源對(duì)自己和他人造成任何形式的傷害或損失。

最新文檔

評(píng)論

0/150

提交評(píng)論